Our Focus is Quality to Meet Your Standards

Similar documents
Reference Standards Petroleum & Petrochemical

NEW? REFERENCE STANDARDS PETROLEUM & PETROCHEMICAL MATERIALS. What s. look for this circle

Hydrocarbon standards for GC analysis 2016

Chapter 2 : The Composition of Petroleum and its products

COOPER BASIN CRUDE OIL. Santos Limited

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA

Chapter 2 : The Composition of Petroleum and its products

炭化水素 - 直鎖炭化水素 炭化水素 - 炭化水素及びアルコール類

Tung Xiao Dan Assistant Chemist Mark Tan Section Head Feedstock Evaluation Department

PetroChemical Standards

PetroChemical Standards

Geochemical de-risking in Arctic Regions: Identifying Hydrocarbon Phase Before Drilling. Finding Petroleum: Exploring the Arctic 11 th October 2011

MUTINEER EXETER CRUDE OIL. Santos Limited

STUDY OF CHANGES IN THE HYDROCARBON COMPOSITION OF GASOLINE AFTER EACH STAGE REFORMING REACTOR

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

ASTM D Test to Low ppb. Contact us today for a copy of the Southwest Research Institute D-5453 Fitness for Use Report.

International Journal of Oil, Gas and Coal Engineering

ASTM. Internal Standard M-GRA-IS-AS-5ML $ 20 / 1 x 5 ml M-GRA-IS-AS-5ML-PAK SAVE 20% $ 80 / 5 x 5 ml. 2-Hexanone (Neat) Selectivity Check Standard

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

TABLE S-1 Emission source and source profile categorization in the PRD region

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Petroleum calibration Standards & reference materials

Beverage Grade Carbon Dioxide

Effect of Air- Fuel Ratio on Engine- Out Exhaust Hydrocarbon Species from a Direct Injected Gasoline Engine. April 6, 2016

Rapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Module8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS

Analysis and Chromatographic Separation of Oxygenates in Hydrocarbon Matrices

APPENDIX A HEXATRIACONTANE TRACER BLENDING PROTOCOL. SwRI Final Report /13029

REFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns

Organic Compounds in Produced Waters from. Shale Gas Wells

Application. Gas Chromatography June 1995

The Stability of Sulfur Compounds, Low Molecular Weight Gases, and VOCs in Four Air Sample Bag Materials

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Air Quality Monitoring Results Supplementary Data Department of Environment and Local Government

MISSING INFORMATION ON APPARATUS GROUPS IN COLUMN i OF CHAPTER 17 OF THE IBC CODE

Underground Storage Tanks Compliance Monitoring with Restek Analytical Reference Materials

LUFT/LUST Petroleum Standards State Methods

National Oil Corporation Libyan Petroleum Institute. Crude Oil Assay Messla Crude Oil

Crude Assay Report. Crude Oil sample marked. Barrow Crude Oil. On Behalf Of. Chevron Australia Pty Ltd. Laboratory Supervisor. Crude Assay Chemist

National Oil Corporation Libyan Petroleum Institute. Crude oil assay Sarir crude oil

Restek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades

Comprehensive Gas Chromatography (GCxGC) Analysis of High-Ethanol Containing Motor Fuels

State of Alaska UST Monitoring

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Complete Fractionation of Extractable Petroleum Hydrocarbons Using Newly Developed EPH SPE Cartridges

Operation and Applications of Differential Flow Modulation

CERTIFICATE OF ACCREDITATION

Rapid Qualitative GC-TOFMS Analysis of Unleaded Gasoline

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

International Quality Assurance Exchange Program Schedule. Fuel Month Number Type Dispatch Date Closing Date

Heartland Pipeline. Heartland Pipeline Company Product Specifications. Effective Date: 10/1/2015

Supply of Services for Detailed OEB Crude Assay Analysis

Annex no. 1 of Accreditation Certificate no. LI 333 from

PSF REFORMULATED FUEL REPORT OF REFORMULATED GASOLINE UTILIZING RAW FUEL FROM FCC REFINERY UNIT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ANALYTICAL RESULTS. PWS ID/Name: ROCKHOUSE MOUNTAIN - CONWAY Report Date: 03/29/2016

Enhanced Hydrocarbon Fingerprinting. TCEQ Trade Fair. May 2018

Analysis of Petroleum Fractions by ASTM D2887

C2, C3, C4 Monomer Analysis

IROX 2000 IROX DIESEL

OptiFuel. solid partners proven solutions. Precision and portability in a top of the line FTIR Fuel Analyzer

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Eagle Ford shale air quality. Gunnar W. Schade and Geoffrey Roest San Antonio, 18 November 2014

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

Lecture 3: Petroleum Refining Overview

Chapter 11 Gasoline Production

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

APPLICATION OF SOLID PHASE MICROEXTRACTION (SPME) IN PROFILING HYDROCARBONS IN OIL SPILL CASES

Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds

OptiFuel. solid partners proven solutions. Precision and portability in a top of the line FTIR Fuel Analyzer

On-Line NIR Analysis for Blending

OZONE REACTIVITY ANALYSIS OF EMISSIONS FROM MOTOR VEHICLES

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009

Chapter 2 Outline: Alkanes

The Analysis of Total Petroleum Hydrocarbons. Hazel Davidson Technical Marketing Manager Derwentside Environmental Testing Services

ASTM D 6730 Detailed Hydrocarbon Analysis

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010. ASTM INTERNATIONAL 100 Barr Harbor Drive West Conshohocken, PA Amy Meacock

Residuals: Supplementary Information

Bright prospects Solvents for spectroscopy Uvasol

Brushwood-chulha Average (SD) Mixed-chulha Average (SD) Dung-angithi Average (SD) SOAP koh (x ) (cm 3 molec -1 s -1 )

Study on Relative CO2 Savings Comparing Ethanol and TAEE as a Gasoline Component

Table S1. List of compounds collected from the DIPPR database and used to develop the QSPR models for

SCOPE OF ACCREDITATION

Oil & Gas Application Notebook

HSNO Class Flammable Liquids

Oil & Gas. From exploration to distribution. Week 3 V19 Refining Processes (Part 1) Jean-Luc Monsavoir. W3V19 - Refining Processes1 p.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ANNEX 2, REFERENCE FUELS

ANNEX 3 REFERENCE FUELS. Parameter Unit Limits (1) Test method Minimum Maximum Research octane number, RON

CERTIFICATE OF ACCREDITATION

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

Petroleum Refining Fourth Year Dr.Aysar T. Jarullah

A new simple and robust process FT-NIR Spectrometer with small footprint and extended maintenance interval

DJ Basin Crude Oil Flammability Analysis

Antek Gas Chromatography Products: A Guided Tour Through Industry

Thermal Conversion of Fossil and Renewable Feedstocks

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Transcription:

Our Focus is Quality to Meet Your Standards UcalibrateIT offers a full line of Certified and Custom Made Calibration Standards. We work with leading manufacturers to produce a wide range of Petroleum, Lube, Crude Oil and Polymer Calibration Standards. UcalibrateIT http://www.ucalibrateit.com Page 1 of 67

Our Focus is Quality to Meet Your Standards UcalibrateIT provides Instrument Calibration Standards to Refinery Plants, Chemical Plants, Regulatory Authorities and Private Labs. We partner with the Top US Manufacturers specializing in manufacturing multi-element standards in difficult matrices. All of of our Standards have been formulated to meet the requirements of both ASTM and EPA Methods. All raw materials are checked for chemical purity and the prepared standards analyzed for composition. The results are then compared against the gravimetric figures and are NIST traceable by weight. The Standards are designed specifically for the Analytical Chemist to efficiently and economically analyze for the required properties. We provide instrument calibration standards for the Petroleum, Lubricants, and Polymer industries. The advantages of using UcalibrateIT Standards are: Increased confidence in analytical results by using Method Specific Calibration Standards; Minimum time spent preparing calibration curves, enabling greater productivity by laboratory staff; All Standards are ready to use and available with or without an Internal Standard; Standards are made in large quantities and packaged in glass ampoules, thus ensuring uniform composition and continuity of supply of Standards with the same composition; Daily Calibration Checks and Reference Standards are available, conforming to ASTM Methods; Large quantities are available for the calibration of Process Analyzers. www.ucalibrateit.com Page 2 of 67

