High protection against allergens and contaminants Spacious working area High cleanability and visibility Microprocessor controls and safety alarms

Similar documents
CHAMBERS AND H 2 O 2 GENERATOR

BIOSAFETY CABINETS. SURFACE WIDTH: 120cm - 48

Smart but at the same time simple design. My technicians really love them.

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

TECHINCAL DESCRIPTION BIO BAN

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Bio II Advance. Class II Biological Safety Cabinet

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

Smart design has its rewards. NEW! Thermo Scientific MSC-Advantage Class II Biological Safety Cabinet. Part of Thermo Fisher Scientific

Bio II Advance. Class II Biological Safety Cabinet

Thermo Scientific 1300 Series A2. Class II, Type A2 Biological Safety Cabinets. Good for you good for the environment

As ept i c I s olator s

PCR Laminar Flow Cabinets

Ductless Nanoparticle Containment Enclosures

PATENT PENDING. Smart but at the same time simple design. My technicians really love them.

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

is with a variety of standard dimensions. Also our units can be custom engineered to any size.

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

TITAN, ATLAS & SIRIUS SMALL, PORTABLE. economical cabinets. with low energy consumption

MiniRoom. Isolation cubicles flexibility with containment. Horizontal laminar flow of air for greater protection - positive or negative

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

PHARMACY Products. Compounding Aseptic Containment Isolator (CACI) A level of safety that is built in, not bolted on. Underwriter Laboratories Listed

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

Excelair. Every filter is created to perfection!

nivia utilities Why Air Filters???

Series. Ductless Fume Hoods The Safe, Energy Efficient Solution for Modern Chemistry

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

AM INSTRUMENTS LAF SYSTEMS

FlowFAST H. Horizontal Laminar Flow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

ASALAIR BIOHAZARD ATLANTIC CABINET MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2

topsafe Safety you can afford Microbiological Safety Cabinet Class II Type A2 CERTIFIED EUROPEAN SAFETY AT AFFORDABLE PRICES

A Thermolab Group Company. HyZone. Class II Microbiological Safety Cabinets. for operator, environment and product protection.

AS , EN12469 (Microbiological Testing Method)

BSC-1100IIA2-X is designed to meet the operating principles:

TM Series MICROBIOLOGICAL SAFETY CABINETS. Technical Specifications

PHARMACY Products. Compounding Aseptic Isolator (CAI) Positive pressure sterility assurance barrier isolator for complete product protection.

CLASS II BIOLOGICAL SAFETY CABINET

Class II biological safety cabinets

SterilSHIELD. Designed for Aseptic Compounding of Non-Hazardous Pharmaceuticals. SterilSHIELD Barrier Isolator (positive pressure)

(Class II Type A2 & B2)

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet

ASALAIR BIOHAZARD ATLANTIC CABINET MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2 MODEL:

FE-WS6 Downflow Ductless Workstation. Operator s Manual

Thermo Scientific Heraeus Primo and Primo R Centrifuges. Flexible and efficient, compact high-performance centrifuges

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

SafeFAST Top. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

EuroFlow Series. Operator, product and environmental protection. Class II Biological Safety Cabinet. Superior quality. Proven reliability

PRODUCT CATALOG CLASS II BIOLOGICAL SAFETY CABINET.

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Compounding Safety Solutions.

HORIZONTAL LAMINAR FLOW HOOD FLO

CDC F RANGE NEGATIVE PRESSURE ISOLATORS

A viewscreen top hinge allows full opening for loading of instrumentation or equipment.

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Biological Safety Cabinet

PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES

Series EuroFlow Biological Safety Cabinets Class II

Ducted HEPA filter units for highly sensitive areas

(Class II Type A2 & B2)

NU-430/435 CLASS II, TYPE B2 BIOLOGICAL SAFETY CABINETS

CG2010 Cytogard Cytotoxic Drug Safety Cabinets

FILTRATION FUME CABINET MODELS T800 T1800 OPERATING AND MAINTENANCE MANUAL

Ductless Nanoparticle Containment Enclosures

FASTER ChemFAST. Laboratory Fume Cupboards PROTECTION, SAFETY, RELIABILITY. AND MORE.

