Installation & Operation Manual

Similar documents
ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Harris IRT Enterprises Digital Resistance Tester Model XP

1.Safe testing IMPORTANT:

MSR01. Water heating controller with solar panel support

User Manual. Rev USER MANUAL MForks 1

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

DANGER. See Wiring Diagrams on page 7 for illustrations of both internal and connection wiring diagrams. WARNING

SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

MX2040, DYNAMIC SIGNAL CHECKER Instruction Manual

KEWTECH. KT56 digital multi function tester. Instruction manual

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

University of Delaware

PQube 3 Modbus Interface

Refrigerated incubator with Peltier technology

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Power Switching Devices

Sola/Hevi-Duty S3K Series Mini-Tower UPS

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

TECHNICAL DATA SHEET LAD/CYCLER16KW

CNC Tool Room Milling Center MODEL: VM-760

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

Climate chambers with illumination

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

BATTERY CHARGERS FAN COOLED HIGH FREQUENCY CHARGERS UP 30% ENERGY SAVINGS! HIGH FREQUENCY BUILT-IN CHARGER AQHF24-30FC G2 TECHNICAL PECIFICATIONS

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Instructions Manual Control Unit RCU205

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

POWER METERS. Easy insight into power consumption VPINSTRUMENTS.COM

Uninterruptible Power System

Digital Transformer Ratiometer

MKT 240 (E3) - Environmental simulation chamber for complex temperature profiles in the low temperature range

Heating oven with mechanical control

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Climate chamber with illumination

Installation Guide TB499 Conveyor/Dryer/Stacker Part #: M-3250 Revision Date:

University of Houston Master Construction Specifications Insert Project Name

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Heating oven with mechanical convection

SE-400 MANUAL GROUND-FAULT-RELAY TEST UNIT

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Application of AC Dahlander Three-Phase Induction Motor AEL-ACDHA

CTFRP Series Power Supplies

Bulletin 825 SMM Smart Motor Manager

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

ValveLink SNAP-ON Application

AMS ValveLink SNAP-ON Applications

Operating Instructions incl. Declaration of Conformity. Controller RVC 300 BG BE / C ( ) 1

KMP Insulation-Continuity Tester. Users Manual

Electromagnetic Flowmeters. Product Overview.

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

Model ED 720 Drying and heating chambers Classic.Line with natural convection

A419ABG-3C Electronic Temperature Control

Virtual Measurements & Control. VC210 Operators Manual

TA-2 RANGE OF THERMAL ANEMOMETERS

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

RT2DB Excitation and voltage regulation system for synchronous generators

User Manual Digital Water Level Indicator for rain water storage tanks

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Application of AC Three-Phase Induction Motor of Squirrel Cage AEL-ACINA

Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA

MIT515, MIT525, MIT1025, MIT1525

Portable Surge Protective Device Tester SPD T8 tester User Manual

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

EM DC Multi-Function DC Energy Meter

ValveMate 7000 Controller Operating Manual

MODEL 3567A. Digital MΩ Tester. Instruction Manual

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

RAPTOR DEFAULT TEST TEMPLATES

Advanced Materials The Key to Progress

Foreword

PRODUCT REQUIREMENTS

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

5 kv and 10 kv Insulation Resistance

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

Automatic DC Power Supply/Battery Charger

TMD90A Dual Input Digital Thermometer

Buck BioAire Model B520 Instruction Manual

EGT-100 Operations and Installation Manual

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

RU BMS Power Supply and Battery Management System Owners Guide

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

DC REGULATED POWER SUPPLY

S1-568, S1-1068, S1-1568

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

Electronic lubrication control unit

BATTERY SAVER LOW RIPPLE HO

Transcription:

EDL175 Portable Event & Data Logger-Extended Range Installation & Operation Manual BG0447 REV. A3

LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for faulty workmanship or parts from date of dispatch from the distributor. In all cases, this warranty is valid for 36 months from the date of production. This warranty is on a return to factory basis. The manufacturer does not accept liability for any damage caused by instrument malfunction. The manufacturer accepts no responsibility for the suitability of the instrument to the application for which it was purchased. Failure to install, setup or operate the instrument according to the instructions herein will void the warranty. Your instrument may be opened only by a duly authorized representative of the manufacturer. The unit should only be opened in a fully anti-static environment. Failure to do so may damage the electronic components and will void the warranty. NOTE The greatest care has been taken to manufacture and calibrate your instrument. However, these instructions do not cover all possible contingencies that may arise during installation, operation or maintenance, and not all details and variations of this equipment are covered by these instructions. For additional information regarding installation, operation or maintenance of this instrument, contact the manufacturer or your local representative or distributor. This manual provides instructions for using the EDL175. For instructions and information on using the PM175, refer to the PM175 Installation and Operation Manual; for instructions and information on using the PAS software package, refer to the PAS User's Manual included in the accompanying CD for the PM175 Series. BG0447 REV. A1 2

Table of Contents 1. The Portable Event & Data Logger - Extended Range... 4 2. Installation... 8 2.2 Connecting to the Electrical Network...8 2.3 Connecting Voltage and Current Inputs...8 2.4 Wiring Mode Setup...8 2.5 CT Setup...9 2.5.2 Direct Measurement (via clamps)...9 2.5.3 Measurement via External CTs Secondary Current, Clamps and Special Cables... 9 2.6 PT Setup...10 2.7 Voltage Probes Connection...10 2.8 Current Sensors Connection...10 2.8.1 Standard Clamps... 10 2.8.2 Special Cables... 11 2.8.3 Standard FLEX Current Sensors...11 3. Power Supply and Battery... 11 3.1 Internal Battery Power Supply...11 3.2 Indicators...11 3.3 Battery Voltage Measurement...12 4. Specifications... 12 3

The EDL175 Portable Event & Data Logger - Extended Range measures, records and analyzes events and data of electrical network parameters. Being mobile, it enhances efficiency by enabling onsite identification of power problems. The EDL175 meets the requirements of a wide range of applications, from events analysis to energy auditing and load profile recording over a period of time. The EDL175 parameters include all the measurement and logging capabilities of the PM175 Powermeter in a convenient, portable package. The manufacturer s PAS software package included in the EDL175 provides graphic data display and analysis capabilities. The EDL175 is suitable for direct measurement of voltages up to 660V (or greater when using a Potential Transformer). The EDL175 is equipped with standard clamps with secondary current of 1A. It is also possible to use FLEX sensors with secondary voltage of 2VAC or 3VAC or standard clamps with secondary voltage up to 2VAC or 3VAC. The EDL175 can measure low currents in the range of 100mA to 10A, in addition to the standard ranges, with a high degree of accuracy, using standard high current clamps. This additional measurement capability is made possible by the combination of standard current clamps and the manufacturer's special cables and electronic circuit. One application is using standard current clamps to measure the standard 5A output CTs. Figure 1-1 Standard Contents of EDL175 The EDL175 has an internal DC battery which enables it to continue working even when the power supply is disconnected for short intervals, as in a power failure. The contents of the EDL175 case are shown in Figures 1-1 through 1-4. Instrument dimensions are shown in Figure 1-5. Section 2 of this manual provides installation instructions, including wiring mode, CT and PT setup, as well as connection of voltage probes and current sensors. Section 3 provides information on the internal battery and an explanation of the EDL175 indicator lights. 4

Figure 1-1 Standard Contents of EDL175 1 EDL175 Display 2 PM175 Status Inputs Connector - see Figure 1-2 for detail 3 PM175 Relays Connector - see Figure 1-2 for detail 4 Communication Port (RS-232) 5 Low battery LED BAT LOW (red, blinking) and Buzzer 6 AC Power LED (green) 7 Battery LED BAT (red) 8 Slide switch operating voltage supply 9 Battery and Battery Fuse 10 Battery Voltage measurement sockets 11 Voltage inputs 12 Current Terminals 13 Current Inputs 14 Power Supply Socket & Fuse Housing 15 Network neon light 16 PM175 Analog I/O (Option) Figure 1-2 Detail of Nos. 2,3 and 16 in Figure 1-1 Figure 1-3 Detail of No. 12 in Figure 1-1 NOTE: Connections for relays, status inputs and communications are the same as for the PM175. See the PM175 Installation and Operation Manual for connection drawings and instructions. Analog output is not connected. 5

PM172 Series Figure 1-5 EDL175 Dimensions 16 EDL175 Installation and Operation Manual 16a Series PM175 Installation and Operation Manual 17 Series PM175 CD 18 Current Clamps Set 19 Voltage Probe Set 20 Case for Clamps and Cable 21 Communications Cable 22 Power Supply Cord 23 FLEX current sensors 24 Connection Cables for FLEX current sensors 25 Special cables for current clamps for low current measurement (100mA-10A) 6