CONTENTS Oxygenate Standards for Gas Chromatography Oxygenate Calibration Standards [ASTM D4815, D5599]. 7 Alcohol Calibration Standards [Oxyalcohol, Oxytex]. 8 Oxygenate Daily Check Standards [DCK 1 thru 10]..... 8 Low Level Oxygenate Standard [Low Ox]... 9 MTBE Impurity Standards [ASTM D5441]... 9 Gasoline Reference Standards [CALRR1, 2, 3, FIA]... 10 Reference Blank Standards [BLK-]... 10 Oxygenated Gasoline Standards [NIST] 11 Oxygenates in Water [OXY-W]... 11 Fuel Ethanol Standards [ASTM D5501]... 11 Calibration Standards for Infrared Analyzers [IRQC1 thru 10]... 12 Octane Check Standards [OCT 1 thru 3]... 12 Benzene Check Standards [IRQC 12 thru 15]... 12 PONA and PIANO Standards Quantitative PIANO Mixture [PIANO-1, PIANO-10]... 13 PIANO Paraffins Standard [PIANO-P]... 14 PIANO Isoparaffins Standard [PIANO-I]... 15 PIANO Aromatics Standard [PIANO-A]... 16 PIANO Naphthalene Standard [PIANO-N]... 17 PIANO Olefins Standard [PIANO-O]... 18 Combined PIANO Standards [PIANO-5, PIANO-5-SET]... 19 Quantitative PONA Mixture [PONA-1, PONA-10]... 19 SIMDIS Calibration Standards [ASTM D3710]... 20 Boiling Range Distribution [ASTM D6352]... 20 Polywax Calibration [ASTM D7169].. 20 Engine Oil Volatized at 371 C [ASTM D6417]... 21 Quantitative Alkylate Reference [ALK-1]... 21 SIMDIS Calibration Standards [ASTM D2887]... 22 Benzene, Aromatic and Biodiesel Standards Benzene Purity Standards [ASTM D5713, D4492]... 23 Benzene Calibration Standards [ASTM D3606M, B, D, N, EM, EB, EN]... 24 Benzene Check Standards [ASTM D3606DBE thru DN]... 25 Quality Control Reference Material [D5769 AR1000, 3000, 4000]... 25 Aromatics in Finished Gasoline [ASTM D5769-3-Component Internal]... 26 Aromatics in Finished Gasoline [ASTM D5769 4-Component Internal] 27 Deuterated Internal Standards [ASTM D5769 INT-1, -5, T-1, T-5]... 28 D6550 Olefins in Finished Gasoline [6550CAL, CAL-S, -H, -X, CK, REF]... 29 Total Aromatics in Finished Gasoline [ASTM D5580]... 30 D1319 Aromatics and Olefins by FIA [FIA1000, CALFIA, FIA1000-CY]... 30 Aromatics in Diesel & Aviation Fuels [ASTM D5186]... 31 Aromatics for UOP Methods [UOP720, 744, 931, 831]... 32 Aromatics for UOP Methods [UOP551, 798, 690, 868, 880]... 33 Non-Aromatics for UOP Methods [UOP543, 621, 870].... 34 Biodiesel in Diesel Standards [ASTM D7371 Low Set A, B and C]..... 35 Biodiesel in Diesel Standards [ASTM D7371 High Set A, B and C] 36 Biodiesel in Diesel Standards [ASTM D7371 Ultra High Set A, B and C].. 37 www.ucalibrateit.com Page 3 of 67

CONTENTS Nitrogen and Sulfur Standards Total Sulfur by UV Fluorescence [ASTM D5453]... 38 Sulfur by Oxidative Microcoulometry [ASTM D3120, D3246, and D3961]... 38 Sulfur by Rateometric Colorimetry [ASTM D4045, D6313]... 38 Sulfur by High Temp Combustion [ASTM D1552]... 39 Sulfur by Combustion & Electrochemical Detection [ASTM D6428]... 39 Trace Nitrogen by Combustion & Electrochemical Detection [ASTM D6366]... 39 Trace Nitrogen by Chemiluminescence [ASTM D4629, D5762]... 40 Sulfur and Nitrogen Standards [SNCAL, SNCK]...40 Sulfur by X-ray Spectrometry [ASTM D2622, D4294]... 41 Calibration Set for Low Level Sulfur [CARB XRF1, 2]... 42 Sulfur in Gasoline by X-ray [ASTM D6334]... 42 Trace Sulfur in P-Xylene [PX-R1, R2, DCK, BLANK].. 42 Sulfur Standards in Bulk Quantities... 43 EPA ULSD Qualification Set [EPA PB] 44 Standards for Ultra Low Sulfur Diesel [ASTM D5453]. 44 Standards for Ultra Low Sulfur Diesel [ASTM D7039]... 44 D5623 Mercaptan Sulfur Standards [MSX-14, MSX-1]... 45 D5623 Mercaptan Sulfur Standards [MSX-22] 46 D3227 Mercaptan Sulfide Standards [UOP163]... 46 D5623 Multi-Component Sulfur Standards [MSX-41]... 47 D5623 Mercaptan Sulfur & Thiophene [MSX-1, -M, -THIO]... 48 Organic Chlorides in Crude Oil [ASTM D4929 (b)]... 49 Organic Chloride in Hydrocarbons [ASTM D5808].. 49 Organo Fluorine Standards [FC-1, FP-1, FB-2, FH-1, FT-1]... 49 Chlorine in Mineral Oil Standards [OCR1, 2, CK]... 50 Chlorine & Sulfur in Mineral Oil [OCS-R1, R2, CK]. 50 Physical Properties Standards D2386 Freezing Point Standards [FPZ 50, 45]... 51 D97 Pour Point Standards [PP5, 10, 15, 20, 40, 50].51 D2500 Cloud Point Standards [CP5, 2, 10, 15, 20... 51 D6371/IP309 Cold Filter Plug Point [CFPP1, 2, 3]... 51 D5949 Pour Point for Phase [PP23-PH, PP67-PH, PP17-PH].52 D5773 Cloud Point for Phase [CP14-PH, CP55-PH, CP15-PH]..52 D5972 Freeze Point for Phase [FPZ11-PH, FPZ51-PH, FPZ4-PH]. 52 D92, D93, D56 Flash Point Standards [FP60, 75, 93, 200, 230, TCC40, 55, 60, 68]... 52 IP33/IP170 Abel Flash Point [AB40] 53 Certified Flash Points [FP53ND, 65UD, 110TD, 134HEX, 115TD, 138HEX, 51ND, 67UD] 53 D445 Viscosity Standards [VIS4, 7, 20, 60, 180, 520]... 54 D5482, D5191 Vapor Pressure Standards [VP1 thru 6]... 54 D5188 Vapor Liquid Ratio Temp [VL1, VL2]... 55 Determination of Silicon as Siloxane [SIL-CAL, -CK]... 55 D6045, D848, D6258 Color Standards [SAY, ASTM, 848-03, 6258CAL CK]... 56 D86 Group 1, 2 & 4 Synthetic Distillation Standards [D86-1, -2, -3, 4-1, 4-2]... 57 D850 Distillation Standards [D850-4-1, -2]... 58 D3230 Salt in Crude Standards [3230CAL-QT, 3230DCK-16]. 58 www.ucalibrateit.com Page 4 of 67

CONTENTS Miscellaneous Standards D611 Aniline Point Standards [AP611, AP611E]... 59 D611 Pure Aniline [ANP]. 59 D6304 Water for Coulometric Karl Fischer [KF40, 60, 100, 500, 1000, 5000]... 60 D6304 Water for Volumetric Karl Fischer [KF100, 1000, 5000]... 60 Wear Metal Standards in Oils [D5708, D4927, D5863 WM12, WM21]... 61 D5059 Lead in Gasoline Standards [5059-A, 5059-ISTD]. 62 D3237 Lead in Gasoline Standards [3237-02, -05, -10, X3]. 62 Phosphorous in Gasoline by XRF [P-CAL, P-DCK]... 62 Matrix Oils and Stabilizer Solutions [S20, S75, LS-D] 62 Standards for Underground Fuel Spills [BTEX / MTBE Mix - BTEX-M-200, -2000]... 63 Standards for Underground Fuel Spills [BTEX / MTBE Cal Sets BTEX-CAL-L, -H] 63 Standards for Underground Fuel Spills [GRO-MIX, GRO-CAL] 63 Ion Chromatography Standards [IC-11, IC-4]... 64 Additional information Placing an order... 65 ASTM Test Method Equivalency 66 www.ucalibrateit.com Page 5 of 67

Our Focus is Quality to Meet Your Standards Distributor Price Guide Valid from May,2011 www.ucalibrateit.com Page 6 of 67

OXYGENATE STANDARDS The Clean Air Act of 1995 mandated the use of Reformulated Gasoline in designated areas of the country. The EPA designated two ASTM Methods for the analysis of Oxygenates in Gasoline and the use of a Five Point Calibration Set with DME as the Internal Standard. The following Oxygenate Calibration Sets are packaged in 2 ml ampoules and are certified to +/- 1% relative and are NIST traceable by weight. D4815 Calibration Set D5599 Calibration Set Nominal % Wt. 1-Butanol 0.25 5.0 Methanol 0.5 15.0 Ethanol 0.25 15.0 MTBE 1.0 16.0 ETBE 1.25 15.0 1-Propanol 0.25 5.0 2-Propanol 0.25 5.0 Iso-Butanol 0.25 5.0 DIPE 0.25 5.0 TAME 0.5 15.0 Sec-Butyl Alcohol 0.25- - 5.0 t-amyl Alcohol 0.25 2.5 t-butyl Alcohol 0.5 15.0 DME 5.0 RFA Balance 11 Mixtures 4815CAL Calibration Set Low Calibration Set Nominal % Wt. Methanol 0.25 12.5 Ethanol 0.25 13.0 t-butanol 0.25 12.5 MTBE 0.25 15.0 ETBE 1.0 18.0 TAME 0.10 2.0 DIPE 0.25 5.0 RFA Balance +DME +5.0 1-Butanol 0.25 5.0 8 Mixtures 5599 OXYCAL Calibration Set D4815 Calibration Set Nominal, ppm Wt. MTBE 100, 250, 500, 750 1000 ppm wt. in RFA MTBE 1, 5, 10, 50, 100, 500, 1000 ppm wt. in Isooctane Standards are available in 2 ml or 10 ml ampoules. An internal standard, DME, can be added at 5 % wt. LOWCAL Calibration Set (2 ml) in RFA Calibration Set (10 ml) in RFA Calibration Set (2 ml) in ISO Calibration Set (10 ml) in ISO Nominal % Wt. Methanol 0.25 12.5 Ethanol 0.25 13.0 t-butanol 0.25 12.5 MTBE 0.25 15.0 ETBE 1.0 18.0 TAME 0.10 2.0 DIPE 0.25 5.0 DME 5.0 RFA Balance 8 Mixtures 4815 OXYCAL Calibration Set Standards can also be custom made to any specifications. Please call for details. www.ucalibrateit.com Page 7 of 67

