Hydro-Flow Model 2300 Installation and Operation Guide B

Similar documents
Hydro-Flow Model 2200 Installation and Operation Guide B

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

Hydro-Flow Model 3100

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

F-2600 SERIES INLINE VORTEX FLOW METER

SIGNET 7002 Vortex Flow Sensor ENGLISH

Signet 7000/7001 Vortex Flow Sensors * *

Vortex Eggs Delta Flowmeter

Transmitting Transducer. Gas/Air Velocity Range:

Hot Tap Insertion Vortex

SIGNET Vortex Flow Sensors ENGLISH

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

VLM20 In-line Vortex Flowmeter

Armstrong In-Line and Insertion Vortex Flow Meters

Low Profile Insertion Vortex

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Vortex Plate. Model VP General Specification. Product Features

Model 1000 Vortex Meter

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER

Model FVP General Specification. Flanged Vortex Plate. Product Features

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2500 SERIES VORTEX METER

MODEL 106F TEFLON LIQUID FLOW SENSOR

Multivariable Vortex Flow Meter

Chapter Page. 1 Introduction Description 1

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

UniMag DT Series Electromagnetic Flow Tubes

Multivariable Vortex Flow Meter

Vortex In Line Flow Meter

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

VIM20 Vortex Insertion Flowmeter

Installation Fittings

Flow Measurement & Control Solutions

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Vortex In Line Flow Meter

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

VORTEX IN-LINE FLOW METERS

VIM20 Vortex Insertion Flowmeter

UTM10 Series Ultrasonic Transit-time Flowmeters

Appendix. Clearance. Skewed profiles. Application Schematics

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Liquid Turbine Flow Meter OwnerÊs Manual

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Signet 2536 Rotor-X Paddlewheel Flow Sensors

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

VIM20 Vortex Insertion Flowmeter

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

Electromagnetic Flow Monitor magphant

Model DFX Doppler ultrasonic flow meter

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

ISTEC MAGNETIC METERS

Ultra Compact UHP Liquid Flow Controllers

Model 5000 Vortex Meter

2100 Turbine Flow Sensor

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17

Vortex Flow Meter Model DVH

TABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications

Inline Ultrasonic Flowmeter

Fundamental Training. Flow Con t

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

+GF+ SIGNET Conductivity Transmitter. Instruction Manual GEORGE FISCHER +GF+

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

RIM20 Rotor Insertion Flowmeter

The readings you need, right where you need them. AX Series Vortex Meters

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

NT Flowmeter, Model 4401

Octave Water Meter Installation Manual

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

SIGNET 2750 ph/orp Sensor ENGLISH

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

DIGIFLO ELECTRONIC FLOWMETER

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

* * Rev M 10/14 Operating Instructions

* * Rev /18 Operating Instructions

Signet 515 Rotor-X Paddlewheel Flow Sensors

F-1500 SERIES INSERTION TURBINE FLOW METER

digital flow meters BW Digi-Meter F-1000

imag 4700 SERIES FLANGED MAGMETER

Flow-Alert Flow Switches (Micro Switch)

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Series 8000 Vortex Flow Meter

RCM - Direct Reading Flowmeters

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

SECTION MISCELLANEOUS VALVES

TURBINE METERS - WP Series

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Transcription:

Hydro-Flow Model 2300 Installation and Operation Guide 5700508-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Electrical Connections.. 7 Mechanical and Electrical Specifications 9 AE Global Support.. 10 Handling Your Flow Meter Even though the flow meter is one of the most rugged in the industry, exercise reasonable care with the flow meter. Understanding Vortex Flow Meters Vortex shedding flow meters measure flow by detecting the frequency at which vortices are alternately shed from a bluff body. The vortices create low and high pressure zones behind the bluff body which are detected as a force acting on the sensor wing. This force is transmitted through the sensor wing to the Hydro-Flow piezo-resistive sensor mounted inside the flow line. Hydro-Flow's unique and proprietary microprocessor-based piezo-resistive sensor can accurately and reliably process vortex signals 25 times smaller than permitted by other technologies. According to physical laws, the shedding frequency is directly proportional to the average flow velocity. This effect can be observed in the fluttering of a flag. When not installed, store the flow meter with the installation manual in its shipping container. Do not ram or poke objects into the meter bore or onto the sensor wing/shedder. Hydro-Flow is a no moving parts flow meter. If you push hard enough to see a part move, the flow meter is probably damaged. Pay particular attention to the direction of flow. The flow must impact the surface of the stainless steel shedder. The direction of the flow is clearly indicated on the flow meter electronics. The flow meter will not work if you install it backwards. The flow meter's installation location is important for optimum performance accuracy; a quick review of Installing Your Flow Meter on page 3 will be helpful. Identifying Your Flow Meter An identification plate (ID) is attached to your flow meter. For model code information, see Hydro-Flow Model and Suffix Codes on page 2. 2300-xx-x-x-x-x Vortex flow meters are preferred for many applications requiring wide flow range, accuracy, and reliability (no moving parts). Figure 1. Flow meter identification (ID) plate This document and the information contained herein is the proprietary property of Advanced Energy Industries, Inc. Copyright 2003 Advanced Energy Industries, Inc. All Rights Reserved.

