QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL

Similar documents
INCOMING INSPECTION DELEGATION GUIDELINES FOR ALENIA SUPPLIERS PROGRAM: ALL

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK

Implementation procedure for certification and continued airworthiness of Beriev Be-200E and Be-200ES-E

PROCUREMENT SPECIFICATION FOR CNP19 CHERRY RIVETLESS NUT PLATE

Offshore manufacturing and fabrication: guidelines for heavy trailers (class TC and TD)

Information for the Certification of Weld Shops in Rail Vehicle Construction According to DIN EN

Renewable Fuels Association One Massachusetts Ave. NW Suite 820 Washington, DC Telephone: (202) Fax: (202)

Guideline of the Railway Vehicles Coordination Committee (Draft Guideline DVS 1619)

Diesel Exhaust Fluid Certification Program Overview FEBRUARY 2009 REVISION 01

PROGRAM: C27J QUALITY REQUIREMENTS FOR ALENIA SUB-CONTRACTORS

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

Certification Scheme

Certification Scheme

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

To facilitate the extension of departmental services through third party testing organizations as provided for by CRS (b)

501 CMR: EXECUTIVE OFFICE OF PUBLIC SAFETY

The IFSQN ISO Implementation Package Start Up Guide

501 CMR: EXECUTIVE OFFICE OF PUBLIC SAFETY

THE MINISTER OF INDUSTRY AND TRADE, b. that for this purpose, it is necessary to issue a decree of the Minister of Industry and Trade.

ECE TYPE-APPROVAL CERTIFICATE

1.1 All testing apparatus shall be periodically checked and calibrated and records of such checks/calibration shall be maintained.

Certification Scheme

2009 FORMULA TWO TECHNICAL REGULATIONS

this Supplier Quality Manual.

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES

CHAPTER 168. EVALUATE AN EASA SUPPLEMENT TO A REPAIR STATION S MANUAL/QUALITY CONTROL MANUAL

2010 FORMULA TWO TECHNICAL REGULATIONS

Control, Safe Use and Operation of Excavators, Loaders and Earth Moving Equipment

Centerwide System Level Procedure

Rule No. 1. Scope Definitions Periodicity of technical inspections Technical inspection Inspection requirements...

BQ-9000 Quality Management System. Producer Requirements

Control, Safe Use and Operation of Road-Rail Plant

Tanks: Informal Working Group on the inspection and certification of tanks

Abu Dhabi Conformity Assessment Scheme for Electric Vehicle Supply Equipment

PUBLIC Law, Chapter 539 LD 1535, item 1, 124th Maine State Legislature An Act To Create a Smart Grid Policy in the State

RULES PUBLICATION NO. 4/P IC ENGINES AND ENGINE COMPONENTS SURVEY AND CERTIFICATION July

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

REQUEST FOR PROPOSAL

Microgeneration Installation Standard: MCS

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

Palabora Copper REQUEST FOR PROPOSAL SUPPLY AND DELIVERY OF BEARINGS AND ACCESSORIES RFP.PC.2017/18 PART 1 PROPOSAL INFORMATION AND CONDITIONS

ANSI/AGRSS Automotive Glass Replacement Safety Standard

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

SPECIFICATIONS FOR MOTOR OPERATED VALVES

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

Municipality Generator Interconnection Application Single Meter Application Part I

Introducing the world's most reliable solar panel. Company presentation / Solar panels

Certification Scheme

1 [94. NOISE LIMIT FOR GENERATOR SETS RUN WITH DIESEL

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

BQ-9000 Quality Management System Testing Laboratory Requirements

HYDRAULIC HOSES AND HOSE KITS

APPLICATION FOR PRODUCT / ECO-LABELLING CERTIFICATION. GPS Coordinates. GPS Coordinates. Fax No. H/P No.

