Communications. Auxiliary. Functions. output. functions. Transistor. Heating or cooling control is selectable (See note 2.

Similar documents
3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

Digital Temperature Controller

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Switching Power Supply

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

24-hour/Weekly Time Switch H2F

Model Number Structure

Temperature Controllers

Temperature Controllers

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Model Number Structure

Switching Power Supply

1/16 DIN Temperature Controller E5CS

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Model Number Structure

H3DS-X - Solid State Two-Wire Timer

Surface mounting, flush mounting, and DIN track mounting

Safety Precautions. Safety Precautions for

Transistor Remote Modules

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Model Number Structure

Model Pressure range ON/OFF output Linear output

SYSMAC Transistor Remote Module

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Solid State Relays G3NA. Model Number Structure. Model Number Legend

Model Number Structure

Power Controller. (see note 1) 10 sec

Hinged Safety Door Switch

Analog Input Terminal

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Safety-door Switch. Ordering Information

Digital display Pressure range ON/OFF output Linear output Model

Inductive Proximity Sensor

Module Type Controller SRX Temperature Control Module [Basic Type] X-TIO-A Instruction Manual

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Model Number Structure

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Differential Pressure Sensor

Analog Output Terminal

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

Digital display Pressure range ON/OFF output Linear output Model

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Model Number Structure

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Model Pressure range ON/OFF output Linear output

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

E5CSV temperature controller

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Inductive Proximity Sensor

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

Tactile Switch (Hinged Type)

FX2N-2LC SPECIAL FUNCTION BLOCK

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

Switch Mode Power Supply S8VS

Manual Reset Limit Switch

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Direct Coupled Damper Actuator Model MY6050A1001

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

2-Color Display High-Precision Digital Pressure Switch

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

Ordering Information. Text Surface-Mounting Signal Relay G6K

Slim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

2NC (slow-action) Direct. Model. opening

High-speed detection even a little liquid leak

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Transcription:

Modular Temperature Controller New In-panel DIN Track Mounting Temperature Controller Ordering Information RC : : Name Temperature Controller Terminal Unit Power supply 24 VDC 2 No. of control points Control output Voltage output (for SSRs) Transistor output Auxiliary output Transistor output: 2pts (sinking) Transistor output: 2pts (sourcing) Transistor output: 2pts (sinking) Transistor output: 2pts (sourcing) 1. Terminal Units are required for wiring. Purchase separately. 2. When using heating or cooling output functionality, the auxiliary output will be either heating control output or cooling control output. 3. When using the heater burnout alarm, purchase a Current Transformer (CT) separately. 4. Analog input and infrared temperature sensors (ES1A) can also be used with thermocouple models. 1. When using 2 or more s mounted side-by-side, use the -SCT18S-5 for the second and subsequent Units. When using s separately, be sure to use the -SCT24S-5. 2. Two End Plates are provided with -SCT24S-5 Terminal Units. When mounting to a DIN track, be sure to mount End Plates on both sides. Current Transformer (CT) (Sold Separately) Functions Heating or cooling control is selectable (See note 2.) Heater burnout alarm (See note 3.) Event input: 1 point per Unit Two channels of temperature control available despite width of only 22.5 mm. The Temperature Controller itself can be replaced without changing terminal wiring. Use in combination with a compact Setting Display Unit to reduce communications programming requirements. A wide variety of operation indicators (single-color LEDs) enable easy operation monitoring. Power supply and communications wiring not required between Units when mounted side-byside. Communications functions RS-485 Terminal Cover Input type Model Thermocouple -2QNH3TC-FLK Platinum resistance thermometer -2QNH3P-FLK Thermocouple -2QPH3TC-FLK Platinum resistance thermometer -2QPH3P-FLK Thermocouple -2TNH3TC-FLK Platinum resistance thermometer -2TNH3P-FLK Thermocouple -2TPH3TC-FLK Platinum resistance thermometer -2TPH3P-FLK Name No. of terminals Functions Model 24 18 (See note 1.) Equipped with communications terminals for power supply, communications, and setting devices. Not equipped with communications terminals for power supply, communications, and setting devices. -SCT24S-5 -SCT18S-5 Model E54-CT1 E54-CT3 Diameter 5.8 dia. 12. dia. Model E53-COV12 E53-COV13 Type For SCT24S-5 models For SCT18S-5 models The Terminal Cover comes with the Terminal Unit and does not have to be purchased separately. 1