Advanced Energy Hydro-Flow Model and Suffix Codes Table 1. Hydro-Flow model and suffix code identification table Category Description Suffix Codes Type Fixed insertion - PVDF 2300 Line size Mounting supplied by EMCO OR Retrofit to +GF+Signet fitting and no EMCO mountings required Output/ display Measuring units 0.5" (15 mm) 0.75" (20 mm) 1" (25 mm) 1.25" (30 mm) 1.5" (40 mm) 2" (50 mm) 2.5" (65 mm) 3" (80 mm) 4" (100 mm) 5" (125 mm) 6" (150 mm) 8" (200 mm) EMCO CPVC (0.5" to 1.5" line sizes only) EMCO PVC (0.5" to 1.5" line sizes only) EMCO PVDF EMCO Polypropylene Retrofit to +GF+Signet CPVC fitting Retrofit to +GF+Signet PVC fitting Retrofit to +GF+Signet PVDF fitting Retrofit to +GF+Signet polypropylene fitting Pulse/ no display 4 ma to 20 ma/ rate and total display Pulse rate and total display 4 ma to 20 ma/ no display for use with solar power supply (low power consumption 2 ma) English Metric 05 07 10 12 15 20 25 30 40 50 60 80 02 03 04 05 2R 3R 4R 5R 1 2 3 4 5 1 2 Example (2300-12-04-2-1): A 1.25" PVDF insertion flow meter with a PVDF union tee fitting and 4 ma to 20 ma analog output with a rate/total display with English measuring units. Retrofit example (2300-40-4R-2-1): A 4" PVDF fixed insertion vortex flow meter to be retrofit to existing PVDF fitting (Signet p/n SFMT040 wafer) with current, 4 ma to 20 ma output with a rate/total display with English measuring units. 2300 12 04 2 1 2300 40 4R 2 1 Ordering Considerations When ordering, please specify pipe size, material, and schedule (or outside and inside diameter of pipe). Standard English measuring units are gallons per minute (gpm) and gallons. Standard metric measuring units are cubic meters per hour (m 3 /hr) and cubic meters (m 3 ). Other units of measurement, such as acres, cubic feet, barrels, and liters are available and can be set by the factory. Please specify this requirement when the flow meter is ordered. Page 2 Hydro-Flow Model and Suffix Codes 5700508-B

Hydro-Flow Model 2300 Insertion Vortex Flow Meter For Signet retrofits, specify existing Signet fitting part number. Model 2300 retrofit is not compatible with Signet 0.5", 0.75", and 1.0" PVC and CPVC tee fittings. In this case, order EMCO fittings. Installing Your Flow Meter Upon receiving your Hydro-Flow equipment, verify that all materials on the packing list are present. Check for possible shipping damage and notify the freight carrier or your Hydro-Flow representative if there is any damage. Before installing your flow meter, verify that the model is consistent with your requirements. See Hydro-Flow Model and Suffix Codes on page 2 for identification information. Selecting the Best Flow Meter Location For optimum performance, you must consider straight run requirements and flow meter installation location relative to flow direction. Figure 2 illustrates possible flow meter locations. The good flow meter locations are recommended to ensure that the pipe and the flow meter will always be filled with fluid. Note: Consult the factory if you have special requirements. Straight Run Requirements The straight run of the pipe must have the same nominal diameter (D) as the flow meter body. Figure 2 illustrates the minimum requirements for straight run piping. Figure 2. Flow meter location illustrations and straight run requirements Page 3 Installing Your Flow Meter 5700508-B

