Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

Similar documents
Lenntech. Calio-Therm S. Type Series Booklet. High-efficiency Drinking Water Pump

4 Specification Magneta Smedegaard twin pumps

3 Specification Magneta Smedegaard

High-efficiency Drinking Water Pump. Rio-Eco Therm N. Type Series Booklet

Grey Water and Condensate Pump. Rotex. Type Series Booklet

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

Boiler Feed Booster Pump YNK. Type Series Booklet

Series description: Wilo-Stratos ECO-STG

Submersible Borehole Pump. UPAchrom. 4", UPAchrom 100 CC + DN 100. Type Series Booklet

Data sheet: Wilo-Stratos PICO 25/1-6

Data sheet: Wilo-Stratos PICO 25/

Planning is simple: with Calio circulators for commercial buildings

Circulator Pumps with Continuously Variable Differential Pressure Control and I.R. Interface for Remote Control

Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

Data sheet: Wilo-Yonos PICO 25/

Etanorm SYT Type Series Booklet

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

Waste Water, Condensate and Heat Transfer Fluid Pump. Type Series Booklet

Waste Water, Condensate and Heat Transfer Liquid Pump. Type Series Booklet

Heat Transfer Fluid / Hot Water Pump HPK-L. Type Series Booklet

Data sheet: Wilo-Yonos MAXO 40/0,5-16

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

RE, RED. Electronically Controlled Inverter Driven Circulation Pump. Twin Execution ENERGY EFFICIENCY OF CIRCULATING PUMPS

Data sheet: Wilo-Stratos-Z 25/1-8

Non-return Valve BOA-RVK PN 6/10/16 DN Type Series Booklet

High-efficiency Circulator Pump. HEP Optimo L+ Installation/Operating Manual

Thermal Oil / Hot Water Pump. Etanorm SYT. General Arrangement Drawings

Movitec VCI Type Series Booklet

BOA-Compact. Type Series Booklet

High-efficiency Circulator Pump. Installation/Operating Manual Magneta Smedegaard

Data sheet: Wilo-Stratos-D 32/1-8

TPE /2-S-A-F-A-BAQE 3X400 50HZ

Data sheet: Wilo-Stratos-D 50/1-12

Strainers BOA -S. PN 6/16/25 DN Flanged. Type Series Booklet

Series description: Wilo-Stratos

Strainer BOA-S PN 6/16/25 DN Type Series Booklet

General catalogue incl. replacement lists

CONDA-VRC Type Series Booklet

TPED /4-S-A-F-A-BAQE 3X400 50HZ

Actual-position Feedback Unit. SISTO-SK-i. For Valves with Linear Actuators Stroke: 5-46 mm. Type Series Booklet

Japanese Technology since Ego Circulators. Databook

BOA-Compact EKB. Type Series Booklet

Company name: Created by: Phone:

STAAL 40 AKK/AKKS. Type Series Booklet

BOA-SuperCompact. Type Series Booklet

Automated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet

High-efficiency Circulator Pump. Installation/Operating Manual Magneta D Smedegaard

TPE /4-A-F-A-BAQE 3X400 50HZ

SICCA SCC Type Series Booklet

TPE S-A-F-A-BUBE

BOA-CVP H. Type Series Booklet

Swing Check Valve AKR/AKRS. PN DN 80/80 to 300/250. Type Series Booklet

Manual Actuator. MA Manual Gearbox Force Transmission via Planetary Gear Torque Range up to 250 Nm. Type Series Booklet

TPE N-A-F-A-GQQE

Etaprime B Type Series Booklet

CONDA-VLC Type Series Booklet

Hydro MPC-E 3 CRIE5-9 U1 A-A-A-GH GNL

Swing Check Valve AKR/AKRS. PN DN 80/80 bis 300/250 Pressure Seal Design Flanged/Butt Weld Ends. Type Series Booklet

Heating, air-conditioning, cooling

MAGNA x230V PN10

CMBE Booster. Lenntech. Description 50/60 Hz. Horizontal, multistage centrifugal boosters

