Series 751 FireLock European Alarm Check Valve Stations

Similar documents
Series 756 FireLock Dry System Check Valve

Series 758 FireLock Actuated System Valve

Series 769 FireLock NXT Deluge Valve

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

Style 99 Roust-A-Bout Couplings

Vic-Strainer WARNING. System No. Submitted By Spec Sect Para Location Date Approved Date IPS CARBON STEEL PIPE - GROOVED ACCESSORIES SERIES 730

FireLock NXT Actuated Valve with Preaction Trim. System No. Submitted By Spec Sect Para Location Date Approved Date

Series 706 Butterfly Valves (300 PSI/2065 kpa)

Series W706 AGS Butterfly Valves (300 PSI/2065 kpa)

B NPT. Dimensions Inches/millimeters

Series 709 Butterfly Valves (175 psi/1270 kpa)

Series W709 AGS Butterfly Valves (175 psi/1270 kpa)

Pressfit System for Carbon Steel Pipe

Grooved Piping System for Fire Protection Services

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance

Easy Riser swing check valve Models E-1 & F-1

TECHNICAL DATA OBSOLETE

Grooved Piping System for Fire Protection Services

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

I-NXT.RBKIT 5-Year Rebuild Kit Instructions for FireLock NXT Valves

FIRE PROTECTION EQUIPMENT 2017 DATA SHEETS BSP FIRE RESERVES THE RIGHT TO ALTER INFORMATION CONTAINED IN THIS CATALOGUE AT ANY TIME.

Size Inches UL ULC FM. Pipe Sch.

Victaulic Specification Power Industry

FIRE PROTECTION PRODUCTS

VICTAULIC Shouldered Solutions

Stainless Steel Pipe System. System No. Submitted By Spec Sect Para Location Date Approved Date TEMPERATURE ( F/ C)

REQUEST PUBLICATION 18.11

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Victaulic Fittings, Couplings, Valves & Sprinkler Heads for the Fire Sprinkler Market Keeping the art of distribution simple

PARTS ORDERING INFORMATION

BS 5163 Resilient Wedge Gate Valve

Sludge Dewatering and Odor Control at Plant 1 CONFORMED

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA. Q= C v P S

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TECHNICAL DATA 1-1/2 (dn40)

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

DELUGE VALVE DATA SHEET

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Worldwide Contacts.

Fire Protection Price List

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Fire Protection Price List. Piping. Systems. Solutions A FP.

11.02 Mechanical-T Bolted Branch Outlets

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

DV-5A Automatic Water Control Valve Remote-Resetting Deluge Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

AGCX Bulletin 519 C/Alfoz de Bricia nº4 P.l. Villalonquéjar Burgos (Spain) Tlfno: PAG 1 de 50

HYDRAULIC CONTROL VALVES

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Technical Data. UL Listing is based on the following criteria:

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

From the world s leader in mechanical piping systems... The complete system for stainless steel piping.

Q= C v P S. Flow control valve Model j-2 Halar coated

Victaulic Suction Vibration Isolation Pump Drop Series 337 Korea Only

Cast Iron Valves. Product Information. It s all at Albion

Section 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings

GRINNELL Model B303 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Model DDX Deluge Valve 8 (200mm) Features

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Typical Specifications Grooved Piping Method

Hot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

Grinnell Grooved Fire Protection Products Grooved Fittings

MODEL RCW DELUGE SYSTEM ELECTRIC, WET PILOT, AND DRY PILOT ACTUATION

Technical Data. Sizes 2 12 Inch (DN50 DN300)

Section L Wet Pipe Systems

SHORTER. LIGHTER. MORE VERSATILE. 1 VALVE 10 TRIM CONFIGURATIONS 4" AND 6" MODEL RCW WATER CONTROL VALVE FOR DRY, PREACTION AND DELUGE APPLICATIONS

Features 1. Differential Latch-type, lightweight, dependable

SEE VICTAULIC PUBLICATION FOR DETAILS

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

with the specific application. Always read and understand the installation

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

Victaulic Discharge CBV Vibration Isolation Pump Drop Series 383/383G

*Applies to 6 x 4" No. 650 Reducer only. C to E. No No º Elbow Approx. Wgt. Each Lbs. kg. C to E Inches mm JOB/OWNER CONTRACTOR ENGINEER