Ductless Nanoparticle Containment Enclosures

Handbook Of Microbiological Safety Cabinet Type OPTIMALE

High Performance Ductless Balance Enclosures

Contamination Control Laboratories (CCL) Pty Ltd

Angelantoni Life Science. Microbiological safety cabinets Class II. SterilSafe Series

INSTRUCTION MANUAL. AMS 1500 One Piece. Negative Pressure Unit (AMS-1500 NPU 230V)

Modular filter system for effective removal of oil mist

Class I Microbiological Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet

Downflo workstation DuSt ColleCtorS

Class II, Biological Safety Cabinets Probably the Most Advanced Energy-Efficient, Safe, and Ergonomic Biosafety Cabinet in the World

ADVANCED SAFETY ENGINEERING FOR EFFECTIVE HANDLING OF HAZARDOUS PARTICULATE DRUGS AND POWDERS IN A CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET

Thermo Scientific Heraeus Primo and Primo R Centrifuges. Flexible and efficient, compact high-performance centrifuges

Efficiency powered to infinity. Nederman Filtac oil mist filters for continuous operation

CLASS II BIOSAFETY CABINET

LAMINAR AIRFLOW EQUIPMENT

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

downflo workstation dust collectors

Mobile recleanable HEPA filter units for a flow of m 3 / h

CG INLET CEILING. Inlet ceiling with the laminar discharge flow for operating rooms

Compact Finedust / HEPA Filter

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Improving your workspace

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET

TOTALINE ELECTRONIC AIR CLEANERS

SECTION HVAC AIR CLEANING DEVICES

European Style IVC Systems

TRIMMING TECH 90. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech90. CND code: W CIVAB code:

GMP dry heat ovens for depyrogenisation and sterilisation

Handbook Of Microbiological Safety Cabinet Type BIO II 9 (4 ft) and 12 (3 ft)

CytoFAST Elite. Cytotoxic Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Extraction Arms. Capturing fumes at the source

Transcription:

High protection against allergens and contaminants Spacious working area High cleanability and visibility Microprocessor controls and safety alarms Tecniplast offers a wide range of solutions for allergen containment curing bedding disposal operations of both small and big rodents cage.

1/High Protection Against Allergens and Contaminants DS36: the bedding disposal station designed to protect the operator against exposure to allergens and from airborne contaminants generated during bedding disposal operations. 2/Safety The air from the environment is drawn into the front access opening of the station at an average speed of 0.6 m/s creating a uniform barrier. Thanks to the high velocity of the air, close to the emission point, air-borne bedding dusts are captured precisely and led to the exhaust air system. The air curtain protects the personnel and the surrounding room from bedding emissions in order to guarantee the optimal protection of people and room from allergens. Before being exhausted, the air is drawn through a pre-filter, a bag-filter and a HEPA filter. 1 High Protection Against Allergens and Containments 3/Spacious Working Area in a Compact and Ergonomic Design DS36 provides maximum operator comfort and free motion thanks to its spacious access opening. The working chamber accommodates large cages as well as smaller cages. 4/High Cleanability and Visibility Working chamber made of stainless steel is easy to clean and less subject to accidental denting or scratching. Clear Lexan side panels allow good visibility. 5/Ease of Use with the Slide Reduction Funnel DS36 features a waste bag trolley and a sliding reduction funnel allowing the operator to simplify waste bag removal under constant protection. 6/Two Levels of Pre-filtrations: Extended HEPA Filter Life A protective net for pre-filters, extend the pre-filters lifespan and protect them. The first level consists of two G4 pre-filters with an average arrestance of Am=90% (Average synthetic dust weight arrestance) which trap large particulates. The second level is achieved by two rigid bag F7 pre-filters with an elevated contact surface and an efficiency of 80% < Em<90% (Average atmospheric dust spot efficiency) on fine dusts. These filters are located behind the stainless steel swing panel that protects them from possible damage Thanks to this high efficiency of pre-filtration the inner duct of the cabinet stays very clean, thus prolonging HEPA filter life. 7/Microprocessor Controls and Safety Alarms The machine is provided with an eye-level touch pad membrane control system featuring a microprocessor which automatically controls and keeps a suitable velocity of the air curtain. An acoustic and optical alarm system indicates the alarm conditions, reducing the risk for the operator and the environment from potentially hazardous micro-organisms, in line with the European Machinery Directive and International Standards. 8/Accessories Polyethylene bin with S/S trolley with a larger base to guarantee more stability. Stainless steel waste bag trolley with hinged opening to remove the bag from the front. 9/Possibility of Integration with IWT Bedding Handling System The laminar flow cabinet can be integrated with a bedding disposal system developed by IWT to ensure totally smooth and simple material disposal and dispensing operations, cutting operator exposure and effort to a minimum. 2 Safety Environment Air Pre-filtered Air Hepa filtered Air

