ADDENDA ACKNOWLEDGMENT FORM

Similar documents
S Plumbing Fixtures

ADDENDA #1. Renovation and Construction of Boy s and Girl s Restroom Mountain View Alternative High School

SECTION PLUMBING FIXTURES, TRIM, AND SUPPORTS

Valves: 3303/3304 Retrofit: Air-Control To Master-Trol RETROFIT MASTER-TROL WATER MANAGEMENT SYSTEM

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS

PLUMBING FIXTURES DESIGN AND CONSTRUCTION STANDARD

PLUMBING FIXTURES, TRIM, AND SUPPORTS

Maintenance Guide. OPTIMA Components:

ETF-600 Sensor Operated Lavatory Faucet

Installation and Maintenance Instructions

Bid # Plumbing Supplies RESULTS

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

SECTION PLUMBING FIXTURES, TRIM, AND SUPPORTS

Sensor Activated Lavatory Faucet Installation, Operation & Service Instructions Model Numbers Tools & Materials Need Help?

A. This Section includes the following domestic water piping specialties:

SECTION PLUMBING FIXTURES, TRIM, AND SUPPORTS

Geberit Flushing Technologies Electronic and Manual Flush Valves

Notice is hereby given of the following changes and questions and answers to the above referenced Bid:

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5


A. This Section includes the following domestic water piping specialties:

WARDEN WA5 Cell Fixture Control System. Water only control, or Power/lighting/water control Warden high level control BMS interface

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

SIMPATICO SIMPATICO LARSEN SUPPLY CO., INC.

Sloan & Zurn Flush Valves

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

DIVISION 6: PLUMBING ELEMENTS AND FACILITIES

Lead-free Pneumatic Metering Valve Assemblies (Plastic Bodied) WILLOUGHBY Industries, Inc WEST 78TH STREET / INDIANAPOLIS, IN 46268

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

THE KEENEY MANUFACTURING COMPANY

.3 Section Waste Management and Disposal.

REPLACEMENT PARTS Quick Reference Guide

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Installation and Maintenance Instructions

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

Chapter 6. Plumbing Elements and Facilities

Segment Name: CAST IRON 22X18 SERVICE SINK

Sub - contractor Equip. $ UNIT PRICE TOTAL MAT. Unit $

A Product Line from Acorn Engineering Company PRODUCTS. Acorn Controls for bather safety and comfort SHOWERING & TEMPERING

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

D28 SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER. D28 B D28 E D28 Dual Power B D28 Dual Power E D28 Box D28 Box E

AIR SHOWER & TUB REP

CARRIER SYSTEMS. Fitting Type. Connection Type (N)No-Hub (H)Hub and Spigot APPLICATION INDEX PRODUCT COMPLIANCE SPECIFY A WATER CLOSET SYSTEM

SECTION VARIABLE FREQUENCY DRIVE UNITS

Electronic Faucet - 591T Series

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Z x 17 Countertop Lavatory

Builders Faucets. c. Roman Tub Faucets i. Trim ii. Rough In iii. Roman Tub Filler Valves Only

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

Aquaflush. Z6000 Series Aquaflush Exposed Flushometer Installation, Operation, Maintenance, and Parts Manual Z6000 Z6003

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

WC FLUsHiNG. WC Flushvalves offer an average of 30% water saving...

VENDORS OPENING DATE: AUGUST 28, 2012 INTERLINE BRANDS, INC.D/B/A SEXAUER NOLAND COMPANY APPLE SPECIALTIES INC. ENTERPRISES, INC.

LIGATURE RESISTANT SENSOR FAUCET

MrSteam ANSI. Residential Steambath Generator Systems Installation,Operation & Maintenance Manual MODELS: MS-65 MS-90 MS-150 MS-225 MS-300 MS-400

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115

Valves: EVS Series MASTER-TROL WATER MANAGEMENT SYSTEM

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

SHOWERING & TEMPERING PRODUCTS. Acorn Controls for bather safety and comfort

ADDENDUM No. 1. BID No /15 Chevrolet Silverado Work Trucks

OPERATION & MAINTENANCE MANUAL HB-8000C Series Flush Valve (includes HB8RFKC)

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Users Manual Certified Series Direct Drive Pump 1-7 LPM

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

BID FOR A ONE (1) ONE-TON AND A HALF (5500 SERIES) CREWCAB TRUCK WITH DUMP BED. BID OPENING February 15, 2017 AT 10:00 A.M.

BID FOR ONE (1) 1 TON CREW CAB TRUCK WITH SERVICE BODY OPENING APRIL 11, 2019 AT 10:00 A.M.