Heating, air-conditioning, cooling

TPE S-A-F-I-BQQE

Knife Gate Valve HERA-SH. PN 10/16, Class 150 DN Uni-directional Full-lug body. Type Series Booklet

BOA-H/HE/HV/HEV. Type Series Booklet

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)

TPE 25-80/2-A-O-A-BUBE 1X230 50HZ

ECOLINE GTF 800 Type Series Booklet

Grundfos Home Booster

Mag-drive Pump. Magnochem-Bloc. Type Series Booklet

NORI 40 RXL/RXS. Type Series Booklet

MAGNA F 220 1x230V PN6/10

BOA-H Mat E Type Series Booklet

BOACHEM ZYA. Type Series Booklet

BOACHEM FSA. Type Series Booklet

MAGNA3 D x230V PN10

NORI 500 RXLR/RXSR. Type Series Booklet

TPE N-A-F-A-GQQE

TP /2-A-F-A-BQQE 400D 50HZ

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)

Self-priming Pump. Etaprime B. Type Series Booklet

TP /2-A-F-A-BAQE 400D 50HZ

MAGNA x230V PN10

AKG-A/AKGS-A. Type Series Booklet

MAGNA3 D F 280 1x230V PN16

Data sheet: Wilo-TOP-Z 50/7 (3~400 V, PN 6/10, RG)

TP /4-A-F-A-BQQE 400Y 50HZ

TPED /4-A-F-A-BQQE 3X400 50HZ

NB80-160/161 A-F2-A-BQQE

Non-return Valve BOA-R. PN 6/16 DN Flanged. Type Series Booklet

AKG-A/AKGS-A. Type Series Booklet

Pump Stations for Heating Circuits

ECOLINE GTC Type Series Booklet

real quality made in italy circulation pumps

Body Pressure Relief Valve UGS. p approx. 750 bar DN 15. Type Series Booklet

NORI 320 ZXSV Type Series Booklet

BOAX-B Mat E. Type Series Booklet

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data

Data sheet: Wilo-TOP-Z 30/7 (3~400 V, PN 10, RG)

Transcription:

Lenntech info@lenntech.com Tel. +--6-9 www.lenntech.com Fax. +--66-89 High-efficiency Circulator Pump Type Series Booklet

Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft, Frankenthal 8..

Contents Contents Building Services: Heating......... Main applications... Fluids handled... Operating data... Designation... Design details... Materials... Product benefits... Certifications... Selection information... 6 Programme overview / selection tables... 7 Technical data... 8 Selection chart... 9 Characteristic curves... Dimensions... Installation information... Scope of supply...

Building Services: Heating Characteristic Value BMS Sound pressure level [db (A)] < Piping connection R /, R, R / Designation Example: -- Designation key Code Description High-efficiency pump Nominal diameter of pipe connection = R / = R = R / Head in m x (example: m = ) - Overall length mm BMS Building Management System Main applications Heating, ventilation, air-conditioning and circulation systems One-pipe and two-pipe systems Underfloor heating systems Boiler or primary circuits Storage tank circuits Solar power systems Heat pumps Fluids handled Heating water to VDI Can handle higher-viscosity fluids (e.g. water/glycol mixture up to mixing ratio of :) Pure, thin, non-aggressive and non-explosive fluids not containing any mineral oil, solids or long fibres Fluids with a viscosity of mm /s Operating data Operating properties Characteristic Value BMS Flow rate Q [m /h]. 7 Q [l/s]..9 Head 6 Fluid temperature ) T [ C] to 9 - to + Ambient temperature T [ C] to Operating pressure p [bar] Design details Design Drive : Highly efficient, maintenance-free wet rotor pump (glandless) Screw-ended High-efficiency electric motor with continuously variable differential pressure control Electronically commutated synchronous motor with permanent magnet rotor V - /6 Hz Thermal class F IP enclosure Temperature class TF 9 Interference emission EN - Interference immunity EN - BMS: IP enclosure Temperature class TF Interference emissions EN 6-6- Interference immunity EN 6-6- Bearings Product-lubricated special plain bearing Operating modes Automatic mode with constant-pressure or proportionalpressure control Fixed-speed operation with manual setpoint input BMS: Automatic mode with constant-pressure or proportionalpressure control, Eco Mode, Boost Mode ) To prevent condensation in the terminal box and stator, the fluid temperature must always be equal to or higher than the ambient temperature.