Valves & Flow Control Components Valves & Flow Control Components

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

Wet pipe low flow foam/water manifold system

Worldwide Contacts. Technical Data

08.08 Vic-Check Valves

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL H-2 HALAR COATED 2 (DN50) - 6 (DN150)

Hole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

Instructions for Installation, Operation, Care, and Maintenance

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

70.03 Victaulic Vortex TM

Instructions for Installation, Operation Care and Maintenance

SWING CHECK VALVES SERIES 52-SC SERIES 600

TECHNICAL DATA. Q= C v P S. Table 1 - Valve Part Numbers and Specifications

flowit by Fig. FTBGW-20 Bronze Gate Valve, Non-Rising Stem BS 5154 PN20 Material Specifications Dimensions (mm)

TECHNICAL DATA. Trimpac 244a. April 15, 2011

TECHNICAL DATA P S. Q= Cv MODEL E-2 DELUGE VALVE HALAR COATED ANGLE STYLE

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

Transcription:

R IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS Series FireLock European Alarm Check Valve Stations Grooved X Grooved 0.0 VICTAULIC IS AN ISO 00 CERTIFIED COMPANY PRODUCT DESCRIPTION The Victaulic Series alarm check valve works as a check valve by preventing the reverse flow of water from the system piping to the water supply. The valve is trimmed with a water bypass line, which has an in-line swing check valve. The bypass line allows pressure surges to enter the system and to be trapped above the alarm check valve s clapper without the clapper lifting and causing false alarms. 0 VdS When a significant flow of water occurs, such as from an open sprinkler, the alarm valve s clapper lifts and allows water to enter the system. Simultaneously, water enters an intermediate chamber, which allows the water to activate an alarm either through a water motor alarm or through a water pressure alarm. These alarms continue to sound until the flow of water is stopped. The Victaulic Series alarm check valve is made from high strength, low weight ductile iron, and offers easy access to all internal parts. All internal parts are replaceable without having to remove the valve from the installed position. The rubber clapper seal is easily replaced without removing the clapper from the valve. The valve is painted inside and out to increase corrosion resistance. The valve is to be installed in the vertical orientation only; it can be used in both constant and variable pressure systems when the optional retard chamber is included in the trim piping. The Series is available grooved X grooved (all sizes). Standard grooved dimensions conform to ANSI/ AWWA C0. The valve is rated to Bar and is tested hydrostatically to Bar. Options The valve can be used in both constant pressure and variable pressure installations with the optional retard chamber. The body is tapped for main drain and all available trim configurations. The trim includes an integral alarm test drain valve, which allows testing of the alarm system without reducing the system pressure. Clapper Alarm Outlet Seat Exaggerated for clarity REGISTERED TRADEMARK OF VICTAULIC COPYRIGHT 00 VICTAULIC PRINTED IN U.S.A. 0 REV A Victaulic Company of America Phone: -00-PICK-VIC (-00--) Fax: 0-0- e-mail:pickvic@victaulic.com Victaulic Company of Canada Phone: 0-- Fax: 0-- e-mail: viccanada@victaulic.com Victaulic Europe Phone:---00 Fax: --0- e-mail: viceuro@victaulic.be Victaulic America Latina Phone: 0--00 Fax: 0--0 e-mail: vical@victaulic.com Victaulic Asia Pacific Phone: --0 Fax: --0 e-mail: vicap@victaulic.com

0.0 DIMENSIONS B K A A B G C D H E F J I Valve Size Dimensions centimeters A* A B B C D E F G H I J K DN00, 0,,00 0,00,,,,,00,,00,00,,0 DN0 0,,,00 0,00,0,,00,00 0,0,00,00,0,0 *The A dimension is the measurement from the top of the valve body to the bottom of the valve body (takeout dimension). NOTE: Overall height B is greatest height if optional retard chamber is not installed. Approx. Weight Each kg PERFORMANCE HYDRAULIC FRICTION LOSS SERIES // PRESSURE DROP Bar 0. " / DN 00 " / DN 0 The chart at right expresses the frictional resistance of Victaulic Series Alarm Check Valve in equivalent meters of straight pipe. 0.0 00 000 0000 00000 FRICTIONAL RESISTANCE Nominal Size mm Equivalent Length of Pipe meters 00, 0, Expressed in equivalent length of pipe C=0. FLOW RATE Liters Per Minute Series FireLock European Alarm Check Valve Stations