OXYGENATE STANDARDS Alcohol Calibration Standards Alcohol/Ether Nominal % Wt. Alcohol/Ether Nominal % Wt. Isopropanol 0.25 12.0 Isopropanol 0.25 12.0 N-Propanol 0.25 12.0 N-Propanol 0.25 12.0 Iso-Butanol 0.25 12.0 Iso-Butanol 0.25 12.0 Sec-Butanol 0.25 12.0 Sec-Butanol 0.25 12.0 N-Butanol 0.25 12.0 N-Butanol 0.25 12.0 DIPE 0.25 12.0 DIPE 0.25 20.0 t-amyl Alcohol 0.25 12.0 t-amyl Alcohol 0.25 12.0 RFA Balance RFA Balance +DME 5.0 +DME 5.0 Oxyalcohol Calibration Set Oxytex Calibration Set Check Standards The EPA requires calibrations be checked using a Calibration Check Standard at least once per analysis batch or once per 10 samples; and an Independent Reference Standard at least once per analysis batch or at least once per 100 samples. Additionally, the Calibration Check Standard and the Reference Standard must be made from different lots of raw materials and by different persons. Spectrum manufactures Check Standards in compliance with EPA regulations. They consist of a Calibration Check Standard, a Reference Standard and a Reference Blank. DCK-1-(# of days) DCK-2-(# of days) DCK-3-(# of days) DCK-4-(# of days) DCK-5-(# of days) DCK-6-(# of days) DCK-7-(# of days) DCK-8-(# of days) DCK-10-(# of days) 14.9% wt. MTBE/RFA 11.0% wt. MTBE/RFA 5.77% wt. ETOH/RFA 7.77% wt. ETOH/RFA 12.80% wt. TAME/RFA 17.30% wt. TAME/RFA 12.80% wt. ETBE/RFA 17.30% wt. ETBE/RFA 10% wt. ETOH/RFA www.ucalibrateit.com Page 8 of 67

LOW LEVEL OXYGENATE STANDARDS Spectrum offers standards for analyzers used for determination of trace level oxygenates and impurities in hydrocarbon matrices. We supply a comprehensive range of standards in an n-hexane matrix at concentrations ranging from 1 500 ppm wt. Standards can be supplied either in 2 ml glass ampoules, 0.8 Liter cylinders or mini-inert vials. Component Nominal Component Nominal Concentration Concentration ppm wt. ppm wt. Dimethyl Ether 1.0 n-butanol 1.0 Acetaldehyde 1.0 iso-butanol 1.0 Methanol 1.0 iso-butanal 1.0 Ethanol 1.0 Butyraldehyde 1.0 Propyl Ether 1.0 tert-ethyl butyl Ether 1.0 Propionaldehyde 1.0 Di-Iso Propyl Ether 1.0 Isopropanol 1.0 tert-butyl Methyl Ether 1.0 tert-butanol 1.0 tert-amyl Ether 1.0 Propanol 1.0 Acetone 1.0 Methyl Ethyl Ketone 1.0 Valderaldehyde 1.0 Diethyl Ether 1.0 n-hexane Balance LOW-OX 10 LOW-OX CYL 2 ml glass ampoules 0.8 Liter Cylinder * Includes the cost of the cylinder. Refills of the same cylinder cost 550 The standards can be custom made to any specified concentration. Components can be added to suit your needs. ASTM D5441 MTBE Impurity Standard Standards are supplied in 2 ml flame sealed ampoules under a nitrogen atmosphere at the listed concentrations. tert-amyl Methyl Ether 0.5 % wt. n-pentane 0.25% wt. tert-butanol 0.5 % wt. cis-2-pentene 0.25% wt. sec-butyl Methyl Ether 0.25 % wt. trans-2-pentene 0.25% wt. Methanol 0.5 % wt. Di-Isobutylene 0.5 % wt. n-heptane 0.5% wt. C12+ as Triisobutylene 0.5 % wt. Iso-Pentane 0.25 % wt. MTBE Balance MTBE MTBE Impurity Standard www.ucalibrateit.com Page 9 of 67

GASOLINE REFERENCE STANDARDS In early 1996 we conducted an Inter-Laboratory study on a California Phase II Gasoline. The object of the study was to provide a well analyzed standard for checking calibrations and for use in SQC Programs. A total of 25 refinery laboratories participated and the results were statistically analyzed and the mean reported. The Gasoline is packaged in 25 ml glass ampoules under an argon atmosphere. Average results are tabulated below: ASTM Number Test Results D4052 Density @ 60 F 0.7389 D2622 Sulfur by XRF 31 ppm D5453 Sulfur by Chemiluminescence 28 ppm D1319 Aromatics by FIA 22.2 % LV D1319 Olefins by FIA 5.7 % LV D5769 Total Aromatics by GC/MS 21.60 % LV D5580 Total Aromatics 22.43 % LV D5580 Benzene 0.79 % LV D3606 Benzene 0.80 % LV D5769 Benzene by GC/MS 0.81 % LV D5769 Aromatics by GC/MS 21.81 % LV D5599 MTBE by OFID 11.22 % wt. D4815 MTBE 11.15 % wt. D5191 RVP 6.87 psi Evap. Rec. D86 Distillation IBP - 98.1 98.1 10% - 142.9 145.3 50% - 207.2 209.1 90% - 295.0 300.1 EP - 381.3 380.2 CALRR1 1 x 25 ml ampoule CALRR2 5 x 25 ml ampoule CALRR3 Set of 10 x 2 ml ampoules CALFIA Set of 10 for FIA D1319 Gasoline Reference Blank The Gasoline contains less than 10 ppm wt. oxygenates as MTBE. It is packaged in 10x2ml flame sealed ampoules per set. Larger quantities are available in ampoules or bottles. BLK-GAS Gasoline Reference Blank *We also offer the following sets of Blanks: ISO-BLANK BLK-DIESEL BLK-OIL BLK-PX BLK-TOL BLK Nitrogen in Isooctane Blank Diesel Blank DRACOL 10 Oil Blank P-Xylene Blank Toluene Blank Reference Blank for ASTM D3606 www.ucalibrateit.com Page 10 of 67

GASOLINE REFERENCE STANDARDS Oxygenated Gasoline Standards are packaged in 20 ml ampoules. Use of this Standard determines validation of the Oxygen content of fuels. These Standards can be used with ASTM Methods D4815 and D5599. Each set contains one each of the following Oxygenates or can be supplied in custom configurations. NIST149 NIST110 NIST 577 NIST 128 NIST 173 NIST 129 NIST 174 14.9% wt. MTBE in RFA Gasoline 11.0% wt. MTBE in RFA Gasoline 5.77% wt. Ethanol in RFA Gasoline 12.8% wt. TAME in RFA Gasoline 17.3% wt. TAME in RFA Gasoline 12.8% wt. ETBE in RFA Gasoline 17.3% wt. ETBE in RFA Gasoline Oxygenates in Water Calibration Sets are available containing Methanol, MTBE, Acetone and tert-butyl Alcohol in Water at 1, 10, 20, 50, 100, 250 and 500 ppm wt. Calibration Sets can also be custom made to any specification. OXY-W Seven Point Calibration Set ASTM D5501 Fuel Ethanol Standards The increasing use of fuel Ethanol as an Oxygenate Additive in Gasoline has made its composition important to ensure blended fuel complies with Federal and State laws. Our Standards meet the requirements of ASTM D5501. Concentrations below are in weight %: % Methanol % n-heptane % Ethanol Mix #1.01% 6.99% 93% Mix #2.10% 6.90% 93% Mix #3 0.20% 5.8% 94% Mix #4 0.30% 4.7% 95% Mix #5 0.40% 3.6% 96% Mix #6 0.50% 2.5% 97% Mix #7 0.60% 1.4% 98% ETOH5501CK ETOH5501CAL Fuel Ethanol Check Std. (10x2ml) Calibration Set (6x2ml) www.ucalibrateit.com Page 11 of 67