Setting Display Unit (Sold Separately) Name Power supply Model Setting Display Unit (See note.) 24 VDC -SDL Purchase sockets for wiring (shown in the table below) separately. Sockets (for Setting Display Unit - Sold Separately) Model P2CF-11 P2CF-11-E P3GA-11 Y92A-48G Type Front-connecting socket Front-connecting socket (with finger protection) Refer to the following manual for precautionary information and other information necessary to use the : Modular Temperature Controller User s Manual (Cat. No. H113). Input Range Platinum Resistance Thermometer Models and Thermocouple Models Input type Temperature range ( C) Name 18 17 16 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1-1 -2 Setting number 85 Platinum resistance thermometer models Platinum resistance thermometer Pt1 5. 5. 5. -2-199.9 1.. JPt1-199.9 1.. 13 85 4. 4 4. 6-2. -1-2. -2-2 -199.9 Thermocouple 85 4 4. -1-2 -199.9-2 Back-connecting socket Thermocouple models K J T E L U N R S B Terminal cover for finger protection 1 to 6 to 115 to16 to to 5 mv 7 C 12 C 165 C 26 C 18-1999 to 17 17 9999 or -199.9 to 999.9 by scaling 13 1 Infrared temperature sensor (ES1A) 9 12 165 26 Analog input 1 2 3 4 1 2 3 4 17 5 6 7 18 8 9 1 11 12 13 14 15 16 The applicable standards for the inputs types are as follows: K, J, T, E, N, R, S, B: JIS C162-1995, IEC584-1 L: Fe-CuNi, DIN 4371-1985 U: Cu-CuNi, DIN 4371-1985 JPt1: JIS C 164-1989, JIS C 166-1989 Pt1: JIS C 164-1997 IEC 751 Shaded parts indicate the settings at the time of purchase. Specifications Ratings Power supply voltage Allowable voltage range Power consumption Sensor input Control output 24 VDC 85% to 11% of the rated power supply voltage Approx. 3 W Thermocouple: K, J, T, E, L, U, N, R, S, B Infrared temperature sensor: 1 to 7 C, 6 to 12 C, 115 to 165 C, 16 to 26 C (ES1A Series) Voltage input: to 5 mv Platinum resistance thermometer: Pt1, JPt1 Voltage output Transistor output Output voltage: 12 VDC ±15% (PNP); Maximum load current: 21 ma; Equipped with short-circuit protection circuit Maximum operational voltage: 3 VDC; Maximum load current: 1 ma; Residual voltage: 1.5 V max.: Leakage current:.4 ma max. 2

