CORE SERIES (EN) SERIES CORE (FR) CORE SERIE (DE) SERIE CORE (ES) SERIE CORE (IT)

Similar documents
Adam Equipment. CB Balance. (P.N Revision B1, Apr 2014)

DUNE DCT SERIES Manual

Adam Equipment. User Manual (EN) Pricing Retail RAV Series Adam Equipment Co. Ltd.

LHS/LHSa SERIES Manual

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Compact Scales. Software Revision V1.25 & above

Adam Equipment. TBB - TRIPLE BEAM Mechanical Balance Manual. 8141, RevD Nov2015 (ENG)

Adam Equipment. SHS/SHSa SERIES. Software version 2.3

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Adam Equipment CPW COMPACT SCALE

Set-Up Guide. Part # , Rev 1.0, Sep

Adam Equipment LHS SERIES. (P.N , Revision A March 2012)

Adam Equipment MIW-20 BABY SCALE. ADAM EQUIPMENT CO. LTD. p.n. 4295, Rev. B, March 2004

SHS/SHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version S1.1/SA1.1

NCSA 20plus Service Manual

LHS/LHSa SERIES. Adam Equipment. (P.N , Revision B November 2012) Software version L1.1/LA1.1

Adam Equipment GK / GBK / GFK SCALE. (P.N , Revision C2, July 2013)

WARRIOR SERIES USER MANUAL

PTS SERIES With AE402 Indicator

Ohaus ES Series Bench Scale

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

User Manual. PBA428 Weighing platform

Valor 2000 Series Instruction Manual

SPC Series. Digital Scale. Operation Manual

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

SAUTER TVO Version /2014 GB

GRAVITY MEASUREMENT, INC.

CITIZEN. series. Precision Balances

Catapult 1000 Series Instruction Manual

Virtual Measurements & Control. VC210 Operators Manual

Adam Equipment CBK SERIES

Adam Equipment AE 401 INDICATORS. (P.N. 9520, Revision B3, September 2008)

Operating Instructions School Balance

User Guide. Digital Shipping Scale S150

RoboSterz. Automatic Management of Steering Without Operator ITA. Mod. V.

Operation instructions Platform/floor scales

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

Navigator TM Series Balances Instruction Manual

Defender 3000 Series Base Instruction Manual

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

Operating manual FP-2. Index

SCALIX MULTIPURPOSE SCALES SCALIX COMPACT SCALE FKS-600 FKS-6000 INSTRUCTION MANUAL

Price Computing Scale D Series Operation Manual

1. Introduction Specifications Operation Guide Trouble shooting Note... 13

Quick Guide. brite Advanced Retail scale

SSP-Series Portable Balances Operation Manual

Ohaus EC Series Instruction Manual

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

Instructions for use L 2015

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

uline.com

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components

Scout TM Series Balances - SKX Instruction Manual

TriScroll TM 300 Series Dry Scroll Vacuum Pump

PLATINUM PCT101 PRECISION POCKET CARAT SCALE

(((temporary title page))) Please read these instructions before using your FS/GS HUSKY FS/GS USER LEAFLET

EDGE. User Manual. EDGE-5K (5000g x 1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.0


GENERAL INFORMATION AVOID PLACING THE SCALE IN LOCATIONS THAT MAY AFFECT ACCURACY:

Weighing Indicator TM701 Handrail scales

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

CONTENTS APM ELECTRONIC WEIGHING INDICATOR OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS 3. KEYBOARD LAYOUT AND DESCRIPTION 4.

This manual covers the following model:

User Manual Pocket Pro, Pro + ph

Press the buttons for fun sounds and music! fisher-price.com

CED PRO II. High Precision Electronic Scale Instructions

MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

X0056. fisher-price.com

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

ECONOMISER SERIES E2T USER MANUAL

Scout Series Balances - SPX Instruction Manual

Charder. Medical scale. User instruction. Important information. This user instruction must be read before the medical scale is used.

