WARNING: Do not use pumps for gasoline or highly flammable products! Do not use pumps for water based fluids, solvents or chemicals!

Similar documents
OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

New & Improved VariFlo Plural Component Equipment. Low Pressure Polymer Dispensing Equipment

MULTIPOSITION AIR CYLINDER

MODEL 1385 & 1385-H Professional Rotary Drum Pump

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Installation, Operating and Maintenance Manual

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Customer Support

Air Control Kits INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

FPS-500. Fuel Polishing System Eliminates Microbial Contamination. Operating Manual

2 1 /2 in. Air motor chassis high pressure pump 50:1

Type Flexair Pneumatic Pressure Control Valves

DP DIAPHRAGM PUMP Parts & Instruction Manual

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Stub pump. Model 84933, 84934, series D. Installation and maintenance guide DANGER

HALLMARK INDUSTRIES INC

G8 Portable Fuel Transfer Pump Owner s Manual

OPERATIONS MANUAL LEVER CHAIN HOIST

TYPE S RELAY VALVE (Volume booster) Service Manual

Models P, P, P, , DANGER

40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover

Viscount I Hydraulic Motor and Displacement Pump

MULTIPOSITION AIR CYLINDER

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

ActuLink ABS Module - ABS-MOD-400

Universal Hand Pump. Instructions D EN. - For transferring grease to Grease Jockey and G3 Systems - Part No Hand Operated - 35# Pump

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

Pro Shot Grease Dispense Valve

Warning and Safety Precautions

Read this entire manual before operation begins.

Installation, Operation and Maintenance of the Airflex Model BT Rotorseal Assembly

SC HYDRAULIC ENGINEERING CORPORATION

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

ORIGINAL INSTRUCTIONS G715A. Pneumatic-hydraulic Riveter E. Warner Ave Santa Ana, CA

PACIFICA Shower Cabin Installation Instructions

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

Penguin Gentoo 600B Cordless Sprayer User s Manual

SUPERSPOOL II VALVE PNEUMATIC DIRECTIONAL CONTROL VALVE SERVICE INFORMATION

Specialists in Lubrication Products since 1912

Easytork Solenoid Valve IOM

INSTALLATION INSTRUCTIONS For Model 855 Wolo Express TM

POSITIVE DISPLACEMENT FLOWMETERS

POLISHER KIT Model 95030

FPS-500 / FPS 750. Fuel Polishing System. Installation and Operating Manual

151 Border Machine OPERATING INSTRUCTIONS MAINTENANCE INSTRUCTIONS ILLUSTRATED PARTS LIST

SC HYDRAULIC ENGINEERING CORPORATION

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Zip-Tex Spray Gun. Instructions A. Model psi (0.86 MPa, 8.6bar) Maximum Working Pressure

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

25 GALLON PORTABLE OIL LIFT

Operating Manual High Viscosity Dispense Valve Item #

50:1 Grease Pump Kits

Displacement Pump 3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A

RCV-V PNEUMATIC DIRECTIONAL CONTROL VALVE

Stub pump 3:1. User and maintenance instructions. Models and , series D. Date of issue December Form number

Displacement Pump Used in the Ultra Max 695 Sprayers 3000 psi (207 bar, 21 MPa) MAXIMUM WORKING PRESSURE

ATD-7391A 10-Ton Long Chassis Service Jack Owner s Manual

CRD610 Automatic Fitting Inserter

810201,810202,810203,810204

LABORATORY DISPERSERER

- C8. SINGLE AND MANIFOLD TYPE INJECTORS for dispensing fluid lubricants and greases not exceeding Lincoln ventmeter viscosity of 600 psi.

CRD600 Automatic Fitting Inserter

(KERNEL) SAND BLAST CABINET ( 220L ) ASSEMBLY & OPERATION INSTRUCTION

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P

Displacement Pump INSTRUCTIONS-PARTS LIST psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A. Model , Series A

HEAVY DUTY ONBOARD AIR SYSTEM

Read this entire manual before operation begins.