3 Spacious Working Area 5 Ease of Use with the Slide Reduction Funnel TECHNICAL SHEET External Dimensions (W x D x H): 1244 x 881 x 1997 mm 49 x 34 5/8 x 78 5/8 inch Chamber Dimensions (W x D x H): 1000 x 580 x 600 mm 39 1/8 x 22 7/8 x 23 5/8 inch Access Opening (W x H): 984 x 600 mm 38 3/4 x 23 5/8 inch Weight: 226 kg 498.24 lb Electrical Supply: 230 V - 50/60 Hz 100/115 V - 50/60 Hz Power Consumption: 1.0 KVA Control: Microprocessor driven (automatic constant flow rate and filter load compensation) with control panel Air Barrier Velocity: 0.60 m/s (average) Waste Bag Trolley volume: 60 litres H14 HEPA Filter efficiency (EN1822): 99.995% at the most penetrating particle size F7 Rigid Bag Filter Efficiency: 85% (average atmospheric dust spot efficiency) G4 Prefilters Arrestance: 90% (average synthetic dust weight arrestance) Note: The cabinet is available in epoxy coated steel or stainless steel version Microprocessor Controls and Safety Alarms 7 Two Level of Pre-filtrations 6 Accessories 8

1/High Protection from Exposure to Allergens The DS72 is designed to manage and control the levels of contamination generated during the dumping of big rodent cage bedding and animal waste, providing personnel and environmental protection from allergens and airborne contaminants inside the cabinet. 2/Safety In both sides the air from the environment is drawn into the front access opening of the station at an average speed of 0.6 m/s and pass through a double pre-filtration system and a HEPA filter before being exhausted. The air curtain protects the personnel and the surrounding room from emissions released from the bedding in order to guarantee the optimal personnel and room protection from allergens. Thanks to the high velocity of the air, close to the emission point, air-borne dusts are captured precisely and funnelled to the exhaust air system. 1&2 High Protection & Safety 3/Double Working - side for Optimal Containment It features an accessible workplace, open on the front side, with Integrated exhaust air filtered system.the working area is divided in two sides: one side for carrying out the dumping of bedding and animal waste operations into dedicated containers. The other side for the positioning of the trolleys to hold cages and trays to be dumped. 4/High Cleanability and Visibility Working chamber made of stainless steel is easy to clean and less subject to accidental denting or scratching. Clear Lexan side panels allow good visibility. 5/Ease of Use with the Slide Reduction Funnel DS36 features a waste bag trolley and a sliding reduction funnel allowing the operator to simplify waste bag removal under constant protection. 6/Microprocessor Controls and Safety Alarms The machine is provided with a control system featuring a microprocessor which automatically controls and keeps a suitable velocity of the air curtain. An acoustic and optical alarm system indicates the alarm conditions, reducing the risk for the operator and the environment from potentially hazardous micro-organisms, in line with the European Machinery Directive and International Standards. Double working-side/high Cleanability & Visibility 3&4 7/Two Levels of Pre-filtrations: Extended HEPA Filter Life The first level consists of two G4 pre-filters with an average arrestance of Am=90% (Average synthetic dust weight arrestance) which trap large particulates. The second level is achieved by two rigid bag F7 pre-filters with an elevated contact surface and an efficiency of 80% < Em<90% (Average atmospheric dust spot efficiency) on fine dusts. These filters are located behind the stainless steel swing panel that protects them from possible damage. Thanks to this high efficiency of pre-filtration, HEPA filter life and thus reliability is extended. 8/Accessories Mobile funnel which provides maximum operator comfort and protection during bedding disposal operation. Stainless steel waste bag trolley with hinged opening to remove the bag from the front Pallet Trolley with allergen lid designed to optimize the material flows through the facilities. Lifter in order to provide the operator with an ergonomic solution for lifting the dirty cages.