Advanced Energy Mechanical Illustrations Dimensions in inches (and mm) Figure 3. Model 2300 mechanical drawing and condulet (with display) dimensions Wafer Fitting (PVDF or Polypropylene) Meter Size Inches (mm) 2" (50) 2.5" (62) 3" (80) 4" (100) 5" (125) 6" (150) 8" (200) Union Tee Fitting H 1.3 (40) W 2.45 (62) 2.7 (80) 1.82 (46) 5.3 (160) 1.94 (50) 7.0 (210) 2.20 (56) 11.7 (350) 2.50 (64) 14.11 (358) 2.75 (70) 16.20 (412) 2.8 (72) Note: CPVC and PVC wafer fittings are available only in 0.5" to 1.5" line sizes. Meter Size Inches (mm) 0.5" (15) 0.75" (20) 1" (25) 1.25" (30) 1.5" (40) L 5.05 (128) 5.59 (142) 6.14 (156) 6.33 (161) 6.93 (156) H 3.43 (87) 3.57 (91) 4.17 (106) 4.35 (111) 6.26 (159) Tee Fitting Meter Size Inches (mm) 0.5" (15) 0.75" (20) 1" (25) 1.25" (30) 1.5" (40) H 3.73 (95) 3.93 (100) 4.30 (109) 4.35 (111) 4.90 (124) W 3.81 (97) 4.06 (103) 4.17 (106) 4.38 (111) 4.60 (117) Page 4 Mechanical Illustrations 5700508-B

Hydro-Flow Model 2300 Insertion Vortex Flow Meter Wafer Mount Installation Tee Fitting Installation Wafer mountings are available in line sizes 2.0" to 8.0" in either PVDF or polypropylene (CPVC and PVC wafer mountings are available in line sizes 0.5" to 1.5"). For a wafer mount installation, flanges with self-centering gaskets are recommended for optimum performance. Gaskets should not protrude into the flow stream. Pipe supports are recommended if mechanical vibration is present. Pipe supports should follow industry standard piping practices. Align the bolt holes of each set of mating flanges. The bolt holes should be directly opposite each other in order to minimize any stress on the flow meter body. Snug all bolts prior to final tightening. Tighten bolts in a staggered fashion to avoid tilt (see Figure 4). Figure 4. Flange alignment (wafer installation) Install the flow meter with the flow arrow indicator on the electronics enclosure pointing in the direction of flow (see Figure 5). Hand tighten the red NPSM clockwise. Pipe Bad Flange Wafer Good Electronics assembly Align this edge of the electronics assembly parallel to pipe (as shown) Figure 5. Flow direction and condulet alignment Figure 6. Tee fitting installation Equipment You need an appropriate cement, primer, and cutting and deburring tool daubers with a minimum surface of onehalf the pipe diameter. In addition, you need natural fiber rags and gloves that are resistant to the cement and primer. Installation 1. Inspect pipe for a square, deburred cut and a 10 to 15 beveled end. With a dry, clean rag, remove all foreign matter from the pipe and tee surface. 2. Thoroughly coat the inside socket of the fitting with an appropriate primer by repeated strokes with a well-wetted applicator. 3. Coat the outer surface area of the pipe in a similar manner. 4. Apply a second application of primer to the inside socket of the tee fitting, then immediately apply a generous amount of cement to the outside of pipe. 5. Carefully apply cement to the inside of the tee fitting. Avoid excess cement in the fitting, which could puddle and partially block flow. Cement applications to both pipe and fitting should be made while the primer is still wet. 6. Immediately apply a second application of cement to the outside of pipe. Place the pipe into the flow meter bottom first while the cement on both the pipe and fitting are still liquid. Rotate the pipe 90, if possible. Hold for approximately 30 seconds. 7. Wipe any excess cement from the pipe and observe the set time specified by the cement manufacturer. 8. Install the flow meter with the flow arrow indicator on the electronics enclosure pointing in the direction of flow (see Figure 5). Hand tighten the red NPSM clockwise. Page 5 Wafer Mount Installation 5700508-B