PRODUCT CERTIFICATION PROGRAM POLICY HANDBOOK

Transportation of Hazardous Commodities HM 216B Update. Jay Grove (for Karl Alexy) GATX

PROCEDURE. Operative Date: 22/12/2016 Department: HSEC. Revision: Author: D Steel CONTENTS

Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts

THE CONNECTICUT LIGHT AND POWER COMPANY, DBA EVERSOURCE ENERGY. PARTIAL STREET LIGHTING SERVICE RATE 117 Page 1 of 5

ANSI/AGRSS Automotive Glass Replacement Safety Standard

National Board Update

DNVGL-CP-0110 Edition March 2016

NCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles

Forensic Sciences Chapter ALABAMA DEPARTMENT OF FORENSIC SCIENCES ADMINISTRATIVE CODE CHAPTER IGNITION INTERLOCK RULES

Foreign Part-145 approvals - User Guide for Applicants & Approval Holders UG.CAO

ISO INTERNATIONAL STANDARD. Aerospace Airframe needle roller, cylindrical roller and track roller bearings Technical specification

RSPO Accreditation and Certification. Requirements for Group Certification. 26 August 2010

Effective Date: March 2018 Void After: March 2019

CITY OF PORTSMOUTH PURCHASING DEPARTMENT PORTSMOUTH, NEW HAMPSHIRE. Annual Fuel Bid - #01-18 INVITATION TO BID

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

WELLINGTON, NEW ZEALAND. PURSUANT to section 152 of the Land Transport Act Land Transport Rule: Vehicle Standards Compliance 2002

STANDBY EMERGENCY CNG/LPG GENERATOR

2. 0 Test Records - All records of analysis and tests shall be kept in suitable forms approved by the Bureau of Indian Standards.

BQ-9000 Quality Management System. Accredited Producer Requirements

ISCC s Risk based Certification Approach for Waste and Residues

Main Roads Technical Standard

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

BQ-9000 Quality Management System. Marketer Requirements

ABB Breaker Service Center. Factory Circuit Breaker Refurbishment Service

TYPE APPROVAL CERTIFICATE

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels

Regulatory update on implementation of the 0.50% sulphur limit for international shipping

Airworthiness Directive

(Non-legislative acts) DECISIONS

City of Storm Lake Fire Department Heavy Rescue Specifications

SFI SPECIFICATION 18.1 EFFECTIVE: JUNE 17, 1999 *

Consistent implementation of the 2020 sulphur limit and work to further address GHG emissions from international shipping

Guideline for the Queensland Rally Vehicle Registration Scheme

TOPAS 2130A (Draft v3)

LEGAL MEMORANDUM OF THE TOWN OF WEST WARWICK IN SUPPORT OF RHODE ISLAND PUBLIC TOWING ASSOCIATION, INC S PETITON FOR DECLARATORY JUDGMENT

SACRAMENTO REGIONAL SOLID WASTE AUTHORITY (SWA)

UNITED STATES COAST GUARD OCEAN ENGINEERING DIVISION WASHINGTON, D.C. JANUARY 2011 SPECIFICATION FOR THE MANUFACTURE

Standard Specification for Threaded Couplings, Steel, Black or Zinc-Coated (Galvanized) Welded or Seamless, for Use in Steel Pipe Joints 1

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Sumitomo Rubber Industries, Ltd., Grant of Petition for Decision. AGENCY: National Highway Traffic Safety Administration (NHTSA),

POLLUTION PREVENTION AND RESPONSE. Application of more than one engine operational profile ("multi-map") under the NOx Technical Code 2008

BUSWAY Low Voltage (Pow-R-Flex)

Recommendations Multipin connector Wired mode (permanent and pulse signal) Positioning mode

Recordkeeping Requirements of the Federal Motor Carrier Safety Regulations

VEHICLE MAINTENANCE PROGRAM

Transcription:

QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL THE CONTENT OF THIS DOCUMENT IS THE PROPERTY OF ALENIA AERONAUTICA S.p.A. THIS DOCUMENT IS SUPPLIED IN CONFIDENCE AND COMMERCIAL SECURITY ON ITS CONTENTS MUST BE MAINTAINED. IT MUST NOT BE USED FOR ANY PURPOSE OTHER THAN THAT FOR WHICH IT IS SUPPLIED NOR THE INFORMATION CONTAINED IN IT MAY BE DISCLOSED TO UNAUTHORIZED PERSONS. IT MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT PERMISSION IN WRITING FROM ALENIA AERONAUTICA S.p.A. 1 / 10