Ease of Use with the Slide Reduction Funnel 5 TECHNICAL SHEET External Dimensions (W x D x H): 2225 x 873 x 2111 mm 87 5/8 x 34 3/8 x 83 1/8 inch Chamber Dimensions (W x D x H): 2095 x 624 x 1612 mm 82 4/8 x 24 5/8 x 63 4/8 inch Fobile Funnel (W x D x H): 980 x 746 x 1000 mm 38 5/8 x 29 3/8 x 39 3/8 inch Weight: 420 kg 925.94 lb Electrical Supply: 230 V - 50/60 Hz 100/115 V - 50/60 Hz Power Consumption: 1.7 KVA Control: Microprocessor driven (automatic constant flow rate and filter load compensation) with control panel Air Barrier Velocity: 0.55 m/s (average) Waste Bag Trolley volume: 60 litres H14 HEPA Filter efficiency (EN1822): 99.995% at the most penetrating particle size F7 Rigid Bag Filter Efficiency: 85% (average atmospheric dust spot efficiency) G4 Prefilters Arrestance: 90% (average synthetic dust weight arrestance) Note: The cabinet is available in epoxy coated steel or stainless steel version Microprocessor Controls and Safety Alarms 6 Accessories 8 Two Level of Pre-filtrations 7 Environment Air Pre-filtered Air Hepa filtered Air

1/High Protection from Exposure to Allergens The DS100 is a bedding disposal station designed to manage and control the levels of contamination generated during the dumping of big rodent cage bedding and animal waste, providing personnel and environmental protection from allergens and airborne contaminants inside the cabinet. 1 High Protection from Exposure to Allergens 2/Double Working - side for Optimal Containment It features an accessible workplace, open on the front side, with integrated exhaust air filtered system. The working area is divided in two sides: the right side for carrying out the dumping of bedding and animal waste operations into dedicated containers. The left side for the positioning of the trolleys to hold cages and trays to be dumped. 3/Safety In both sides the air from the environment is drawn into the front access opening of the station at an average speed of 0.6 m/s and pass through a double pre-filtration system and a HEPA filter before being exhausted. The air curtain protects the personnel and the surrounding room from emissions released from the bedding in order to guarantee the optimal personnel and room protection from allergens. 4/Two Levels of Pre-filtrations: Extended HEPA Filter Life The first level consists of two G4 pre-filters with an average arrestance of Am=90% (Average synthetic dust weight arrestance) which trap large particulates. The second level is achieved by two rigid bag F7 pre-filters with an elevated contact surface and an efficiency of 80% < Em<90% (Average atmospheric dust spot efficiency) on fine dusts. These filters are located behind the stainless steel swing panel that protects them from possible 2 Double Working - side for Optimal Containment damage. Thanks to this high efficiency of pre-filtration, HEPA filter life and thus reliability is extended. 5/Microprocessor Controls and Safety Alarms The machine is provided with a control system featuring a microprocessor which automatically controls and keeps a suitable velocity of the air curtain. An acoustic and optical alarm system indicates the alarm conditions, reducing the risk for the operator and the environment from potentially hazardous micro-organisms, in line with the European Machinery Directive and International Standards. 6/Accessories Trolley designed to accommodate the dirty animal trays to empty. Stainless steel waste bag trolley with hinged opening to remove the bag from the front. Other accessories are available upon request.