MODEL PS-4 DIGITAL PORTION SCALE

ECOWEIGH Series ECO-5K. User Manual. ECO-5K (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Y9854. fisher-price.com

ELECTRICAL. Laser Distance Measure User Guide

PRO-SET CC800A Series Programmable Charging Scale CERTIFIED

PLATINUM. PREMIUM CLASS pocket scale. Manual & Operation Guide

Weighing Scale IDS-802. User Manual

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

PORT-A-WEIGH CRANE SCALES

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

OVERVIEW OF CONTROLS


User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

American Weigh Scales LS-110. User Manual. LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.

Ohaus Corporation,19A Chapin Road, PO Box 2033, Pine Brook, NJ USA

MS-4200/4201/4202/4202L USER MANUAL

V9961 V9961

CONTENTS OPERATION MANUAL BENCH/FLOOR SCALE 1 INSTALLATION 2 SPECIFICATIONS

IMC. Battery Charger. Instruction Manual

Balanzas de la gama Scout TM SJX Series Manual de Instrucciones

Instruction Manual. Vibration Calibrator VC20. Manfred Weber. Metra Mess- und Frequenztechnik in Radebeul e.k. Meissner Str D Radebeul

W9740. fisher-price.com. 2 Ride. 1 Sit. 3 Walk

Transcription:

Adam Equipment CORE SERIES (EN) SERIES CORE (FR) CORE SERIE (DE) SERIE CORE (ES) SERIE CORE (IT) (P.N. 308669539, Revision B5, Mar2016) Adam Equipment 2016

GLISH: P1-17 FRANÇAIS: P18-37 DEUTSCH: P38-58 ESPAÑOL: P59-74 ITALIANO: P75-92 EU DECLARATION: P93 Adam Equipment 2016

Easy Reference: Model name of the balance: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase: Name of the supplier and place: Adam Equipment 2016 1 308669539revB5-Mar16

CONTENTS 1.0 CONTENTS... 2 2.0 SET UP... 3 2.1 UNPACKING AND SETTING UP YOUR BALANCE... 3 2.2 INSTALLING BATTERIES... 4 2.3 OVERVIEW - DISPLAY / KEY BOARD... 4 2.4 LOCATING AND PROTECTING YOUR BALANCE... 6 2.5 STORING WHEN NOT IN USE... 7 3.0 BASIC OPERATION... 8 3.1 TURNING ON THE BALANCE... 8 3.2 ZEROING / TARE... 8 3.3 WEIGHING... 9 3.4 WEIGHING UNITS... 9 4.0 PARAMETERS... 10 4.1 AUTO POWER OFF... 10 4.2 SETTING THE BACKLIGHT... 11 4.3 ENABLING THE WEIGHING UNITS... 11 5.0 CALIBRATION... 13 6.0 TROUBLE SHOOTING... 14 6.1 ERROR MESSAGES... 14 6.2 REPLACEMENT PARTS AND ACCESSORIES... 15 7.0 SPECIFICATIONS... 16 8.0 WARRANTY STATEMENT... 17 Adam Equipment 2016 2 308669539revB5-Mar16

2.0 SET UP 2.1 UNPACKING AND SETTING UP YOUR BALANCE 1) Remove the shipping protection screw and round cover as shown below using the Allen key supplied in the plastic bag. (It is advisable to keep the shipping protection screw and the round cover along with the packing box for using during shipping to another location in future). Shipping protection screw Round cover around the screw 2) Place the pan (which comes separately packed) in the receptacles on the top cover. Gently place the plastic pan support into the receptacle and secure with the screw supplied in the plastic bag. Be careful when putting the screw in that you do not use too much force as it can damaged the loadcell. You should just be able to use light force to secure the screw. 3) Place the stainless steel pan on top of the plastic pan. 4) Place the balance on a firm and flat surface for accurate weighing. Adam Equipment 2016 3 308669539revB5-Mar16