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

The Esteem Steel Self Propel Wheelchair Instructions

ABRASIVE BLAST CABINET

Designers and Manufacturers of Hydraulic and Pneumatic Equipment Since 1953 SC HYDRAULIC ENGINEERING CORPORATION

PARTS AND INSTALLATION MANUAL

INSTRUCTION GREASE PUMP. PD110A50T MODEL No PD110A50T-SL MODEL No PD110A50 MODEL No DR110A50 MODEL No.

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Pneumatic High-Viscosity Filtration System Instruction Manual

Automatic air grease gun

MDP 1000 OPERATING INSTRUCTIONS PUMP MDP 1000 OPERATING INSTRUCTIONS

L A N G E L I F T P R O D U C T M A N U A L PRODUCTS THAT LIFT THE WORLD! USAGE & MAINTENANCE GUIDE. a Division of Hevi-Haul International, Ltd.

Easytork Vane Actuator IOM

MODEL BARE REEL SERIES E

INSTRUCTIONS-PARTS LIST

INSTALLATION AND SERVICE MANUAL

ECONOMAIR SERIES CYLINDERS

Model No , -2, -3, -4, -5, , , -2, -3, -4, -5, and SL-V INJECTOR Series A

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

BC632 / BCL632 BC635 / BC635

Owner s Manual & Safety Instructions

Long Chassis Hydraulic Service Jacks

T1-Titanium Non-HVLP Spray Gun

TECHNICAL SERVICE MANUAL INSTALLATION, START UP, TROUBLESHOOTING, SERIES SG-04, SG-05 & SG-07 spur gear PUMPS

Benron Equipment & supply, Inc.

POWER GEAR SLIDE-OUT MANUAL

Transcription:

50:1 Value Line Pneumatic Grease Pump Technical Brief 07/01/2010 No. 18710 201 Fits 35 lb. Pail Premium quality pneumatic pump used for 35 lb. Pail 1.Recommended Usage Grease pumps with a ratio of 50:1 are the most common pumps used for the distribution of NLGI#2 Grease from a pail to the metered outlets. The pumps will service several dispensing outlets depending on the distance from pail to the material outlet. The large diameter air motor and pump stroke of this model provide a high delivery volume. WARNING: Do not use pumps for gasoline or highly flammable products! Do not use pumps for water based fluids, solvents or chemicals! 2. Specifications Model No. 18710 201 Dia. of air motor 3 Ratio 50:1 Suction Tube for length 18 Diameter of follower plate 1.26 Max air pressure 120 psi Operating pressure 90 psi Min air pressure 60 psi Max material pressure at 120 psi 6000 psi Air inlet 1/4 Female Material outlet 1/4 Female Max sound level at 3 ft 80 db Air consumption 9 CFM

Help System For Lubeq Corp. DATA SHEET 07/01/2010 3. Delivery Performance The delivery performance depends on the viscosity, temperature and distance. Friction loss may reduce the delivery performance. The delivery performance depends on the combination of the distance of the material line, flow meter and/or hose reel. The data shown below is approximate and might be reduced up to 30 % if used with a flow meter. Distance Free flow At 35 ft. At 100 ft At 150 ft 50:1 pumps 24 oz. 14 oz. 11 oz. 10 oz. 4. Technical Description The pump consists of parts machined from aluminum, brass, aluminum and carbon steel. The seals are made from polyurethane, Viton and NBR. The control module has very few moving parts and springs resulting in a very simple air motor operation. The double acting pump performs at a very low noise level, without vibration. The air motor parts are CAD precision machined. All seals and O-Rings are precision fitted. The piston is made from polished, treated steel. 5. Operating Requirements Pneumatic pumps require clean, moisture free air pressure! Best results are achieved if an Air Filter / Regulator / Lubricator, see our No. 20 216, is installed in front of the air inlet opening. To avoid damages we recommend a 90-psi air pressure setting. Warning: An increase in air pressure above 120 psi may result in damages to the pump and accessories. Your warranty is no longer valid. Filter/Regulator/Lubricator installation AIR IN AIR OUT Pump inlet