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

ADDENDUM NO. 2 DATE: March 3, BID TITLE: Replacement of Two (2) Twenty Ton Overhead Crane Hoists, Trolley Packages, and Associated Equipment

T&S BRASS AND BRONZE WORKS, INC.

Plumbing Parts and Supplies Part I

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

EZ FILL FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE

Hops Fixture/ Flow Rate Schedule. Fixture Model# Performan #of Total Toilets All Toilets Kelston K Average 1.28

Microprocessor Controlled Dental Vacuum System Installation Manual

AquaSense AV ZER Series

34-SDMS-02 SPECIFICATIONS FOR

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

ChapterS ACCESSIBLE BUILDINGS & FACILITIES Code References 1.) Plumbing fixtures conforming to "Accessible Buildings & Facilities"

CAT PUMPS (7.5 HP) Pump Stations DU PS1901C-PG & DU PS1901CPG2 DU PS1903C-PG & DU PS1903CPG2

Optima ETF-600/ETF-610

1 - S-2251 Showerhead 6 - S-2288 Showerhead AP - Anchor Plate (S-2280 Showerhead Only)

HALLMARK INDUSTRIES INC


Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2


SLOAN ZURN DELANY INLET SIZE FLUSH CONNECTION ROUGH-IN

Transcription:

ADDENDA ACKNOWLEDGMENT FORM I T B ADDENDUM Department of Corrections 2601 Blair Stone Road Tallahassee, Florida 32399-2500 ITB/BID NO: ITB/BID TITLE: 10-SANTA ROSA-8232 Plumbing Fixtures OPENING DATE: 12/21/10 ADDENDUM NO: 3 DATE: 12/14 /10 PLEASE BE ADVISED THAT THE FOLLOWING CHANGES ARE APPLICABLE TO THE ORIGINAL SPECIFICATIONS OF THE ABOVE-REFERENCED ITB: Please add Attachment 2, Specifications to the above solicitation. THIS ADDENDUM NOW BECOMES A PART OF THE ORIGINAL ITB. THE ADDENDUM ACKNOWLEDGMENT FORM SHALL BE SIGNED BY AN AUTHORIZED COMPANY REPRESENTATIVE, DATED AND RETURNED, AS INSTRUCTED IN SECTION 5, BID SUBMISSION REQUIREMENTS, WITH THE BID. FAILURE TO DO SO MAY SUBJECT THE BIDDER/CONTRACTOR TO DISQUALIFICATION. BIDDER: BY: ADDRESS: PHONE: CITY, STATE DATE: AUTHORIZED SIGNATURE

Page 1 of 15 ATTACHMENT 2 - SPECIFICATIONS SECTION 22 00 02 PLUMBING 1.01 PLUMBING FIXTURES A. Acceptable Manufacturers The fixtures listed are from various vendors and are not intended to limit competition. See Section 3.4, Trade Names on page 7. B. Fixture Trim Exposed metal parts shall be of heavy weight polished brass, heavily chrome plated, of best quality as regularly furnished by the plumbing fixture manufacturer. Provide stop valve and supply to all fixtures and equipment. 1.02 FIXTURE SCHEDULE A. Bath Tubs: 1. BT-1 BATHTUB (Institutional) TUB: 2. BT-2 (BOQ) TUB: TUB SHOWER VALVE: WASTE & OVERFLOW: 3. BT-3 BATHTUB: TUB; B. Lavatories: 1. L-1: 2. L-2: TUB SHOWER VALVE: WASTE OVERFLOW KOHLER K-840. (SEE ARHITECTURAL DRAWINGS FOR TUB ENCLOSURE) SPEAKMAN VS-1980-AFSS-M KOHLER K-7161-AF KOHLER K-1585/1586 SYMMONS S-96-2-X-VP McGUIRE 1221TL KOHLER K-505/506 SYMMONS S-96-2-X McGUIRE 1221TL KOHLER K-2849 SYMMONS S-61 KOHLER K-2849 SYMMONS S-61 TRAP WRAP: McGUIRE 155WC BOCAR C500RHS WHITE

Page 2 of 15 3. L-3: KOHLER K-2867 SYMMONS S-61 CARRIER: J.R. SMITH 0752-M30 4. L-4: KOHLER K-2867 SYMMONS S-61 TRAP: McQUIRE B-8872 McGUIRE 155WC TRAP WRAP: BOCAR C500RHS WHITE CARRIER: J.R. SMITH 0752-M30 5. L-5: KOHLER K-2849 SYMMONS S-60-H 6. L-6: KOHLER K-2849 SYMMONS S-60-H TRAP: McQUIRE B-8872 McGUIRE 155WC TRAP WRAP: BOCAR C500RHS WHITE 7. L-7: KOHLER K-2867 SYMMONS S-20-W-FR CARRIER: J.R. SMITH 0752-M30

