Bistable Relay. Types PSU6n, PSU14n.

Similar documents
Bistable Relay. Types PSU6n, PSU14n. Station Automation & Protection. ABB Substation Automation Products

Auxiliary Relay. Type RXP8n, RXPQ8n

Auxiliary Relay. Type CV2

Auxiliary Relay. Type P8n, PQ8n, PN8n

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

Integrated water management solutions

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Distribution transformers Efficiency over life-cycle

OUTDOOR OFF LOAD DISCONNECTORS HCB/HDB Range

Reverse power relay and protection assemblies

Motor-drive mechanism, type BUL. Technical guide

Motor Protection Circuit Breaker

Technical Information

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

AF series contactors (9 2650)

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

MEDIUM VOLTAGE SWITCHGEAR

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

AF series contactors (9 2650)

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

3TM Vacuum Contactors

RAPIER DSB Disconnectors

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Quality Products, Prompt Service, Trustful Relationships.

Breaker failure relay REB 010

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Multi-purpose percentage restraint differential protection

Outdoor vacuum breaker for railway applications - FSK II

Short form catalogue. Motor protection & control

Disconnectors MF range (0,5 to 3000 Hz) (1250 to Amp)

Unitole UP kv Primary substations Motor control centres

AIR CORE REACTORS. Phoenix Electric Corporation

Unitole UP kv Primary substations Motor control centres

Mini contactors B6, BC6 with 3 pole

DBM Range 1500VDC (13,5kA to 20kA)

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

About us. Switchgear Factory, Mumbai

Series CA5 Contactors

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

CI-TI Contactors and motor starters Types CI 61 - CI 98

UMBW-UL489 and UL1077 Listed

The galvanic separation of the primary or actuating circuit and the load circuits

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

SafeGear TM Motor Control Center Arc resistant metal-clad construction

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Cobra-S. Catalog Cobra-S

BC Mini Contactor VDC

Auxiliary contact blocks - with spring terminals Accessories

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Automotive Relays Plug-in Mini ISO Relays. Power Relay F4

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

The contactor for large horsepower applications

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

Customized switching solutions High current solutions

AF40... AF96 3-pole contactors Technical data

Contactor Types CI 61-98

JOSLYN CLARK VACUUM CONTACTORS

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

Protection Equipment

Description. Positive safety relays

Motor Protection Circuit Breakers

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Functions provided by measuring relays in railway equipment

Catalog. Low voltage General performance IE3 efficiency cast iron motors

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Electropneumatic Timing Relays Series 7000 Industrial

Industrial Contactors CTX 3 3P 185A - 800A

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Command and signalling E 250, E 259 selection table

Change-over Disconnectors HUVS Range 12kV (630 to 6300Amp)

Inductive Proximity Sensor

C1000 Series Automatic Cap Bank

Indoor Metal Clad Switchgear Type:Cubicle VHA 36 SF6 Circuit Breaker HPA 36 Rated Voltage: ABB Power Distribution

Medium voltage products. Fuses

AE 9... AE 40 Contactors NE... Contactor Relays

Flexible. Intelligent. Trendsetting.

Publication No.: PSG

Ktec Contactors and thermal overloads

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

The Contactor. Antonino Daviu, Jose Alfonso Departamento de Ingeniería Eléctrica. Universitat Politècnica de València

Twin coil relays TCR and TCR-F. Chassis Systems. Conditions

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

B Mini Contactor V Hz

Thermal Overcurrent Circuit Breaker 3120-F...

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Transcription:

Bistable Relay Types PSU6n, PSU14n.

ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering environmental impact. The ABB Group of companies operates in around 100 countries and employs over 1,05,000 people. In India, ABB serves customers with the complete range of power and automation technologies. The company has a vast installed base, extensive manufacturing facilities and a countrywide marketing and service presence. As a part of its Power Technologies offering, ABB serves electric, gas and water utilities as well as industrial and commercial customers with a wide range of products, systems and services for power generation, transmission and distribution. ABB s system offering ranges from Electrical Balance of Plant (EBOP) for power plants, bulk power transmission, turnkey substations and complete electrification to utility automation and power distribution. The product offering covers a wide spectrum of technologies across the entire voltage range including indoor and outdoor circuit breakers, air and gas insulated switchgear, disconnectors, capacitor banks, reactive power compensators, power transformers, distribution transformers, instrument transformers, Compact Secondary Substations (CSS) and Ring Main Units (RMU). Advantage ABB 120 years of technology and innovation Unparalleled domain competence Global experience Complete solution capabilities Large installed base Environment-friendly technologies 2 ABB