2.2 INSTALLING BATTERIES Remove the battery compartment cover and insert six batteries (R6P/LR6 /AA size) into the battery compartment. 2.3 OVERVIEW - DISPLAY / KEY BOARD BEHIND DC adapter socket Lock down slot TOP Stainless Steel pan Plastic Pan LCD display [On/Off] key Turns the balance power on/off [Unit] key Changes weighing units. Also used when calibrating [Tare] key Sets display to zero or tares the balance Adam Equipment 2016 4 308669539revB5-Mar16

BOTTOM Battery compartment screws Battery compartment cover Batteries are not included DISPLAY battery indicator ZERO indicator Indicates when the balance zero is correct. STABLE indicator Indicates when the reading is stable. Adam Equipment 2016 5 308669539revB5-Mar16

2.4 LOCATING AND PROTECTING YOUR BALANCE In order to keep your balance functioning at its best we suggest that you do the following: Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents. Make sure the balance is located on a strong table and free from vibration. Avoid unstable power sources. Do not operate near large users of electricity such as welding equipment or large motors. Do not leave batteries in the balance if you are not using it for a long time. Keep free from vibration. Do not place near heavy or vibrating machinery. Avoid high humidity that might cause condensation, and keep away from direct contact with water. Do not place near open windows, air-conditioning vents or fans that may cause a draft and unstable readings. Keep the balances clean, and do not stack material on the balance when it is not in use. The Core has a stacking feature allowing more than one unit to be stacked on top of each other. For more details on this see the section on storing. Adam Equipment 2016 6 308669539revB5-Mar16

2.5 STORING WHEN NOT IN USE If you have any of the Highland TM series or Core Balance TM lines you can store them easily on top of each other. This helps to save space and protect them from damage. Without Shield With Shield Note: Only 4.7 / 120mm ø pan size models can be stacked for storage. Core models with 5.7 / 145mm ø may be stacked at the top of the pile but machines cannot be stacked on top of them due to the larger pan size. Adam Equipment 2016 7 308669539revB5-Mar16

3.0 BASIC OPERATION 3.1 TURNING ON THE BALANCE Plug in the unit using the DC adapter or power from the batteries. 1) Press the On/Off button and the balance will automatically show Cqt-1.0 Cqt then count from 0 to 9 for a few seconds, and show the voltage X.X Vol where x.x is the voltage of the battery or the DC adapter. Finally it will display "0.00" along with the last selected weighing unit, Stable symbol, and Zero symbol. 2) The balance is ready to be used. 3) To turn the balance off after use press the [on/off] key again. There is an auto power-off function that will automatically turn the unit off, this can be set in the parameters section. 3.2 ZEROING / TARE You can press the [Tare] key to set a new zero point. Zero will be set if the reading on the balance is less than 3% of the balances capacity. This may be necessary if the weight is not reading zero with nothing on the pan. The zero indicator will show up in the top left corner of the LCD. If you are using a container to weigh then you can place this on the platform and press the [Tare] key, providing the container weight is more than 3% of the maximum capacity of the balance, the display will show zero and NET will light up on the display. You can then weigh your object in the container. Tared weight is subtracted from the total balance s capacity. Note: When the container is removed a negative value will be shown. If the balance was tared just before removing the container, this value is the gross weight of the container plus all items inside the container which were removed. Adam Equipment 2016 8 308669539revB5-Mar16

3.3 WEIGHING To determine the weight of a sample, first tare an empty container (if used), then place the sample in the container. The display will show the weight and the unit of weight currently in use. The stable indicator will light up when the reading is stable. 3.4 WEIGHING UNITS To change the weighing units, press [Unit] to cycle through the available units. See the Parameter section to enable or disable the weighing units. Once the unit has been selected, the weight will be displayed in the selected unit and a symbol for the weight will be shown. Adam Equipment 2016 9 308669539revB5-Mar16