7

Read through this section carefully before connecting the EDL175 to the circuit being tested. 2.1 Location The distance between the EDL175 and the current lines must be at least half a meter (1.6 feet) for current lines carrying up to 600A, and at least one meter (3.3 feet) for currents between 600A and 2000A. 2.2 Connecting to the Electrical Network Connect the EDL175 to the AC power supply using the Power Supply Cord (No. 22 on Figure 1-3). Turn the slide switch (No. 8 on Figure 1-1) ON. 2.3 Connecting Voltage and Current Inputs Voltage Inputs are connected using the cables shown in Figure 1-4, no. 19. Current Inputs can be connected by one of four options: Regular Connection via terminal block, see Figure 1-1, no. 12 (same as terminal block of thepm175) Connection via Current Clamps with current source output signal for high current measurement (see Figure 1-4, no. 18) Connection via Current Clamps with current source output signal and Special Cable for low current measurement (see Figure 1-4, nos. 18 and 24) Connection via Current Clamps with voltage source output signal or via Flexible Current Sensors and Connection Cables for FLEX Current Sensors (see Figure 1-4, nos. 23 and 24) Note: Even if measuring only one phase current, all current sensors must be connected. 2.4 Wiring Mode Setup Wiring mode of the EDL175 is the same as for the PM175. For setup of the wiring mode directly on the EDL175 front panel, refer to Table 4-1 of the PM175 Installation and Operation Manual or the PAS User s Manual, Section 6.1.1. 8

2.5 CT Setup Set up the CT according to the PM175 Installation and Operation Manual, Table 4-1 or the PASUser s Manual, Section 6.1.1. 2.5.1 Normal Measurement Set the CT = 1. 2.5.2 Direct Measurement (via clamps) All clamps require the CT according to the following formula: CT = I1ncl / I2ncl where: I1ncl and I2ncl are the clamp nominal primary and secondary currents. Examples: 1) I1ncl =1000A and I2ncl =1A; CT=1000 2) I1ncl =1000A and I2ncl =5A; CT=200 3) I1ncl =200A and I2ncl =1A; CT=200 FLEX sensors and clamps with nominal output voltage of 3V require the CT to be set to the nominal primary current. FLEX sensors and clamps with nominal output voltage of 2V require the CT to be set to 150% of the nominal primary current. Examples: 1) I1ncl =300A, V2ncl = 2V; CT=150 2) I1ncl =3000A, V2ncl = 3V; CT=1500 2.5.3 Measurement via External CTs Secondary Current, Clamps and Special Cables The CT value should be set according to the following formula: CT = (Ip / Is ) (I1ncl / I2ncl) 0.005 where: Ip = external Current Transformer primary nominal current Is = external Current Transformer secondary nominal current Examples: 1. When measuring current without external transformer (Ip / Is=1) via clamp 1000/1, then CT=5, If will be set CT=5000 the instrument display in ma; 2. When measuring secondary of current transformer 3000/5 via clamp 1000/1, then 9

IP = 3000, IS = 5, Ic=1000, CT = (3000/5) (1000/1) 0.005 = 3000. 2.6 PT Setup Set the PT according to the PM175 Installation and Operation Manual, Section 4.1 or the PAS User s Manual, Section 6.1.1. 2.7 Voltage Probes Connection Connect the voltage probes to the EDL175 through the voltage connectors marked V1/V2/V3/VN. Connect the probes to the line conductors according to the power system configuration. 2.8 Current Sensors Connection Connect the current sensors first to the EDL175 and then to the measured circuit. There is a common connector for all types of current sensors in each phase. NOTE: The nominal secondary outputs of the current sensors can be 1A or up to 3V. 2.8.1 Standard Clamps The EDL175 contains a set of standard current clamps with 1A secondary nominal current and primary nominal current according to the order specification (120A / 200A/ 1000A / 3000A). Maximum EDL175 measured current is 200% of the nominal current. All current clamps in the kit have built-in protection against clamp connector disconnection. 10

