Operation & Maintenance Manual

Similar documents
Operation & Maintenance Manual

Operation & Maintenance Manual

Operation & Maintenance Manual

Operation & Maintenance Manual

Operation & Maintenance Manual

Dry installed pump type LANDY BTP.

& AL RC-SERIES GB HSC 09-W13 Edition 5. T +31 (0) F +31 (0)

& AL RW-SERIES GB HSC 08-W36 Edition 4. T +31 (0) F +31 (0)

IM205 ITT. Wastewater. Vortex Series. Installation, Operation and Maintenance Instructions. Engineered for life

No: Revision Operation & maintenance manual. BRAVO SLURRY PUMPS

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Pneumatic actuator Assembly & maintenance procedures

Operating Instructions

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

MANUAL - PNEUMATIC ACTUATORS, SERIES DA & SR - 1 -

Heavy duty slurry pumps

VALIADIS S.A. HELLENIC MOTORS

IMPORTANT SAFETY NOTICE

Instruction Manual. * We reserve the right to amend specification without prior notice.

Heavy duty slurry pumps

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. * We reserve the right to amend specification without prior notice.

INSTRUCTION MANUAL (ATEX / IECEx)

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

PNEUMATIC ACTUATORS ASSEMBLY & MAINTENANCE PROCEDURES. Ref. Doc. MMMACTREGDRE English Rev.2 January 2012 ADA & ASR SERIES DOUBLE ACTING ACTUATOR ADA

INSTRUCTION MANUAL (ATEX / IECEx)

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

Ni-HARD SUBMERSIBLE PUMP

Submersible waste water pumps. Installation and operating instructions Series: DVV

Panelboards & Motor Starters

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Elmdene International Ltd

SE M.C.N.51D

DIAMOND POINT VIBRATING PROBES

WATERFLUX 3070 Quick Start

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

Operating Instructions

SUBMERSIBLE PUMP HSE RANGE

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

ILED Dorado. User Manual

Zone 1 Linear Range - Installation Guide

User manual Pipe notcher Type: AL 1-2E

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML

OPERATION & MAINTENANCE INSTRUCTIONS

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.

Explosion and flame-proof cast iron electric motors

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

PROCESS PUMPS (INDIA) PVT LTD

SUBMERSIBLE PUMP HSE RANGE

Operating Instructions

Submersible Sewage Pumps Type ABS XFP

Heating and Gas Installations - December 2014

our contribution for environmental protection Sealless magnetic coupled centrifugal pumps acc. to EN Type NML / NMB

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

OPERATION & MAINTENANCE INSTRUCTIONS

IQL Helios Area-/Streetlight. User Manual

Explosion and flame-proof single phase electric motors

SUBMERSIBLE WATER PUMP

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

Submersible Sewage Pumps Type ABS XFP

DC Master 24/ A

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

AE Installation Operation & Maintenance Instructions

Operating instructions ErgoPack 600 E

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

ABS submersible sewage pump AFP

Battery Charger. Series EASY Charger. User s manual

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Installation, Operation and Maintenance Manual

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

original operating manual Operating manual Translation of the Item-No.: ,

Operating Manual Includes Pumps: PG-9000 Part #R809606

Ex m Solenoid Operator Type 0519

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

HYDRAULIC PALLET TRUCK MODEL NO: PT540M/BM/CM & PT685BM/CM PART NO: , , , ,

Medium and high pressure pumps

MODEL H INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS. ASTRO HOIST Type E89-CTO

Operating instructions FPCC FPFG FPCG FPFX FPAC

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC.