Advanced Energy Union Tee Fitting Installation (PVDF and Polypropylene, Sizes 0.5" to 1.5") For PVDF and polypropylene fittings, heat fusing may be the preferred method over cement for installation. Install PVDF and polypropylene fittings according to your instrumentation guidelines. When the union tee fitting is installed, install the flow meter with the flow arrow indicator on the electronics enclosure pointing in the direction of flow (see Figure 5 on page 5). Hand tighten the red NPSM clockwise. Retrofit Installation Hydro-Flow model 2300 can be retrofit into most existing +GF+ Signet fitting sizes 0.5" and larger. The Model 2300 cannot be retrofit into +GF+ Signet fittings sizes 0.5", 0.75" and 1" PVC and CPVC tee fittings. In this case, use EMCO's own PVC and CPVC fittings. Install the flow meter with the flow arrow indicator on the electronics enclosure pointing in the direction of flow see Figure 5 on page 5). Hand tighten the red NPSM clockwise. Table 2. Model 2300 retrofit compatibility to Signet fittings Size Inches Material Note 1 CPVC PVC PVDF Polypropylene 0.5 Not compatible Not compatible SFMT005 Union Tee PPMT005 Union Tee 0.75 Not compatible Not compatible SFMT007 Union Tee PPMT007 Union Tee 1 Not compatible Not compatible SFMT010 Union Tee PPMT010 Union Tee 1.25 CPV8T012F Tee CPV8T012 Saddle 1.5 CPV8T015F Tee CPV8T015 Saddle CPV8T015F Tee CPV8T012 Saddle CPV8T015F Tee CPV8T015 Saddle SFMT012 Union Tee SFMT015 Union Tee PPMT012 Union Tee PPMT015 Union Tee 2 N/A N/A SFMT020 Union Tee PPMT020 Union Tee 2.5 N/A N/A SFMT025 Wafer PPMT025 Wafer 3 N/A N/A SFMT035 Wafer PPMT030 Wafer 4 N/A N/A SFMT040 Wafer PPMT040 Wafer 5 N/A N/A SFMT050 Wafer PPMT050 Wafer 6 N/A N/A SFMT060 Wafer PPMT060 Wafer 8 N/A N/A SFMT080 Wafer PPMT080 Wafer Note 1 Consult factory for stainless steel tee fitting retrofits. Making Electrical Connections The pulse output of the Hydro-Flow flow meter functions by momentarily shorting the (+) terminal to the ( ) terminal. If the flow meter is connected directly to a DC power source without the series resistor, both the flow meter and the power source may be damaged. Note: If the flow meter is wired backwards to the current-limited power source, the flow meter will not be damaged but it will not function properly. Page 6 Making Electrical Connections 5700508-B

Hydro-Flow Model 2300 Insertion Vortex Flow Meter Pulse Output Electrical Installation The Hydro-Flow pulse output flow meter may be used with a 10 VDC to 32 VDC power supply and series current limiting resistor. The voltage at the flow meter terminals is internally limited to 8.0 ±1.0 VDC under noflow conditions, dropping to less than 1.0 volt for the 2.5 to 5 millisecond duration of the output pulse. Figure 7 on page 7 illustrates a typical installation. Note: The totalizer or flow computer input must be rated for an 8-volt pulse input. Cabling (Pulse Output) The cable may be up to 2000 feet of #20 AWG or larger shielded two-conductor cable. The shield lead from the meter may be connected to an earth ground, such as a copper cold water pipe. The shield improves noise immunity and provides a return path for electrical surges. Its use is optional in installations in which electrical transients and noise are not a problem. Current Limiting Resistor (Pulse Output) The current limiting resistor is required to limit the normal operating current in the flow meter to a value between 5 ma and 20 ma (with a meter voltage of 8 volts and less than 25 ma). The value of the resistor is determined by the power supply voltage, the operating meter current, and the cable resistance. Table 3 lists standard 1/2 watt 5% resistor values which will work in most installations. For power supply voltages between those in the table, use the lower value of resistor. Table 3. Current limiting resistor (pulse output) Supply Voltage (DC) Current Limiting Resister Values (Ω) Minimum Maximum 10 400 400 12 480 800 14 560 1200 16 640 1600 18 720 2000 20 800 2400 22 880 2800 24 960 3200 26 1040 3600 28 1120 4000 30 1200 4400 32 1280 4800 Figure 7. Wiring diagram (pulse output) Page 7 Making Electrical Connections 5700508-B

