FCC DUCTABLE AIR TREATMENT UNIT

Similar documents
CENTRIFUGAL FAN COIL UNIT VCE

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

Maestro. High Pressure Fan Coil Unit with Asynchronous Motor

Carisma CRC. Range includes 9 air rates (from 105 to 1500 m 3 /h) It is the most comprehensive range, perfectly suited to meet

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Carisma The Ultra Quiet Fan Coil

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

YFCN Fan Coil Unit centrifugal fan 2 & 4 pipe system A complete range from 1.0 kw to 7.6 kw

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Chilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

Product Catalogue ARMONIA Providing indoor climate comfort

EURUS / EURUS-I. Conditioning your ambient, maximising your comfort.

ERP 2015 Regulation (EU) Compliant with. No. 327/2011. Cert. n Heating. Meltemi Door Curtains

Highline 260i EC Waterside Fan Coil Unit

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

WATER SOURCE HEAT PUMPS

Ductable water unit FWD UNT-PRC002-E4

FCX TECHNICAL BOOKLET

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Fan coils with Inverter Brushless motor (EC) Concealed installation

Fan Coil Units. Technical Data. Flexi type unit ECDEN FWD-AT/AF

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

Low Static Pressure Duct(V shape evaporator)

Engineering Data Book

Low Static Pressure Duct (V shape evaporator)

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

GigaBox centrifugal fans Product specific information

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

CHP

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

PCB COMMERCIAL SERIES

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

High Static Pressure Duct Fan Coil Unit

AKOR-HR NEW HIGH EFFICIENCY HEAT RECOVERY UNIT. Heat Recovery AKOR-HR. Easy maintenance. EN AKOR-HR 14/1/08 13:01 Página 599

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

BRIZA 22 HYBRID HEATING & COOLING

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

AHN 064 to 304 EHN/CHN 064 to 304

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

INTRODUCTION CP 06 F C - A 4 L - F GENERAL DESCRIPTION DESIGN PARAMETER DUCTED CONCEALED WITH PLENUM. F - c/w Filter

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

NFCC Hydronic Terminal. Unit Description. Availale Models

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

Silent centrifugal air heater hot water supply

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

PHCD-Series. Catalog

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

42C/D SERIES Ducted Chilled Water Fan Coil Unit With District Cooling Application

Prepared By : Checked By : Approved By : Page 1 out of 6

Accessories. Series REC

Engineering Data Book

Air Cooled Packaged Units

D M S 760 C01 A A 1 1

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Address: VTS Clima L.L.C.

Technical Service Manual

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

ECLIPSE TURBO BLOWERS SERIES SMJ

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

PRODUCT CATALOGUE CHILLED WATER CASSETTE CWC

The World Leading Air-conditioning Company

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

Fan coil unit NBS 100/150

EC Motor MultiZone Fan Coil Units. IXDL-Y Series l/s

RKB. Heat recovery units from 100 to m 3 /h >50 %

CLIMA-ZONE TERMINAL UNIT FOR HEATING AND COOLING MULTIPLE ROOMS. Ductable EC system, by constant pressure zones

CHILLED WATER FAN-COIL UNITS

BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE TECHNICAL CATALOGUE

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Transcription:

FCC DUCTBLE IR TRETMENT UNIT DUCTBLE IR TRETMENT UNIT

FCC 7 different sizes 3, 4 and 6 row coils 2 or 4 pipe system Horizontal installation ductable air treatment unit FCC series The ductable air treatment units are available in 2 versions and 7 sizes. Units are extremely suitable for small centralized conditioning systems connected by a small ducting network. The small height of these units, make them the convenient solution for false ceiling installation. RM BM PM SRE GM FM 360 INDOOR CLIMTE SOLUTIONS

Structure Made of galvanised steel (1 mm gauge) and insulated in all parts in direct contact with the conditioned air. Galvanised steel insulated condensate tray, with drain plug for complete drainage. Ceiling-anchoring slots for easy fi xing and levelling of the unit. Heat exchanger Coils are made of copper pipe expanded into aluium fi ns. Copper headers with male fi ttings (GS threads) and easily accessible air vents. In standard version the water connections are located on the left side(looking at the air outlet). On request, the water connections can be placed on the right side of the unit. Blower section Double-inlet centrifugal fans with statically and dynamically balanced horizontally-oriented aluium impellers. Single-phase asynchronous electric motor with overload cut-out. The motor with three speeds is directly coupled to the fans and cushioned with fl exible mountings to ensure low noise levels. SF SSP RM www.eden-clima.com