4.0 PARAMETERS The balance has 3 parameters that can be set by the user. FUNCTION SECTION DESCRIPTION Auto Off See section 5.1 Sets the auto power off function Backlight See section 5.2 Sets the backlight OFF BL backlight is off Weighing unit See section 5.3 1 BL backlight is automatic 2 BL backlight is always on Sets the units to be used kg g lb oz ct dr GN N-tl.t 4.1 AUTO POWER OFF The auto power off function helps conserve power when using the batteries or DC adapter. The Auto switch-off time may be set up by the user and is the time after a period of inactivity i.e. no weight movement or key presses. 1) To set this parameter turn the power off, press and hold the [Tare] key then press the [on/off] key once, then release the [Tare] key. 2) The display will show the first function XX PWR, where XX is the last setting. 3) Press [Tare] to select the settings as follows: Off PWR Auto power off 10 PWR 10 seconds before the power will switch off 20 PWR 20 seconds before the power will switch off 30 PWR 30 seconds before the power will switch off 40 PWR 40 seconds before the power will switch off 50 PWR 50 seconds before the power will switch off 60 PWR 60 seconds before the power will switch off 70 PWR 70 seconds before the power will switch off 80 PWR 80 seconds before the power will switch off 90 PWR 90 seconds before the power will switch off 4) Press the [Unit] key to confirm the setting 5) To exit turn the balance off and back on again Adam Equipment 2016 10 308669539revB5-Mar16

4.2 SETTING THE BACKLIGHT The backlight may be enabled or disabled by the user. If the backlight is disabled, the battery life will be greater. The following settings are available: 1 BL Sets the backlight to operate automatically when a weight is placed on the balance or a key is pressed. 2 BL Sets the backlight to be on all the time. OFF BL Sets the backlight to be off. 1) To set this parameter turn the power off, press and hold the [Tare] key then press the [on/off] key once, then release the [Tare] key. 2) The display will show the first function PWR 3) Press the [Unit] key until the display shows XX BL where XX is the last setting 4) Press [Tare] key to select the settings as follows 1 BL - 2 BL OFF BL 5) Press the [Unit] key to confirm the setting 6) To exit turn the balance off and back on again 4.3 ENABLING THE WEIGHING UNITS You can enable and disable the weighing units available to the user when they press the [Unit] key as described in section 4.4 Weighing Units. 1) To set this parameter turn the power off, press and hold the [Tare] key then press the [on/off] key once, then release the [Tare] key. 2) The display will show the first function PWR 3) Press the [Unit] key until the display shows you XX g where XX is the last setting on or off. 4) Press the [Tare] key to select on or off. 5) Press the [Unit] key to move to the next weighing unit. 6) Repeat steps 5 and 6 until you have set all of the weighing units. Adam Equipment 2016 11 308669539revB5-Mar16

7) To exit turn the balance off and back on again The following table shows the different weighing units which are available to the user and the conversion factors for each. Name of the Units Description Conversion Factor Display Symbol Kilograms A standard metric unit 0.001 Kg Grams A standard metric unit 1.0 G Pounds Standard weighing unit in UK/USA. 0.002205 Lb Ounce Avoirdupois ounce. 16 ounces make a pound. 0.03528 OZ Carat Used for weighing jewelry and gems, 5.0 ct etc. Dram Avoirdupois unit there are 16 DR in an 0.564383 DR ounce. Grains A basic weighing unit in the imperial 15.432 GN system. Used to weigh gun powder. Newtons Used to measure force 0.009808 N Taiwanese taels Used to weigh coral, pearls etc. 0.026666 Tl.t Adam Equipment 2016 12 308669539revB5-Mar16