Auxiliary output Event output Number of input and control points Setting method Control method Other functions Ambient operating temperature Characteristics : Transistor output Contact output Non-contact output Sourcing Sinking Input points: 2, Control points: 2 Maximum operating voltage: 3 VDC; Maximum load current: 5 ma; Residual voltage: 1.5 V max.; Leakage current:.4 ma max. ON: 1 kω max., OFF: 1 kω min. ON: Residual voltage: 1.5 V max., OFF: Leakage current:.1 ma max. Via communications or using the Setting Display Unit (-SDL) 2-PID or ON/OFF control Heater burnout detection function Multi-SP and RUN/STOP switching using event input -1 to 55 C (with no icing or condensation) For 3-years of assured use: -1 to 5 C Ambient operating humidity 25% to 85% Storage temperature -25 to 65 C (with no icing or condensation) Indication accuracy Hysteresis Thermocouple: (Indicated value ±.5% or ±1 C, whichever is greater) ±1 digit max. (See note 1.) Platinum resistance thermometer: (Indicated value ±.5% or ±1 C, whichever is greater) ±1 digit max. (See note 1.) Analog input: ±.5% or ±1 digit max..1 to 999 EU (in units of.1 EU) (See note 2.) Proportional band (P).1 to 999 EU (in units of.1 EU) (See note 2.) Integral time (I) to 3,999 s (in units of.1 s) Derivative time (D) to 3,999 s (in units of.1 s) Control period 1 to 99 s (in units of.1 s) Manual reset value. to 1.% (in units of.1%) Alarm setting range -1,999 to 9,999 (Position of decimal point depends on input type.) Sampling period 5 ms Insulation resistance 2 M9 min. (at 5 VDC) Dielectric strength 6 VAC for 1 minute at 5 or 6 Hz (between unlike terminals of charged parts) Vibration resistance 1 to 55 Hz, 1 m/s 2 for 2 hrs each in X, Y, and Z directions Shock resistance 15 m/s 2 max., 3 times each in ±X, ±Y, and ±Z directions Enclosure rating Temperature Controller: IP Terminal Unit: IP Memory protection EEPROM (non-volatile memory) (Number of write operations: 1,) Weight Approved standards Temperature Controller: Approx. 9 g Terminal Unit (1): Approx. 8 g Terminal Unit (2): Approx. 1 g UL File No.: E2593 CSA File No.: 23889-11484 CE EMS: ESD EN61326, EN61-4-2 (4 kv/contact, 8 kv/air) REM field EN61326, EN61-4-3 (1 V/m) Fast transient EN61326, EN61-4-4 (2 kv/dc power, 1 kv/i/o) Surge immunity EN61326, EN61-4-5 (line to ground: 2 kv/dc power 1 kv/i/o line to line: 1 kv/dc power) Conducted RF EN61326, EN61-4-6 (1 V) EMI: Radiated EN61326 Class A 1. The indication accuracy for T and N thermocouples at -1 C, and for U and L thermocouples is ±2 C ±1 digit max. There is no specification for the indication accuracy for the B thermocouple used at 4 C max. The indication accuracy for R and S thermocouples at 2 C max. is ±3 C ±1 digit max. 2. "EU stands for Engineering Unit. 3

Communications (Host Communications) Transmission line connection method Communications method Synchronization method Baud rate Transmission code Data bit length (See note.) Stop bit length (See note.) Error detection Flow control Interface Retry function Number of Units that can be connected in parallel RS-485 multipoint RS-485 (2-wire, half-duplex) Start-stop synchronization 4,8, 9,6, 19,2, or 38,4 bps ASCII 7 or 8 bits 1 or 2 bits Vertical parity (none, even, odd) BCC (block check character) None RS-485 None 16 Units max. (32 channels) The baud rate, data bit length, stop bit length, and vertical parity can all be set independently as host communications settings. Setting Display Unit (Sold Separately) Ratings and Characteristics Current Transformer (CT) Ratings (Sold Separately) Dielectric strength 1, VAC (1 minute) Vibration resistance 5 Hz, 98 m/s 2 Weight Accessories (E54-CT3 only) Heater Burnout Alarm Characteristics Maximum heater current Input current readout accuracy Heater burnout alarm setting range Minimum detection ON time : E54-CT1: Approx. 11.5 g E54-CT3: Approx. 5 g Armature (2) Plug (2) Single-phase, 5 A AC (See note 1.) ±5% FS ±1 digit max.. to 5. A (in units of.1 A) (See note 2.) 19 ms (See note 3.) 1. Use the K2CU-F@@A-@GS (with GATE input terminal) for burnout detection of 3-phase heaters. 2. If the heater burnout alarm setting is set to. A, the alarm is always OFF, and if it is set to 5. A the alarm is always ON. 3. If the ON time for control output is less than 19 ms, heater burnout detection and heater current measurement will not be performed. Power supply voltage Allowable voltage range Power consumption Display method Ambient operating temperature Ambient operating humidity Storage temperature Communications method Communications format Insulation resistance Dielectric strength Vibration resistance Shock resistance Enclosure ratings Memory protection Weight 24 VDC 85% to 11% of the rated power supply voltage Approx. 1 W 7-segment digital display and singlecolor display -1 to 55 C (with no icing or condensation) For 3-years of assured use: -1 to 5 C 25% to 85% -25 to 65 C (with no icing or condensation) RS-485 (half-duplex) Fixed (baud rate: 38,4 bps; data bit length: 7 bits; even parity; stop bit length: 2) 2 M9 min. (at 5 VDC) 1,5 VAC for 1 minute at 5 or 6 Hz (between unlike terminals of charged parts) 1 to 55 Hz, 2 m/s2 for 2 hrs each in X, Y, and Z directions 3 m/s 2 max., 3 times each in ±X, ±Y, and ±Z directions Front panel: IP5 Rear case: IP2 Terminal case: IP EEPROM (non-volatile memory) (Number of write operations: 1,) Approx. 1 g Fittings: Approx. 1 g 4