Page 3 of 15 8. L-8: KOHLER K-2867 SYMMONS S-60-H McGUIRE 155WC TRAP WRAP: BOCAR C500RHS WHITE CARRIER: J.R. SMITH 0752-M30 9. L-9: KOHLER K-2905-4 SYMMONS S-60-H 10. L-10: KOHLER K-2905-4 SYMMONS S-60-H TRAP WRAP: BOCAR C500RHS WHITE 11. L-11: KOHLER K-2005 SYMMONS S-20-W-FR CARRIER: J.R. SMITH 700-M31 OR 700 12. L-12: KOHLER K-2905-4 SYMMONS S-20-2-FR TRAP: McGUIRE 8872 13. L-13: Not Used.

Page 4 of 15 14. L-14: KOHLER K-2867 SYMMONS S-60H McGUIRE 2165 CCLK CARRIER: J.R. SMITH 0752-M30 15. L- 15: HANDICAP KOHLER K-2867 SYMMONS S-60H SUPPLY; GRAD TRAP WRAP: BOCAR C500RHS WHITE CARRIER: J.R. SMITH 0752-M30 C. Water Closets: 1. WC-1: KOHLER K-4350 SEAT: BEMIS 1955 SS/C FLUSH VALVE: SEE SECTION 22 42 40 2. WC-2: KOHLER K-4368 SEAT: BEMIS 1955 SS/C FLUSH VALVE: SEE SECTION 22 42 40 3. WC-3: KOHLER K-4330 SEAT: BEMIS 1955 SS/C FLUSH VALVE: SEE SECTION 22 42 40 CARRIER: J.R.SMITH 115-L-Y-M50-M12 4. WC-4: KOHLER K-3422 SEAT: BEMIS 1950-SS/C McGUIRE 2166CCLK 5. WC-5: KOHLER K-3427 SEAT: BEMIS 1950-SS/C McGUIRE 2166CCLK

Page 5 of 15 6. WC-6: KOHLER K-4330-L SEAT: BEMIS 1955 SS/C FLUSH VALVE: SEE SECTION 22 42 40 CARRIER: J.R.SMITH 115-L-Y-M50-M12 D. Urinals: 1. U-1: KOHLER K-5016-ET FLUSH VALVE: SEE SECTION 22 42 40 2. U-2: KOHLER K-5016-ET FLUSH VALVE: SEE SECTION 22 42 40 MOUNT LIP 17 ABOVE FINISHED FLOOR 3. U-3: KOHLER K-5016-ET FLUSH VALVE: SEE SECTION 15151 CARRIER: J.R.SMITH 0636 E. Sinks: 1. S-1: ELKAY D-11719 (3 HOLE DRILLING) T&S BRASS B-0865-VP-04 TRAP: McGUIRE B-8912 McGUIRE 151A 2. S-2: ELKAY D-11719 (3 HOLE DRILLING) T&S BRASS B-0305LN/VP120X/010204-40 TRAP: McGUIRE B-8912 MGUIRE 2165CCLK McGUIRE 151A

Page 6 of 15 3. S-3: ELKAY D23319 ( 3 HOLE DRILLING) T&S BRASS B-0865-04-VP TRAP: McGUIRE B-8912 (2) McGUIRE 151A WASTE: McGUIRE 11C16G17 4. S-4: JUST A-18665 T&S BRASS B-0669-POL-VP TRAP: McGUIRE B-8912 JUST J-35-GS-STP 5. S-5: KOHLER K-6714 T&S BRASS B-0669-POL -VP TRAP: KOHLER K-6672 6. S-6: ELKAY D-11719 T&S BRASS B-2851/B-0199-06 TRAP: J.R. SMITH 8750 McGUIRE 151A 7. S-7: ELKAY D-23319 (3 HOLE DRILLING) T&S BRASS B-2955/B-0199-06 TRAP: McGUIRE B-8912 (2)McGUIRE 151A WASTE: McGUIRE 11C16G17 8. S-8: FURNISHED WITH FAUCET DENTAL EQUIPMENT TRAP: McGUIRE B-8912