5.0 CALIBRATION Calibration may be required when the balance is initially installed or moved to a new location. Over time and use, mechanical deviations may occur so it is recommended that you calibrate you balance regularly for peak performance. Before calibrating your should make sure you have the correct weights. The weights should be known to an accuracy that is appropriate for the balance being calibrated, for example, OIML Class M1 type or ASTM E617 Class 4. If you do not have the correct weights do not attempt calibration. Model CQT 202 CQT 251 CQT 601 CQT 1501 CQT 2601 CQT 2000 CQT 5000 Calibration Weight 100g Or 200g 100g Or 200g 200g Or 400g Or 600g 500g Or 1000g Or 1500g 1000g Or 2000g 1000g Or 2000g 1000g Or 3000g or 5000g 1) To calibrate the balance apply power and switch the balance on, whilst the display is cycling through it s test routine press the [Tare] and [Unit] keys at the same time, then release after 1 second. 2) The display will show UnLOAD remove any objects from the pan. 3) Press the [Tare] key to enter a zero value. 4) The value last used for calibration will be displayed (see above table). To select a different calibration weight, press the [Unit] key. 5) Once you have selected the calibration weight to be used press the [Tare] key. 6) LOAD will be displayed, place the calibration weight on the pan. 7) Once the stable sign is shown press the [Tare] key. 8) If the weight is within 5% of the last calibration value the display will show PASS and exit the calibration mode. If the calibration is not successful the display will show FAIL and exit the calibration mode, if the calibration fails try it again. Adam Equipment 2016 13 308669539revB5-Mar16

6.0 TROUBLE SHOOTING 6.1 ERROR MESSAGES If an error message is shown, repeat the step that caused the message. If the error message is still shown then contact your dealer for support. ERROR CODE DESCRIPTION POSSIBLE CAUSES Solutions ADO A/D Value too high. ADL A/D Value too low. ----- A/D count is not correct when turning the balance on. Weight on the pan when turning on. Improper calibration of the balance. Damaged load cell. Damaged Electronics. Pan is not installed when turning on. Calibration not correct. Damaged load cell. Load cell damaged. Electronics damaged. Unit-E Unit error. Low battery indicator. Batteries may be flat. FAIL Calibration failure. Unstable machine cannot get a stable reading. No Power when turning on. Incorrect mass used to calibrate. The user calibration is not within 5% of factory calibration. Possible damaged to loadcell. Remove any weight from the stainless steel pan. Recalibrate. Install pan and power back on. Recalibrate. Remove any weight from the stainless steel pan and try rebooting. Try calibrating the balance. Charge the battery. Try to recalibrate, check that the weight used to calibrate matches that of the value of the balance. Possible damage to the Loadcell. Make sure the balance is on a flat surface and away from vibration. Battery may be flat. DC adapter may not be working. Change the batteries. Or use the DC adapter Adam Equipment 2016 14 308669539revB5-Mar16

6.2 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories, contact your supplier or Adam Equipment. A partial list of the more common items follows: Part Number Description 7.00.4.0.0023 POWER SUPPLY STANDARD MODEL 12VDC 500mA - UK 7.00.4.0.0024 POWER SUPPLY STANDARD MODEL 12VDC 500mA - USA 7.00.4.0.0025 POWER SUPPLY STANDARD MODEL 12VDC 500mA - OZ 7.00.4.0.0026 POWER SUPPLY STANDARD MODEL 12VDC 500mA - EURO 7.00.4.0.0027 POWER SUPPLY STANDARD MODEL 12VDC 800mAa - SA 3.08.1.2.2009 TOP PAN 120mm 3.08.1.2.2011 TOP PAN 145mm 3.08.2.3.2031 BREEZE SHIELD WITH LID 3.08.2.3.2033 IN USE COVER 7.00.1.0.0046 SECURITY LOCK AND CABLE Adam Equipment 2016 15 308669539revB5-Mar16