Nomenclature -2 Operation Indicators POWER Lights when power is turned ON. ERROR Lights when a fatal error (e.g., memory error, AD error, or sensor error) occurs. SD/RD (Communications Operation) Flashes during communications with the host. OUT1 (Control Output 1) Lights when the control output 1 is ON. OUT2 (Control Output 2) Lights when the control output 2 is ON. SUB1 (Auxiliary Output 1) Lights when the auxiliary output 1 is ON. SUB2 (Auxiliary Output 2) Lights when the auxiliary output 2 is ON. POWER ERROR SD/RD OUT1 OUT2 SUB1 SUB2 Unit Number Setting Setting range of to F allows up to 16 Units to be set. Baud Rate -SDL The following diagram shows the names and functions of the -SDL parts for when it is connected to the -2@@@@@@@. Operation Indicators These indicators indicate the terminal operations for the -2@@@@@@@. OUT1, OUT2 (Control Output 1, Control Output 2) Light when the control output 1 or the control output 2 functions are ON. SUB1, SUB2 (Auxiliary Output 1, Auxiliary Output 2) Light when the auxiliary output 1 or the auxiliary output 2 functions are ON. STOP Lights when operation stops. Lights for an event or when RUN/STOP is set to STOP during control. Remains unlit at other times. CMW (Communications Write Control) Lit when communications write is permitted and unlit when it is prohibited. There are also indicators that are not used with the -2@@@@@@. (SUB3, SUB4) Unit/Channel Indicator Indicates the unit number and the channel number. Level Key Press this key to switch setting levels. Mode Key Press this key to switch setting data within the setting level. Temperature Unit Displayed when the display unit for setting data is temperature. The display is determined by the setting for temperature unit, with either C or F displayed accordingly. UNIT Key Press to switch the unit number. Level Key and Mode Key Press together to switch to protect mode. No. 1 Display Displays the PV or the type of setting data. No. 2 Display Displays the target value, the control variable, or the set value for setting data (setting contents). Up Key Each time this key is pressed, the the value displayed in No. 2 Display increases. If it is held down, the rate of increase becomes faster. It can also be used to move to the next setting item. Down Key Each time this key is pressed, the the value displayed in No. 2 Display decreases. If it is held down, the rate of decrease becomes faster. It can also be used to return to the previous setting item. Channel Key Press this key to change channel number. Copy Key Press this key to read all the settings from the Temperature Controller to the Setting Display Unit, or to write from the Setting Display Unit to the Temperature 5

Dimensions All units are in millimeters unless otherwise indicated. -2@@ @@H3@-FLK Connected to -SCT24S-5 When only using one Unit, purchase the -2@@H3@-FLK and the -SCT24S-5 together. Also, when using horizontal side-by-side mounting, purchase the first Unit together with the -SCT24S-5. -2@@ @@H3@-FLK Connected to -SCT18S-5 When mounting Units side-by-side, purchase the -2@@H3@-FLK together with the -SCT18S-5 for the second and subsequent Units. Refer to the following manual for precautionary information and other information necessary to use the : Modular Temperature Controller User s Manual (Cat. No. H113). 6

End Plate PFP-M Spacer PFP-S Eight, M4 pan-head screws M4 spring washer End Plates are provided with the -SCT24-5. Be sure to mount End Plates at both ends of Unit blocks. Current Transformer (Sold Separately) E54-CT1 E54-CT3 2.36 dia. 5.8 dia. 12 dia. 4 4 Two, 3.5 dia. Two, M3 (Depth: 4) E54-CT3 Accessories Armature Plug Approx. 3 dia. Approx. 6 dia. Connection Example Plug Armature Lead wire Mounting Track (for DIN Track Mounting - Sold Separately) PFP-1N PFP-5N * indicates dimensions for the PFP-5N. 7

