Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

Similar documents
SATRON VT Pressure Transmitter

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Multivariable Vortex Flow Meter

JUMO dtrans p20 DELTA

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

VLM20 In-line Vortex Flowmeter

Multivariable Vortex Flow Meter

VersaFlow Vortex 100 Vortex Flow Meter Specifications

SATRON VDt Differential Pressure Transmitter

Magnetic-inductive flow meter for hazardous areas

Pressure transducer DMU 01K Compact version

Flow VA 550 / 570. DVGW tested. Flow.

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Turbine flowmeters Series TM

F-2600 SERIES INLINE VORTEX FLOW METER

Transmitting Transducer. Gas/Air Velocity Range:

Pressure transmitter JUMO dtrans p02

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Magnetic Inductive Flowmeter EP / UMF2 (B)

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

SATRON VVFe Pressure Transmitter

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

SITRANS P measuring instruments for pressure

SATRON VTe pressure transmitter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

2600T Series Pressure Transmitter

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

Cable resistance thermometer Model TR40

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Cable resistance thermometer Model TR40

Pressure sensor for liquid and gaseous media QBE620-P...

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Positive displacement batch controller

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

OPTISWIRL 4070 Technical Datasheet

Cable resistance thermometer Model TR40

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

OPTIMASS 3000 Technical Datasheet

F-2700 SERIES INSERTION VORTEX FLOW METER

Options guide. Electromagnetic flowmeters. M9xx

OPTISWIRL 4070 Technical Datasheet

ISTEC MAGNETIC METERS

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

TORRIX Magnetostrictive level sensor

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Data Sheet Calibration / Testing. calibration flat rate not included Type Description Article No. Visual inspection, cleaning, performance

Solenoid Valves Type 3963

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

STEEMCO Flowmeter for Steam

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

Flowmeter MDW 500. description. 230 VAC (50/60 Hz), 24 VAC/VDC with polarity reversal protection, 110VAC(60Hz) on request

Smart Pressure Transmitter

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

STEEMCO-MAS Flowmeter for Steam

Flap-Type Flow Meter Prall

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

mass flowmeter for compressed air

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Metal tube variable area flowmeter for gases, liquids and steam

F-1500 SERIES INSERTION TURBINE FLOW METER

SITRANS F X SITRANS FX300 3/355

Differential pressure sensor

K - Flow Meter with Float

Digital ph transmitter

Design and application

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

ORIMAS Mass Flowmeter

F-2500 SERIES VORTEX METER

Paddle-wheel flow controller for On/Off control

Flowmeter for Gases. Type Type can be combined with... Type 8802-YG Process control valve. Type 5281 Solenoid valve

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

Electronic Limit Switch Type

OPTIGAS 4010C Technical Datasheet

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

BATCHFLUX 5500 C Technical Datasheet

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

VIM20 Vortex Insertion Flowmeter

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

F-2700 SERIES INSERTION VORTEX FLOW METER

OPTISWITCH 4000/5000. Vibration level switches for liquids

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Differential Pressure Sensors

GA 24 Heavy-duty variable area flowmeter

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

mass flowmeter for compressed air

Transcription:

Vortex Flow Sensors VA Di Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases Drawing 1 Measurable variable actual flow rate standard velocity standard flow rate (in combination with pressure and temperature sensors) Design measuring tube Functional principle vortex meter for measuring flow rate and volume ultrasonic measurement of the vortex shedding Medium primarily single-phase gas mixtures with air, nitrogen, oxygen, methane, natural gas, flare gas, ammonia, argon, carbon monoxide, steam... as dominant component, combustion exhaust gas, bio gas, sewage gas. Other gases on request. Advantages low starting value high measuring dynamics (up to 1 : 100) no moving parts maximum fatigue strength corrosion resistant operates to a large extent irrespective of gas composition low pressure drop easy adjustment to process parameter Range and examples of application flow measurement, for example, of air, exhaust gas, process gas, bio and sewage gas, engine intake air, exhaust emissions, gases laden with particles, dust and fibres, superheated steam Particles, condensation, humidity in the gas charges in the gas caused by particles such as dust and fibres do not affect the measurement, as long as abrasion and agglomeration do not occur on the sensor relative gas humidity of less than 100 % does not affect the measurement uncertainty depending on the density, condensation on the sensor may affect measurements. The vortex signal processing module VSM can help reduce measurement uncertainty if condensation is moderate; requirement: external evalutation unit instead of integrated transducer UVA 1/6