7.0 SPECIFICATIONS Model # CQT-202 CQT- 251 CQT-601 CQT-1501 CQT-2601 CQT-2000 CQT-5000 Maximum Capacity 200g 250g 600g 1500g 2600g 2000g 5000g Readability 0.01g 0.1g 0.1g 0.1g 0.1g 1g 1g Resolution 1:20000 1:2500 1:6000 1:15000 1:26000 1:2000 1:5000 Repeatability (Std Dev) 0.02g 0.1g 0.1g 0.2g 0.2g 1g 1g Linearity ± 0.02g 0.1g 0.1g 0.2g 0.2g 1g 1g Units of Measure kg / g / lb / oz / ct / dr / GN / N/tl.t Stabilisation Time 3 seconds 2 seconds 3 seconds 2 seconds Operating Temperature Power Supply 0ºC to 40ºC 32ºF to 104ºF 12VDC adapter (800mA South Africa, 500mA rest of world), or 6x AA batteries Calibration Push button calibration using external mass Calibration Mass 200g 250g 600g 1500g 2000g 2000g 5000g Display Draft shield (diameter x h) Balance Housing 132mm ø x 82mm (5.2 ø x 3.2 ) 6 digit LCD, 18mm digits, with backlight ABS Plastic Pan Size 120mm ø (4.7 ø) 145mm ø (5.7 ø) Overall Dimensions (w x d x h) Net Weight 173 x 255 x 86mm (6.8 x 10 x 3.4 ) Without draft shield 820g (1.8lb) N/A Adam Equipment 2016 16 308669539revB5-Mar16

8.0 WARRANTY STATEMENT Adam Equipment offers Limited Warranty (Parts and Labour) for any components that fail due to defects in materials or workmanship. Warranty starts from the date of delivery. During the warranty period, should any repairs be necessary, the purchaser must inform its supplier or Adam Equipment Company. The company or its authorised Technician reserves the right to repair or replace the components at any of its workshops at no additional cost, depending on the severity of the problems. However, any freight involved in sending the faulty units or parts to the Service Centre should be borne by the purchaser. The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed. All claims are at the sole discretion of Adam Equipment. This warranty does not cover equipment where defects or poor performance is due to misuse, accidental damage, exposure to radioactive or corrosive materials, negligence, faulty installation, unauthorised modifications or attempted repair, or failure to observe the requirements and recommendations as given in this User Manual. This product may include a rechargeable battery that is designed to be removed and replaced by the user. Adam Equipment warrants that it will provide a replacement battery if the battery manifests a defect in materials or workmanship during the initial period of use of the product in which the battery is installed. As with all batteries, the maximum capacity of any battery included in the product will decrease with time or use, and battery cycle life will vary depending on product model, configuration, features, use, and power management settings. A decrease in maximum battery capacity or battery cycle life is not a defect in materials or workmanship, and is not covered by this Limited Warranty. Repairs carried out under the warranty do not extend the warranty period. Components removed during warranty repairs become company property. The statutory rights of the purchaser are not affected by this warranty. The terms of this warranty is governed by the UK law. For complete details on Warranty Information, see the terms and conditions of sale available on our web-site. Adam Equipment 2016 17 308669539revB5-Mar16

EU Declaration of Conformity / Déclaration de conformité / Konformitätserklärung Declaración de Conformidad / Dichiarazione di conformità Year CE marking was first affixed to declared product CORE CQT DIGITAL ELECTRONIC WEIGHING BALANCE SERIES 16 Adam Equipment Co. Ltd. Maidstone Road, Kingston Tel: +44 (0) 1908 274545 Milton Keynes, MK10 0BD Fax: +44 (0) 1908 641339 United Kingdom Email: sales@adamequipment.co.uk www.adamequipment.com We declare under our sole responsibility that the balance models listed below marked with CE are in conformity with the directives and standards mentioned. Nous déclarons sous notre seule responsabilité, que les types de balance cités ci-dessous munis de la mention "CE" sont conformes aux directives et aux normes mentionnées ci-après. Wir erklären in alleiniger Verantwortung, dass die untenstehenden Waagentypen gekennzeichnet mit "CE" mit den genannten Richtlinien und Normen übereinstimmen. Nosotros declaramos bajo responsabilidad exclusiva que los modelos de balanzas indicados a continuación con el distintivo "CE" son conformes con las directivas y normas citadas. Noi dichiariamo sotto nostra unica responsabilità che i tipi di bilance specificati di seguito contrassegnati con la marcatura CE sono conformi alle direttive e norme citate. Adam Equipment Model CQTxxxx balances. 2014/30/EU EN61326-1:2013 Part 1 2014/35/EU EN61010-1:2010 Part 1: 2011/65/EC, RoHS 2 EN50581: 2012, Signed for and on behalf of: Adam Equipment Company Ltd. United Kingdom, 20 Feb 2016 Clive Jones, Quality & Product Manager. Adam Equipment 2016 93 308669539revB5-Mar16