Setting Display Unit -SDL Panel Cutout Dimensions Individual Mounting Side-by-side Mounting 48 48 6 (84) 63.7 14.2 (48 No. of Units 2.5) +1. 45 +.6 44.8 44.8 6 min. 45 +.6 45 +.6 The mounting panel thickness is 1 to 5 mm. Vertical side-by-side mounting is not possible. (Allow sufficient space above and below.) When mounting several Units, make sure that the ambient temperature specifications are not exceeded. -SDL Wiring Sockets Front-connecting Sockets P2F-11 (Standard Model) 5 max. 31.2 max. Two, 4.5-dia. holes 4 7 max. 35.4 Terminal Arrangement/ Internal Connections Eleven, M3.5 7.5 Sems screws 7.8 3 4.5 (TOP VIEW) Mounting Hole Cutout Dimensions P2F-11-E (with Finger Protection) Two, M4 or 4.5 dia. 5 max. 4.2 31.2 max. 3 4.2 Two, 4.5-dia. holes 3 7 max. 1.2 35.4 4 DIN track mounting is also possible. Eleven, M3.5 7.5 set screws 7.8 5 4.5 Back-connecting Sockets P3GA-11 (Standard Model) 27 dia. 4 7 3 Terminal Arrangement/ Internal Connections (BOTTOM VIEW) 45 25.6 45 4.5 16.3 Use in combination with a Terminal Cover (Y92A-48G) for finger-protection specifications. 6.2 8.7 6 8

Terminal Cover Y92A-48G Twelve, 6.4 dia. 34 47.7 47.7 48 48 16.5 24.6 27.6 47.4 Installation Connections Diagrams Voltage output (control output) is not electrically isolated from internal circuitry. Therefore, when using grounded thermocouples, do not ground control output terminals. (Doing so may result in temperature measurement errors due to unwanted current paths.) There is basic insulation between the power supply inputs and outputs for this product. If reinforced insulation is required, connect the input and output terminals to equipment without any exposed charge-carrying parts, or to equipment with basic insulation sufficient for the maximum operating voltage of the power supply and the inputs and outputs. Using with the -SCT24S-5 24-VDC input power supply Wiring for terminals 1 to 18 is the same as for the -SCT18-5. See below. -SDL (RS-485) RS-485 host Using with the -SCT18-5 Models with PNP Sourcing Outputs Models with NPN Sinking Outputs Voltage Output Models Transistor Output Models Contact input Noncontact input 12 VDC 21 ma 12 VDC 21 ma Event input Thermocouple Models Platinum Resistance Thermometer Models Heater burnout detection function 9

-SDL When the -SCT24S-5 is used Do not use. 24 VDC input power supply Host side (RS-485) Do not use. : 1. Terminals 4 and 9, 7 and 11, and 8 and 1 are connected internally at the -SDL side. 2. Do not connect anything to terminals 1, 2, 5, and 6. Purchase either a P2CF-11 or a P3GA-11 Socket separately. (Refer to page 8.) 1