Model designation / order code (example) VA Di 25 G E 40 m/s p10 ZG1 (1) (2) (3) (4) (5) (6) Basic types Type without integrated transducer UVA (output v/va or v/va-ex) with integrated transducer UVA (output 4-20 ma or 0-10 V) VA Di 25 GE 25 m/s / p10 ZG1 b015/010 b015/015 VA Di 25 GT 25 m/s / p10 ZG1 b015/020 b015/025 VA Di 25 GH 25 m/s / p10 ZG1 b015/030 b015/035 VA Di 25 GL 25 m/s / p10 ZG1 b015/040 b015/045 VA Di 40 GE 30 m/s / p10 ZG1 b015/011 b015/016 VA Di 40 GT 30 m/s / p10 ZG1 b015/021 b015/026 VA Di 40 GH 30 m/s / p10 ZG1 b015/031 b015/036 VA Di 40 GL 30 m/s / p10 ZG1 b015/041 b015/046 VA Di 50 GE 30 m/s / p10 ZG1 b015/012 b015/017 VA Di 50 GT 30 m/s / p10 ZG1 b015/022 b015/027 VA Di 50 GH 30 m/s / p10 ZG1 b015/032 b015/037 VA Di 50 GL 30 m/s / p10 ZG1 b015/042 b015/047 VA Di 80 GE 40 m/s / p10 ZG1 b015/013 b015/018 VA Di 80 GT 40 m/s / p10 ZG1 b015/023 b015/028 VA Di 80 GH 40 m/s / p10 ZG1 b015/033 b015/038 VA Di 80 GL 40 m/s / p10 ZG1 b015/043 b015/048 VA Di 100 GE 40 m/s / p10 ZG1 b015/014 b015/019 VA Di 100 GT 40 m/s / p10 ZG1 b015/024 b015/029 VA Di 100 GH 40 m/s / p10 ZG1 b015/034 b015/039 VA Di 100 GL 40 m/s / p10 ZG1 b015/044 b015/049 aa : price on request (1) Dimensions tube flange inside Ø outside Ø Di D flange thickness b hole circle Ø k hole Ø d no. of holes sensor length sensor height H sensor weight 25 115 16 85 14 4 200 245 8 40 150 16 110 18 4 200 250 10 50 165 18 125 18 4 200 250 10 80 200 20 160 18 8 200 270 12 100 220 20 180 18 8 200 286 15 flange dimensions as per DIN 2527 PN16 Form C (other flange dimensions on request) (2) Medium Gases [kg] 2/6

(3) Materials in contact with the medium design material... GE... stainless steel 1.4571, ceramics... GT... titanium 3.7161, ceramics... GH... Hastelloy 2.4610 (HC4), ceramics... GL... tantalum, ceramics (4) Measuring range Di flow rate [m³/h] 25 0.7... 44 0.4... 25 40 1.8... 135 0.4... 30 50 2.8... 212 0.4... 30 80 7.2... 724 0.4... 40 100 11.0... 1131 0.4... 40 average flow velocity [m/s] measurement uncertainty repeatability input/output sections < 1 % of measured value + 0.3 % of terminal value (at +20 C / 1000 hpa) ± (0.2 % of measured value + 0.025 % of terminal value) in order to achieve as great a measurement accuracy as possible, an input/output section of 20/10 x Di is recommended. The input section can be reduced considerably by using a flow rectifier (see Accessories). Further information on this subject can be found in the Operating Instructions U283_VADi_B_e. (5) Max. working pressure up to 10 bar / 1 MPa overpressure (6) Design as in Drawing 1 Connection housing AS102 Dimensions L/W/H: 100/80/150 mm Material die-cast aluminium G Al Si12 / DIN 1725 Protection class IP65, IEC 529 and EN 60 529 Connection bush for shielded cables with external diameter 5... 10 mm, contacting of the overall copper shielding by the metallic screwed cable glands Electromagnetic compatibility (EMC) according to EN 61 000-6-2 / IEC77 Mounting attitude any to ensure that the sensor remains operative in horizontal pipeline even with moderate condensation, sensors VA Di 25 should be installed with the connection housing pointing upwards, and sensors VA Di 40, VA Di 50, VA Di 80 and VA Di 100 with the connection housing pointing sideways. In vertical pipeline the attitude for all sensors VA Di... - also in case of moderate condensation - can be chosen freely. 3/6