CALIBRATION STANDARDS FOR INFRARED ANALYZERS Infrared Analyzers provide rapid and accurate analysis that can replace the expense and time delay of laboratory analysis. They are used to determine the Gasoline Oxygenate content to ensure product quality and compliance with regulatory authorities. Spectrum offers Calibration Standards for Portable and On-line Infrared Analyzers for the determination of Oxygenates, Benzene and Octane numbers in Gasoline. The standards are either single or multi-component blends of Oxygenates in a Gasoline Matrix and are supplied in 20 ml ampoules. Infrared Calibration Standards IRQC 1 IRQC 2 IRQC 3 IRQC 4 IRQC 5 IRQC 6 IRQC 7 IRQC 8 IRQC10-M IRQC10-E IRQC B 14.9% wt. MTBE / RFA Gasoline 11.0% wt. MTBE / RFA Gasoline 5.77% wt. ETOH / RFA Gasoline 7.77% wt. ETOH / RFA Gasoline 12.80% wt. TAME / RFA Gasoline 17.30% wt. TAME / RFA Gasoline 12.80% wt. ETBE / RFA Gasoline 17.30% wt. ETBE / RFA Gasoline 10.0% wt. MTBE / RFA Gasoline 10.0% wt. ETOH / RFA Gasoline Instrument Blank / RFA Gasoline *Concentrations can be reported in either liquid volume or weight %. Benzene and Oxygen contents are also reported. Octane Check Standards Standards are packaged in 20 ml ampoules and the RON, MON and (R+M)/2 are reported. OCT1 OCT2 OCT3 11.0% wt. MTBE / RFA Gasoline 7.77% wt. ETOH / RFA Gasoline RFA Gasoline Benzene Check Standards Standards are packaged in 20 ml ampoules and can be custom made to any specification. IRQC 12 IRQC 13 IRQC 14 IRQC 15 1.0% LV Benzene, 5% LV Toluene / Isooctane 1.3% LV Benzene / Isooctane 0.8% LV Benzene, 8% LV Ethanol / Isooctane 1.3% LV Benzene, 10% LV Ethanol / Isooctane www.ucalibrateit.com Page 12 of 67

PIANO STANDARD This mixture can be used to determine retention times, indices and response factors for components of complex mixtures. Nominal values of each component are listed. Mixtures are supplied in 2 ml flame sealed ampoules under a nitrogen blanket. Weights are reported as percentages and in grams. PIANO Standard N-Pentane 2.3% Benzene 2.3% N-Hexane 2.4% Toluene 2.4% N-Heptane 2.4% Ethylbenzene 2.4% N-Octane 2.4% p-xylene 3.3% N-Nonane 2.4% Propylbenzene 3.3% N-Decane 2.4% Cumene 1.8% N-Undecane 2.4% 3-Ethyltoluene 1.9% N-Dodecane 2.4% 1,2,4 Trimethylbenzene 1.7% 1,3,5 Trimethylbenzene 1.4% Isopentane 1.9% n-butyl Benzene 2.4% 2-Methyl Pentane 1.7% Iso-Butylbenzene 2.2% 3-Methylpentane 1.7% 1,2,4,5 Tetramethylbenzene 1.2% 2,2 Dimethylpentane 1.6% n-pentylbenzene 2.4% 2,3 Dimethylpentane 1.8% 2,4 Dimethylpentane 1.8% 1-Pentene 2.2% 2,2,4 Trimethylpentane 2.2% 1-Hexene 2.4% 2,3 Dimethyl-2-Butene 2.4% Cyclohexane 2.4% 1-Heptene 2.0% Methylcyclohexane 2.4% 2,3,3 Trimethyl-1-Butene 1.1% Ethylcyclohexane 2.4% 1-Octene 2.4% Propylcyclohexane 2.4% 2-Methyl-1-Heptene 1.3% N-Butylcyclohexane 2.4% 1-Nonene 2.4% N-Pentylcyclohexane 2.4% 1-Decene 2.4% Decalin 1.9% 1-Undecene 2.4% 1-Dodecene 2.4% PIANO-1 PIANO-10 1 x 1ml 10 x 1ml www.ucalibrateit.com Page 13 of 67

PIANO STANDARDS PIANO Paraffins Standard The following PIANO Standards can be used for Detailed Hydrocarbon Analysis and for the following Methods: D6729, D6730, D6733, and D5134. The following Components and Concentrations make up the PIANO Paraffins Standard: Component CAS Number Concentration Wt. % N-Pentane 109-66-0 9.3805 N-Hexane 110-54-3 9.5081 N-Heptane 142-82-5 9.7762 N-Octane 111-65-9 9.5445 N-Nonane 111-84-2 9.0422 N-Decane 124-18-5 9.2452 N-Undecane 1120-21-4 9.3129 N-Dodecane 112-40-3 9.4040 N-Tridecane 629-50-5 8.9068 N-Tetradecane 629-59-4 8.7923 N-Pentadecane 629-62-9 7.0875 PIANO-P PIANO Paraffins Standard - 1ml www.ucalibrateit.com Page 14 of 67

PIANO STANDARDS PIANO Isoparaffins Standard The following PIANO Standards can be used for Detailed Hydrocarbon Analysis and for the following Methods: D6729, D6730, D6733, and D5134. The following Components and Concentrations make up the PIANO Isoparaffins Standard: Component CAS Number Concentration Wt. % Isopentane 78-78-4 2.1598 2,3-Dimethylbutane 79-29-8 0.4426 2-Methylpentane 107-83-5 3.2231 3-Methylpentane 96-14-0 5.2986 2,2-Dimethylpentane 590-35-2 1.7590 2,4-Dimethylpentane 108-08-7 3.6384 2,2,3-Trimethylbutane 464-06-2 3.8709 3,3-Dimethylpentane 562-49-2 1.8405 2-Methylhexane 591-76-4 2.3337 2,3-Dimethylpentane 565-59-3 1.7623 3-Methylhexane 589-34-4 1.5852 3-Ethylpentane 617-78-7 0.5205 2,2-Dimethylhexane ND 1.2986 2,5-Dimethylhexane 592-13-2 3.6687 2,2,3-Trimethylpentane 564-02-3 1.7026 2,4-Dimethylhexane 589-43-5 1.6285 2,3-Dimethylhexane 584-94-1 1.5967 2-Methylheptane 592-27-8 4.3203 4-Methylheptane 589-53-7 3.1640 3-Methylheptane 589-81-1 5.3850 3-Ethylhexane 589-34-4 0.7031 3,3-Dimethylheptane ND 1.6595 2,5-Dimethylheptane ND 5.5593 3,5-Dimethylheptane ND 0.7489 2,3-Dimethylheptane 3074-71-3 1.4660 3,4-Dimethylheptane ND 3.6314 2-Methyloctane ND 3.7096 3-Methyloctane ND 5.5379 3,3-Diethylpentane ND 1.5530 2,2-Dimethyloctane ND 3.2185 3,3-Dimethyloctane ND 3.1402 2,3-Dimethyloctane ND 3.7968 3-Ethyloctane ND 3.6480 2-Methylnonane 871-83-0 3.6687 3-Methylnonane ND 5.6948 PIANO-I PIANO Isoparaffins Standard - 0.1ml www.ucalibrateit.com Page 15 of 67

PIANO STANDARDS PIANO Aromatics Standard The following PIANO Standards can be used for Detailed Hydrocarbon Analysis and for the following Methods: D6729, D6730, D6733, and D5134. The following Components and Concentrations make up the PIANO Aromatics Standard: Component CAS Number Concentration Wt. % Benzene 71-43-2 7.03127 Toluene 108-88-3 4.5064 EthylBenzene 100-41-4 6.6590 m-xylene 108-38-3 2.2344 p-xylene 106-42-3 4.7388 o-xylene 95-47-6 2.2236 Isopropylbenzene 98-82-8 2.1898 n-propylbenzene 103-65-1 4.4891 1-Methyl-3-ethylbenzene 620-14-4 2.1676 1-Methyl-4-ethylbenzene 622-96-8 2.1352 1,3,5-Trimethylbenzene 108-67-8 1.1092 1-Methyl-2-ethylbenzene 611-14-3 2.2158 1,2,4-Trimethylbenzene 95-63-6 2.4987 tert-butylbenzene 98-06-6 4.5264 Isobutylbenzene 538-93-2 4.3482 sec-butylbenzene 135-98-8 2.2168 1-Methyl-3-isopropylbenzene 535-77-3 1.0917 1-Methyl-4-isopropylbenzene 99-87-6 1.0547 1-Methyl-2-isopropylbenzene 527-84-4 1.1096 1-Methyl-3-n-propylbenzene 1074-43-7 2.0801 1-Methyl-4-n-propylbenzene 1074-55-1 2.1910 n-butylbenzene 104-51-8 2.1747 1,2-Diethylbenzene 135-01-3 1.0781 1-Methyl-2-n-propylbenzene 1074-17-5 2.2098 1,4-Dimethyl-2-ethylbenzene 1758-88-9 2.2502 1,3-Dimethyl-5-ethylbenzene 934-74-7 2.1652 1,2-Dimethyl-4-ethylbenzene 934-80-5 2.2212 1,3-Dimethyl-2-ethylbenzene 2870-04-4 1.1274 1,2-Dimethyl-3-ethylbenzene 933-98-2 2.1549 1,2,4,5-Tetramethylbenzene 95-93-2 0.2359 2-Methylbutylbenzene ND 1.1258 trans-1-butyl-1-2-methylbenzene ND 0.7571 n-pentylbenzene 538-68-1 4.4008 t-1-butyl-1,3,5-dimethylbenzene ND 2.1295 t-1-butyl-ethylbenzene ND 2.2036 1,3,5-Triethylbenzene 102-25-0 4.4823 1,2,4-Triethylbenzene 877-44-1 1.0960 n-hexylbenzene 1077-16-3 4.4206 PIANO-A PIANO Aromatics Standard - 0.1ml www.ucalibrateit.com Page 16 of 67