MODIFICATION DESCRIPTION ISSUE DATE MODIFIED PAGES APPROVAL Rev. C March 2002 New Issue C. Scafa Rev. D June 2004 Quality Requirements compliant with new Suppliers Quality documentation See cover page 2 / 10

INDEX 0.0 Reference Documents 1.0 Quality System 2.0 Incoming Inspection Delegation 3.0 Suspension of Incoming Inspection Delegation 4.0 Approval of Manufacturers 5.0 Renewal of Manufacturers Qualifications 6.0 Flow Down of Alenia Requirements 7.0 Right of Surveillance 8.0 Traceability 9.0 Configuration Control 10.0 Incoming inspections and tests 11.0 Handling, Warehousing and delivery 12.0 Products Certification 13.0 Customer Coordinator 14.0 Quality Documentation 15.0 Quality Indicators 16.0 Preventive Actions 17.0 Corrective Actions 18.0 Quality Assurance Plan 19.0 Activities performed by JIT-S.P. in Alenia Plants 20.0 Parts furnished by Alenia 21.0 Training 22.0 Audit 3 / 10

0.0 REFERENCE DOCUMENTS The following documents shall be considered as a guideline: ISO 9001:2000 EN 9120 / AS 9120 AS 9120 IAY G05 C QFRA/01P.435 QFRA/02P.187 Quality Management Systems - Requirements Aerospace series Quality management systems requirements for stockist distributors Quality Management System Requirements For Suppliers (for the paragraphs applicable to class E1) Quality Requirements for Stockist Distributors Incoming Inspection Delegation Guidelines for Alenia Suppliers 1.0 QUALITY SYSTEM JIT-SP shall maintain a quality management system in compliance with international rules ISO 9001:2000, EN 9120, and Alenia documents IAY G05 C and QFRA/01P.435. 2.0 INCOMING INSPECTION DELEGATION JIT-SP shall obtain and shall maintain Alenia Incoming Inspection Delegation in accordance with Alenia document QFRA/02P.187 Incoming Inspection Delegation Guidelines for Alenia Suppliers, in particular concerning quality level of the part subjected to the services. Delegated activities shall be contractually requested and reported in a specific document called DELEGATED QUALITY CONTROL PLAN Alenia Aeronautical Company will give Incoming Inspection Delegation ( IID) authorization considering: - On-site quality assessment result related IID process - Customer s coordinator appointment 3.0 SUSPENSION OF INCOMING INSPECTION DELEGATION In case of JIT - SP responsibility for scraps (one major defect occurrence or minor defects quality indicator under the agreed value) incoming inspection delegation shall be suspended by Alenia and the Alenia Source Inspection shall be performed (considering associated relevant cost ), until a Supplier Quality Improvement Plan is submitted to the Alenia approval. 4.0 APPROVAL OF MANUFACTURERS / DISTRIBUTORS JIT - S.P. will purchase products only from Alenia imposed Manufacturers/Distributors at the conditions already negotiated by Alenia. 4 / 10

In case of necessity, it is possible to purchase products by Manufacturers/Distributors not imposed by Alenia only after Alenia written authorization. In this case JIT- S.P. shall assure that: - The manufacturers/distributors are included in the applicable Alenia Customer Qualified Product List (QPL) when requested by Technical Specification, - The Manufacturers/Distributors are included in the Alenia Customer Qualified Suppliers List For the interested product, it is JIT - S.P. responsibility to maintain the Service Provider Authorisation. (In case of Boeing Programs JIT - S.P. shall be approved by BOEING and, if applicable, reported in the document D1 4426). 5.0 RENEWAL OF MANUFACTURERS QUALIFICATION JIT - S.P. shall include the Alenia imposed manufacturers in the list of approved suppliers, at the condition already stipulated by Alenia in the relevant contracts. lt shall be JIT - S.P. responsibility to maintain their qualification in accordance with procedures included in the Q.A.P. The relevant manufacturers Quality Indicators shall be annually sent to Alenia. 6.0 FLOW DOWN OF ALENIA REQUIREMENTS JIT - S.P. shall assure that all Alenia quality requirements are included in the Purchase Orders sent to the manufacturers. These requirements will include but not limited to: - Inspection and test. - Specifications and standards - Test Reports and Certificates of Conformance. - Special testing (if required). - Document change control. - Preservation, packaging and storage. - Labels and identification The above mentioned requirements will be included in the P.O. in accordance with a procedure described in the Quality Assurance Plan. 7.0 RIGHT OF SURVEILLANCE JIT - S.P. shall provide the right of access to Alenia personnel and personnel of any Alenia's Customers or Regulatory Agencies to perform Source Inspections and/or Audits in all areas of its facilities, in any independent testing laboratories used for the program, and in all related manufacturers plants. 5 / 10