Page 7 of 15 9. S-9 SINK: ELKAY D-23322 (3 HOLE DRILLING) T&S BRASS B-2855/B-0199-06 PIPE BOTH SIDES OF FAUCET WITH COLD WATER. TRAP: McGUIRE B-8912 (2) McGUIRE 151A WASTE: McGUIRE 11C16G17 10. S-10: KOHLER K-6718 T&S BRASS B-0669-POL-VP TRAP: KOHLER K-6673 11. S-11: FIAT FL-1 FIAT A-1 TRAP: McGUIRE B-8912 12. S-12: ELKAY D-23319 SYMMONS S-23-2 STRAINER: ELKAY LK-35 WASTE: McGUIRE 11C16G17 TRAP: McGUIRE 8912 F. Mop Sinks: 1. MS-1: RECEPTOR: HOSE & BRACKET: MOP HANGER: BUMPER GUARD: DRAIN CONNECTOR: FIAT MSB-2424 T&S BRASS B-0650-BSTP-VP FIAT 832-AA FIAT 889-CC FIAT E-77-AA FIAT QDC-3XH

Page 8 of 15 2. MS-2: SAME AS MS-1 EXCEPT PIPE BOTH SIDES OF FAUCET WITH COLD WATER 3. MS-3: RECEPTOR: Field Constructed, See Architectural Drawings T&S BRASS B-0650-BSTP-VP HOSE & BRACKET: FIAT 832-AA MOP HANGER: FIAT 889-CC BUMPER GUARD: FIAT E-77-AA J.R. smith model #2005LXH03-U G. Electric Water Coolers: 1. EWC-1: COOLER: SUNROC NWCA-8 2. EWC-2: COOLER: SUNROC NWCA-8 MODIFIED. PROVIDE DRILLING FOR BUT LESS GLASS FILLER HOT WATER ZURN Z-825A WALL SUPPORT BRACKET: T&S B-0109-01 WITH VANDAL PROOF SCREWS 3. EWC-3 (Handicap, Chill Only) COOLER: ELKAY EZSTL8C (right unit rough-in) ELKAY EZSTLR8C (left unit rough-in) 4. EWC-4WATER COOLER: (Handicap, Chill & Hot) COOLER: ELKAY EZSTL8C (right unit rough-in) ELKAY EZSTLR8C (left unit rough-in) MODIFIED. PROVIDE DRILLING FOR BUT LESS GLASS FILLER. HOT WATER ZURN Z-825A WALL SUPPORT BRACKET: T&S B-0109-01 WITH VANDAL PROOF SCREWS

Page 9 of 15 H. Drinking Fountains: 1. DF-1 DRINKING FOUNTAIN: (Exterior, CW) FOUNTAIN: 1 ELKAY EDFP217RAC WITH BOTTOM COVER PLATE AND MOUNTING PLATE. TRAP: 1 McGUIRE B-8872 I. Showers: 1. SHR-1: SHOWER VALVE: 2. SHR-2: SHOWER VALVE: SYMMONS S-96-1-X PRESSURE BALANCED WITH INTEGRAL STOPS, SHOWER HEAD AND ARM SYMMONS S-96-500-B30-LV-X-VP PRESSURE BALANCED WITH INTERGRAL STOPS, SHOWER HEAD AND ARM, HAND HELD END OF SECTION

Page 10 of 15 SECTION 22 09 00 INSTRUMENTATION AND CONTROL FOR PLUMBING PART TWO - GENERAL 1.01 DESCRIPTION A. The General Conditions of the specifications are applicable in full hereto. B. Include all equipment and materials required for a complete electronic water control system. 1.02 WORK INCLUDED A. Work will include, but is not limited to the following: 1. Force activated sensors. 2. 4 I/O port controllers. 3. Manifold hot and cold water solenoid valves. 4. Color coded control wire and connectors. 5. Water supply tubing from solenoid valves to fixture filler bubbler. 6. 16 gauge stainless steel mounting plate with controllers, manifold solenoids and transformer pre-mounted. 7. 24VAC transformer with cord and 20 amp plug. 8. Label all Panels: Secure housing unit will be labeled with the corresponding room number. The Open Bay Dorm panels will be labeled for each fixture it controls. B. Connection to fixtures specified and or indicated shall be served with electronic water controls. Line voltage power wiring shall be furnished under work of Section 16000. C. Maximum distance from fixture to control panel is 50 feet. D. Furnish repair parts as specified. E. Start-up and check out of control system. F. Lavatory filler bubblers and solenoid operated flush valves will be furnished. 1.03 GUARANTEE AND SERVICE A. The contractor shall guarantee all control panel parts furnished for a period of one (1) year from receipt of purchase order against defects due to faulty materials or workmanship. Such defects shall be corrected promptly after notification by Owner and at Contractor s expense with no additional cost to the Department. B. The Contractor shall furnish, without charge, any reasonable service in making minor adjustments to equipment furnished. The service shall not include the replacement of parts damaged by maliciousness or vandalism after acceptance by Department. C. The contractor shall put all items furnished under this section into operation and instruct the Department s Maintenance Personnel in all points requiring service or maintenance.