PIANO STANDARDS PIANO Naphthalene Standard The following PIANO Standards can be used for Detailed Hydrocarbon Analysis and for the following Methods: D6729, D6730, D6733, and D5134. The following Components and Concentrations make up the PIANO Napthalene Standard: Component CAS Number Concentration Wt. % Cyclopentane 287-92-3 4.8876 Methylcyclopentane 96-37-7 3.2154 Cyclohexane 110-82-7 5.3106 1,1-Dimethylcyclopentane 1638-26-2 3.4257 cis-1,3-dimethylcyclopentane 2532-58-3 0.5945 trans-1,2-dimethylcyclopentane 2452-99-5 1.4437 trans-1,3-dimethylcyclopentane 2453-00-1 2.7038 Methylcyclohexane 108-87-2 5.6166 Ethylcyclopentane 1640-89-7 3.5158 ctc-1,2,3-trimethylcyclopentane 19374-46-0 1.5596 cct-1,2,4-trimethylcyclopentane ND 3.6982 ctc-1,2,4-trimethylcyclopentane 16883-48-0 1.6450 trans-1,4-dimethylcyclohexane 27195-67-1 3.4980 1-Ethyl-1-methylcyclopentane ND 1.0582 trans-1,2-dimethylcyclohexane 27195-67-1 1.6415 ccc-1,2,3-trimethylcyclopentane 2613-69-6 0.7945 Isopropylcyclopentane 3875-51-2 3.4532 cis-1,2-dimethylcyclohexane 27195-67-1 3.6636 n-propylcyclopentane 2040-96-2 3.6166 ccc-1,3,5-trimethylcyclohexane 1795-27-3 3.4996 1,1,4-Trimethylcyclohexane ND 3.6194 ctt-1,2,4-trimethylcyclohexane 7667-60-9 3.5740 ctc-1,2,4-trimethylcyclohexane 7667-59-6 3.4826 1,1,2-Trimethylcyclohexane ND 3.3152 Isobutylcyclopentane 3788-32-7 3.6658 Isopropylcyclohexane 696-29-7 5.6751 n-butylcyclopentane 2040-95-1 3.6624 Isobutylcyclohexane 1678-98-4 5.5462 t-1-methyl-2-propylcyclohexane ND 3.8141 t-1-methyl-2-(4mp)cyclopentane ND 3.7326 PIANO-N PIANO Napthalene Standard - 0.1ml www.ucalibrateit.com Page 17 of 67

PIANO STANDARDS PIANO Olefins Standard The following PIANO Standards can be used for Detailed Hydrocarbon Analysis and for the following Methods: D6729, D6730, D6733, and D5134. The following Components and Concentrations make up the PIANO Olefins Standard: Component CAS Number Concentration Wt.% 3-Methyl-1-butene 563-45-1 1.9608% 1-Pentene 109-67-1 4.0999% 2-Methyl-1-butene 563-46-2 1.4268% 2-Methyl-1, 3-butadiene 78-79-5 2.4036% trans-2-pentene 646-04-8 1.7990% cis-2-pentene 627-20-3 1.9683% 4-Methylpentene-1 691-37-2 3.3837% 1-Hexene 592-41-6 6.9484% trans-2-hexene 4050-45-7 1.7285% 2-Methylpentene-2 625-27-4 3.3104% cis-2-hexene 7688-21-3 3.8552% 1-Heptene 592-76-7 7.4930% trans-3-heptene ND 3.6247% cis-3-heptene ND 5.7577% trans-2-heptene ND 3.6684% cis-2-heptene ND 5.6638% 1-Octene 111-66-0 7.5936% trans-2-octene ND 1.9463% cis-2-octene 7642-04-8 3.8744% 1-Nonene 124-11-8 7.5680% trans-3-nonene ND 1.8292% cis-3-nonene ND 3.9639% trans-2-nonene ND 1.8292% cis-2-nonene ND 2.7013% 1-Decene 872-05-9 8.0821% PIANO-O PIANO Olefins Standard - 0.1ml www.ucalibrateit.com Page 18 of 67

PIANO STANDARDS All 5 of the PIANO Standards, the PIANO-P, PIANO-I, PIANO-A, PIANO-N and PIANO-O can also be combined into one ampoule: Combined PIANO Standards PIANO-5 All 5 PIANO Standards combined into 0.1 ml In addition, all 5 individual PIANO Standards can be combined with the PIANO-5 Standard: PIANO-5-SET The PIANO-5 Combined Standard with 5 Individual PIANO Stds PONA STANDARD This mixture can be used to determine retention times, indices and response factors for components of complex mixtures. Nominal values of each component are listed. Mixtures are supplied in 1 ml flame sealed ampoules under a Nitrogen blanket. Weights are reported as percentages and in grams. 1-Butene 2.6% Methanol 2.7% 1-Pentene 2.5% Ethanol 2.7% 1-Hexene 2.7% tert-butyl Methyl Ether 2.7% 1-Heptene 2.7% tert-amyl Methyl Ether 2.7% 1-Octene 2.7% tert-butanol 2.7% 1-Nonene 2.7% tert-butyl Ethyl Ether 2.7% 1-Decene 2.7% 1-Undecene 2.7% Cyclopentane 2.8% 1-Dodecene 2.7% Cyclohexane 2.7% Methylcyclohexane 2.7% N-Propane 0.5% Ethylcyclohexane 2.7% N-Butane 2.5% Propylcyclohexane 2.7% N-Pentane 2.7% n-butylcyclohexane 2.7% N-Hexane 2.7% N-Heptane 2.7% Benzene 2.7% N-Octane 2.7% Toluene 2.8% N-Nonane 2.7% Ethylbenzene 2.7% N-Decane 2.7% Propylbenzene 2.7% N-Undecane 2.7% N-Butylbenzene 2.7% N-Dodecane 2.7% N-Pentylbenzene 2.7% PONA-1 PONA-10 1 x 1 ml ampoule 10 x 1 ml ampoules www.ucalibrateit.com Page 19 of 67

SIMDIS ANALYSIS ASTM D3710 Calibration Mix Volume / Volume Spectrum offers Standards covering the Boiling Range Distribution of Gasoline and Gasoline components. Calibration mixes are either in weight / weight or volume / volume. 2-Methylbutane 10.5% p-xylene 14.0% N-Pentane 8.1% n-propylbenzene 4.7% 2-Methylpentane 5.8% n-decane 3.5% N-Hexane 5.8% n-butylbenzene 3.5% 2,4-Dimethylpentane 5.8% n-dodecane 3.5% N-Heptane 10.5% n-tridecane 2.3% Toluene 11.6% n-tetradecane 2.3% N-Octane 5.8% n-pentadecane 2.3% 3710-1 ASTM D3710 Calibration Set ASTM D6352 Calibration Mixture Spectrum offers Standards covering the Boiling Range Distribution of Petroleum Distillate Fractions. They are applicable to fractions having an initial boiling point greater than 174 C to a final boiling point of less than 700 C. Calibration Mixes are Polywax 655 or 1000 dissolved in Carbon Disulfide at a concentration of 1 part to 200 parts. Lower Boiling Point n-paraffins (nominally C10 to C40) are added. The Calibration Mixture covers the range of n-paraffins from C10 to C100. 6352REF Reference Oil per 4 oz bottle ASTM 7169 Calibration Mixture POLY665/1000 Polywax 655/1000 per 1.1 ml www.ucalibrateit.com Page 20 of 67

SIMDIS ANALYSIS High Temperature SIMDIS This Standard can be used to estimate the amount of engine oil volatilized at 371 C in accordance with ASTM D6417. Standards are packaged in 2 ml ampoules, concentrations are weight / weight. N-Octane 0.042% Eicosane 0.043% N-Nonane 0.042% N-Tricosane 0.043% N-Decane 0.043% N-Octacosane 0.042% N-Undecane 0.043% N-Dotriacontane 0.043% N-Dodecane 0.042% N-Tetratriacontane 0.042% N-Tridecane 0.043% N-Hexatriacontane 0.043% N-Tetradecane 0.042% N-Tetracontane 0.041% N-Pentadecane 0.042% N-Tetratetracontane 0.022% N-Hexadecane 0.043% N-Pentacontane 0.022% N-Heptadecane 0.043% N-Dopentacontane 0.020% N-Octadecane 0.042% N-Hexacontane 0.021% N-Nonadecane 0.043% In Carbon Disulfide / Cyclohexane 6417-1 ASTM D6417 Calibration Set Quantitative Alkylate Reference Sample The Standard is a well characterized sample of an actual refinery Alkylation Stream. It can be used to determine retention times, indices and monitor response factors of complex hydrocarbon mixtures. The Standard includes a data sheet listing individual components by weight %, mole % and liquid volume %; retention times and indices for each component; composition by carbon; a calculated boiling point and octane report. A summary of the group types is listed below: GROUP TYPE % Weight % Volume %Mole Aromatics 1.85 1.47 1.51 I-Paraffins 90.23 90.04 87.07 Napthalenes 0.68 0.60 0.59 Olefins 0.013 0.013 0.014 Paraffin 5.02 6.02 9.16 Oxygenates 0.0 0.0 0.0 Unidentified 2.22 1.86 1.65 ALK-1 Alkylate Reference Standard www.ucalibrateit.com Page 21 of 67