8.0 TRACEABILITY JIT - S.P. shall assure and shall maintain full lot traceability to the original manufacturer of all products delivered to Alenia in accordance with a procedure shown and described into the Quality Assurance Plan. Commingling of manufacturing lot shall be strictly prohibited. A relevant procedure shall describe the applied traceability process. 9.0 CONFIGURATION CONTROL JIT - S.P. shall delivery to Alenia only the products configuration requested by Alenia. Any changes shall be submitted to Alenia Engineering for approval before the product procurement and stocking. 10.0 INCOMING INSPECTIONS AND TEST Inspections and Tests Responsibility JIT - SP shall be responsible to assure that all the inspections and tests required in the relevant Alenia Delegated Quality Control Plans, will be completely and correctly performed. The Delegated Quality Control Plans shall be managed and handled in accordance with a JIT - S.P. procedure shown and described into the Quality Assurance Plan. Alenia will reserve the right to assist and to survey the tests and to take away samples to repeat the same tests. JIT - S.P. shall maintain quality and tests documentation for each lot of each product delivered to Alenia and will place on file all the evidences and tests results together with Manufacturers Test Reports in accordance with a procedure described in the Quality Assurance Plan. Approved Laboratories The characteristics of all product delivered to Alenia will be tested by Third Party" certified / Alenia qualified / Customer qualified Laboratories for the required tests. Certification and Approval documentation shall be submitted to Alenia. Sample Size Al manufacturing lots delivered to Alenia shall be sample sized. The sample size will be in accordance with document ANSI / ASQC Z1.4 (AQL = 1,5 / Inspection Level = Normal modified to accept on zero (0) and reject on one (1) or in accordance with the document referenced into the relevant Alenia Delegated Quality Control Plan. 6 / 10

11.0 HANDLING, WAREHOUSING AND DELIVERY Una Società Finmeccanica All the parts to be delivered to Alenia will be stocked in a warehouse and placed into an appropriate dedicated area such that they are preserved from any possible quality products decrease. In particular the following characteristic shall be assured: - First in -first out (FIFO). - Periodic inspection for the prevention of deterioration due to environmental condition. - Management and checking of parts subjected to shelf life in order to assure, before delivery, that at least 75% of shelf- life is still available. JIT - S.P. will manage and check the parts subjected to shelf life in accordance with JIT - S.P. procedure described in the Quality Assurance Plan. 12.0 PRODUCTS CERTIFICATION JIT - S.P. will take care and will be responsible to certify products for each shipset delivered to Alenia according to the relevant drawing, specifications and Incoming Inspection Delegation procedures. JIT - S.P. will maintain a dedicated file of all the certifications document such as: Certificate of Conformance, Test Reports, Alenia Delegated Quality Control Plans, Source Certificate of Conformance, Source Test Report etc. These documents will not be delivered to Alenia. All record will be available and will be provided to Alenia upon request at no additional charge within 24 hours. Documents file management (including all relevant certifications) shall be in accordance with JIT - S.P. procedure described in the Quality Assurance Plan. 13.0 CUSTOMER S COORDINATOR Customer s Coordinator shall be JIT - S.P. Quality Inspectors authorised by Alenia to assure that the relevant Alenia Delegated Quality Control Plans have been fully performed. Customer s Coordinator stamp shall be used as objective evidence. JIT - S.P. will take care of the Customer s Coordinator training. JIT - S.P. will submit to Alenia for approval the candidate Customer s Coordinator. Alenia on site assessment (audit) will perform to verify the process described in the Quality Assurance Plan. After closure of all corrective actions and Process Test Phase (including Alenia double check activity), the Customer s Coordinator will be appointed and authorised to perform and validate the Delegated Quality Control Plans (Incoming Inspection Delegation). 7 / 10

