Novel High Efficiency UPS System

Similar documents
TECHNICAL DATA SHEET KVA UPS Systemss

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

MKN-DSP SERIES - THREE PHASE

Technical data sheets

UPS SYSTEMS PDUs SURGE PROTECTORS POWER INVERTERS DATACENTER UPS. Product Catalog

Development of Higher-voltage Direct Current Power Feeding System for ICT Equipment

PowerWave 33 Efficient power protection for today s IT and process-related work environments

D Series: UPS UPTO - 300KVA - Three / Three Phase

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Development of the Small-Capacity UPS SANUPS A11K Series

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

POWER kva

EFFEKTA Power Supplies

High Speed V-Series of Fast Discrete IGBTs

POWER kva

3ph UPS NS3000 series kVA

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MGE TM Galaxy TM 7000 GFC

MGE TM Galaxy TM 7000

Security Plus Online Uninterruptible Power Supply

Master Plus kva

YOUR POWER IN SAFE HANDS. E Series UPS

Technical Data Sheets

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Master DIALOG INDUSTRY RANGE

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Development of Small-capacity OFF-LINE UPS

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Development of the Single Phase PV Inverter SANUPS P61A

Sirius series. UPS kva single/single-phase and three/single-phase kva three/three-phase. online

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

PVI1000 : Outdoor High-Efficiency Power Conditioners for Mega Solar Projects

EAST GROUP COMPANY PROFILE. Energy storage solutions. About us. Grid-connected PV systems. Our Products. Our Team. UPS solutions

MASTERYS IP+ 10 to 80 kva

ConceptpowerTM Modular kVA

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Sustainable Energy Mod.1: Fuel Cells & Distributed Generation Systems

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

Onfiniti. 1 Phase UPS

Est DCM Double Conversion Module 400kVA - 800kVA

Technical Data Sheets

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Liebert. FP 50Z kva

TECHNICAL SPECIFICATIONS

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Technical Data Sheets

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Development of Uninterruptible Power Supply SANUPS A11J Three-phase, Four-wire Model

Technical Data Sheets

2033A Series. Where Reliability Breeds Confidence UNINTERRUPTIBLE POWER SUPPLY SYSTEMS ISO 9001 CERTIFIED

A new static DC drive system with AFE for mining excavators

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Large-scale Photovoltaic Power Generation Systems

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Three Phase UPS Systems Range: 10 to 500kVA

Industrial PFC UPS System

Achieves a high-efficiency conversion of 94% despite being isolated type through digital control

TOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

PowerWave 33, kw

Phase Modular Finally the benefits of Modular ups are for all

Power Electronics Projects

SIRIUS Online UPS. data CeNTReS. TeleCoMMUNICATIoN devices. MedICAl devices. emergency devices. TRANSPoRTATIoN. Smart Energy Solutions

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

Technical Data Sheets

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

ABB Data Center Solutions Day 5 July 2013 by Kelvin Sim Myths or Truths: Achieving 99% Efficiency with Single Conversion Backup Power System

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Inform Company Profile

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Standby Power Systems

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

TLE Series UPS 400/500 kw With eboost Technology

Features and Benefits

OFFICE SIEL ENERGY SYSTEMS LTD NITESCO LLC

Uninterruptible Power System

Speed Enhancement for the 3rd-Generation Direct Liquid Cooling Power Modules for Automotive Applications with RC-IGBT

DP INNOVATION. A Novel Solution to Common Mode Failures in DP Class 2 Power Plant

Huawei UPS2000-G Solutions

Transcription:

Novel High Efficiency UPS System Yasuhiro OKUMA Senior General Manager Technology Planning Department Power Electronics Development Center Technology Development Group Fuji Electric Systems Co., Ltd. 1

Agenda 1. Background 2. Trend of Fuji UPS Technology 3. Series Parallel Processing Topology >Principal >Realization 4. New Products: 8000 Series ( Three-phase, Large Capacity ) 5. New Products: GX Series ( Single-phase, Small Capacity ) 6. Conclusion 2

Agenda 1. Background 2. Trend of Fuji UPS Technology 3. Series Parallel Processing Topology >Principal >Realization 4. New Products: 8000 Series ( Three-phase, Large Capacity ) 5. New Products: GX Series ( Single-phase, Small Capacity ) 6. Conclusion 3

Background 1997: Kyoto Protocol 1998: Promotion of the Measures to Cope with Global Warming 2008: Law Regarding the Rationalization of Energy Use 2007: The Green Grid ( DCD, PUE ) Climate Savers Computing Initiative ( High Efficiency ) The function and the performance were important so far. Hereafter, efficiency becomes the most important. Fuji Electric has worked on the development of high efficiency UPS since 2000. 4

Agenda 1. Background 2. Trend of Fuji UPS Technology 3. Series Parallel Processing Topology >Principal >Realization 4. New Products: 8000 Series ( Three-phase, Large Capacity ) 5. New Products: GX Series ( Single-phase, Small Capacity ) 6. Conclusion 5