SIMDIS ANALYSIS ASTM D2887 Calibration Mix Weight/Weight n-hexane 6.0% n-octadecane 5.0% n-heptane 6.0% n-eicosane 2.0% n-octane 8.0% n-tetracosane 2.0% n-nonane 8.0% n-octacosane 1.0% n-decane 12.0% n-dotriacontane 1.0% n-undecane 12.0% n-hexatriacontane 1.0% n-dodecane 12.0% n-tetracontane 1.0% n-tetradecane 12.0% n-tetrateteracontane 1.0% n-hexadecane 10.0% 2887-1 ASTM D2887 Calibration Set C6-C44 n-pentane 4.03% n-octadecane 3.93% n-hexane 4.94% Eicosane 1.99% n-heptane 4.93% n-tetracosane 1.96% n-octane 7.87% n-octacosane 0.998% n-nonane 8.14% n-dotriacontane 1.01% n-decane 11.90% n-hexatricontane 0.969% n-undecane 11.88% n-tetracontane 0.979% n-dodecane 11.88% n-tetratetracontane 0.983% n-tetradecane 11.91% n-hexadecane 8.92% Other Impurities 0.80% 2887-1P ASTM D2887 Calibration Set C5-C44 n-pentane 5.22% Eicosane 1.05% n-hexane 4.97% n-tetracosane 0.981% n-heptane 5.96% n-octacosane 0.990% n-octane 7.89% n-dotriacontane 0.989% n-nonane 8.05% n-hexatricontane 0.970% n-decane 11.88% n-tetracontane 0.982% n-undecane 11.75% n-tetratetracontane 0.979% n-dodecane 11.89% n-pentacontane 0.492% n-tetradecane 11.82% n-hexacontane 0.491% n-hexadecane 7.88% n-octadecane 3.99% Other Impurities 0.78% 2887-EXT-1 ASTM D2887 Calibration Set - Extended www.ucalibrateit.com Page 22 of 67

BENZENE PURITY STANDARD Spectrum offers two Standards meeting ASTM D5713 and D4492 requirements. Calibration mixtures have the appropriate internal standard added and are also available without internal standard. ASTM D5713 Calibration Mix Weight / Weight Iso-Pentane 100 ppm cis 1,3 Dimethylcyclopentane 100 ppm N-Pentane 100 ppm trans 1,3 Dimethylcyclopentane 100 ppm 2,2 Dimethylbutane 100 ppm Heptane 200 ppm Cyclopentane 100 ppm Methylcyclohexane 100 ppm 2,3 Dimethylbutane 100 ppm Ethylcyclopentane 50 ppm 2 Methylpentane 200 ppm 2,4 Dimethylhexane 100 ppm 3 Methylpentane 200 ppm 1,2,3 Trimethylcyclopentane 50 ppm n-hexane 300 ppm 2,3,4 Trimethylpentane 50 ppm 2,2 Dimethylpentane 100 ppm Methylcyclopentane 200 ppm Toluene 50 ppm 2,4 Dimethylpentane 100 ppm Ethylbenzene 100 ppm 2,2,3 Trimethylbutane 100 ppm p-xylene 100 ppm 3,3 Dimethylpentane 50 ppm m-xylene 100 ppm Cyclohexane 100 ppm Cumene 100 ppm 2-Methylhexane 100 ppm o-xylene 100 ppm 2,3 Dimethylpentane 100 ppm Benzene Balance 1,1 Dimethylcyclopentane 100 ppm 3 Methylhexane 100 ppm Internal Standard - n-octane 10,000 ppm wt. 5713CAL 5713-noISTD D5713 Calibration with Internal Standard D5713 Calibration without Internal Standard ASTM D4492 Calibration Mix Weight / Weight The Calibration Mixture has the same composition as the D5713 Mixture; however, n-nonane has been added as the Internal Standard at 1000 ppm wt. 4492-WISTD 4492-noISTD D4492 Calibration with Internal Standard D4492 Calibration without Internal Standard www.ucalibrateit.com Page 23 of 67

BENZENE STANDARDS ASTM D3606 The EPA has identified Benzene as a major pollutant in Reformulated Gasoline and has designated ASTM Method D3606 for its determination. We offer a set of Calibration Standards meeting all ASTM requirements and are composed of seven individual standards in an Isooctane Matrix. The Standards are packaged in 2ml ampoules and are available with either MEK, 2-Butanol or DME as the Internal Standard. The Standards are NIST Traceable by weight. ASTM D3606 Calibration Set Std # Benzene % LV Toluene % LV Internal Standard 1 5.0 20 +4%LV 2 2.5 15 +4%LV 3 1.25 10 +4%LV 4 0.65 5 +4%LV 5 0.33 2.5 +4%LV 6 0.12 1.0 +4%LV 7 0.06 0.5 +4%LV Calibration Standards with the following Internal Standards are available: Internal Standard 3606M Calibration Set +4% LV MEK 3606B Calibration Set +4% LV 2-Butanol 3606D Calibration Set +4% LV DME 3606N Calibration Set No Internal Standard Additionally, as Ethanol elutes with Benzene, we offer a Calibration Set containing Ethanol. Internal Standard 3606EM10 Calibration Set - 10% Ethanol +4% LV MEK 3606EB10 Calibration Set 10% Ethanol +4% LV 2-Butanol 3606EB6 Calibration Set 6% Ethanol +4% LV 2-Butanol 3606EN5 Calibration Set 5.77% Ethanol No Internal Standard 3606EN7 Calibration Set 7.77% Ethanol No Internal Standard 3606EN10 Calibration Set 10.0% Ethanol No Internal Standard Custom Calibration Standard sets and Calibration Standards are available. Call for details. www.ucalibrateit.com Page 24 of 67

BENZENE STANDARDS ASTM D3606 D3606 Check Standards Accuracy of the Calibration can be monitored daily by the use of Check Standards. We offer the following mixtures: Benzene Toluene Ethanol Internal Std. 3606DBE-(#of days) 1.0 5.0 10.0 +4% 2-Butanol 3606D2B-(#of days) 0.50 3.0 ------- +4% 2-Butanol 3606D3B-(#of days) 1.0 5.0 ------- +4% 2-Butanol 3606DME-(#of days) 1.0 5.0 10.0 +4% MEK 3606D5M-(#of days) 1.0 5.0 ------- +4% MEK 3606D6M-(#of days) 0.50 3.0 ------- +4% MEK 3606DM-(#of days) 1.0 5.0 ------- +4% DME 3606DN-(#of days) 1.0 5.0 ------- No Internal Std. *We also offer Check Standards in 30, 60, 90 and 180 day supplies at the following prices: D3606 Daily Check Standard 60 day set D3606 Daily Check Standard 180 day set *Custom Calibration Standard sets and Check Standards are available. Call for details. ASTM D5769 Quality Control Reference Material Check Standards are available with or without Deuterated Internal Standard mixtures. All concentrations are in weight %. Hexane -12% Toluene -9% Heptane -17% 1,3 Dimethylbenzene -3% Octane -17% 1,2 Dimethylbenzene -3% Decane -12% Ethylbenzene -3% Dodecane -5% 1,2,4 Trimethylbenzene -3% Isooctane -12% 1,2,4,5 Trimethylbenzene -2% Benzene -1% Naphthalene -1% AR1000 AR3000 AR4000 Quality Control Reference Material - 3 component with ISTD Quality Control Reference Material - no Internal Std. Quality Control Reference Material 4 component with ISTD www.ucalibrateit.com Page 25 of 67

AROMATIC STANDARDS ASTM D5769 Aromatics in Finished Gasolines Multi-component Calibration Standards are available for the current version of this Method with or without the 3-Component Deuterated Internal Standard mixture. The Internal Standard mixture is in the ratio Benzene-d6 2ml, Ethylbenzene-d10 2ml and Naphthalene-d8 1 gram. The Standards have the following nominal compositions: Component Std 1 Std 2 Std 3 Std 4 Std 5 Std 6 Wt% Wt% Wt% Wt% Wt% Wt% Benzene 5.2 4.2 2.9 1.6 0.8 0.40 Toluene 19.6 16.0 11.0 6.0 3.0 1.60 Ethylbenzene 5.2 4.0 2.9 1.6 0.8 0.40 m-xylene 6.2 5.0 3.5 1.9 0.9 0.40 p-xylene 6.2 5.0 3.5 1.9 0.9 0.40 o-xylene 6.3 5.0 3.5 1.9 0.9 0.40 Isopropylbenzene 3.0 2.5 1.7 0.9 0.5 0.40 n-propylbenzene 3.0 2.5 1.7 0.9 0.5 0.25 3-Ethyltoluene 3.0 2.5 1.7 0.9 0.5 0.25 4-Ethyltoluene 3.0 2.5 1.7 0.9 0.5 0.25 1,3,5-Trimethylbenzene 3.0 2.5 1.7 0.9 0.5 0.25 2-Ethyltoluene 3.0 2.5 1.7 0.9 0.5 0.25 1,2,4-Trimethylbenzene 5.2 4.0 2.9 1.6 0.8 0.25 1,2,3-Trimethylbenzene 3.2 2.5 1.8 1.0 0.5 0.40 Indan 3.5 2.7 1.9 1.0 0.5 0.25 1,4-Diethylbenzene 3.0 2.5 1.7 0.9 0.5 0.25 n-butylbenzene 3.0 2.5 1.7 0.9 0.5 0.25 1,2-Diethylbenzene 3.0 2.5 1.8 0.9 0.5 0.25 1,2,4,5-Tetramethylbenzene 2.0 1.7 1.2 0.6 0.3 0.25 1,2,3,5-Tetramethylbenzene 2.0 1.7 1.2 0.6 0.3 0.15 Naphthalene 2.5 2.0 1.3 0.7 0.4 0.15 1-Methylnaphthalene 2.5 2.0 1.3 0.7 0.4 0.2 2-Methylnaphthalene 2.4 2.0 1.4 0.7 0.4 0.2 Isooctane ----------------------------------------------------Balance-------------------------------------------------- The 3-Component Internal Standard mixture [Benzene-d6, Ethylbenzene-d10 and Naphthalene-d8] is added to the Calibration Standards in the ratio of 5 parts Internal Standard mixture to 100 parts weight Calibration Standard. 5769CAL-3ISTD 5769CAL-5noISTD 5769CAL-10noISTD Calibration Set with 3 Internal Standards Calibration Set without Internal Standard Calibration Set without Internal Standard www.ucalibrateit.com Page 26 of 67