FCC 400 29 P 29 26 204 26 26 204 26 30 70 341 44 51 51 50 50 50 50 B L B 51 B 51 B 50 B 50 B 50 B 50 B B 76 76 11 11 11 11 115 H 26 26 11 44 11 11 11 ØBM ØF ØC ØC SSP FCC SRE PM BM RM RM 90 intake/supply plenum BM Intake/supply section with spigots PM Straight intake/supply plenum SRE Heating section with electric heater (380V), made according to the international security standard. It is supplied complete with safety thermostat with automatic reset, interface relay, electric wiring control teral and main switch. GM ntivibrating joint FM Connecting fl ange SSP SF Section with fresh air louver (manual). Made of galvanised steel, it allows the fl ow of external air in the room. Inside air fl ow: 100% 66,6%. External air fl ow: 0% 33,3% ir fi lter section. Easily extractable, made of a metal frame containing the fi ltering element. Filter class G3, regenerable by washing with water or air blowing. Valves 2 or 3 way uxiliary coil for heating (4 pipe system) Coil 4 and 6 rows 360 INDOOR CLIMTE SOLUTIONS

FCC 60-70 No Eurovent certifi ed 10 20 30 40 50 60 70 Maximum external static pressure () reducing unit performance of 50% 2 pipe system 4 pipe system 105 105 135 135 205 260 260 95 95 130 130 180 240 240 90 80 115 105 135 220 220 95 90 120 120 180 220 220 85 80 115 115 155 210 210 75 70 95 90 110 180 180 Minimum air pressure loss necessary to ensure the correct functioning of the units Minimum air pressure loss 0 0 0 0 0 60 60 FCC 60-70 No Eurovent certifi ed 10 20 30 40 50 60 70 Fans - motors n Standard coil Rows n Fittings (ØF) Ø uxiliary coil Rows n Fittings (ØC) Ø Condensate drain fi ttings (ØC) Ø mm Height H mm External dimensions Lenght L mm Depth * P mm Intake mm Supply M mm B mm C mm D mm E mm N. x Ø BM mm Net weight kg 1-1 2-1 2-1 2-1 2-1 1-1 2-2 3 3 3 3 3 4 4 1/2 1/2 3/4 3/4 1 1 1/4 1 1/2 1 1 1 1 1 2 2 1/2 1/2 1/2 3/4 3/4 1 1 1/4 20 20 20 20 20 20 20 300 300 325 325 375 675 675 650 1.000 1.100 1.340 1.340 1.341 2.028 533 533 533 533 533 853 853 197 197 222 222 272 572 572 197 197 222 222 272 390 * 390 * 548 898 998 1.238 1.238 1.238 1.926 400 400 400 400 400 725 725 67 67 67 67 67 118 118 340 340 340 340 340 650 650 2xØ200 3xØ200 3xØ200 4xØ200 4xØ200 2xØ400 4xØ400 28 36 41 46 57 117 192 * On request: supply dimension as intake dimension. GENERL DIMENSIONS FCC 10-50 51 B 51 29 P 29 44 37 44 77 26 77 M 26 H L 107 Ø 20 FCC 60-70 51 B 51 29 P 29 70 34 37 70 77 26 259 M 26 H L 137 Ø 20 www.eden-clima.com

FCC C FCC 60-70 No Eurovent certifi ed 10 20 30 40 50 60 70 2 pipe system (3R coil) 3090 5600 8900 9400 13100 24640 44800 Total cooling capacity 2960 5300 7800 8980 11500 23300 42880 2830 4500 7390 7400 8080 20810 38400 2400 4340 6570 7510 9600 18370 34400 Sensible cooling capacity 2300 4100 6220 7130 8400 17350 32810 2180 3300 5260 5750 6470 15340 29150 530 956 1400 1780 2560 4227 7675 ater fl ow 508 907 1368 1540 1785 3998 7358 486 778 1190 1270 1386 3450 6590 k 15,3 26,9 31,4 27,8 26 27,7 29,3 ater pressure drop k 14,2 23,2 22,5 25,3 20,8 25,3 28 k 13,1 17,2 22,2 16,5 13,3 21,1 27,2 3970 6700 10000 11200 16500 28820 53200 Heating capacity 3790 6310 9400 10800 14400 27160 50890 3600 5300 8350 8800 10000 24000 45200 530 956 1400 1780 2560 4227 7675 ater fl ow 508 907 1368 1540 1785 3998 7358 486 778 1190 1270 1386 3450 6590 k 13 22,6 26,1 23,3 22 22,6 23,8 ater pressure drop k 12 19,5 19,7 21,2 17,6 20,5 22,4 k 11 14,4 18,5 13,9 12,9 16,4 18,6 650 1064 1764 1780 2650 3946 7731 ir fl ow 610 940 1627 1728 2163 3645 7248 570 746 1293 1262 1442 3102 6193 60 60 59 60 60 122 121 Static pressure 50 50 50 50 50 100 100 35 35 31 35 35 67 77 Sound power level inlet + radiated db() db() db() 60 57 63 62 60 70 72 57 54 61 61 57 66 67 54 51 57 57 54 61 62 Sound power level outlet db() db() db() 64 61 67 66 65 74 75 61 58 65 64 61 69 70 58 55 60 60 59 64 65 Sound pressure level inlet + radiated db() db() db() 51 48 54 53 51 62 63 48 45 52 52 48 57 59 45 42 48 48 45 53 53 Sound pressure level db() db() outlet db() Power input bsorbed current ater content L - 55 52 58 57 56 65 66 52 49 56 55 52 61 62 49 46 51 51 50 56 57 160 240 320 340 580 1320 2600 0,72 0,97 1,43 1,51 2,58 5,86 11,54 1,36 2,18 2,63 3,25 3,79 9,38 14,44 - Standard unit with free outlet: external static pressure = 0 - Sound power level: ISO 23741 - Sound pressure level: 8,6 db() lower that the sound power level for a room of 90 m 3 with a reverberation time of 0,5 sec. - Supported power supply: ~230V±10% / 1ph / 50-60Hz COOLING Inlet water temp.: 7 C Outlet water temp.: 12 C Inlet air temp.: 27 C d.b. - 19 C w.b. HETING ir temp.: 20 C Inlet water temp.: 50 C HETING ir temp.: 20 C Inlet water temp.: 70/60 C 360 INDOOR CLIMTE SOLUTIONS