Bistable relay types PSU6n, PSU14n Features High degree of reliability, even when it has been idle for a long time PSU14n.. with mechanical flag type indicator 6 / 14 contacts with double interruption Contact configuration can be changed with ease Different mounting variants Wide range of voltage and contact configuration Application For remote and automatic controls there is often a need for contactors which have two stable contact positions, even in the dead state. This requirement is fulfilled by changeover contactors type PSU..n.. The application of alternate control pulses to the coils cause the contacts to change from the one state to the other. If the supply is interrupted, the contacts remain in their previous position, even when the voltage is restored. Description Basically, the PSU changeover contactors are composed of the same constructional elements as the established contactors type P8n. Two magnet systems are inter- connected by a pivoted element. In the type PSU6n... with 6 free contacts, only one system has contacts; in type PSU14n... with 14 free contacts, both systems have contacts. In each case two contacts are required for changing over the connection of the coils. The contacts are arranged symmetrically on both sides of the relay coil and armature assembly in two stacks. They are easily accessible and the conversion from N/C to N/O contacts and vice versa is simple. The maximum rated voltage is 250V DC or AC and the material used is hard silver. The following definitions apply for reset and operate condition: Reset condition - Armature assembly position is away from the base i.e. the upper system has been pulsed and lower system is ready to be pulsed. The flag strips are invisible i.e. white during this condition. Operate condition - Armature assembly position is closer to the base i.e. the lower system has been pulsed and upper system is ready to be pulsed. The flag strips are visible i.e. red during this condition. A transparent, incombustible cover with a gasket protects the contacts against dirt. The terminals of the contact stacks themselves permit two wires of 1.5mm diameter maximum to be secured. The terminals on the base for the external wiring have holes with a diameter of 3.8mm. The terminals on the plug-in base can accommodate two wires, each with a cross-section of 2.5mm 2. Changeover relays must always be mounted with the contact post horizontal, that is with the base on a vertical surface. The plug-in version offers many advantages, both from the point of view of installation and afterwards for maintenance. It is fitted with locating pegs which prevent it from being inserted the wrong way round. The labelling of the terminals on the base is identical to that on the contact stacks. Type designation of auxiliary relays PSU Basic relay 6n 14n with 6 free contacts and without indicator with 7 or14 free contacts and with indicator 2Y 4Y X 2X mounted on sheet-metal base with 2 sets of terminal blocks mounted on sheet-metal base with 4 sets of terminal blocks mounted on one set of plug-in base mounted on two sets of plug-in base Example: PSU14nX denotes a PSU type relay with 7 free contacts, mounted on one set of plug-in base. Available types: ABB 3

Technical data Energizing quantities, rated values and limits Rated voltage U N 24, 30, 48, 110, 125, 220, 250 V DC Operative voltage range +10%, -20% of U N Permitted ambient temperature range 0 o C to +55 o C Pick-up voltage (%U N ) < 80% Pick-up time at U N (typical) 20-40 m sec Maximum power consumption at the instant of 65 W switching Mechanical durability tested acc to IEC 255 1 x 10 6 switching operations, 200 Draw-out / Plug-in operations Weight Type PSU6n2Y 1.5 Kg Type PSU6nX 1.3 Kg Type PSU14nX 2.1 Kg Type PSU14n2X 2.5 Kg Type PSU14n4Y 2.4 Kg Contact data Contact configuration Type PSU14n 7N/O+7N/C, 8N/O+6N/C, 9N/O+5N/C, 10N/O+4N/C, 11N/O+3N/C, 12N/O+2N/C, 13N/O+ 1N/C or 14NO Type PSU6n 3N/O+3N/C, 4N/O+2N/C, 5N/O+ 1N/C or 6NO Type PSU14nX 4N/O+3N/C, 5N/O+2N/C, 6N/O+1N/C, or 7N/O Rated voltage 250V DC/AC Rated current 5 A Max. making current 50 A, 0.5 sec, Max. breaking capacities Voltage 24V 48V 110V 250V Contacts 1 2 in 1 2 in 1 2 in 1 2 in 2 in Parallel parallel parallel parallel series DC resistive load 5A 10A 5A 10A 5A 7A 1A - 5A DC inductive. L/R =15ms 5A 10 A 5 A 8 A 4 A - 1 A - 4 A DC inductive, L/R =40ms 4 A 8 A 4 A 8 A 3 A - 0.5A - 2 A AC resistive & inductive 10 A - 10 A - 10 A - 10A - - Electrical endurance; 0.2 million operations, Tested according to IEC 255-23 at 110 V DC, 0.5A L/R 40 ms Terminals Suitable for 2x2,5mm 2 wires Electrical tests Measurement of resistance; tested acc. to IEC 255-6 +/- 10% of specified Temperature-rise; tested acc. to IEC 255-6 Coil (class F) Insulation resistance; tested acc. to IEC 255-5 >100 M Ohm at 500 V dc Dielectric; tested acc. to IEC 255-5 2.0 kv 50 Hz, 1 min Impulse; tested acc. to IEC 255-5 5 kv, 1.2/50µs, 0.5J Environmental tests Vibration response; tested acc. to IEC 255-21-1 10-150Hz; 0.5g; 3 axis Vibration endurance; tested acc. to IEC 255-21-1 10-150Hz; 1.0g; 3axis Dry heat; tested acc. to IEC 68-2-2 at +55 o C in energized condition Dry cold; tested acc. to IEC 68-2-1 at 0 o C Damp heat (cyclic - 6days); 12 Hr/55 o C + 12 Hr/25 o C x 2 @ 93% RH Tested acc. to IEC 68-2-30 Storage test; tested acc. to IEC 68-2-48 +70 o C for 72 Hrs and -25 o C for 72 Hrs 4 ABB