AROMATIC STANDARDS ASTM D5769 Aromatics in Finished Gasolines Multi-Component Calibration Standards are available for the current version of this Method with the 4- Component Deuterated Internal Standard Mixture. The Internal Standard mixture is in the ratio Benzene-d6-2ml, Ethylbenzene-d10-2ml, Naphthalene-d8 1 gram and Toluene-d8 7ml. The Standards have the following nominal compositions: Component Std 1 Std 2 Std 3 Std 4 Std 5 Std 6 Wt% Wt% Wt% Wt% Wt% Wt% Benzene 5.2 4.2 2.9 1.6 0.8 0.40 Toluene 19.6 16.0 11.0 6.0 3.0 1.60 Ethylbenzene 5.2 4.0 2.9 1.6 0.8 0.40 m-xylene 6.2 5.0 3.5 1.9 0.9 0.40 p-xylene 6.2 5.0 3.5 1.9 0.9 0.40 o-xylene 6.3 5.0 3.5 1.9 0.9 0.40 Isopropylbenzene 3.0 2.5 1.7 0.9 0.5 0.40 n-propylbenzene 3.0 2.5 1.7 0.9 0.5 0.25 3-Ethyltoluene 3.0 2.5 1.7 0.9 0.5 0.25 4-Ethyltoluene 3.0 2.5 1.7 0.9 0.5 0.25 1,3,5-Trimethylbenzene 3.0 2.5 1.7 0.9 0.5 0.25 2-Ethyltoluene 3.0 2.5 1.7 0.9 0.5 0.25 1,2,4-Trimethylbenzene 5.2 4.0 2.9 1.6 0.8 0.25 1,2,3-Trimethylbenzene 3.2 2.5 1.8 1.0 0.5 0.40 Indan 3.5 2.7 1.9 1.0 0.5 0.25 1,4-Diethylbenzene 3.0 2.5 1.7 0.9 0.5 0.25 n-butylbenzene 3.0 2.5 1.7 0.9 0.5 0.25 1,2-Diethylbenzene 3.0 2.5 1.8 0.9 0.5 0.25 1,2,4,5-Tetramethylbenzene 2.0 1.7 1.2 0.6 0.3 0.25 1,2,3,5-Tetramethylbenzene 2.0 1.7 1.2 0.6 0.3 0.15 Naphthalene 2.5 2.0 1.3 0.7 0.4 0.15 1-Methylnaphthalene 2.5 2.0 1.3 0.7 0.4 0.2 2-Methylnaphthalene 2.4 2.0 1.4 0.7 0.4 0.2 Isooctane ------------------------------------------------Balance-------------------------------------------------- The 4-Component Internal Standard mixture, [Benzene-d6, Ethylbenzene-d10, Toluene-d8 and Naphthalene-d8] is added to the Calibration Standards in the ratio of 12 parts Internal Standard mixture to 100 parts weight Calibration Standard. 5769CAL-4ISTD 5769CAL-5noISTD 5769CAL-10noISTD Calibration Set with 4 Internal Standards Calibration Set without Internal Standard Calibration Set without Internal Standard www.ucalibrateit.com Page 27 of 67

AROMATIC STANDARDS ASTM D5769 Internal Standards for GC/MS Internal Standards are available containing Deuterated Ethylbenzene-d10, Naphthalene-d8 and Benzene-d6 as specified in the ASTM Method for the determination of Benzene, Toluene and Total Aromatics in Finished Gasoline by GC/MS. The Internal Standard, used for the sample preparation, is packaged in 5ml flame sealed ampoules and has the following composition: Benzene-d6 Ethylbenzene-d10 Naphthalene-d8 2ml 2ml 1 gram 5769INT-1 5769INT-5 Internal Standard 1x5ml ampoules Internal Standard 5x5ml ampoules The Internal Standard can also be custom packaged to your specifications. ASTM D5769 Internal Standards for GC/MS with Toluene d8 Internal Standard containing Deuterated Ethylbenzene-d10, Naphthalene-d8, Benzene-d6 and Toluene-d8 as specified in the ASTM Method. The Internal Standard used for the sample preparation is packaged in 10ml flame sealed ampoules and has the following composition: Benzene-d6 Ethylbenzene-d10 Naphthalene-d8 Toluene-d8 2ml 2ml 1 gram 7ml 5769INT-T-1 5769INT-T-5 Internal Standard including Toluene-d9 1x10ml ampoule Internal Standard including Toluene-d8 5x10ml ampoules The Internal Standard can also be custom packaged to your specifications. www.ucalibrateit.com Page 28 of 67

OLEFINS STANDARDS ASTM D6550 Olefins in Gasoline by SFC The Method Covers the determination of the total Olefin content of Gasolines by Super-Critical Chromatography (SFC). The application range is 1 to 25% weight total Olefins. We offer two sets of Standards; one is a set of Synthetic Olefins mixtures and the other a set of Gasoline Standards analyzed by consensus analysis. The following Standards are available packaged in 1 ml flame sealed ampoules. 6550CAL-S Calibration Set 1.0, 3.5, 6.0, 8.5, 12.0 % wt. 6550CAL-H Calibration Set 12.0, 17.0, 25.0 % wt. 6550CAL-X Calibration Set 1.0, 3.5, 6.0, 8.5, 12.0, 17.0, 25.0 % wt. 6550CK Check Standard 4.0% wt. Total Olefins [set of 10] The Olefin Standards are made in a Matrix of 75% wt. Isooctane and 25% wt. Toluene [75/25 ISO/TOL]. 6550CAL 6550REF Reference Calibration Set 1.6, 3.7, 4.8, 5.1, 7.5, 8.6, 10.0% wt. Reference Check Standard 10.0% wt. Total Olefins The Reference Standards are made in a Gasoline Matrix and analyzed by consensus analysis. Standards can also be made to your specifications. www.ucalibrateit.com Page 29 of 67

AROMATIC STANDARDS The Air Resources Board of California requires Finished Gasoline to be tested for Total Aromatics using ASTM Method D5580. This Method covers the determination of Benzene, Toluene, Ethylbenzene, Xylenes, C9 and heavier Aromatics, and Total Aromatics. The Internal Standard is 2- Hexanone. The Standards conform to ASTM D5580 and are NIST traceable by weight. We offer a Multi-Component Calibration Standard, Selectivity, Valve Timing and a Daily Check Standard with the following composition. ASTM D5580 Aromatic Calibration Set Nominal Liquid Volume % Std # Benzene Toluene Ethylbenzene O-Xylene 1,2,4-TMB 2-Hexanone Isooctane 1 0.10 15.0 0.50 5.0 0.50 10.0 Balance 2 0.50 5.0 1.0 1.0 10.0 10.0 Balance 3 1.0 10.0 2.5 2.5 2.5 10.0 Balance 4 2.0 2.5 5.0 10.0 1.0 10.0 Balance 5 5.0 1.0 10.0 0.50 5.0 10.0 Balance Daily Ck 1.0 10.0 4.0 4.0 4.0 10.0 Balance Valve Ck 5.0 5.0 5.0 5.0 5.0 10.0 Balance 5580CAL Calibration set includes Selectivity and Valve Timing 5580CAL-E Calibration set includes Ethanol 5580CAL-Px Calibration set includes 0.5 10% LV p-xylene 5580CAL-N Calibration set without Internal Standard 20ml ampoules 5580DCK Daily Check Standard Set of 10 5580DCK-60 Daily Check Standard 60 day set 5580DCK-D Daily Check Standard includes Dodecane 5580SEL Selectivity Standard Set of 10 5580VT Valve Timing Standard Set of 10 ASTM D1319 Aromatics and Olefins by FIA Difficulties with the precision and accuracy of this important test have led to the introduction of a Standard providing a baseline for comparison when used on a regular basis. The Standards are supplied in 2ml ampoules and have the following composition: Toluene 1-Hexene Isooctane 30% LV 10% LV Balance FIA 1000 CALFIA FIA1000-CY FIA Daily Check Standard 10 day Set California Phase II Gasoline FIA 1000 Standard in 800 CC Cylinder www.ucalibrateit.com Page 30 of 67