3&4 Safety & Two Level of Pre-filtrations Environment Air Pre-filtered Air Hepa filtered Air 5 Microprocessor Controls and Safety Alarms TECHNICAL SHEET External Dimensions (W x D x H): 2660 x 1250 x 2680 mm 104 6/8 x 49 2/8 x 105 4/8 inch Chamber Dimensions (W x D x H): 2480 x 1000 x 2000 mm 97 5/8 x 39 3/8 x 78 6/8 inch Fobile Funnel (W x D x H): 1227 x 1000 x 950 mm 48 2/8 x 39 3/8 x 37 3/8 inch Weight: 450 kg 992 lb Electrical Supply: 230 V - 50/60 Hz 100/115 V - 50/60 Hz Power Consumption: 1.7 KVA Control: Microprocessor driven (automatic constant flow rate and filter load compensation) with control panel Waste Bag Trolley volume: 80 litres H14 HEPA Filter efficiency (EN1822): 99.995% at the most penetrating particle size F7 Rigid Bag Filter Efficiency: 85% (average atmospheric dust spot efficiency) G4 Prefilters Arrestance: 90% (average synthetic dust weight arrestance) Accessories 6

1/High Protection from Exposure to Allergens The Down Flow Booth DFB 3 PLUS system is a containment solution for manual cage cleaning and disposal of dirty bedding. The working area for personnel is suitable in size for the cleaning of all large cage and tray sizes, all aero allergens produced during these operations are extracted under negative pressure from within the working area. There are no physical barriers between the operator and the disposal funnel; protection is guaranteed by the vertical laminar airflow Class ISO 5 (ISO 14644-1) within the whole of the working area. 1 High Protection from Exposure to Allergens 2/Safety The constant airflow pushes the hazardous dispersed dust downward in the air stream towards the collection filters. As a result a high grade of air cleanliness is achieved at the operator s breathing height. The DFB 3 PLUS is formed by a stainless steel, AISI 304 scotch bright finished, self supporting structure. Press-bent metal sheet with 3 mm radius curvature for easy cleaning. Ventilation system: ventilation is achieved by centrifugal fans complete with microprocessor controlled regulation for the automatic compensation of clogging pre-filters/filters with optimisation of the air ducts. Filtration system: the upper filtration area is shielded by a perforated diffuser panel made of anodised aluminium. Plenum: negative pressure design to prevent escape and/or by-pass of HEPA filter by contaminated air and/or dust. Separations of the operating area: achieved by a physical barrier of flexible PVC strip curtains (2 mm thick). 3/Microprocessor Controls and Safety Alarms The control panel and the electrical box are placed on the vertical backside wall. The Control Panel gives access to any function and improves and simplifies all setting procedures, enhancing the flexibility of the system. The Supervisor s password safely defines the boundary between users; User level 1 ability to acknowledge any relevant information in real time, and Supervisors level 2 with the ability to modify the unit configuration. Safety 2 4/Possibility of Integration with IWT Bedding Handling System The DFB3Plus can be integrated with a bedding disposal system developed by IWT to ensure totally smooth and simple material disposal and dispensing operations. Cutting operator exposure and effort to a minimum. 5/Accessories Shredder to ensure fine shredding and to prevent clogging upstream of conveyance since the material is rendered uniform in size and weight. Different kind of trolley to effectively accommodate any type of load and cage sizes. Other accessories are available upon request. Environment Air Pre-filtered Air Hepa filtered Air

Microprocessor Controls and Safety Alarms3 TECHNICAL SHEET External Dimensions (W x D x H): 2980 x 3400 x 2800 mm 117 3/8 x 133 7/8 x 110 2/8 inch Working Area (W x D x H): 2900 x 2700 x 2100 mm 114 1/8 x 106 2/8 x 82 5/8 inch Weight: 1100 kg 2425 lb Electrical Supply: 230 V - 50/60 Hz 100/115 V - 50/60 Hz Maximum Power Consumption: 20 A Control: Microprocessor driven (automatic constant flow rate and filter load compensation) with control panel Laminar Air Flow Velocity: 0.35 m/s (average) H14 HEPA Filter efficiency (EN1822): 99.995% at the most penetrating particle size F7 Rigid Bag Filter Efficiency: 85% (average atmospheric dust spot efficiency) G4 Prefilters Arrestance: 90% (average synthetic dust weight arrestance) 5 Accessories