Connection diagram and contact configuration Fig.1- Relay type PSU14n on sheet-metal base mounting or on plug-in base mounting. The contact positions are shown for relay in reset condition. ABB 5

Fig.2- Relay type PSU14n on plug-in base mounting. The contact positions are shown for relay in reset condition. Fig.3- Relay type PSU6n on sheet-metal base mounting or on plug in base mounting. The contact positions are shown for relay in reset condition. Ordering details: Relay type Auxiliary voltage Contact configuration 6 ABB

Dimensions Legend Aa : Terminals Db : Mounting hole E01 : Cut-out for rear wiring * : Space for removing hood Ls : Operation signal Ob : Fixing screw 2) : Base fixing screw ABB 7

Ordering details Refer type designation for selection and mark ( ) appropriate boxes Type : PSU6n2Y Qty... Item no... PSU6nX Qty... Item no... Aux Voltage : 24VDC Contacts 6N/O + 0N/C 30VDC 5N/O + 1N/C 48VDC 4N/O + 2N/C 110VDC 3N/O + 3N/C 125VDC 220VDC 250 VDC Type : PSU14nX Qty... Item no... Aux Voltage : 24VDC Contacts 7N/O + 0N/C 30VDC 6N/O + 1N/C 48VDC 5N/O + 2N/C 110VDC 4N/O + 3N/C 125VDC 220VDC 250VDC Type PSU14n4Y Qty... Item no... PSU14n2X Qty... Item no... Aux Voltage : 24VDC Contacts 14N/O + 0N/C 30VDC 13N/O + 1N/C 48VDC 12N/O + 2N/C 110VDC 11N/O + 3N/C 125VDC 10N/O + 4N/C 220VDC 9N/O + 5N/C 250VDC 8N/O + 6N/C 7N/O + 7N/C PSU6n/05/2006/01-1500 ABB Limited Distribution Automation Maneja, Vadodara 390 013, India. Tel: +91 265 2604384/5/6 +91 265 2604397 Fax: +91 265 2638922 E-mail: aicds@in.abb.com Regional Marketing Offices: North No.14, Mathura Road P.O. Amar Nagar Faridabad 121 003 Tel: +91 129 2275592, 2279627, 5049000 Fax: +91 129 2279692/5019 West ABB House Dr. S B Path Ballard Estate Mumbai 400 038 Tel: +91 22 56318231 39 Fax: +91 22 56318276/77 South Embassy Star, 1st Floor No. 8, Palace Road Vasanth Nagar Bangalore 560 052 Tel: +91 80 22949779 Fax: +91 80 22949808 www.abb.co.in East 4th Floor No. 9 Elgin Road Kolkata 700 020 Tel: +91 33 22832906/8 Fax: +91 33 22832990 Central Vandana House 1st Floor G E Road, Ramkund Raipur 492 001 Tel: +91 771 5060816-8 Fax: +91 771 5053391 Century Plaza No. 3C, 3D & 3F, 3rd Floor 561 / 562, Anna Salai Teynampet (Mount Road) Chennai 600 018 Tel: +91 44 24340201 Fax: +91 44 24340282