Options (A)... (C) sealing material calibration pressure Ex-protection (A) (B) (C) Option (A) material working temperature range of the medium permissible ambient temperature with separate evaluation unit with integrated transducer UVA VITON -20... +180 C -20... +80 C -20... +50 C b015/900 (standard) silicone -40... +180 C -40... +80 C -25... +50 C b015/901 KALREZ (Compound 4079) 0... +180 C 0... +80 C 0... +50 C b015/902 EPDM -20... +160 C -20... +80 C -20... +50 C b015/903 permissible ambient temperature 0... +50 C with integrated display Option (B) calibration pressure comment atmospheric pressure bar rel. with working pressures greater than 3 bar rel. calibration should be carried out at average working pressure to reduce the risk of measurement uncertainty calibration pressure selectable in range 1... 10 bar rel.; with working pressures greater than 3 bar rel. calibration at average working pressure is recommended to ensure the smallest possible measurement uncertainty b015/910 b015/911 Option (C) type of protection comment EEx ia IIC T6 only in conjunction with: vaex0 gas-ex: category 1/2G (zone 0) dust-ex: category 1/2D (zone 20) isolation/supply unit LDX2 and 'non-ex evaluation unit' or compatible separate evaluation unit with Ex-input (see below) temperature range of the medium as electrical apparatus for Category 1/2G 20...+60 C; 2G 40...+180 C; 1/2D, 2D 40...+180 C Ex na IIC T6 category 3G (zone 2) vaex2 Output v/va, v/va-ex, 4-20 ma or 0-10 V output sensor v/va Höntzsch evaluation unit ** with v/va input is necessary for signal interpretation output sensor v/va-ex, Höntzsch evaluation unit** with intrinsically safe input v/va-ex or (sensor with Option (C) an evaluation unit with input v/va** together with a series connection see above) isolation/supply unit LDX is necessary for signal interpretation output 4-20mA or 0-10V with transducer UVA integrated in the connection housing (see Page 5) ** e. g. RP Vortex, VT-VA, VP-VA or VT-VA 4/6

optional transducer UVA, integrated in the sensor connection housing analog output flow 4-20 ma or 0-10 V (please select) 4... 20 ma resistance max. 400 Ohm b015/050 0... 10 V impedance max. 1 kohm b015/051 output limit value or quantity pulse potential-free relay contact (normally open contact), max. 300 ma / 27 VDC PC interface RS232 output signals are electrically isolated from the power supply self-monitoring parameter settings,sensor interface; in case of error: analog output less than 3.6 ma or <-0.2 V connection 'push in' PCB terminals; no tools necessary for strand connection; disconnect strands by applying pressure with a pen or screwdriver; for strands with cross-section 0.14... 1.5 mm² power supply 24 V DC (20... 27 V DC) power consumption less than 5 W setting parameter analog output, time constant, profile factor, tube inside diameter, limit value or quantity pulse (quality rating adjustable), switch from actual/standard flow with setting parameters 'working pressure' and 'working temperature' setting parameter with PC software UCOM and PC connection cable (see Accessories) alterable compatible separate evaluation units (necessary in conjunction with VA Di sensors without integrated transducer UVA) for non-ex applications UVA, RP-Vortex, VT-VA, VP-VA, VTP-VA for Ex-applications 1) isolation/supply unit LDX2 in LDG16 housing in combination with evaluation units UVA, RP-Vortex, VT-VA, VP-VA, VTP-VA in LDG housing (additional requirement: Ex-input t, p) 2) RP-Vortex, VT-VA, VP-VA, VTP-VA with Ex-input in other housing versions Accessories (optional) LCD in housing cover* Calibration certificate description Line 1: 'instantaneous value': flow rate or flow velocity Line 2: 'quantity counter' or 'error code'; 2 x 16 digit, character height 5.5 mm, working temperature range 0... +50 C a010/016 klbneu PC software UCOM* PC connection cable RJ22 / sub-d 9-pin* Interface converter* USB / RS232 for configuring transducers UFA and UVA via RS232 interface, PC connection cable RJ22 / sub-d 9-pin additional requirement for configuring transducers UFA and UVA in LDG16 or AS102 housing via RS232 interface together with UCOM software; transducer connection: RJ22 PC connection: sub-d 9-pin for connecting PC to USB port and Höntzsch programming adapter to RS232 interface; PC connection: USB plug type A prog. adapter connection: sub-d 9-pin * only in conjunction with integrated transducer UVA (see above) a010/052 a010/051 a010/100 5/6

Accessories (cont.) Process flange TP for one temperature sensor (T) and one pressure sensor (P) identification inside diameter Di TP Di/DN 25 PN16 b015/100 25 TP Di/DN 40 PN16 b015/101 40 TP Di/DN 50 PN16 b015/102 50 TP Di/DN 80 PN16 b015/103 80 TP Di/DN100 PN16 b015/104 100 Material stainless steel 1.4571 Connecting thread 2 x G 1/4 " Installation point down stream, behind the VA Di sensor Flow rectifier for reducing the input section - including flow rectifier - to 11 x Di Identification Inside diameter Di GL Di/DN 25 PN16 b015/150 25 GL Di/DN 40 PN16 b015/151 40 GL Di/DN 50 PN16 b015/152 50 GL Di/DN 80 PN16 b015/153 80 GL Di/DN 100 PN16 b015/154 100 Material stainless steel 1.4571 Installation point 5... 8 x Di in front of the VA Di sensor (see Operating Instructions U283_VADi_B_d) Trademark Dupont Höntzsch GmbH Gottlieb-Daimler-Straße 37 D-71334 Waiblingen (Hegnach) Tel: +49 7151 / 17 16-0 Fax: +49 7151 / 5 84 02 E-Mail info@hoentzsch.com Internet www.hoentzsch.com Subject to alteration 6/6