Page 11 of 15 D. Furnish two (2) bound copies of maintenance instructions, operating instructions and parts list. 1.04 SUBMITTAL DATA A. Within 25 days after award of contract, submit for approval a complete schedule of equipment proposed to be furnished. Include the catalog data. 1.05 REPAIR PARTS A. Furnish the following replacement parts to the Department prior to final acceptance. 1. Ten (10) stainless steel force activated sensor assemblies with 40 Lead, modular plug, nut and lock-washer. 2. Five (5) 24 VAC transformers. Type TRB-0233. 3. Thirty (30) solenoid valves. 4. Fifteen (15) CNC 0004 controllers 5. Ten (10) CNC-0004 (HCFF) (5) CNC-0004 (SSSS) 6. Twenty (20) FVK-7001-X Solenoid operated flush valves. 7. Three (3) CNC- 0008 (FFFFFFFF) controllers. 8. Four (4) CNC0004 (HCHC) controllers. 9. One (1) force activated sensor assembly (Tester). PART TWO - PRODUCTS 2.01 APPROVED MANUFACTURERS A. ICON-SYSTEMS 1724 W. Broadway Oviedo, Florida 32765 (407) 365-6241 or SLOAN B. The successful supplier shall provide a control system manufactured by a firm specializing in the production of Prison Electronic Control Systems with a minimum of five (5) years successful experience in the specified field and provide a minimum reference list containing five (5) of the manufacturer s successfully installed and operational facilities. C. The successful bidder shall provide a (1) year full warranty of all components provided. This shall include, but not be limited to, any rebuild parts and kits for any components, and/or new sensors, valves, control boards, and solenoids as required. This warranty shall not include damages or failures to abuse, negligence or misuse. 2.02 CONTROL PANEL CP-1 I-CON HA-7344-1-CPS COMBIE A. I-Con Model CNC 0004 non-communicating control box shall be self-contained housing with four (4) input/output ports. Each set of input/output have a standard predetermined designation (i.e. Port #1 shall control the hot water lavatory spout. Port #2 shall control the cold water to the lavatory spout; Port #3 shall control the flush valve and Port #4 shall be a Spare flush valve port). The input port is sent a low voltage electrical impulse from the pressure- activated sensor mounted in the fixture. The impulse is immediately transferred to the output port and the output function is then controlled by the preprogrammed microprocessor. The output port transfers the electrical signal to the solenoid valve, which results in water flows to lavatory filler bubblers or flush valve solenoid for a preprogrammed amount of time.