Advanced Energy 4 ma to 20 ma Current Output or No Output (Display Only) Electrical Installation The Hydro-Flow flow meter may be configured to output a 4 ma to 20 ma analog signal proportional to flow rate. Figure 8. Wiring diagram (4 ma to 20 ma current loop) Cabling (4 ma to 20 ma Output or No Output) Load Resistances (4 ma to 20 ma Output) The flow meter may be connected with up to 2000 feet of #22 AWG or larger cable. Shielded cable may be necessary in some environments to reduce electrical noise; if used, the shield should be connected at one end only to an earth ground point, such as a copper cold water pipe. Figure 9. Maximum load resistance (4 ma to 20 ma output) Hydro-Flow Model 2300 Flow Ranges Table 4. Model 2300 flow ranges Line Size Inches (mm) Minimum Flow (gpm) Maximum Flow Minimum Flow (m 3 /h) Maximum Flow 0.5" (15) 1.0 13.7 0.24 0.75" (20) 1.6 23 0.36 1" (25) 2.6 40 0.6 1.25" (30) 4.0 60 0.9 1.5" (40) 7.0 103 1.6 3.1 5.2 9.1 13.8 23.5 38.1 51.9 78.1 126.7 194.4 278.5 500.6 Pulses/ gal Note 1 550 330 200 125 75 45 35 20 15 10 5 3 Pulses/ m 3 Note 1 150000 85000 55000 35000 20000 12000 9000 6000 3500 2500 1500 1000 Note 1 When flow meter is configured for pulse output. 2" (50) 11.4 168 2.6 2.5" (65) 15.4 228 3.6 3" (80) 23.4 348 5.4 4" (100) 36.6 558 8.4 5" (125) 56.6 855 13.0 6" (150) 81.6 1226 18.6 8" (200) 146.6 2204 33.4 Page 8 Hydro-Flow Model 2300 Flow Ranges 5700508-B

Hydro-Flow Model 2300 Insertion Vortex Flow Meter Mechanical Specifications Table 5. Mechanical specifications Type Measurable fluids Pipe sizes Process pressure/ temperature Ambient temperature Flow range Measuring units Accuracy (combined linearity and repeatability) Wetted parts Mounting options Straight run piping Insertion Ultrapure water, deionized water, acids, solvents, and water 0.5" to 8" (15 mm to 200 mm) See Figure 10-20 ºF to 140 ºF (-29 ºC to 60 ºC) Minimum: 1.0 foot per second (0.3 meters per second) Minimum: 15 feet per second (4.5 meters per second) English: Gallons Metric: Cubic meters Note: Other measuring units available upon request or measuring units can be reconfigured using Hydro-Flow Field-Pro software. ±1.0% of full scale Sensor/Bar/Stem: PVDF O-rings: Viton Retrofit: Fits existing +GF+ Signet tee fitting (see Retrofit Installation on page 6) Union Tee Fitting: PVDF or PP for 0.5" to 1.5" Tee Fitting: CPVC or PVC for 0.5" to 1.5" Wafer: PVDF or PP for 2" to 8"; CPVC or PVC for 0.5" to 1.5" Typical 10 diameters upstream, 5 diameters downstream. Note: For more information, see Straight Run Requirements on page 3. Figure 10. Process pressure/temperature Electrical Specifications Table 6. Electrical specifications Enclosure Reinforced polycarbonate, NEMA 6 CE mark Approved Output signal options Pulse output: frequency proportional to flow rate. Power supply: 10 VDC to 32 VDC power supply with current limited by series resistance to between 5 ma and 20 ma. Maximum pulse width is 5 ms. See Table 4 on page 8 for standard output scaling. Other pulse output settings can be configured by the factory or reconfigured in the field using Hydro-Flow Field-Pro software. Analog output: 4 ma to 20 ma analog current loop, current proportional to flow rate. Power supply: 10 VDC to 32 VDC compliance. 4 ma = zero flow; 20 ma = maximum flow listed in Table 4 on page 8. Display option Other 20 ma settings can be configured by the factory or reconfigured in the field using Hydro-Flow Field-Pro software. LCD display alternately shows 4-digit rate and 8-digit total flow. Page 9 Mechanical Specifications 5700508-B

EMCO Flow Systems Support For product support or more information on EMCO Industrial Flow Products, contact: EMCO Sales Advanced Energy 1625 Sharp Point Drive Fort Collins, CO 80525 USA Phone: 800-356-9362 or 970-407-6949 Fax: 970-407-5179 Email: support@emcoflow.com www.emcoflow.com www.advanced-energy.com The complete EMCO product line for liquid, gas, and steam applications includes industrial inline vortex, industrial insertion vortex and turbine, commercial vortex, electromagnetic, and clamp-on ultrasonic flow products. For more information about EMCO products, refer to the EMCO website (http://www.emcoflow.com/literature/). Trademark Information is a registered trademark of Advanced Energy Industries, Inc. Advanced Energy is a registered trademark of Advanced Energy Industries, Inc. AE is a registered trademark of Advanced Energy Industries, Inc. Ultem is a registered trademark of General Electric Company Vitron is a registered trademark of DuPont Dow Elastomers AE, World Headquarters 1625 Sharp Point Drive Fort Collins, CO 80525 USA Phone: 800.446.9167 or 970.221.0108 or 970.221.4670 Fax: 970.407.5981