2.8. 2 Special Cables The manufacturer's special cables, together with the standard clamps, enable the EDL175 to perform measurements on high voltage lines via existing current transformers with 5A nominal secondary current by measuring the output of the current transformers. 2.8. 3 Standard FLEX Current Sensors The EDL175 can work with all standard FLEX and clamp current sensors which have a voltage output up to 3V RMS. The EDL175 provides an optional FLEX connector cable for connection to these current sensors. 3.1 Internal Battery Power Supply 3.2 Indicators The EDL175 includes a rechargeable battery. When fully charged, the battery allows the EDL175 to work for at least 20 minutes. Do not allow the battery to totally discharge. The battery measurement sockets can be used for external 12V battery connection, which will allow prolonged use of the EDL175 in the event of no network power supply. Charging the Battery When the battery is fully discharged (indicated by the buzzer, the blinking LOW BAT lamp and, upon end of discharging, by no display), apply AC voltage to the EDL175 to recharge the battery. The recommended charge time is 8 hours. The following table lists the possible indicated conditions: Green LED AC and network neon light Red LED BAT Red LED LOW BAT ON Off Off ON Off ON Off ON Off ON Blinking & buzzer PM175 Display ON ON Off Off Off Indication EDL175 supplied by external AC power supply; battery is charging slowly EDL175 supplied by internal charged DC battery EDL175 supplied by internal DC power supply; battery needs charging and will disconnect automatically within 5 minutes EDL175 is connected to external AC power supply, slide switch is OFF; battery is charging rapidly 11

3.3 Battery Voltage Measurement The amount of remaining battery charge can be estimated by checking battery voltage (Vbat). This is done by connecting an external voltmeter with internal resistance of greater than 1M_ to the battery measurement sockets (see Figure 1-1, no. 10). If Vbat _ 12V, the battery is operating normally. If Vbat _ 11V, the battery is LOW. If Vbat_10.5V, the battery is fully discharged. Power supply: 100-240 VAC, 45-65 Hz, 30 VA. Battery: rechargeable; 12V/1.2Ah DC. Allows 20 minutes work when fully charged. Long-term storage of the battery is according to the following: Storage temperature +10 C +20 C +30 C +40 C Time before recharging required, in months > 18 14 8 5 Accuracy: The EDL175 accuracy is a function of the accuracies of the PM175, the clamps and the external transformers (PT and CT). Most of the EDL175 measurement error is due to the latter two elements. Figure 2-1 Three wire direct connection using 2 CTs (2-element), Wiring Mode=3dir2 Voltage Probe Set: Construction: 1 black, 3 red, spring loaded. Case material: Polypropylene Case temperature rating: -23 C to 99 C Measurements: Height 300 mm, 11.8 Width 406 mm, 16 Depth 170 mm, 6.7 Weight 6.3 kg, 14 lbs 12

13 Figure 2-2 Three wire direct connection with special cable using 2 CTs (2-element), Wiring Mode=3dir2

14 Figure 2-3 Four Wire WYE Direct Connection Using 3 CTs (3-element) Wiring Mode = 4LL3 or 4Ln3

Figure 2-5 Four Wire WYE Connection with special cables using 3 PTs, 3 CTs (3-element) Wiring Mode = 4LL3 or 4Ln3 Figure 2-4 Four Wire WYE Direct Connection with special cables using 3 CTs (3-element) Wiring Mode = 4LL3 or 4Ln3 15

16 Figure 2-6 Three Wire Open Delta Connection using 2 PTs, 2 CTs (2-element) Wiring Mode = 3OP2

17 Figure 2-7 Three Wire Open Delta Connection with special cables using 2 PTs, 2 CTs (2-element) Wiring Mode = 3OP2

18 Figure 2-8 Three Wire Open Delta Connection with special cables using 2 PTs, 2 CTs (2-element) Wiring Mode = 3OP2

19 Figure 2-9 Four Wire Wye Connection with special cables using 2 PTs, 3 CTs (2½-element) Wiring Mode = 3LL3 or 3Ln3

20 Figure 2-10 Three Wire Open Delta Connection with special cables using 2 PTs, 3 CTs (2½-element) Wiring Mode = 3OP3

21 Figure 2-11 Four Wire Delta Direct Connection using 3 CTs (3 element) Wiring Mode = 4LL3 or 4Ln3

22 Figure 2-12 Four Wire Delta Direct Connection with special cables using 3 CTs (3 element) Wiring Mode = 4LL3 or 4Ln3

䘀椀最甀爀攀.......................................... 23