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Grey Water and Condensate Pump. Rotex. Type Series Booklet

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

Volute Casing Centrifugal Pumps according to EN 22858, ISO 2858 with Magnetic Drive. Series CNH-M

Purging Air From Divider Block Lubrication Systems

Part-turn actuators SGExC 05.1 SGExC 12.1 AUMA NORM (without controls)

Transcription:

Operation & Maintenance Manual Submersible cutter pumps type DSP22 WETTERFRETTER 2.0 Explosion proof version Landustrie Sneek BV Tel. +31 515-486888 Pieter Zeemanstraat 6 Fax +31 515-412398 P. O. Box 199 info@landustrie.nl 8600 AD Sneek, Holland www.landustrie.nl Landustrie version 04-14 operation & maintenance manual DSP-Ex series 1 / 16

Contents: Foreword:... 3 Pump identification:... 3 Power supply:... 3 Usage limitations:... 3 General safety instructions before installation or maintenance:... 4 Environment:... 4 Installations:... 5 Hoisting device:... 6 Hoisting cable:... 6 Starting up:... 6 Noise level:... 7 Electrical pump start options:... 7 Water in oil detection:... 7 Spare parts:... 7 Cable connection direct start of the pump (DOL)... 8 Cable connections star-delta start of the pump (YD)... 8 Checkpoint first pump start:... 9 Special conditions for safe use... 9 Maintenance:... 10 Adjustment of the cutting mechanism:... 11 Special tool for removing the impeller:... 11 EC Declaration of conformity:... 12 Service Contract:... 12 Trouble shooting:... 13 Annex 1: Electrical pump data... 14 Annex 2: Pump denomination... 14 Notes:... 16 2 / 16

Foreword: This manual includes several warnings, installation guidelines and safety instructions. Before installation, please read carefully to avoid dangerous situations, which can lead to severe physical injury, and which could also damage the pump. The DSP22 cutter pump is typically designed to pump small quantities of waste water with high heads. Large solids are cut into small particles by triple blade rotating over a cutter plate The pump is equipped with a heavy duty Epoxy coating for long operational use. The pump is build in Flameproof version and might be used in a potentially explosive atmosphere, group II category 2 (zone 1). The DSP pumps are designed for professional use only. Only trained and skilled personnel may install, maintain and operate the pump. Pump identification: The main characteristics are given on the data plate, which is connected to the pump Code of Notified body 0344 (DEKRA) and Ex category are on the second data plate. Power supply: The power supply of the pump is part of the controls for the electrical installation. Please read carefully the specific user instructions of the electrical installation. These instructions, including the wiring diagram, are necessary for safe installation. Usage limitations: The DSP22 cutter pump is designed to pump normal sewage water. The cutting mechanism cuts long fibrous materials into small parts. The DSP22 pump in Explosion proof Version may be installed in potential explosive atmospheres, group II category 2 (zone 1) gas group IIB temperature class T4. In combination with frequency control temperature class T3 is valid. Pay attention to the right temperature and gas group classification, see EN 60079-0. Only use original spare parts to maintain the explosion safety! 3 / 16

General safety instructions before installation or maintenance: The following safety instructions should be followed up very carefully to avoid severe injury or damage. Before maintenance or inspection, both mechanical and electrical, always switch off the pump. Turn off the main power supply, log out and tag out according local procedures! Remove the fuses (if applied) and store them in a safe place. Switch off the emergency power supply if available. Alert other people with a clear warning to make aware of this service or maintenance operation. For servicing the pump, and replacing the oil to bring the pump into the horizontal position. This position is also needed to check the rotation of the pump. Be aware the recoil can be very powerful, don t go near rotating parts, or stand close to the pump when testing. Never put your hand into the pump if no safety measures are taken! When it is necessary to inspect the pump outside the sump, please close the cover of the pump sump, and take care about the following: Check carefully the power cable for bends and jamming. To avoid cable damage put a decent spacer between pump cover and the sump Never use the power cable to hoist the pump! Avoid any risk, that might damage the power supply cable. Always use safety shoes and safety gloves when handling the pump. Make sure all safety measures are comply the legal laws and provisions, such as the specific Labor Safety Instructions for confined spaces. Environment: Parts which will be replaced during repair, maintenance or renewal, could contain materials which may be harmful to the environment. Please be aware that some of the components can be very useful for recycling. The owner is responsible for careful disposal and processing of the materials. Do this in according to the local environmental regulations. 4 / 16