Trend of Fuji UPS Technology Items 1975 1980 1985 1990 1995 2000 Requirement Power Device Topologies MOSFET Thyristors GTO Power Transistors IGBT IPM [ Self arc-suppression, Rapid Switching, Low Loss, Low Drive Power ] Online Double conversion Line Interactive New Conversion Compact, High efficiency More reliability Low cost High Efficiency (Energy Saving) Contact Interface Serial Port 1 st. Gen. LAN Applicable (network OS) 2 nd. Gen. LAN (SNMP etc) High Reliability User Friendly Auto Shutdown at Blackout Scheduled Operation Total Managing System Inverter Multiplied Inverter Low Freq. PWM High Freq. PWM (Carrier F < = 1kHz) (Carrier F > 5kHz) = Compact in size Rectifier 6 Pulse, 12 Pulse Rectifier High Power Factor Rectifier Low THDi Higher Spec (High Pf-in) Controller Control Dev. Control Top. Discrete IC, LSI Analog Control Microprocessor, DSP, ASIC Digital Control High Reliability User Friendly Higher Spec. Non-linear load Storage Batteries Catalytic Plug Valve Regulated Lead Acid Capacitors, FW Maintenance, Lifetime Downsizing Environment, RoHS 6

Agenda 1. Background 2. Trend of UPS Technology 3. Series Parallel Processing Topology >Principal >Realization 4. New Products: 8000 Series ( Three-phase, Large Capacity ) 5. New Products: GX Series ( Single-phase, Small Capacity ) 6. Conclusion 7

Series Parallel Processing Topology What is Suitable Principal for High Efficiency? Voltage Stability Reduce Volume Efficiency Suitable for UPS Double Conversion High Low Low High Parallel Processing Low Mid High Mid SMR+Inv. High High Low Mid Direct Conversion High Mid High Low Line Interactive Mid Low Mid Mid Series Processing High High High Low We need new Topology!! Series Parallel Processing Topology 8

Series Parallel Processing Topology Why do we choose Series Parallel Processing Topology? Double Conversion ac dc High Performance dc ac Low Efficiency Series Parallel Processing Parallel Processing ac dc Series Conv. dc ac Parallel Conv. dc ac Low Performance High Efficiency High Performance High Efficiency 9

Series Parallel Processing Topology Principal Series Processing dc Series Parallel Processing ac Voltage Compensator Parallel Processing ac dc Series Conv. dc ac Parallel Conv. dc ac Series Conv. : Voltage Compensator Function Parallel Conv. : Active Filter & Parallel Inverter Function Active Filter 10

Series Parallel Processing Topology Realization: Three-Phase System How did we achieve smooth changing operation? <Normal Mode> V V I I Th 2 Th 1 V AVR S-Con. P-Con. Th 1 Active filter & PFC Th 2 Alternate Switching 11

Series Parallel Processing Topology Realization: Three-Phase System <Back-Up Mode> Th 2 AVR Non Interruption! V Th 1 Transition Period: High Gain AVR operation S-Con. P-Con. Inv. Th 2 V Th 1 S-Con. P-Con. Inv. 12

Series Parallel Processing Topology Realization: Single-Phase System How did we achieve without using the transformer? Easy to Compose the Series Converter with a Transformer. However, the miniaturization of the device of small capacity disturbed by the Transformer. Series Converter AVR? S-Con. S-Con. Furthermore we need DC Power Source. 13

Series Parallel Processing Topology Realization: Single-Phase System Parallel Converter Series Converter Series Converter Parallel Converter 14

Agenda 1. Background 2. Trend of Fuji UPS Technology 3. Series Parallel Processing Topology >Principal >Realization 4. New Products: 8000 Series ( Three-phase, Large Capacity ) 5. New Products: GX Series ( Single-phase, Small Capacity ) 6. Conclusion 15

New Products: 8000 Series Features 1. High Efficiency : 98% 2. Non Interruption 3. High reliability : (N+1) Redundant systems System / Circuit configurations Maintenance Bypass Circuit Through Circuit X Operation Waveforms ~ O X ac Switch O Loads Input Voltage UPS 8000D Series Converter O O Parallel Converter Battery Load Voltage 16

New Products: 8000 Series Specifications UPS Sy stem Dual processing method (Standby redundancy operation possible) Rated output capacity (kva) 100 150 200 250 300 400 500 600 750 1000 1500 2000 Switching time on serv ice interruption No short break AC input Number of phases Three-phase, three-wire Voltage 200 V +/-15% 415 V +/-15% Direct transmission input Frequency Power f actor Number of phases Voltage 50/60Hz (+/-1 to +/-5% selectable f or setting) 0.98 or more (At the rating) Three-phase, three-wire Same as the AC output v oltage AC output Voltage 200V or 415V, 3-phase Frequency Same as the input, except f or +/-0.01% when operated on battery. Load power f actor 0.8 (lag) to 1.0 (Rated at 1.0). Voltage accuracy (When set) In AVR mode: +/-2% or less In ECO mode: +/-5% or less (Selectable f or setting) Transient v oltage f luctuation +/-5% or less (Load 0 <=> 100%) Voltage waveform distortion factor Ov erload capacity 5% or less In normal condition: 125% for 10 minutes, 200% for one minute, 1000% for one cycle. During serv ice interruption: 150% f or one minute. 17