Precautions General Precautions The user must operate the product according to the performance specifications described in the operation manuals. Before using the product under conditions that are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the product are sufficient for the systems, machines, and equipment, and be sure to provide the systems, machines, and equipment with double safety mechanisms. Safety Precautions Definition of Precautionary Information The above symbol indicates a situation that may result in injury or property damage. Warnings Do not allow metal fragments or lead wire scraps to fall inside this product. These may cause electric shock, fire, or malfunction. Do not use the product in locations subject to flammable or explosive gases. Doing so may result in explosion. Do not touch any of the terminals while the power is ON. Doing so may result in electric shock. Provide at least one power-interruption switch to ensure that the power is OFF before wiring. Not doing so may result in electric shock. To maintain safety in the event of a product malfunction, always take appropriate safety measures, such as installing an alarm on a separate line to prevent excessive temperature rises. If a malfunction prevents proper control, a major accident may result. Do not attempt to disassemble, repair, or modify the product. Any attempt to do so may result in malfunction, fire, or electric shock. Tighten screws to the specified torques given below. Loose screws may result in burning or malfunction. -SCT@S-5:.4 to.56 N m -SDL:.74 to.9 N m Set all settings according to the control target of the product. If the settings are not appropriate for the control target, the product may operate in an unexpected manner, resulting in damage to the product or accidents. Application and Operating Environment Precautions Observe the following points to ensure safe operation. 1. Use and store the product within the specified temperature and humidity ranges. Cool the product (e.g., using fans) where necessary. 2. Do not touch the electronic components or pattern of the PCB. Hold the product by the case. 3. To ensure proper heat dissipation, leave a space around the product. Do not block the product s ventilating holes. 4. Use at the rated power supply voltage with the rated load. 5. Be sure to connect terminals with the correct polarity. 6. Perform wiring using crimp terminals of the specified size. (-SCT@S-5: M3., width 5.8 mm max.; -SDL: M3.5, width 7.2 max.) 7. Be sure to use wires satisfying the following specifications for connection using bare wires. Power supply terminals: AWG 22 to 14 Other terminals: AWG 28 to 16 (Length of exposed part: 6 to 8 mm) 8. Do not connect anything to unused terminals. 9. Ensure that the rated voltage is reached within 2 seconds of turning power ON. 1.Allow 3 seconds warm-up time. 11.Install the product as far away as possible from devices that generate strong, high-frequency noise and devices that generate surges. 12.Keep wiring separate from high-voltage power lines or power lines carrying large currents. Do not wire in parallel with or together with power lines. 13.Install switches or circuit-breakers so that the user can turn the power OFF immediately, and indicate these accordingly. 14.Do not use the product in the following locations: Locations subject to dust or corrosive gases (in particular, sulfide gas and ammonia gas) Locations subject to freezing or condensation Locations exposed to direct sunlight Locations subject to vibrations or shocks Locations subject to exposure to water or oil Locations subject to heat radiated directly from heating equipment Locations subject to intense temperature changes 15.When the Terminal Unit is separated from the Temperature Controller, under no circumstances touch the electrical components or apply shock to the Temperature Controller. 16.Do not use solvents to clean the product. Use commercial alcohol. 17.After wiring is completed remove the dust-protection label to allow proper heat dissipation. 18.When mounting the Temperature Controller to the Terminal Unit, make sure that the hook on the side of the Temperature Controller facing the Terminal Unit is inserted properly. 19.Install the DIN track vertically. Correct Use Service Life Use within the following temperature and humidity ranges: Temperature: 1 to 55ºC (with no icing or condensation) Humidity: 25% to 85% If the product is installed inside a control panel, the temperature around the product (and not the temperature around the control panel) must be kept below 55ºC. With electronic devices like the, the service life will depend not only on the number of switching operations performed by the relay but also on the service life of the internal electronic components. The service life of these components depends on the ambient temperature; it will be shorter if the ambient temperature is high, and longer if the ambient temperature is low. For this reason, the service life of the product can be lengthened by keeping the inside of the at a low temperature. 11

If several Units are mounted side-by-side or are arranged vertically, the heat generated may cause the internal temperature of the Units to rise, reducing service life. To prevent this, take steps to ensure that the Units are cooled, such as installing fans. Ensure, however, that the terminals are not also cooled, otherwise correct temperature measurement will not be possible. Measurement Accuracy When extending the lead wires for thermocouples, use a compensating conductor appropriate for the type of thermocouple used. When extending the lead wires for platinum resistance thermometers, use lead wires with a low resistance, and make the resistance in the 3 lead wires equal. Mount the horizontally. If significant errors occur, check that input compensation has been set correctly. Waterproofing The enclosure ratings are given below. Parts for which the enclosure rating is not clearly indicated, and parts with IP@ ratings (where @ is not ) do not have waterproof specifications. Temperature Controller: IP Terminal Unit: IP Mounting and Dismounting To mount using a mounting track, first hook part A (see below) onto the track and then push down on part B. To dismount, insert a flat-bladed screwdriver into part C, pull the hook down, and then lift the bottom part of the upwards. Stopper 3 mm min. Mount the at least 3 mm away from other devices to ensure easy mounting and dismounting. Refer to the following manual for precautionary information and other information necessary to use the : Modular Temperature Controller User s Manual (Cat. No. H113). ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by.3937. To convert grams into ounces, multiply by.3527. Cat. No. H116-E1-1 OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Measuring and Supervisory Controls Department Shiokoji Horikawa, Shimogyo-ku Kyoto, 6-853 Japan Phone: (81)75-344-78/Fax: (81)75-344-7189 Printed in Japan 12-1M (12) (A) 12