Installations: For the DSP22 pumps several installation options are possible. These options will be explained, with focus on specific points of attention. Installation BWK This installation represents a permanent submerged installation using the header coupling type BWK. min. level Points of attention: Ensure a good free passage under the pump. Adjust start- and stop levels in such a way that the motor will not make more than 20 starts per hour and so that the volute and seals are always submerged! The level regulation should be intrinsic save with safety level of a least SIL1. Check that the motor is adequately cooled. At full load conditions, at least 2/3 of the motor housing should be submerged. Installation OWK This installation represents a permanent submerged installation using the guide bar coupling type OWK.. min. level Points of attention: Ensure a good free passage under the pump. Check both the vertical and parallel position of the guide bar. The maximum tolerance for the vertical position is ± 3 o. The installation angle for the pump in case of installation or taking out is important. This angle (between pump and guide bar) is between 0 o and 5 o. The angle can be adjusted by changing the position of the hoisting cable. Adjust start- and stop levels in such a way that the motor will not make more than 20 starts per hour and so that the volute and seals are always submerged! The level regulation should be intrinsic save with safety level of a least SIL1. Check that the motor is adequately cooled. At full load conditions, at least 2/3 of the motor housing should be submerged. 5 / 16

Installation VRS This installation represents a permanent freestanding submerged installation. min. level Points of attention: Ensure a good free passage under the pump. Adjust start- and stop levels in such a way that the motor will not make more than 20 starts per hour and so that the volute and seals are always submerged! The level regulation should be intrinsic save with safety level of a least SIL1. Check that the motor is adequately cooled. At full load conditions, at least 2/3 of the motor housing should be submerged. Hoisting device: Submersible pumps can be hoisted out of the sump by means of an adequate lifting device. Landustrie is able to deliver this certified equipment. Hoisting cable: If applied, please replace the stainless steel hoisting cable every two years, or accordingly to local regulations. Starting up: Rotation control: The correct direction of rotation is counter clockwise (ccw), looking at the suction opening of the pump (see picture). Check procedure: Place the pump into horizontal position, start the pump short time, check visually the direction of rotation, Please follow all safety measures!. The correct direction of rotation can also be checked by observing the recoil of the pump during start up. Looking at the motor the recoil should be counter clockwise (ccw) Minimum water level: The pump should operate with sufficient cooling. This means that at least ⅔ of the motor is submerged. Reducing this minimum level means the motor runtime is limited to a maximum of 15 minutes, to avoid overheating. The cooling down time is at least twice the running time. 6 / 16

Noise level: In pump installations in sumps, with closed pump cover, the noise level will not exceed 70 db(a). Electrical pump start options: The different connections for the cables are specified on page 9. Check the cable type, installed on the pump and verify the data onto the pump data plate. The pump is equipped with extra leads for thermal protection. The thermal protection ensures that the pump under all conditions meet the needs of temperature class T4. Standard thermo-switches (Klixons) with 125 C switching temperature are supplied. Contact rating: max. 250V-1.6A. The contacts are normally closed. As an option thermistors (PTC) with 125 C switching temperature can be supplied. These are resistors, not circuit breakers! Resistance cold: 200-500 Ohm, Resistance at switching temperature: 1650-4000 Ohm Maximum voltage is 7.5 V. Resetting may only be done manually! The electrical connection of the permanently connected un terminated cable shall be made in a certified enclosure in type flameproof enclosure d or increased safety e. Water in oil detection: As a safeguard against water ingress into the motor, the pump can be equipped with a water detector in the oil housing. The water detector detects water which might have entered the oil housing due to seal failure or cable damage. The water detector causes the pump to switch off, before damage to the motor is done. Option one: Option two: cable cable entry electrodes Approved electrode Electrodes in the oil housing are connected to an intrinsic safe amplifier by means of a shielded cable or the kabel is connected through the pump cable. For ATEX for example the Vegator 132.AC.XXKBX and for example the IECEx Vegator 132.IC.XXKBX or equal. (See diagrams on page 8 and 9) We do strongly recommend to connect the pump to the mains by authorized personal only. Please ensure this is done accordingly and in compliance with local regulations. Spare parts: For ordering spare parts please contact your supplier. Parts list and sectional drawings are available on request. When ordering spare parts, please specify the following data: Pump type, product code, serial number. This information is available on the data plate on the pump. 7 / 16

