Type V Accent Light Installation

Similar documents
PARTS AND SERVICE MANUAL

DVS Cypress Face Installation Instructions (SKU )

Service Manual. Model Number: DF2426GB DF2426SS DF2550 DF2562. UL Part Number to 500

DVL Cypress Face Installation Instructions (SKU )

Service Manual Mozart Fireplace

1080 CF Valve Replacement Instructions

INSTALLATION INSTRUCTIONS

C35. Assembly Instructions. Mobius Floor Lamp & C Page 1 of 7. Prepare Base (Figures 1& 2)

INSTALLATION INSTRUCTIONS FOR PCDE-36VA CONVERSION KIT

C35 Mobius Floor Lamp & C Page 1 of 7

INSTRUCTIONS. Power Panel. Installation Instructions


Make sure all wiring is inserted into the cavity between the insert and the fireplace. Failure to do this may cause the wiring to become damaged.

FOR SIT-STAND WORKSTATION

564 Shadowbox Face (w Screen) Instructions

Service Manual. Model Number UL Part Number BF33STP BF33DXP BF39STP BF39DXP BF45DXP

GreenStart Igniter for Inserts: Installation Instructions (SKU )

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Assembly Guide ELECTRIC. Model Numbers: C1. (English) /14/11

MODEL RVS304. REMOTE CONTROLLED SAFETY PILOT KIT Supplemental Installation Instructions for use with Natural Gas Log Sets

WARNING. Important Notice

Instruction Sheet P/N _01 3/2013

DVM36/42 SERIES LOG SET/BURNER MODULES INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Dry Contact Closure Interface

Fan, DVI Insert 31 and 33 DVI Installation Instructions (sku )

MODEL SCA Installation and Operation Manual Important:

M GT 2005 up Mustang ENGINE START Push-Button INSTRUCTION SHEET

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR DSP9600/9100 WHEEL BALANCER

Step 2 Insert the LEGS into the LEG CROSS BARS as shown below. Lock Washer. Long Legs. Wheel Axle. Cotter Pin. Hub Cap. Washer

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

SIT Pilot Assembly Retrofit - # 308 (Replaces R. Shaw Pilot Asbly) (SKU # )

OPERATING & SERVICE PARTS MANUAL SM20ES ENERGY SMART WRAPPER

assembly guide ELECTRIC Model Numbers: Estimated time required for assembly: 1 Hour (English) /02/10

Troubleshooting Guide: 355 Lights (24V)

IMPORTANT SAFETY INFORMATION

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

LAMPS 8L - 1 LAMPS CONTENTS

Troubleshooting Guide: 355 Lights (12V)

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Section 7 - Troubleshooting Guide

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

LiteBox /FireBox / Operating Instructions. (Rechargeable) 99 Washington Street Melrose, MA Phone Toll Free

Universal Bench-top Conveyor OPERATOR S GUIDE

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation Instructions

Subaru 5-Speed Double Adjustable Short Throw Shifter

INSTALLATION INSTRUCTIONS

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Self-Testing Industrial Series

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

D-4D Injector Install procedure

Push Start Ignition (05-10 All) Installation

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

2010+ Audi B8 S4/S5 3.0T S-FLO Intake Kit INSTALLATION GUIDE FOR RACING USE ONLY

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

RigMaster Power Service and Repair Manual Document # S901009

SMIDLEY MINI-SCALE RETROFIT INSTRUCTIONS

ETF-600 Sensor Operated Lavatory Faucet

Installation & Operation Instructions. Deluxe LED Spot Light

Remove black panel shown. Save 6 retaining pins for re-install later. Pry up on center part of pin first. Then pry out entire retaining pin.

Portable Lighting Equipment Operating Instructions Table of Contents

Spectron Industrial Series

Solar Flood Light. Instruction Manual Models: GS-203, GS-203-WW

LT Charging Cart for Laptops

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

Adjustable Light Kits E-Z-Go TXT All Models Installation Instructions

PRELIMINARY INSTALLATION INSTRUCTIONS PARTS LIST. Combination light switch Right fog light. 4 Self-tapping washer-screws.

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

A B C D E F. Tools Required (supplied by others)

Anchorage SS Center Model AN3050. Installation, Maintenance, and Operation Manual

Installation Instructions Rotation Control Kit

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

ASSEMBLY INSTRUCTIONS

9' Warm White /Multi LED Color Changing M5 One Plug tree V INSTRUCTION MANUAL

Checker Unload Checkstand Installation Instructions

ELS Electronic Lighting System

Chain/Belt Drive Models PRE-INSTALLATION CONSIDERATIONS

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Performance Inlet Manifold

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

INSTALLATION INSTRUCTIONS

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

PN PONTIAC FIREBIRD. Kit Contents: Four Panel Sequential LED Tail Light Kit Installation Guide

Section II - Installation Procedures Part Number : Accessory Code IL1 Kit Contents. Color Applicability/Trim Level. Hardware Bag Contents

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

MODELS: SPL-12W, SPL-12B, SPL-12C IMPORTANT! READ THESE INSTRUCTIONS BEFORE INSTALLING AND USING THIS PRODUCT.