Page 12 of 15 The control board shall have the ability to be upgraded to a communication controller by the use of an add-on module and using the existing 110V power line as the network link with no additional communication wires required. B. VLM-7104 Lavatory Manifold shall include eight (8) solenoid valve operators to provide hot and cold water for four (4) lavatory units. Lavatory manifold valves shall be industrial quality and shall include solenoid valves without diaphragms. Valves that include diaphragms are acceptable. Manifold shall include ½ IPS hot and cold water inlets with 20 braided stainless steel hose connectors, stainless steel strainers, check stops, 0.5 GPM flow control and eight (8) soft close antihammer solenoid operators. Each solenoid valve operator shall be furnished with a minimum of twenty (20) feet of telephone cable with modular plug type connector and 3/8 water tubing. Each lavatory solenoid shall include a manual override feature to enable to turn on water to filler bubblers by bypassing the electronic circuitry in the event of power loss or during troubleshooting. The solenoid coil and plunger shall be interchangeable with solenoid coil plunger of shower valve. C. Flush valves are specified in another section of specifications. Electronics manufacturer shall provide all necessary fittings to connect supplied flush valves to the electronic system. D. Icon SEF1489 Touch Sensor Button assemblies shall have stainless steel housing and shall be pressure activated with no mechanical moving components and completely waterproof. The sensor shall operate on a strain gauge type principle and the sensor adjustment shall be self-calibrating. Sensor assembly shall include six (6) feet of telephone type cable and modular plug type connector. Sensors shall be pre-wired prior to shipment. Furnish a CDA1489 core drill assembly for each SS-2 fixture. E. Touch Sensor Buttons must fit fixture manufacturer s D punching. F. Controllers shall be factory programmed in accordance with the following: 1. Lavatory: a. Hot water twenty (20) second run-time b. Cold water ten (10) second run-time 2. Flush Valve: Pressure senor Solenoid is activated. Flush cycle occurs immediately. If procedure is repeated within five (5) minutes then the flush valve is disabled for fifteen (15) minutes. Repeated pressure sensor operation has no effect on the disabled lock out time. Lock-out time shall be field adjustable for 0-60 minute lockout. G. Transformer shall be 110 VAC, 60 Hz primary, 24 VAC, 40 VA, Class II, overload protected complete with six (6) feet of #12-3 conductor SJO cord, and NEMA 5-20 plug. Protected by ½ AMP SBT fuse on the primary side and a 2 AMP fuse on secondary. 2.03 CONTROL PANEL CP-2 I-CON HA -7344-1-SPS SHOWER PANEL ASSEMBLY A. I-Con Model CNC 0004 non-communicating control box shall be self-contained housing with one (2) input/output ports. Each set of input/output ports have a standard predetermined designation (i.e. Port #1 shall control the hot water. Port #2 shall control the cold water. The input port is sent a low voltage electrical impulse from the pressure- activated sensor mounted in the fixture. The impulse is immediately transferred to the output port and the output function is the controlled by the preprogrammed microprocessor. The output port transfers the electrical signal to the solenoid valve, which results in water flows to the showerhead for a preprogrammed amount of time. The control board shall have the ability to be upgraded to a communication controller by the use of an add-on module and using the existing 110V power line as the network link with no additional communication wires required. B. The control box shall contain lights indicating the functions of operation. Amber LED shall show power to the control box, green LED to each input port when the pressure sensor is activated and at the output port when the solenoid operator is activated. The output port shall remain illuminated for the duration of the preprogrammed run time. C. A pair of red LEDs shall indicate when block times are in effect when a red LED is illuminated, the shower valve run time has expired, and the program is preventing the shower valve solenoids from being activated. The shower valve shall be prevented from use as long as the fixture s associated red LED is illuminated.

Page 13 of 15 D. I-Con VLM-7104 Shower manifold shall include (8) eight solenoid operators to provide hot and cold water for (4) four shower heads. Shower manifold valves shall be industrial quality and shall include solenoid valves without diaphragms. Any valve that includes diaphragms is not acceptable. Manifold shall include ½ IPS hot and cold water inlets with 8 braided stainless steel hose connectors, stainless steel strainers, check stops, 2.5 GPM flow control, and eight (8) soft close anti-hammer solenoid operators. Each solenoid valve operator shall be furnished with a minimum of twenty (20) feet of telephone cable with modular plug type connector and 3/8 water tubing. Each lavatory solenoid shall include a manual override feature to enable to turn on water to shower head by bypassing the electronic circuitry in the event of power loss or during troubleshooting. The solenoid coil and plunger shall be interchangeable with solenoid coil plunger of lavatory valve. E. Icon SEF1489 Touch Sensor Button assemblies shall have stainless steel housing and shall be pressure activated with no mechanical moving components and completely waterproof. The sensor shall operate on a strain gauge type principle and the sensor adjustment shall be self-calibrating. Sensor assembly shall include six (6) feet of telephone type cable and modular plug type connector. Sensors shall be pre-wired prior to shipment. F. Controllers shall be factory programmed in accordance with the following. 1. Shower: Hot and cold water five (5) minute run-time. Field adjustable lock out reinitiates delay following shut-off of zero (0) to fifteen (15) minutes. Reinitiated delay shall lock out both hot and cold water. G. Transformer shall be 110 VAC, 60 Hz primary, 24 VAC, 40 VA, Class II, overload protected complete with six (6) feet of #12-3 conductor, SJO cord and NEMA 5-20 plug. Protected by ½ AMP SBT fuse on the primary side and a 2 AMP fuse on secondary. 2.04 CONTROL PANEL CP-3 I-Con HA -7344-2-SPS - Shower Panel Assembly Medical Isolation Cells A. I-Con Model CNC 0004 non-communicating control box shall be self-contained housing with one (4) input/output ports. Each set of input/output ports have a standard predetermined designation (i.e. Port #1 shall control the hot water. Port #2 shall control the cold water. Port #3 shall control the hot water. Port #4 shall control the cold water. The input port is sent a low voltage electrical impulse from the pressure- activated sensor mounted in the fixture. The impulse is immediately transferred to the output port and the output function is the controlled by the preprogrammed microprocessor. The output port transfers the electrical signal to the solenoid valve, which results in water flows to the showerhead for a preprogrammed amount of time. The control board shall have the ability to be upgraded to a communication controller by the use of an add-on module and using the existing 110V power line as the network link with no additional communication wires required. B. The control box shall contain lights indicating the functions of operation. Amber LED shall show power to the control box, green LED at each input port when the pressure sensor is activated and at the output port when the solenoid operator is activated. The output port shall remain illuminated for the duration of the preprogrammed run time. C. A pair of red LEDs shall indicate when block times are in effect. When a red LED is illuminated, the shower valve run time has expired, and the program is preventing the shower valve solenoids from being activated. The shower valve shall be prevented from use as long as the fixture s associated red LED is illuminated. D. I-Con VLM-7102 Shower manifold shall include (4) four solenoid operators to provide hot and cold water for (2) two shower heads. Shower manifold valves shall be industrial quality and shall include solenoid valves without diaphragms. Any valve that includes diaphragms is acceptable. Manifold shall include ½ IPS hot and cold water inlets with 8 braided stainless steel hose connectors, stainless steel strainers, check stops, 2.5 GPM flow control and eight (4) soft close anti hammer solenoid operators. Each solenoid valve operator shall be furnished with a minimum of twenty (20) feet of telephone cable with modular plug type connector and 3/8 water tubing. Each shower solenoid shall include a manual override feature to enable to turn on water to shower head by bypassing the electronic circuitry in the event of power loss or during troubleshooting. The solenoid coil and plunger shall be interchangeable with solenoid coil plunger of shower valve.