New Products: 8000 Series Example of Parallel Operation System Maintenance Bypass Circuit Maintenance Bypass Circuit Direct Transmission S-Con. P-Con. No 1 UPS Battery Input No 2 UPS Output No 3 UPS Max 8-Parallel / Redundancy 18

New Products: 8000 Series Example of Parallel Operation Waveforms Breakdown Mode Out-Put Voltage No 1 MC3 No 2 No 3 Loads Out-Put Current No 1 No 2 No 1 MC3 Breakdown No 3 Warning No 1 MC3 No 1-Fuse Blown No 1-MC3 Opened No 2 No 3 Loads 3-Parallel Operation 2-Parallel Operation 19

New Products: 8000 Series Comparison in Efficiency and Loss ( Example at 80kW ) Series Output ( kw ) Efficiency ( % ) Loss ( kw ) Power Consumption of Air-Conditioning Unit ( kw ) Conventional UPS 80 88 10.9 3.9 8000 Series 80 98 1.6 0.45 Comparison in Electric Charge ( Example at 100kVA ) Item Result Remarks Difference in UPS loss 9.3kW =10.9kW-1.6kW Difference in air-conditioning power consumption 3.45kW =3.9kW-0.45kW Electric power improved 12.75kW =9.3kW+3.45kW Annual electric energy reduced 111,690kWh =12.75kW x 24h x 365days Electric charge saved (Annual) 1.68 million yen / year Electricity rate of 15 yen/kwh Amount of CO 2 cut back 41.4t CO 2 emission rate of 0.371kg-amount of CO 2 /kwh The 8000 Series leads to a substantial cutback of running cost and reduction of CO 2 emissions. It can therefore be termed environment-friendly and suitable Green-IDC systems. *When operated continuously all year around under 100% load. 20

Agenda 1. Background 2. Trend of Fuji UPS Technology 3. Series Parallel Processing Topology >Principal >Realization 4. New Products: 8000 Series ( Three-phase, Large Capacity ) 5. New Products: GX Series ( Single-phase, Small Capacity ) 6. Conclusion 21

New Products: GX Series Features 1. High Efficiency : 96.7% ( 3000VA ) 2. Non Interruption GX200 GX100 System / Circuit configurations Operation Waveforms Input voltage Output voltage Change from 165V to 235V Change from 235V to165v 22

New Products: GX Series Specifications Series GX200 GX100 Input Capacity ( kva ) 0.7, 1.4, 3.0, 5.0, 7.5, 10 1, 1.5, 2.0, 3.0, 5.0, 7.5, 10 Phase Single-Phase / 2-Wire Single-Phase / 2-Wire Voltage ( V ) 200 ( +20%, -20% ) 220 / 230 ( +25%, -25% ) 240 ( +20%, -20% ) 85-138 ( Wide Range ) Output Phase Single-Phase / 2-Wire Single-Phase / 2-Wire Voltage ( V ) 200, 220 / 230, 240 ( +3%, -3% ) 100, 105, 110, 115, 120 ( +2%, -2% ) Selectable on Dip Switches Backup Time 5 - minutes 6 - minutes 23

New Products: GX Series Comparison in Efficiency and Loss Series Voltage ( % ) Efficiency ( % ) Loss ( W ) Conversion Loss ( W ) GX: 3000VA 75 92.8 187 139 100 96.7 83 36 125 94.9 129 81 Conventional J:3000VA 85 85.1 426 251 100 87.1 361 190 115 88.5 316 156 GX:700VA 75 90.4 47 35 100 96.6 16 4 125 92.8 35 23 Conventional J:1000VA 85 84.3 151 100 100 86.6 126 77 115 88.3 108 63 The GX Series is a high efficiency UPS. It means a substantial cutback of running cost and environment-friendly and suitable Server systems. 24

Agenda 1. Background 2. Trend of Fuji UPS Technology 3. Series Parallel Processing Topology >Principal >Realization 4. New Products: 8000 Series ( Three-phase, Large Capacity ) 5. New Products: GX Series ( Single-phase, Small Capacity ) 6. Conclusion 25

Conclusion Fuji Electric has worked on the development of high efficiency UPS since 2000. New Topology: Series Parallel Processing Topology 8000 Series: Large Capacity ( 100kVA - 2,000kVA ) High Efficiency and High Performance Suitable Green-IDC GX Series : Small Capacity ( 0.7kVA - 10kVA ) High Efficiency, For Server Fuji Electric Systems works on strategic development of new circuit topology and further, high efficiency UPS System aiming at the achievement of the Sustainable Society. 26

Thank You! Contact: okuma-yasuhiro@fesys.co.jp 27