1/Protection from Exposure to Allergens The AC74 is an allergen control booth that prevents allergens from spreading in the changing area, protecting both operator and environment. The cabinet aspirates the aerosol particulate generated during the operations of stacking cages containing dirty bedding and thus prevents the diffusion of allergens in the surrounding 1 High Protection from Exposure to Allergens environment while the dirty cages are in the changing area, before being moved to the emptying/cleaning area. 2/Safety The cabinet features two phases of filtration that guarantee an ISO 5 class (EN ISO 14 644) final HEPA filtration. The first pre-filtration phase consists of four G3 efficiency pre-filtering cells. The second filtration phase features an H13 efficiency HEPA filter. 3/Microprocessor Controls and Safety Alarms Soft touch electronic control with luminescent graphic display located in an easily accessible position. Thanks to the graphic display, a menu with diagnostics enables the operator to check the condition of the HEPA filter and receive precise updates on scheduled maintenance, the established date of replacement and the date of the last DOP test carried out. The machine is provided with alarms that are activated when the velocity of the air curtain drops below or exceeds the set point, or when a power failure occurs (in which case, when the power comes back the machine automatically reactivates the ventilation, while the display shows the power failure and its duration). The pre-alarms give a signal 500 hours before the maintenance interventions for the HEPA filter have to be carried out. Safety 2 4/Mobility and Ergonomics Without needing to be connected to the laboratory air extraction/draining system, the AC74 can be wheeled in any part of the laboratory. An electrical power socket is all that is required. 5/Accessories Pallet Trolley with allergen lid designed to optimize the material flows through the facilities. Lifter in order to provide the operator with an ergonomic solution for lifting the dirty cages.

Microprocessor Controls and Safety Alarms Mobility and Ergonomics 3 4 TECHNICAL SHEET External Dimensions (W x D x H): 1360 x 880 x 2261 mm 53 4/8 x 34 5/8 x 89 inch Chamber Dimensions (W x D x H): 1250 x 660 x 1800 mm 53 1/8 x 26 x 70 7/8 inch Weight: 280 kg 617.29 lb Electrical Supply: 230 V - 50/60 Hz 100/115 V - 50/60 Hz Power Consumption: 1.0 KVA Control: Microprocessor driven (automatic constant flow rate and filter load compensation) with control panel Barrier Air Flow Rate: 1400 m 3 /h H13 HEPA Filter efficiency (EN1822): 99.95% at the most penetrating particle size G3 Prefilters Arrestance: 80% (average synthetic dust weight arrestance) Note: The cabinet is available in epoxy coated steel or stainless steel version 5 Accessories

Related Products To maximise operational efficiency and learn more about these products contact your local representative. GP Decontamination Lock. Full decontamination cycle, with 6 log reduction, in one hour all inclusive. The unit may be used with Vaporized Hydrogen Peroxide generators from different vendors, gaseous Chlorine Dioxide generators and for chemical fogging. Sealsafe Plus: high containment, certified protection from allergens, high density and practicality of use. The IVC (r)evolution. Logistic trolleys offer safety and ergonomic features that enable high load-density for moving cages and bottles, crates, pallets and covers. HEADQUARTERS ITALY Tel. +39 0332 809711 www.tecniplast.it E-mail: tecnicom@tecniplast.it sister companies AUSTRALIA/NEW ZEALAND Tel. + 61 2 8845 6500 www.tecniplast.it E-mail: info@tecniplast.com.au CHINA Tel. + 86 21 50810920 www.tecniplast.cn E-mail: tecniplastchina@tecniplast.it FRANCE Tél. 04 72 52 94 41 www.tecniplast.fr E-mail: info@tecniplast.fr GERMANY Tel. 08805 921320 www.tecniplast.de E-mail: info@tecniplast.de UNITED KINGDOM Tel. 0845 0504556 www.tecniplast.it E-mail: info@tecniplastuk.com JAPAN Tel. + 03 5770 5375 www.tecniplast.it E-mail: info@tecniplastjapan.co.jp USA/CANADA Toll Free: 877.669.2243 www.tecniplastusa.com E-mail: info@tecniplastusa.com To find your local distributor, please visit www.tecniplast.it ISO-9001 - Cert. n 0875 ISO-14001 - Cert. n 0256A/0 Tecniplast reserves the right to change or modify product and or specifications without notice or obligation. DS36, DS72, DS100, DFB3 Plus and AC74 are Tecniplast trademarks. CAT094/ING - Rev. November 2012