Building Services: Heating BMS Automatic functions Continuous output adjustment depending on the operating mode Maximum savings of operating costs by high-efficiency technology combined with speed control Soft start (limitation of starting current) Future-proof by maximum energy efficiency, exceeding future energy efficiency regulations such as ErP Full motor protection with integrated trip electronics Setback operation BMS: V with external differential pressure/speed setpoint External start/stop Simple to set with turn&press dial combined with an integrated display and symbols indicating the operating mode Integrated - V DC, External Start/Stop and general fault message functions New Eco Mode for additional savings of more than % compared with proportional-pressure control. General fault message Manual functions Thermal insulation shell included in scope of supply Setting the operating mode Setting the differential pressure setpoint Setting the speed level Certifications Overview Vent function Label Deblocking option BMS: Valid in: Europe Comment...- EEI....-6 EEI. /-6 BMS EEI. Germany All sizes Self-venting function Automatic deblocking function (pump starts at torque and current limitation with an unlimited number of start-up attempts) Signalling and display functions Alternating display of flow rate and electrical input power Error messages on the display Materials Overview of available materials Component Volute casing Shaft Impeller Bearing Bearing plate Can Thermal insulation shells Material BMS Grey cast iron with cathodic electrocoating Ceramics Stainless steel. Plastic with glass Plastic with glass fibre content (PA - fibre content (PSUGF ) GF) Ceramics Ceramics/carbon Stainless steel. Stainless steel. Polypropylene Product benefits Maximum savings of operating costs by high-efficiency technology combined with speed control Future-proof by maximum energy efficiency, exceeding future energy efficiency regulations such as ErP Easy to use with a combination of control keys, integrated display and symbols showing the operating status High availability by manual and integrated protective functions Compact dimensions and KSB plug make the pumps easy to install. Thermal insulation shell included in the scope of supply.

Selection information Minimum pressure The minimum pressure p min at the pump suction nozzle serves to avoid cavitation noises at an ambient temperature of + C and the indicated fluid temperature T max. The indicated values are applicable up to m above sea level. For installation at altitudes > m, an allowance of. bar / m must be added. Minimum pressure p min [bar] specified for the fluid temperature [ C] Calio Fluid temperature Minimum pressure [ C] [bar] S to 7, 76 to 9,8 S BMS to 8, 8 to 9, 6

Description of the characteristic curve H ~ VAC a) b) Q P a) b) Q Selection example Min. Fixed speed operation Max. Fixed speed operation Control range, settings in. m increments a) Control curve, maximum head b) Control curve, minimum head The characteristic curve can be adjusted between a) and b) by pressing the control keys. Programme overview / selection tables Features and functions Features and functions Functions Operating modes Feature BMS Δp-v for variable differential pressure Δp-c for constant differential pressure Fixed speed operation Eco Mode - Manual functions Setting the operating mode Setting the differential pressure setpoint Setting of speed level 7

Functions Feature BMS Vent plug - Deblocking option - Automatic functions Continuous output adjustment depending on mode (Δp control) Setback operation Soft start Integrated interfaces: - V DC, external start/stop, general fault (volt-free - relay contact) Signalling and display functions Error codes shown on display "System operational" message via additional module - - Alternating display of flow rate and electrical input power Technical data Selection table Connection PN P Piping Pump [W] Motor protection ) Signalling contacts ) Nominal current Mat. No. ~ VAC, /6 Hz [A] -- R ½ G, - -, -, 976. -6- R ½ G, - 7 -, -,8 976. -- R G ½, - -, -, 976. -6- R G ½, - 7 -, -,8 976. - R G ½, - -, -, 976.7-6 R G ½, - 7 -, -,8 977.7 - R ¼ G, - -, -, 978.7-6 R ¼ G, - 7 -, -,8 979.7-6 BMS R G ½ 8, -, -,8 97.6-6 BMS R ¼ G 8, -, -,8 98.8 [kg] ) Integrated motor protection ) General fault message relay and terminal pairs for - V input and external start/stop 8