FCC 60-70 No Eurovent certifi ed 10 20 30 40 50 60 70 4 pipe system (3R+1R coil) 2870 6110 8100 8440 12300 21540 39500 Total cooling capacity 2860 5070 6340 8100 9970 20200 37300 2750 4500 5500 6600 8470 18300 33300 2400 4340 6700 6950 9650 17000 32000 Sensible cooling capacity 2360 3940 6000 6700 7540 15900 30100 2300 3450 5070 5400 6340 14300 26700 492 950 1384 1450 2116 3697 5359 ater fl ow 490 897 1088 1382 1712 3466 5105 473 768 944 1375 1453 3030 4639 k 15,4 26,9 31,5 24 25,8 21,1 25,1 ater pressure drop k 14,8 19 22 22 17,5 18,9 22,7 k 14 15 19,9 15 13,2 15,1 18,7 3400 6200 8250 9450 11500 33700 61000 Heating capacity 3370 5900 8000 9100 9500 31900 58100 3230 4700 6730 7800 8150 29400 52800 298 495 725 829 1010 3696 5360 ater fl ow 295 464 696 798 835 2804 5105 282 392 685 697 716 2495 4637 k 20,3 13 30 18 23 17,6 19,6 ater pressure drop k 19,5 11,1 28 16,5 16,3 15,6 17,7 k 17,7 8 21 12 12,4 13,4 14,8 570 1065 1750 1680 2640 3623 7143 ir fl ow 567 1014 1461 1560 1860 3308 6570 540 850 1180 1181 1470 2905 5613 60 60 55 60 60 123 125 Static pressure 50 50 50 50 50 100 100 35 35 35 35 25 68 80 Sound power level inlet + radiated db() db() db() 60 57 63 60 69 70 72 56 56 60 56 65 66 67 54 52 57 54 58 61 62 Sound power level outlet db() db() db() 64 61 68 64 69 74 75 60 60 64 60 66 69 70 58 55 62 58 58 64 65 Sound pressure level inlet + radiated db() db() db() 51 48 54 51 60 62 63 47 47 51 47 56 57 59 45 43 48 45 49 53 53 Sound pressure level db() db() outlet db() Power input bsorbed current ater content (cooling) L - ater content (heating) L - 55 52 59 55 60 65 66 51 51 55 51 57 61 62 49 46 53 49 49 56 57 160 240 320 340 580 1320 2600 0,72 0,97 1,43 1,51 2,58 5,86 11,54 1,36 2,18 2,63 3,25 3,79 9,38 14,44 0,45 0,73 0,88 1,08 1,26 4,69 7,22 - Standard unit with free outlet: external static pressure = 0 - Sound power level: ISO 23741 - Sound pressure level: 8,6 db() lower that the sound power level for a room of 90 m 3 with a reverberation time of 0,5 sec. - Supported power supply: ~230V±10% / 1ph / 50-60Hz COOLING Inlet water temp.: 7 C Outlet water temp.: 12 C Inlet air temp.: 27 C d.b. - 19 C w.b. HETING ir temp.: 20 C Inlet water temp.: 50 C HETING ir temp.: 20 C Inlet water temp.: 70/60 C www.eden-clima.com

GROUP S.p.. - Via Montegrappa, 67-31020 San Zenone degli Ezzelini (Treviso) - Italy Tel. +39 0423 567774 - Fax +39 0423 567985 - www.aliseogroup.com - info@agroup-it.com DP FCC 2013-0 GB