14.0 QUALITY DOCUMENTATION All the products to be delivered to Alenia will be adequately packaged, labelled with the manufacturer lot number and stamped by the Customer Coordinator. All the products will be delivered to Alenia with the Shipping Document stamped by an authorised customer coordinator. The Customer Coordinator stamp will assure that the part was inspected according to the relevant Delegated Quality Control Plan and no discrepancies were detected. Note:(Traceability between the Delegated Quality Control Plan and the Shipping Document will be assured using the same reference number including the Manufacturer lot number.) 15.0 QUALITY INDICATORS Alenia used Quality Indicators JIT - S.P. shall agree the following quality rating indicators, and the related minimum values, used by Alenia to determine the quality level of products delivered by JIT - S.P. The defect shall be classified as follows : - Major Defects - Minor Defects Major defects are defined all the defects affecting the characteristics of the product. Minor defects are defined all the defects that doesn't affect the characteristics of the product (i.e. documentation, packing etc.) Minimum values will be: Major Defects: ZERO (0) Minor Defects : Quality Rating greater than or equal the average value achieved in the previous year. Note : Basic Minor Defect Quality Rating shall be agreed between Alenia and JIT - S.P. JIT - S.P. will commits itself, to improve Minor Defects Quality Indicator performing the necessary corrective and preventive actions. In case of major defect (scrap affecting the characteristics of the product), Incoming Inspection Delegation shall be suspended by Alenia and the consequent Alenia Source Inspections costs will be considered by Purchasing Department. 8 / 10

J IT - S.P. Quality Indicators JIT -S.P. will take care to measure and continually control suppliers with appropriate quality indicators to be sure that Alenia quality requirements will be meet. JIT - S.P. will detail in the Quality Assurance Plan the Quality Rating Procedure and the relevant quality indicators. 16.0 PREVENTIVE ACTIONS JIT- S.P. will deliver only products that 100% conform with Product Definition, related Drawing and Technical specification and in accordance with Alenia Quality Requirements. To assure this requirements, JIT - S.P. shall describe in the Quality Assurance Plan the preventive actions considered necessary (for example: procedure to maintain Manufacturers Qualification, Quality Rating Indicators procedure, etc.). 17.0 CORRECTIVE ACTIONS Responsibility : JIT -S.P. will be fully responsible for any nonconforming products delivered to Alenia including relevant costs. Root Cause Analysis : JIT - S.P., in case of any product nonconformance (also minor) concerning either the parts or the relevant documentation shall perform a deep root-cause analysis in order to determine the cause. When the causes will be detected, JIT - S.P. is responsible to make corrective and preventive actions in order to avoid the same problem in the future. 18.0 QUALITY ASSURANCE PLAN JIT - S.P. shall submit to Alenia a Quality Assurance Plan for approval, including procedures and methods used to assure compliance with Alenia requirements. Cross Reference Matrix (Alenia Requirements/JIT - S.P. Procedure) shall be part of the Quality Assurance Plan. In particular the Quality Assurance Plan will detail the methods used to assure that only product conforming to 100% will be delivered to Alenia. Quality Assurance Plan appendix shall include the applicable Alenia Delegated Quality Control Plans 9 / 10

19.0 J.I.T S.P. ACTIVITIES PERFORMED IN ALENIA PLANTS Una Società Finmeccanica JIT S.P. must provide, and agree with Alenia, a detailed flow chart and a procedure, with all the activities that shall be performed in Alenia plants. 20.0 PARTS FURNISHED BY ALENIA JIT - S.P. must provide, and agree with Alenia ( i.e. during Test Phase ), a procedure regarding incoming inspection activities and management of parts coming from Alenia and already accepted and certified by Alenia Q.C. 21.0 TRAINING JIT- S. P. must provide, and agree with Alenia, a procedure regarding the training of the involved people. 22. 0 AUDIT JIT- S.P. shall issue and agree with Alenia an annual internal audit plan to verify the application of the process. 10 / 10