NOTE. Figure 2. Mounting Configurations (View shown from rear of LED Bar) Figure 3. Rear Deck Mounting NOTE

NOTE. Figure 2. Mounting Configurations (View shown from rear of LED Bar) Figure 3. Rear Deck Mounting NOTE

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

NOTE: The orientation of the mounting brackets are critical. (See Figure 4)

Transcription:

Packing List: Rheostat Assembly (with cover plate, knob, screws) Accent Light Assembly (with strain relief plate) (2) T4 Halogen Bulbs Bulb Type 35 Watt 120 Volt T4 Halogen Bulb (G6.35 Base) Installation Make sure power to the heater has been turned off prior to installation (disable the breaker). If using the optional firebacks, install them prior to the accent light. NOTE: The bulbs are shipped separately. Do not touc the bulb oil or other residue left on the bulb may lead to premature bulb failure. Use the packaging (or paper towel) to handle the bulb 1. Install the rheostat assembly as shown to the right. d Route the wiring harness under the burner to the back side of the fireplace. c Plug the power cord into the receptacle on the left side of the fireplace. a Attach the rheostat assembly to the fireplace with the two black screws. b Attach the quick connects from the rheostat assembly to the quick connects on the accent light assembly. NOTE: Make sure one white and one black wire attach to each pair of wires. Page 1 of 6 6/6/08 Travis Industries, Inc.

2. Remove the log shelf following the directions below. Remove the log shelf NOTE: The grate is not shown in the illustrations to better show component removal. It may be left in place during accent light installation. Page 2 of 6 6/6/08 Travis Industries, Inc.

3. Install the accent lights following the directions below. Remove the cover plate and a gasket under the firebox. b Insert the lamp bases through the gasket (removed in step a ) and into the area underneath the burners. The gasket fits snug around the strain relief. c Attach the strain relief bracket attached to the wiring harness to the firebox with the screws removed in step a. d Route the lamp bases to both sides of the burner. e Use a screwdriver to pry these two plates out 45 g Remove the lamp mounting bracket from the burner f (two holes are provided above the bracket to allow the screws to be removed). Install the bulb into the lamp base (do not touch the bulb - use the foam inside the packaging to handle). With the nuts on the back of the lamp base loosened several turns, slide it into the bracket. Tighten the nuts to secure. h Slide the bracket into place and secure using the screws removed in step f. NOTE When installing the logs and embers, place an ember in these two locations - this prevents light from exiting the crack and creating a beam of light. i Repeat steps e through h for the opposite side. Page 3 of 6 6/6/08 Travis Industries, Inc.

4. Make sure the wiring leading from the accent light to the strain relief is properly routed. Excess wire may be pulled through the strain relief. Make sure the wiring does not contact any of the burners or other hot surfaces. 5 Restore the fireplace to the correct configuration, restore power to the fireplace and test operation of the accent lights. Page 4 of 6 6/6/08 Travis Industries, Inc.

Optional Wall-Mounted Rheostat NOTE: Many areas require all wiring to be installed by a qualified electrician. Check with your local building official for any requirements in your area. 1 Remove the rheostat from the rheostat assembly. 2 Detach the three wires leading from the rheostat (secured with wire nuts). Attach the rheostat assembly to the fireplace (see step # 1 from the installation instructions). Attach the quick connects from the rheostat to the quick connects from the accent light assemblies (see step # 1 from the installation instructions). 3 Attach three suitable wires (insulated & sheathed) to the rheostat. Install the rheostat into a junction box at the remote location. Run the wire from the junction box to the fireplace. Use the included wire clamp to secure the wiring as it passes through the fireplace (see the illustration below). 4 Connect the three wires from the rheostat to the three wires on the wiring harness disconnected in step 2 (use the included wire nuts). Follow the instructions for installing the accent lights (step # 2 on). Rheostat (removed from rheostat assembly) Junction Box Romex Connector Knob (included) Rheostat Assembly A 7/8 diameter hole is provided on this cover plate (both sides). If this hole is already used for a gas inlet, you can drill an additional 7/8 hole in this cover plate. Page 5 of 6 6/6/08 Travis Industries, Inc.

Accent Light Operation OFF LOW HIGH Turn the dial all the way counter-clockwise until it clicks off. Turn the dial 180 clockwise until the light begins to glow. The high position is all the way clockwise. NOTE: The accent light responds best when turned to high, then turned down to the desired light level. Bulb Replacement NOTE: Do not touch the bulb oil or other residue left on the bulb may lead to premature bulb failure. Use the packaging (or paper towel) to handle the bulb. The bulbs must be replaced with 35 Watt 120 Volt T4 Halogen Bulbs (G6.35 Base) available at most hardware stores. To replace the bulb, simply remove it from the socket and insert the new bulb (pin orientation does not matter). Page 6 of 6 6/6/08 Travis Industries, Inc.