AROMATIC STANDARDS ASTM D5186 Aromatics in Diesel and Aviation Fuels The analysis of Motor Diesel and Aviation Fuels by Supercritical Fluid Chromatography (ASTM D5186) requires the use of a performance mixture. We supply two such mixtures meeting high and low specifications. The mixtures are supplied in 2ml flame sealed ampoules under a Nitrogen atmosphere. ASTM D5186 Performance Mixture Component % Weight (HIGH) % Weight (LOW) Tetralin 3.0 1.0 Naphthalene 2.0 1.0 Toluene 20.0 8.0 Hexadecane 75.0 90.0 5186-10 Low Concentration 5186-25 High Concentration ASTM D5186 Calibration Set An Inter-Laboratory study was conducted using Diesel Fuel. A total of 11 Refinery and Independent Laboratories analyzed the Standards for both Total Aromatics and Poly-Nuclear Aromatics and the results were statistically analyzed. The standards are packaged in 2ml glass ampoules under a Nitrogen atmosphere. The means are tabulated below: LOW RANGE Standard # Total Aromatics Poly-Nuclear Aromatics 1 2.06 % wt 0.23 % wt 2 5.64 % wt 0.89 % wt 3 11.0 % wt 2.06 % wt 4 14.6 % wt 2.50 % wt 5 21.6 % wt 4.31 % wt HIGH RANGE Standard # Total Aromatics Poly-Nuclear Aromatics 1 14.6 % wt 2.50 % wt 2 21.6 % wt 4.44 % wt 3 26.6 % wt 6.00 % wt 4 32.6 % wt 7.50 % wt 5 38.6 % wt 11.8 % wt 5186CAL HI 5186CAL LO 5186 Calibration Set Hi Range 5186 Calibration Set Lo Range www.ucalibrateit.com Page 31 of 67

AROMATIC STANDARDS Aromatic Standards for UOP Methods The following standards for UOP Methods for Trace Impurities in Aromatic Hydrocarbons and are packaged in 2 ml flame sealed ampoules: UOP 720 Impurities in High Purity P-Xylene The Standards contain o-xylene, m-xylene, Ethylbenzene, n-undecane (ISTD) at concentrations of 0.1 % wt in a p-xylene Matrix. UOP720 Xylene Impurity Standard UOP UOP 744 Aromatics in Hydrocarbons The Standard contains n-heptane, Benzene, Toluene, Mixed Xylene, 1-Methyl-2-Ethylbenzene and 1,2,3,4,-Tetramethylbenzene at concentrations 10 25 % wt. UOP744 Aromatics in Hydrocarbons UOP 931 Impurities in Mixed Xylenes The Standard contains Benzene, Toluene, 1-Methyl-2-Ethylbenzene, n-undecane in an n-heptane Matrix at concentrations of 2 % wt. UOP931 Mixed Xylenes Impurity Standard UOP 831 Hydrocarbons in Sulfolane The Standard contains Benzene, Toluene, Ethylbenzene, Cumene and n-nonane in a Sulfolane Matrix at concentrations of 10 ppm wt. UOP831 Hydrocarbons in Sulfolane www.ucalibrateit.com Page 32 of 67

AROMATIC STANDARDS Aromatic Standards for UOP Methods UOP 551 Hexanes in Olefin-Free Gasoline The Standard contains n-hexane, Benzene, Toluene, Ethylbenzene, o-xylene, m-xylene, p-xylene at concentrations of approximately 14% wt. UOP551 Hexanes in Gasoline UOP 798 Trace p-diethylbenzene in C8 Aromatics The Standard contains p-diethylbenzene and Indane in a p-xylene Matrix at a concentration of 5 ppm wt. UOP798 Trace p-diethylbenzene UOP 690 Octanes in Olefin-Free Gasoline The Standard contains n-octane, Benzene, Toluene, Ethylbenzene, o-xylene, m-xylene and p- Xylene at concentrations of approximately 14% wt. UOP690 Octanes in Gasoline UOP 868 Trace Saturates in High Purity Aromatics The Standard contains Cyclohexane, n-hexane, Methylcyclohexane, N-Heptane, Ethylcyclohexane, n-octane, Propylcyclohexane, n-nonane, Butylcyclohexane, n-decane in a Toluene Matrix at a concentration of 500 ppm wt. UOP868 Saturates in Gasoline UOP 880 Distillate Reformer and Reformate Standards UOP880-RFRMR UOP880-RFRMR-4 UOP880-RFRMT UOP880-RFRMT-4 Reformer Standard - 10 x 2 ml ampoules Reformer Standard 4 oz. bottle Reformate Standard 10 x 2 ml Reformate Standard 4 oz. bottle www.ucalibrateit.com Page 33 of 67

NON-AROMATIC HYDROCARBON STANDARDS UOP 543 Non-Aromatic Hydrocarbons in High-Purity Aromatics by Gas Chromatography The Standard contains Undecane, Benzene and Toluene in a P-xylene Matrix in a concentration of approximately 100 PPM and are packaged in 2 ml flame sealed ampoules. UOP543-IMP Non-Aromatic Hydrocarbon Standard UOP 543 Non-Aromatic Hydrocarbons Response Factor Standard The Standard contains N-Dodecane in a Toluene Matrix. UOP543-RF Non-Aromatic Hydrocarbons Response Factor Standard UOP 621 UOP 621 Non-Aromatic Hydrocarbons in High-Purity Aromatics by Gas Chromatography The Standard contains: Pentane; N-Hexane; Heptane; N-Octane; Nonane; N-Decane; Undecane; Dodecane; Tridecane; Tetradecane; Pentadecane; Hexadecane; Heptadecane; Octadecane; Nonadecane and Eicosane in a concentration of approximately 6 % WT. UOP 621 NON-AROMATIC HYDROCARBONS IN HIGH-PURTITY AROMATICS BY GCHROMATOGRAPHY Boiling Point of Hydrocarbons Standard UOP 870 Non-Aromatic Hydrocarbons in High-Purity Aromatics by Gas Chromatography The Standard contains Pentane; N-Hexane; Heptane; Methylcyclohexane; N-Octane; Ethylcyclohexane; Nonane; Indan; N-Decane; Benzene; Toluene; P-xylene and Cumene in a concentration ranging from 0.3 %WT to 18.848 %WT. UOP 870 Carbon Distribution of Paraffins/Naphthenes Aromatics Std www.ucalibrateit.com Page 34 of 67

BIODIESEL STANDARDS ASTM D7371 Biodiesel Standards ASTM D7371 is used to determine the biodiesel content in Diesel fuel by Furrier Transfer Infrared (FTIR). We offer the following Calibration Standards and Daily Check Standards, packaged in 5ml ampoules. D7371 Low Calibration Set A D7371 Low Calibration Set B Biodiesel [vol%] Solvent Biodiesel [vol%] Solvent 0.00 DCCF-Low 10.00 DCCF-Low 0.25 DCCF-Low 12.50 DCCF-Low 0.50 DCCF-Low 15.00 DCCF-Low 1.00 DCCF-Low 17.50 DCCF-Low 2.50 DCCF-Low 20.00 DCCF-Low 5.00 DCCF-Low 25.00 DCCF-Low 7.50 DCCF-Low 30.00 DCCF-Low 10.00 DCCF-Low Set A, Mixtures 1-8 Set B, Mixtures 8-14 7371CAL-L-A 7371CAL-L-B D7371 Low Calibration Standard Set A [0.00-10.00] 5ml ampoules D7371 Low Calibration Standard Set B [10.00-30.00] 5ml ampoules D7371 Low Calibration Set C Biodiesel [vol%] Solvent 30.00 DCCF-Low 50.00 DCCF-Low 70.00 DCCF-Low 80.00 DCCF-Low 90.00 DCCF-Low 95.00 DCCF-Low 97.00 DCCF-Low 99.00 DCCF-Low 99.80 DCCF-Low Set C, Mixtures 14-22 7371CAL-L-C 7371DCK-L 7371DCK-H 7371DCK-UH D7371 Low Calibration Standard Set C [30.00-99.80] 5ml ampoules D7371 Daily Check Standard Low [*Biodiesel / Solvent] 10x5ml set D7371 Daily Check Standard High [*Biodiesel / Solvent] 10x5ml set D7371 Daily Check Standard Ultra High [*Biodiesel/Solvent] -10x5ml set *Upon ordering our Daily Check Standards, customer must specify the Biodiesel % and Solvent required. www.ucalibrateit.com Page 35 of 67

BIODIESEL STANDARDS ASTM D7371 Biodiesel Standards ASTM D7371 is used to determine the biodiesel content in Diesel fuel by Furrier Transfer Infrared (FTIR). We offer the following Calibration Standards and Daily Check Standards, packaged in 5ml ampoules. D7371 High Calibration Set A D7371 High Calibration Set B Biodiesel [vol%] Solvent Biodiesel [vol%] Solvent 0.00 DCCF-High 10.00 DCCF-High 0.25 DCCF-High 12.50 DCCF-High 0.50 DCCF-High 15.00 DCCF-High 1.00 DCCF-High 17.50 DCCF-High 2.50 DCCF-High 20.00 DCCF-High 5.00 DCCF-High 25.00 DCCF-High 7.50 DCCF-High 30.00 DCCF-High 10.00 DCCF-High Set A, Mixtures 23-30 Set B, Mixtures 30-36 7371CAL-H-A D7371 High Calibration Standard Set A [0.00-10.00] 5ml ampoules 7371CAL-H-B D7371 High Calibration Standard Set B [10.00-30.00] 5ml ampoules D7371 High Calibration Set C Biodiesel [vol%] Solvent 30.00 DCCF-High 50.00 DCCF-High 70.00 DCCF-High 80.00 DCCF-High 90.00 DCCF-High 95.00 DCCF-High 97.00 DCCF-High 99.00 DCCF-High 99.80 DCCF-High Set C, Mixtures 36-44 7371CAL-H-C D7371 High Calibration Standard Set C [30.00-99.80] 5ml ampoules www.ucalibrateit.com Page 36 of 67