Page14 of 15 E. Icon SEF1489 Touch Sensor Button assemblies shall have stainless steel housing and shall be pressure activated with no mechanical moving components and completely waterproof. The sensor shall operate on a strain gage type principle and the sensor adjustment shall be self-calibrating. Sensor assembly shall include sixty (60) feet of telephone type cable and modular plug type connector. Sensors shall be pre-wired prior to shipment. F. Controllers shall be factory programmed in accordance with the following: 1. Shower Hot and cold water three (3) minute run-time. Field adjustable lock-out reinitiates delay following shut-off of zero (0) to fifteen (15) minutes. Reinitiates delay shall lock-out both hot and cold water. G. Transformer shall be 110 VAC, 60 Hz primary, 24 VAC, 40 VA, Class II, overload protected complete with six (6) feet of #12-3 conductor SJO cord, and NEMA 5-20 plug. Protected by ½ AMP SBT fuse on the primary side and a 2 AMP fuse on secondary. 2.05 CONTROL PANEL CP4 I-Con HA -7344-1-LPS (Lavatory Open Bay Dorms) A. I-Con Model CNC 0004 non-communicating control box shall be self-contained housing with four (4) input/output ports. Each set of input/output ports have a standard predetermined designation (i.e. Port #1 shall control the hot water. Port #2 shall control the cold water. The input port is sent a low voltage electrical impulse from the pressure- activated sensor mounted in the fixture. The impulse is immediately transferred to the output port and the output function is the controlled by the preprogrammed microprocessor. The output port transfers the electrical signal to the solenoid valve, which results in water flows to the lavatory for a preprogrammed amount of time. The control board shall have the ability to be upgraded to a communication controller by the use of an add-on module and using the existing 110V power line as the network link with no additional communication wires required. B. The control box shall contain lights indicating the functions of operation. Amber LED to show power to the control box, green LED at each input port when the pressure sensor is activated and at the output port when the solenoid operator is activated. The output port shall remain illuminated for the duration of the preprogrammed run time. C. A pair of red LEDs shall indicate when block times are in effect when a red LED is illuminated, the lavatory valve run time has expired, and the program is preventing the lavatory valve solenoids from being activated. The lavatory valve shall be prevented from use as long as the fixture s associated red LED is illuminated. D. I-Con VLM-7104 Lavatory manifold shall include (8) eight solenoid operators to provide hot and cold water for (4) four lavatories. Lavatory manifold valves shall be industrial quality and shall include solenoid valves without diaphragms. Any valve that includes diaphragms is not acceptable. Manifold shall include ½ IPS hot and cold water inlets with 8 braided stainless steel hose connectors, stainless steel strainers, check stops, 0.5 GPM flow control and eight (8) soft close anti-hammer solenoid operators. Each solenoid valve operator shall be furnished with a minimum of twenty (20) feet of telephone cable with modular plug type connector and 3/8 water tubing. Each lavatory solenoid shall include a manual override feature to enable to turn on water to shower head by bypassing the electronic circuitry in the event of power loss or during troubleshooting. The solenoid coil and plunger shall be interchangeable with solenoid coil plungers on the shower valves. E. Icon SEF1489 Touch Sensor Button assemblies shall have stainless steel housing and shall be pressure activated with no mechanical moving components and completely waterproof. The sensor shall operate on a strain gage type principle and the sensor adjustment shall be self-calibrating. Sensor assembly shall include twenty (20) feet of telephone type cable and modular plug type connector. Sensors shall be pre-wired prior to shipment. F. Controllers shall be factory programmed in accordance with the following. 1. Lavatory Hot water twenty (20) second run time, cold water ten (10) second run time. Field adjustable lock out reinitiates delay following shut-off of zero (0) to fifteen (15) minutes. Reinitiated delay shall lock out both hot and cold water. G. Transformer shall be 110 VAC, 60 Hz primary, 24 VAC, 40 VA, Class II, overload protected complete with six (6) feet of #12-3 conductor SJO cord, and NEMA 5-20 plug. Protected by ½ AMP SBT fuse on the primary side and a 2 AMP fuse on secondary.