WEEE 2012/19/EU This device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements. Disposal of batteries (if fitted) must conform to local laws and restrictions. Cet appareil ne peut être éliminé avec les déchets ménagers. L élimination de la batterie doit être effectuée conformément aux lois et restrictions locales. Dieses Gerät nicht mit dem Hausmüll entsorgt. Dispositivo no puede ser desechado junto con los residuos domésticos Dispositivo non può essere smaltito nei rifiuti domestici. FCC / IC CLASS A DIGITAL DEVICE EMC VERIFICATION STATEMENT NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules and Canadian ICES-003/NMB-003 regulation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Adam Equipment products have been tested with, and are always supplied with mains power adaptors which meet all legal requirements for the intended country or region of operation, including electrical safety, interference and energy efficiency. As we often update adaptor products to meet changing legislation it is not possible to refer to the exact model in this manual. Please contact us if you need specifications or safety information for your particular item. Do not attempt to connect or use an adaptor not supplied by us. Adam Equipment 2016 94 308669539revB5-Mar16

ADAM EQUIPMENT is an ISO 9001:2008 certified global company with more than 40 years experience in the production and sale of electronic weighing equipment. Adam products are predominantly designed for the Laboratory, Educational, Medical, retail and Industrial Segments. The product range can be described as follows: -Analytical and Precision Balances -Compact and Portable Balances -High Capacity Balances -Moisture analysers / balances -Mechanical Scales -Counting Scales -Digital Weighing/Check-weighing Scales -High performance Platform Scales -Crane scales -Medical Scales -Retail Scales for Price computing For a complete listing of all Adam products visit our website at www.adamequipment.com Adam Equipment Co. Ltd. Maidstone Road, Kingston Milton Keynes MK10 0BD UK Phone:+44 (0)1908 274545 Fax: +44 (0)1908 641339 e-mail: sales@adamequipment.co.uk Adam Equipment Inc. 1, Fox Hollow Rd. 06478 USA Phone: +1 203 790 4774 Fax: +1 203 792 3406 e-mail: sales@adamequipment.com AE Adam GmbH. Instenkamp 4 D-24242 Felde Germany Phone +49 (0)4340 40300 0 Fax: +49 (0)4340 40300 20 e-mail: sales@adamequipment.co.za Adam Equipment S.A. (Pty) Ltd. 7 Megawatt Road, Spartan EXT 22 Kempton Park, Johannesburg, Republic of South Africa Phone +27 (0)11 974 9745 Fax: +27 (0)11 392 2587 e-mail: sales@adamequipment.co.za Adam Equipment (S.E. ASIA) PTY Ltd 2/71 Tacoma Circuit CANNING VALE 6155 Perth Western Australia Phone: +61 (0) 8 6461 6236 Fax +61 (0) 8 9456 4462 E-mail: sales@adamequipment.com.au Adam Equipment (Wuhan) Co. Ltd. A Building East Jianhua Private Industrial Park Zhuanyang Avenue Wuhan Economic & Technological Development Zone 430056 Wuhan P.R.China Phone: + 86 (27) 59420391 Fax + 86 (27) 59420388 E-mail: info@adamequipment.com.cn Copyright by Adam Equipment Co. Ltd. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment. Adam Equipment reserves the right to make changes to the technology, features, specifications and design of the equipment without notice. All information contained within this publication is to the best of our knowledge timely, complete and accurate when issued. However, we are not responsible for misinterpretations which may result from the reading of this material. The latest version of this publication can be found on our Website. www.adamequipment.com Adam Equipment 2016