Similar documents
PB -300 / 360 Instruction Manual

BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual

Features : 3 years warranty PB PB PB V 28.8V 57.6V 13.8V 86% 87% 89%

1000W Intelligent Single Output Battery Charger PB PB PB V 28.8V 57.6V 13.8V 85% 88% 89%

600W Intelligent Single Output Battery Charger 21A 10.5A VOLTAGE RANGE FREQUENCY RANGE

D R C- 4 0 s e r i e s

PB-600 SERIES 600 Watt Battery Charger Power Supply Measures: 9.06 x 6.22 x 2.64

UHP-500 series. 500W Slim Type with PFC Switching Supply

UHP-200 series. 200W Slim Type with PFC Switching Power Supply. File Name:UHP-200-SPEC GB4943 EN EN UL IEC

UHP-350 series. 350W Slim Type with PFC Switching Power Supply

Video & Power Over Coax Kit

350W Slim Type with PFC Switching Power Supply

PB-600 series. Jameco SKU Number: W Single Output Battery Charger SPECIFICATION MODEL

60W Single Output LED Power Supply. HBG-60 series. File Name:HBG-60-SPEC

SELV IP30 (CCC optional)

CX-SERIES ADVANCED BATTERY CHARGER

IS 15885(Part 2/Sec13) R ( for 24V only)

LPF-25 series. 25W Constant Voltage + Constant Current LED Driver

60W Constant Current Mode LED Driver. HBG-60 series. File Name:HBG-60-SPEC

TRC ELECTRONICS, INC DC/DC Converter SIP Package 6W MEAN WELL SPBW06 & DPBW06 Series

Jameco SKU Number:

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

DIN Rail Power Supplies

EMERGENCY VEHICLE BATTERY MANAGER PS2024

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

CX Series User s Manual

KNX-20E. 640mA KNX Power Supply. Isolation classⅠ. Installed on DIN rail TS-35/7.5 or 15. File Name:KNX-20E-SPEC Sicherheit ID

- 1 - Tel.: Fax: Battery charging units BLG2024 and BLG3524

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

Constant Voltage TRIAC Dimmable Driver---120W Series. Features

MD60 Series 60W DINergy Power Supply

PANcharge1k Battery Charger User's Manual

Battery chargers. Technical addendum.

Programmable Smart Charger

MODEL SELECTION TABLE Open Frame Models. MODEL SELECTION TABLE U-Chassis Models. MODEL SELECTION TABLE Enclosed Models

Industrial Power Supplies

RWS50B RWS100B RWS150B RWS300B RWS600B

1000W Intelligent Single Output Battery Charger 27.6V 55.2V OUTPUT CURRENT 16 ~ 18V 32 ~ 35V 64.5 ~ 69.5V OVER VOLTAGE PROTECTION

40A DC UPS Module SPECIFICATION MODEL DC INPUT / DC BUS DR-UPS40 24 ~ 29V 40A 21 ~ 29V 0 ~ 40A 2A 4 / 7 / 12AH / 24V

TDK-Lambda ZWS240BP/A SPECIFICATIONS

Switching Power Supplies

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

UNA SERIES Embedded Power Supply Features Model naming method UNA 350P / Applications UNA Conformity to RoHS Directive Product Line-up

PB-600 Instruction Manual

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

AC/DC Converter MBP250-2A13D13M

TDK-Lambda ZWS300BAF/A

+V -V D1 - D2 L N + - M6/8 M10/10 PE L N 13/02/2019 ALIMENTATION 48V 300W-SJN-V8. Code W. Al Jour/Nuit. Alarme. Al Jour. Relais. Relais.

SBC / 2140 / Stage Battery Charger User Manual

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

KNX-20E mA KNX Power Supply. Isolation classⅠ. Installed on DIN rail TS-35/7.5 or 15 KNX-20E_ EH-0817

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Specification of Battery Charger

Sentry Battery Charger. Installation and Operations Manual Section 75

ZWD100PAF. Conformity to RoHS Directive

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Specification of Soneil Battery Charger

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

Go Power! Manual. GP-Smart Charger

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-480 Series, 480W

DC DC Converter High Precision constant voltage high efficiency dedicated to the LED panel MODEL: EF-DC-8A

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

Guardian Battery Charger Series. Installation and Operations Manual Section 75

- PFC Function / Metal Case. - PFC Function / Economical Metal Case. - PFC Function / Plastic Case. - PFC Function / Plastic Case

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Phoenix Inverter

BECL10A BECL20A BECL25A BECL50A

AC CONVERTER / BATTERY CHARGER

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

SPECIFICATIONS SRF SuperchargerPlus

DC (on) LED Signal. Multiple output connector for easy wiring

GB60S 60W Single Output General Purpose Series

Switching Power Supplies

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

Note1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]

Smart Battery Charger

LS200 Series Instruction Manual

Test Report: UHP

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PRODUCTS: POWER SUPPLY

LEAB ChAmp. Product Specification. Idavägen Växjö Tel Fax Art 00438XX 00338XX

Output Voltage Range. Parameter Min. Typ. Max. Notes. Input Voltage 90 Vac Vac 127~300 Vdc

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

Notes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]

Open Frame Power Supplies

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

CBI All in One DC UPS Power Solutions

Transcription:

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner.