Cable connection direct start of the pump (DOL) 1x 7 core cable To change direction of rotation BN GR BK GN/YE Brown Grey Black Green/ Yellow T1, T2 Klixons WA optional waterdetector L1,L2,L3 3 phase line Motor in delta Motor in star Cable connections star-delta start of the pump (YD) 1x 10 or 12 core cable To change direction of rotation GN/YE Green/ Yellow T1, T2 Klixons WA optional waterdetector L1,L2,L3 3 phase line 8 / 16

Checkpoint first pump start: Before installing and operating the pump following checkpoints are important: Check on delivery Remove the pump from the packing and check for transport damage, such as material errors, cracks or damaged cable. Check for completeness of the delivery. If the delivery is incomplete, or damaged, please contact your supplier immediately. Check oil level Verify the oil level in the seal housing Check Power supply. Verify if voltage, frequency and starting method are according to the data as specified on the pump data plate. Connect the pump according to the wiring diagram of the electrical cabinet. Information about the pump cable codes can be find on page 8 or 9. Thermal protection: Thermo-switches (klixons), the connection values for the standard thermal protection are max. 250V-1.6A. In cold condition the switch is closed. Thermistors (PTC), as an option thermistors can be supplied. Resistance cold: 200-500 Ohm, Resistance at switching temperature: 1650-4000 Ohm Cable entry: Especially when the pump has been stored for a long time, fasten the cable entry, if necessary, to tighten the rubber gland of the cable entry, the torque should be; G7/8 = 80-100 Nm. Motor protection: Verify the presence of the motor protection circuit breaker. At direct start (DOL) the motor circuit breaker should be set at the current value given on the data plate of the pump. At star delta start (YD) the setting of the motor circuit breaker should be 0.6 of the current value on the data plate of the pump. Special conditions for safe use Thermoswitches or PTC thermistors in combination with a protective device shall be installed in the motorcircuits in such a way that too high temperatures leads to switching-off of the motor. Thermal protection shall be connected! The resetting of the supply shall be manually! The level sensors must have a minimum safety integrity level SIL 1! The motors are provided with fasteners of at least property class A2-70 Contact the manufacturer for information on the dimensions of the flameproof joints 9 / 16

Maintenance: Before removing the pump from the installation, please switch off the mains, according to the instructions on page 4. Clean the pump adequately! Take care! The surface of the pump can be hot, especially just after switching off. Maintenance schedule: * After the first 100 operating hours: - Check the condition of the oil. If too much water is mixed with the oil, please contact your supplier. * Every 1000 operating hours or each year: - Check both the condition of the oil and the oil level. If too much water is included, please contact your supplier. - Change the oil if not transparent. Lubricants: The bearings of the pump are greased for life. Standard oil type for the mechanical seals: Shell Tellus 32, viscosity 32 cst. Oil quantity: 0.5l Cable entry: If the pump is stored for long time, the elasticity of the rubber gland might be diminished. This can lead to leakage to the motor compartment. By turning-in the cable entry clockwise, the sealing of the gland will be secured. Unscrew the 2 hexagon socket screws (1). Remove the cable clamp (2). Turn the hexagon head of the entry (3) clockwise, using A proper tool, so far that it is possible to place the cable clamp again. Screw-in the 2 hexagon socket screws (1). It is possible that your pump is equipped with an entry without a clamp. This depends on the used cable. Motor housing: Unscrew the inspection plug of the motor housing (1). Put the pump in horizontal position with the inspection opening downwards. If water is present this will come out this way. A small amount of water, due to condensation, is permissible. More water is an indication of leakage of the construction. Oil is an indication of seal failure between motor housing and oil chamber. If so, contact your dealer. 10 / 16