Page 15 of 15 2.06 CONTROL PANEL CP-5 HA-7344-2-CPS MEDICAL ISOLATION CELLS A. I-Con Model CNC 0004 non-communicating control box shall be self-contained housing with four (4) input/output ports. Each set of input/output ports have a standard predetermined designation (i.e. Port #1 shall control the hot water lavatory spout. Port #2 shall control the cold water to the lavatory spout. Port #3 shall control the flush valve at the toilet and port #4 shall control the flush valve from a remote location in the adjacent vestibule. The input port is sent a low voltage electrical impulse from the pressure- activated sensor mounted in the fixture. The impulse is immediately transferred to the output port and the output function is then controlled by the preprogrammed microprocessor. The output port transfers the electrical signal to the solenoid valve, which results in water flows to lavatory filler bubblers or flush valve solenoid for a preprogrammed amount of time. The control board shall have the ability to be upgraded to a communication controller by the use of an add-on module and using the existing 110V power line as the network link with no additional communication wires required. B. The control box shall contain lights indicating the functions of operation. Amber LED to show power to the control box, green LED at each input port when the pressure sensor is activated and at the output port when the solenoid operator is activated. The output port shall remain illuminated for the duration of the preprogrammed run time. C. A pair of red LEDs shall indicate when block times are in effect when a red LED is illuminated, the flush valve has been used too often in a given period of time, and the program is preventing the flush valve solenoid from being activated. The flush valve shall be prevented from use as long as the fixture s associated red LED is illuminated. D. VLM-7101 Lavatory Manifold shall include two (2) solenoid valve operators to provide hot and cold water for one (1) lavatory unit. Lavatory manifold valves shall be industrial quality and shall include solenoid valves without diaphragms. Any valve that includes diaphragms is acceptable. Manifold shall include ½ IPS hot and cold water inlets with 20 braided stainless steel hose connectors, stainless steel strainers, check stops, 0.5 GPM flow control and two (2) soft close anti-hammer solenoid operators. Each solenoid valve operator shall be furnished with a minimum of twenty (20) feet of telephone cable with modular plug type connector and 3/8 water tubing. Each lavatory solenoid shall include a manual override feature to enable to turn on water to filler bubblers by bypassing the electronic circuitry in the event of power loss or during troubleshooting. The solenoid coil and plunger shall be interchangeable with solenoid coil plunger of shower valve. E. Flush valves: I-Con FVK-7001-X come standard with 1 ball valve, vacuum breaker, flush tubing, and a 20 lead. F. Icon SEF1489 Touch Sensor Button assemblies shall have stainless steel housing and shall be pressure activated with no mechanical moving components and completely waterproof. The sensor shall operate on a strain gage type principle and the sensor adjustment shall be self-calibrating. Sensor assembly shall include six (20) feet of telephone type cable and modular plug type connector. Sensors shall be pre-wired prior to shipment. Furnish a CDA1489-8 core drill assembly for each SS-14&15 fixture. G. Touch Sensor Buttons must fit fixture manufacturer s D punching. H. Controllers shall be factory programmed in accordance with the following. 1. Lavatory: Hot water twenty (20) second run-time. Cold water ten (10) second run-time 2. Flush valve: Pressure sensor is activated. Flush cycle occurs immediately. If procedure is repeated within five (5) minutes then the flush valve is disabled for fifteen (15) minutes. Repeated pressure sensor operation has no effect on the disabled lock out time. Lock-out time shall be field adjustable for 0-60 minute lockout. I. Transformer shall be 110 VAC, 60 Hz primary, 24 VAC, 40 VA, Class II, overload protected complete with six (6) feet of #12-3 conductor SJO cord and NEMA 5-20 plug, protected by-1/2 AMP SBT fuse on the primary side and a 2 AMP fuse on the secondary side.