PB-300 / 360 USER'S MANUAL

SPECIFICATION : PB-300 MODEL BOOST CHARGE VOLTAGE FLOAT CHARGE VOLTAGE VOLTAGE ADJUSTABLE RANGE RECOMMENDED BATTERY OUTPUT CAPACITY(AMP HOURS)(Note 5) INPUT PROTE- CTION BATTERY TYPE OUTPUT CURRENT(max.) CONTINUOUS OUTPUT CURRENT (Typ.) (Note 6) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) POWER FACTOR (Typ.) FUNCTION REMOTE CONTROL (CN5) ENVIRO- NMENT AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD REVERSE POLARITY OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS HARMONIC CURRENT EMS IMMUNITY PB-300P/N-12 14.4V 28.8V 13.6V 13 ~ 14.7V 80 ~ 200Ah Open & Sealed Lead Acid 20.85A 12.5A 90 ~ 132VAC / 180 ~ 264VAC selected by switch 47 ~ 63Hz 85% >0.65 (with P type) at 230VAC 6A/115VAC COLD START 60A <3.5mA / 240VAC 3A/230VAC 90 ~ 110% rated output current By internal fuse 15 ~ 17V PB-300P/N-24 27.2V 26 ~ 28.8V 40 ~ 125Ah 10.5A 6.25A Protection type : Constant current limiting, recovers automatically after fault condition is removed 86% 30 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Automatically derate charge current until zero Open: Normal work Short: Stop Charging -10 ~ +40 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.05%/ (0 ~ 45 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes EN60335-2-29 CB Approved by TUV WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMC (Note 4) EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 (only P type) Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A MTBF 115.8Khrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION NOTE PACKING 253*135*48.5mm(L*W*H) 1.45Kg; 6pcs/9.7Kg/0.93CUFT 1

SPECIFICATION : PB-360 MODEL BOOST CHARGE VOLTAGE FLOAT CHARGE VOLTAGE VOLTAGE ADJUSTABLE RANGE OUTPUT RECOMMENDED BATTERY CAPACITY(AMP HOURS)(Note 5) INPUT PROTE- CTION BATTERY TYPE OUTPUT CURRENT(max.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) POWER FACTOR (Typ.) FUNCTION REMOTE CONTROL (CN5) ENVIRO- NMENT AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD REVERSE POLARITY OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS HARMONIC CURRENT EMS IMMUNITY PB-360P/N-12 14.4V 28.8V 13.6V 13 ~ 14.7V 80 ~ 200Ah Open & Sealed Lead Acid 24.3A 90 ~ 132VAC / 180 ~ 264VAC selected by switch 47 ~ 63Hz 85% >0.65 (with P type) at 230VAC 7A/115VAC COLD START 60A <3.5mA / 240VAC 3.5A/230VAC 90 ~ 110% rated output current By internal fuse 15 ~ 17V PB-360P/N-24 27.2V 26 ~ 28.8V 40 ~ 125Ah 12.5A Protection type : Constant current limiting, recovers automatically after fault condition is removed 86% 30 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Automatically derate charge current until zero Open: Normal work Short: Stop Charging -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.05%/ (0 ~ 45 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes EN60335-2-29 CB Approved by TUV WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMC (Note 4) EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 (only P type) Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A MTBF 115.8Khrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION NOTE PACKING 253*135*48.5mm(L*W*H) 1.5Kg; 6pcs/10Kg/0.93CUFT 2

ON/OFF SWITCH 230/115VAC SWITCH 230 INLET 3 POLE IEC320 C14 Battery Connection LED +V -V SVR1 DC (+) DC (-) Warning Please make sure the polarity of the battery is connected correctly! Battery 3