Selection chart 6 US.gpm IM.gpm m - - - -6-6 -6-6 BMS -6 BMS [ft] ρ =. kg/m³ Q [m³/h] 6 7 8.. [l/s]..6.8....6.8.. (---(BMS)) - -6/ 9

Characteristic curves //- Δpv //- Δpc 6 8 Q [US.gpm] 6 8 Q [IM.gpm] ~ VAC R /,, / 6 8 Q [US.gpm] 6 8 Q [IM.gpm] ~ VAC R /,, /.. Q [m³/h]..... Q [l/s]..6... Q [m³/h]..... Q [l/s]..6....,m m,m m,m m......,m m,m m,m m...... Q [m³/h]... Calio_S_-/... Q [m³/h]... Calio_S_ -/ //- fixed speed operation Q [US.gpm] 6 8 6 8 Q [IM.gpm] ~ VAC R /,, /.. Q [m³/h]....... Q [l/s]..6.8.......... Q [m³/h]..... Stellerbetrieb_Calio_S_-/,, = speed level,,

//-6 Δpv Q [US.gpm] 6 Q [IM.gpm] 6 8 ~ VAC R /,, / //-6 Δpc Q [US.gpm] 6 Q [IM.gpm] 8 ~ VAC R /,, /.. Q [m³/h]........ Q [l/s]..6.8..6... Q [m³/h]........ Q [l/s]..6.8..6. m m m m,m m m m m,m.......... Q [m³/h]...... Calio_S_-6-Dpv/.... Q [m³/h]...... Calio_S_-6-Dpc/ //-6 fixed speed operation 7 6 Q [US.gpm] Q [IM.gpm] ~ VAC R /,, /..Q [m³/h]......... Q [l/s]..6.8...6........q [m³/h]....... Stellerbetrieb_Calio_S_-6/,, = speed level,,

BMS /-6 Δpv Q [US.gpm] Q [IM.gpm] ~ VAC R, / BMS /-6 Δpc Q [US.gpm] Q [IM.gpm] ~ VAC R, / Q [m³/h] 6 7.. Q [l/s]... Q [m³/h] 6 7 8.. Q [l/s].....8.6 % 8% 6% % % %..8.6 % 8% 6% % % %...... Q [m³/h] 6 7 Calio -6/... Q [m³/h] 6 7 8 Calio-6/ BMS /-6 fixed speed operation BMS /-6 Eco Mode 6 Q [US.gpm] Q [IM.gpm] ~ VAC R, / Q [US.gpm] Q [IM.gpm] ~ VAC R, / 6 7 8 9.. Q [m³/h] 6 8.. Q [l/s].... % % % % % 6% 7% 8% 9% %. Q [m³/h] 6 8 Boost-Mode -6 BMS/.. Total of speed levels can be set between stage "min" and "".....8.6.. Q [m³/h] 6 7.. Q [l/s].. % 8% 6% % % Q [m³/h] 6 7 Eco -Mode/ %..

Building Services: Heating Dimensions Scope of supply Pump Sealing elements Installation and operating manual 69 99 R/G Thermal insulation shells (for 8 mm overall length only) H H 6 6 H R/G BMS Dimensions [mm] Size -- -6- -- -6- - -6 - -6-6 BMS -6 BMS Rp / / / / / G / / / / / H 8 8 8 8 8 8 H - Installation information Permissible installation positions Sizes All

Lenntech info@lenntech.com Tel. +--6-9 www.lenntech.com Fax. +--66-89 7./6-EN 8..