Oil level: Put the pump in a horizontal position so that the 2 hexagonal socket screws are on top. Unscrew the level plug (1) and the vent plug (2). The oil level should be at the lower side of the openings. By turning the pump a bit this should be visible. If not so fill up to the right level. Always use the right kind of oil! Adjustment of the cutting mechanism: The pump is supplied with a correctly adjusted cutting mechanism. The adjustment is realized with shims (4) between knife (2) and impeller (7). If due to wear the clearance between the knife and cutting disc is too large the clearance can be restored by adjusting the suction cover a bit. For this you can use the adjusting screws and bolts (1) If for inspection or renewal suction cover is removed, re-assembling must take place in the next sequence: 1. Fix the impeller, without knife (2), on the shaft with a temporary thrust ring and bolt. 2. Turn back the adjusting screws (1) into the suction cover (6). 3. Put the suction cover with cutting disc (5) in the pump casing, and push it down until it touches the impeller vanes. 4. Fasten the three connecting bolts (1b) by hand and unscrew them half a turn. 5. Fasten the three adjusting screws (1), to fix the suction cover. 6. Check that the impeller can rotate without much force. 7. Remove the temporary thrust ring and bolt, mount the knife (2) without key. Use shims (4) to correct the clearance (max. 0.15 mm.). 8. Remount the knife with key and check clearance again. Now the pump is operational again. Take care when removing or mounting the knife! Never stop the knife by hand! Use a tool that does not damage the sharp edges! Special tool for removing the impeller: Use special tool (see picture); Landustrie part no. 7G8437 to remove the impeller if necessary. 11 / 16

EC Declaration of conformity: Service Contract: Although the quality standards of the Landustrie pumps are very high, we do strongly recommend to close a service contract with your local supplier. For service- or technical information, please contact: 12 / 16

Trouble shooting: Make sure the mains are switched off during inspection. Only trained and authorized people may install and maintain the pump. Make sure the pump will not start unexpectedly. Don t go near to rotating parts of the pump Observe the local regulations for installation, maintenance and repair! Problem: Possible cause: Required action: Checkpoints: Pomp does not start No voltage on the terminals Check power supply * main switch * installation switches * all auxiliary switches * voltage relay Check motor protection * earth leakage relay * the auxiliary switches * motor protection relay * water in oil relais Check start- and stop signals * too low level * obstructed level switches * engaged emergency stop * general electrical error Wrong pump cable connection Measure cable wires * check motor phases Blockage impeller Check pump and/or impeller * impeller or pump jamming Pump does not stop No stop signal Check level switches * level switches * general electrical error Wrong start / stop signal Check level switches * installation switches * level switches * settings level switches Pump start and stops Fault in power supply Check power supply * main switch repeatedly * installation switches * switch thermal protection Level control system not stable Check level switches * installation switches * level switches * settings level switches Motor overload Check motor protection * wrong direction of rotation * impeller blockage * motor protection relay Motor current too high Supply failure Check power supply * voltage monitoring relay Pump failure Check pump * impeller blockage * medium specific gravity too high No flow or too low Jamming or airlock in discharge pipeline Check discharge pipeline * wrong direction of rotation pump capacity * blockage in discharge * valves half open or closed Pump failure Check pump * pump draws air * impeller blockage * impeller loose or damage Fault in power supply Check power supply * main switch * installation switches * switch thermal protection * impeller blockage High level alarm Pump failure Check pump Check power supply * impeller loose or damage * pump draws air * damaged bearings * switch thermal protection * fuses * level switches * settings level switches If the pump still fails please contact: 13 / 16

Annex 1: Electrical pump data Motor P1 electrical power speed cos phi maximum current [A] type 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz [kw] [kw] [rpm] [rpm] 220V 400V 690V 220V 460V 575V BB 2,1 2,4 2865 3350 0,91 0,91 6,1 3,3 1,9 7,2 3,4 2,8 BD 2,8 3,2 2830 3396 0,89 0,89 8,2 4,5 2,6 9,4 4,5 3,6 BE 3,5 4,0 2800 3360 0,91 0,90 10,1 5,6 3,3 11,6 5,6 4,4 BH 4,9 5,6 2840 3410 0,85 0,85 15,4 8,5 4,9 17,3 8,3 6,6 DA 0,9 1,1 1340 1700 0,79 0,78 3,1 1,7 1,0 3,7 1,8 1,4 Annex 2: Pump denomination Motor type Pump type BB DSP22-05BB DSP22-08BB BD DSP22-05BD DSP22-08BD BE DSP22-05BE DSP22-08BE BH DSP22-05BH DSP22-08BH DA DSP22-05DA DSP22-08DA 14 / 16

15 / 16

16 / 16