Help System For Lubeq Corp. DATA SHEET 07/01/2010 6. Maintenance Pneumatic pumps are sensitive to dirt and water in the air supply. Pumps fail is dirt gets into the suction valve. A. Too much moisture will cause ice build-up and slow down or eventually stop the pump. B. If pump is used without a recommended Filter/Regulator/Lubricator, frequently lubricate pump with special oil for pneumatic equipment. Squirt oil in air intake wipe off excess oil from muffler.. C. Drain water regularly from compressor air reservoir. D. When changing pumps from one pail to another, avoid picking up dirt through the suction valve. Do not set pump on floor covered with oil absorb products. Unless authorized by us do not take pumps apart! We will NOT honor a warranty if pumps have been disassembled. 7. Warranty LUBEQ Corporation warrants only to its customers, unless otherwise stated, that its products are free from defects in workmanship and/or materials for 12 months, or stated otherwise, from the date of sale by LUBEQ Corp. The warranty time is extended by 6 months to cover inventory of our distributors. In case of a claim we require documentation showing the date of sale by our distributors. In order to claim credit for an exchange our customer must get prior approval. We will not accept claims for products, if the product was disassembled or used for materials not suited for such products, due to abuse, misuse, improper use or lack of maintenance. Failure to follow operating instruction or stated operating requirements would void this warranty. This warranty does not cover failure of parts or components due to normal wear or damage or failures, which in the judgment of LUBEQ Corp. arise, from misuse, abrasion, corrosion, negligence, accidental damage, faulty installation or tampering. If the LUBEQ Corp. inspection discloses no defect in material or workmanship, repair and return will be made at customary charges. LUBEQ Corp. has made a diligent effort to accurately illustrate and describe its products. However such illustrations and descriptions are not a warranty. This warranty is in lieu of and excludes all other warranties, expressed or implied, including, without limitation, merchantability or fitness for a particular purpose. LUBEQ Corp. does not accept liability for consequential or incidental damages. The warranty only applies to the purchase price of the LUBEQ Corp. product. 1. Pneumatic Pumps - Warranty of 5 (five) years, see above warranty conditions. The warranty is void if pumps have been disassembled used for fluids other then stated in data sheets. Pumps are warrantied against defects in workmanship or materials under normal use, any pump which is determined defective in material and workmanship and returned to LUBEQ Corp., will be repaired or replaced at LUBEQ Corp. s option.

Help System For Lubeq Corp. DATA SHEET 07/01/2010 8. Trouble Shooting Most problems are dirt, water and ice! There is no grease coming out of control gun. New Installation 1. Check if hoses are connected correctly. 2. Check if air supply is hooked up. 3. New pumps come primed. If grease is not discharged from control gun: a. Release air in hose. b. Allow time to discharge possible air in material line. c. Disconnect hose and run pump without hose. 4. Check for dirt in the suction valve. If there is any type of oil absorption material on the ground where you set up the pump, you might have picked up dirt in the suction valve on the bottom of the pump. 2. Pump was used and is slow or stopped 3. Pump is working there is no grease pumped. Important 4. Pump accelerates, nothing is pumped 1. If pump is slow or stopped, does not work at all a. Check air supply b. Check for Ice or Dirt Pneumatic pumps work with air pressure. Working with compressed air, water is accumulated in the compressor tank and air supply lines. Water may cause icing in the air motor. 2. Let ice melt and try again. Drain water from the compressor tank. 3. Water in the pump is an indication of damage. Water will cause rusting of internal parts! You must have the pump serviced. To avoid the loss of warranty, do not take apart pump. a. See above No 1-5 under new installations. b. Check for dirt in suction valve Check material lines for air pockets Check for material shavings from installation in material line. Check function of control gun To avoid loss of the warranty, do not disassemble air motor or any part for the suction tube except for the suction valve Pump will accelerate if the pail or container is empty! 1. Disconnect pump from air supply immediately to avoid air pressure filling the supply lines. 2. You must bleed air before you continue to use pump.

DATA SHEET 07/01/2010

DATA SHEET 07/01/2010