0.0 TRIM PACKAGES Trim packages available: Vertical trim for the Series Alarm Check Valve installed vertically. Trim packages include:. All required pipe and fittings.. All standard trim accessories.. All required gauges.. Alarm Pressure Switch. Control Valve (Series 0W Butterfly Valve) Optional accessories: Series Retard Chamber - Required when the Series Alarm Check Valve is installed in a variable pressure installation in order to reduce the possibility of false alarms. Series 0 Water Motor Alarm - The Series Alarm Check Valve is designed to activate a mechanical alarm when a sustained flow of water (such as an open sprinkler) causes the alarm check s clapper to lift from its seat. Waterflow Detectors: Waterflow detectors are available for installation on the riser. MATERIAL SPECIFICATIONS Valve Body: Ductile iron conforming to ASTM A-, grade --. Ductile iron conforming to ASTM A-, grade --, is available upon special request. Valve Body Seat Ring (Not Shown): Bronze, UNS- C00 (---) Seat O-Rings (Not Shown): Nitrile Clapper: Aluminum Bronze (UNS-C00) Clapper Seal: EPDM, ASTM D000 Clapper Shaft: - PH Stainless Steel Clapper Spring: 0 Stainless Steel Clapper Seal-Retaining Ring: Aluminum Bronze (UNS-C00) Clapper Shaft Retaining Bushings: CA0 Brass Cover Plate Gasket: Nitrile 0 BILL OF MATERIALS Valve Body Seal-Retaining Ring Clapper Shaft Retaining Bushing (Qty. ) Bolt Seal Clapper Shaft Seal Assembly Bolt Clapper 0 Cover Plate Gasket Clapper Spring Cover Plate Clapper Seal Cover Plate Bolts (Qty. ) Series FireLock European Alarm Check Valve Stations

0.0 PARTS With Vertical Trim Grooved X Grooved 0 SERIES 0 WATER MOTOR ALARM ULC LISTED 0 FM F ³ ₄ Optional Retard Chamber To System Normally Open (Lockable) To Drain Water Supply BILL OF MATERIALS Series FireLock European Alarm Check Valve Style 00 FireLock Rigid Coupling Series 0W Butterfly Valve Gauge Valve Water Supply Pressure Gauge (0- Bar) Swing Check Valve Restricted Orifice/Alarm Line Drain Reducer Reducing Bushing 0 EPS-0 Alarm Pressure Switch Alarm Line Ball Valve (Lockable - Normally Open) Series 0 Water Motor Alarm with ³ ₄-inch Strainer - 00 mesh (Optional) Series Retard Chamber (Optional) System Main Drain Valve System Test Valve System Pressure Gauge (0- Bar) Series FireLock European Alarm Check Valve Stations

0.0 OPERATION The Series Alarm Check Valve s construction includes a clapper, which has a replaceable rubber face. The clapper closure is assisted by a spring, which ensures proper contact of the clapper to the brass seat ring. When installed, the alarm check valve traps pressure above the clapper and prevents the reverse flow of water. Minor pressure surges pass through the bypass loop without lifting the clapper from its seat. The swing check valve in the bypass line traps the pressure above the clapper; this can be observed in the pressure gauges. The system-side water pressure will always be equal to or greater than the supply-side water pressure in the absence of an open sprinkler. When a sustained flow of water occurs, such as an activated sprinkler or an open inspector s test connection, the clapper lifts from its closed position; this allows water to enter the intermediate chamber through the holes in the seat ring. The water flows from the intermediate chamber to the alarm line and activates the system s alarms. These alarms continue to sound until the flow of water stops. Operation with an Installed Retard Chamber When the Series Alarm Check Valve is installed with the optional retard chamber, a surge of water, greater than what the bypass line can handle, will lift the clapper. When the clapper lifts, water will enter the intermediate chamber through the holes in the seat ring, and it will fill the retard chamber. The water then drains from the retard chamber through a restricted orifice. A sustained flow of water, as in an open sprinkler, will lift the clapper. Water will flow into the intermediate chamber, and it will fill the retard chamber completely; these events activate the water motor alarm and/ or the pressure switch for the electric alarm. WARNING This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Europe, Prijkelstraat, 0 Nazareth, Belgium, Telephone: ---00. All products shall be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Series FireLock European Alarm Check Valve Stations