Assembly Procedure: 1.Make sure the charger is shut off and choosing suitable wires to connect the charger and batteries based on the rating of charging current. The polarity must be correct: charger output (+) should be connected to the (+) terminal of batteries and charger output (-) should be connected to the (-) terminal. In no times should the (+) and (-) be short together or the charger and batteries will be damaged. 2.Select the correct input voltage range between 115VAC and 230VAC. The selecting switch is preset at 230VAC in the factory. 3.Set the ON/OFF(0/ -) power switch to ON( -) and check whether the operation of LED is correct (red : charging; green : battery is full). Notes On Operation: 1.The charger is only suitable for "lead-acid" batteries. 2.The charger should be assembled in the place with good ventilation and low moisture. Exposure to the rain or snow is strictly prohibited. 3.Wires connecting between the charger and batteries should be as short as possible since the high voltage drop on the wires will increase the time required to fully charge the batteries. 4.Make sure the charging voltage and charging current are suitable for the batteries you are using. 5.If the batteries need to connect in series for charging, old batteries are not suggested to be used with new ones or the lifetime of batteries may reduce because of the unbalance charging voltage distribution on new and old batteries. 6.Please turn off the charger before connecting or disconnecting the wires. 7.The charger has a 2-year worldwide warranty, however, damages from misusing the charger will not be included in the coverage of warranty. Status Under General Operation: At the beginning stage of operation, the charger provides the largest current with 14.4Vdc of output voltage (for 12V batteries) to charge batteries. The LED indicator will lighten in red and the built-in fan will spin to dissipate the heat (360W only). After a period of time (probably a couple of hours, based on the capacity of batteries), the charging current will decrease gradually. After reaching 10% of its maximum value, the charger will go into "floating-charge" stage. The fan will stop spinning, charging voltage will decrease to 13.6Vdc, and the LED indicator will turn to green. The relationship between charging current and charging voltage for each operation stage are shown in the curves below: 4

Start V boost Charge Voltage V FLT 100% Charge Current stage 1 stage 2 stage 3 Constant Current Constant Voltage Floating LED COLOR Red Green State PB-300/360-12 Vboost 14.4V PB-300/360-24 28.8V VFLT 13.6V 27.2V NOTE: Output voltage of the charger (V FLT) can be adjusted through SVR1 without connecting the batteries and this adjustment will change the value of Vboost at the same time. For example, if originally VFLT is 13.6V and Vboost is 14.4V, after adjusting VFLT to 13.2V under no-load condition, Vboost will also reduce to 14V. So, please consult the manufacturer of batteries about the suitable charging voltage before make any adjustment. Charging Current And Ambient Temperature 1.The charging current of PB-300 will reduce when the ambient temperature goes up. Please refer to the derating curve shown as below: 100 90 80 70 LOAD (%) 60 40 30-10 0 10 20 25 30 40 50 EXTERNAL CASE TEMPERATURE ( ) 5

2.Below the ambient temperature of 40, PB-360 can provide the maximum charging current to the batteries. If the ambient temperature is higher than 40, the output current of PB-360 will decrease automatically. Please refer to the derating curve shown as below: 100 90 80 70 LOAD (%) 60 40 30 10 20 30 40 50 60 70 AMBIENT TEMPERATURE ( ) Selection Of Output Connection: Please choose wires with suitable diameter of its cross section based on the current rating. Please refer to the following table for the information of some frequently used wires. Using red wires to connect the (+) terminals and black ones for (-) terminals is highly recommended. (Black wires for grounding is a usual practice in electrical applications.) AWG 2 CROSS SECTION(mm ) Max.Current(A) UL1015(600V 105 ) 10 5.262 35 12 3.309 22 14 2.081 12 16 1.309 8 18 0.823 6 20 0.517 4 Suggested Battery Capacity: 1.It will not have any problem if the capacity of batteries larger than the suggested value. It just takes more time to make the batteries fully charged! 2.If you have any question about the suitable charging current for the batteries, please refer to the technical data provided by the battery manufacturers or consult the vendor of the batteries. Model PB-300-12 PB-300-24 PB-360-12 PB-360-24 Suggested Battery capacity 60-100Ah 30-60Ah 80-200Ah 40-125Ah 6

Notes On Failure Elimination Status Possible Reasons Power switch is not set to ON(-) Ways to Eliminate Set the power switch to ON(-) No output voltage Wrong polarity of the battery connection (output fuse open) Wrong selection of the 115/230Vac switch Replace the fuse Repair required. Please send it back to us or any of our distributors Output voltage is too low Can't achieve the FLOAT (green light) stage after long period of charging operation Wrong selection of the 115/230Vac switch Batteries are aging or broken The gauge of output wire is not large enough Choose the correct input voltage range through the 115/230Vac switch Replace the batteries Choose connecting wires with suitable gauge If you still cannot eliminate the failure situation, please consult MEAN WELL or any of our distributors WARNING : Explosive gases. prevent flames and sparks, Provide adequate ventilation during charging. Disconnect the supply before making or breaking the connections to the battery. Against recharging non-rechargeable batteries. Caution : (1)Temperature of the case will be high during the charging operation. (2)If the AC input terminal does not connect to F.G. or the ground, then the case should be grounded or the leakage current may harm the users while touching the case. (3)The charger should be fixed firmly at its operation place or be mounted on a holding rack for extra support. Reserved space for built in is at least (325*145*55) L*W*H (4)During charging, the battery must be placed in a well ventilated area. 7