Record Plus. Molded Case Circuit Breaker Accessories. Plug In Base. DEH40915 Installation Instructions

Similar documents
EntelliGuard Power Circuit Breaker Accessories. Network Interlock for Ampere Circuit Breakers. Introduction. Operation

Introduction. Installation. A Series Lighting Control Panelboards. DEH41081 Installation Instructions

MicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers

Spectra Series Power Panelboards. General. Installation. Bolt-On Circuit Breaker Kits. DEH059 Installation Instructions

DEH g Installation Instruction for Cable Operator Mechanisms for SE150, SF250, SG600 & SK1200 Spectra RMS Circuit Breakers

A-Series II Panelboards AD/AE/AQ Type P & N Panel THQB Three-Phase Circuit Breaker Kits

Power Break II Circuit Breaker Accessories Motor Operator Mechanism

INSTALLATION INSTRUCTION Bollard Light 12V

DEH Installation

Spun Bay Installation Standard Version (non dimmable), Hook Mount

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Installation Instructions for TMQV Circuit Breakers and Molded Case Switches

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units

Operation and Maintenance Manual

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

A-Series II Panelboards AD/AE/AQ Type P & N Power Panel SE/TED Three-Phase Circuit Breaker Kits

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Wet Rated Batten LED Luminaire

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

SecoVac * Ground & Test Device

MOONRING 1.5 MOONRING 3

Installation Instructions

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

INSTALLATION INSTRUCTION

Captivate Illuminated Mirror Light

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

OWNER S MANUAL OM F

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers

n Ilation instructions Load Center Transfer TMOperator

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

3RB12. Betriebsanleitung Instructions. Bestell-Nr./Order No.: 3ZX1012-0RB12-1AA1 Ausgabe/Edition 01/2003. GWA 4NEB a

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Specification Grade Contemporary Wall Mount/Technical Installation Data

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

MODELS. 2 & 4 Low Profile Linears

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

MAXLITE RKT LED Retrofit Kit

Application guide. Tmax Link OEM UL 891 Switchboard Program

MODELS 2 & 4 Top Conduit Linears

Cable Cubby 1202 and 1402 Installation Guide

SECTION PANELBOARDS

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary.

Power Break Circuit Breakers

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Installation Instructions

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

GETTING STARTED WITH IN-WALL DIMMER SWITCH

Modular Metering Construction Details

100A 225A 400A PATENT PENDING

O & M Manual for the EATON Generator Ready Loadcenter

INSTALLATION DATA ETC SINGLE Stage

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician.

Programmer Disconnect Accessory Manual for Retrofil CB

Modular Metering Application Guide

F-Series. Circuit Breaker

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

F-Series. Circuit Breaker

ches UL File No. E101598

Design Standard. Purpose: Design Standard:

Installation Instructions

INSTALLATION INSTRUCTIONS AM rev. A

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

! WARNING I.L D WARNING GENERAL INFORMATION

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

Molded Case Circuit Breakers Section 6 Q-Line Circuit Breakers

WASP-P PRESSURE SENSOR

I. Pendant Mount Installation

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications.

Position Switch Kits Accessory Kits for EntelliGuard* Retrofill Circuit Breakers

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

poollux Power plx-pw60 & plx-pw100

Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches

Bussmann series Quik-Spec Power Module Switch elevator disconnect

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.


Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

Transcription:

DEH40915 Installation Instructions g Plug In Base Congratulations and thank you for choosing the Record Plus TM family of current-limiting circuit breakers. This UL-listed Plug-In Mounting Plate accessory kit is suitable for use with the FC circuit breaker series as illustrated in Figure 1. Record Plus circuit breakers are designed with a full line of integrated accessories. All units use the latest in integrated modular circuit breaker technology for flexibility in application and maximizing the product s utilization and capabilities. All Record Plus circuit breakers and the accessories are listed by Underwriters Laboratories to the UL489 standard and the CSA Standard C22.2, No. 5. These circuit breakers are certified to IEC60947-2. These accessories are also for use with our MAG- BREAK instantaneous trip-only circuit breakers, which meet the same standards and are ULrecognized components for use in motor applications. They can also be used with our molded case switches, which are listed per Underwriters Laboratories to the UL489 standard. Record Plus circuit breakers and their accessories are designed and manufactured to exceed our global customers high standards for reliability and quality. Record Plus Molded Case Circuit Breaker Accessories Figure 1. FC breaker mounted on Plug-In Base with Secondary Disconnect and Mounting Plate Warning: DANGER of Electrical shock or injury. Ensure ALL electrical power supplies are "OFF before installing or removing any devices. The breaker, trip unit or accessories MUST ONLY be installed and serviced by QUALIFIED personnel, see NEMA publication AB4. Avertissement: Danger contre les risques d'électrocutions. S'assurer avant toutes manipulations du disjoncteur que les différentes sources d'alimentation sont en position «OFF». Les disjoncteurs, unités de protection ou accessoires doivent être installés par des personnes qualifiées et habilitées. Lira NEMA publication AB4. Caution: This product is NOT suitable for use in equipment not specifically design to accept it. Contact equipment manufacturer for possible equipment modifications. Important: Cet appareil nedoit pas etre employe dans un equipement non specialement adapte a cet effet. Contactez le constructeur concernant les possibles modifications a apporter a l'equipemen

Product Description Plug-in bases provide the user with another option for quick change of breaker and switch assemblies without disturbing power connections. Two plug-in bases (one for each terminal end) are required for each protective device. Each plug-in base assembly contains the mounting hardware necessary to mount the base to either end of the circuit breaker. Electrical spacing between adjacent terminals is provided by alternate -- (LSL) or -- (SLS) terminal assemblies. These instructions describe the installation procedure for the plug-in accessory on Record Plus FC circuit breakers, as shown in Figure 1. The complete kits are available in the following catalog number variants: Catalog number FCDDF1 provides LSL Horizontal Catalog number FCDDF2 provides SLS Horizontal Catalog number FCDDF provides LSL Vertical Catalog number FCDDF4 provides SLS Vertical The parts supplied with this kit are listed in Table 1. Step 1- Unpack and inspect Unpack the Plug-In and inspect it for any shipping damage (insure the breaker accessory has the proper ampere, voltage ratings, wiring routing and operation for the application. In addition, attach appropriate labels to side of the breaker if internal accessories have been installed.). Item Description Qty PLUGIN BASE 1 SCREW # 10-2 X 0.625 INCH 2 Lock Washer 5 WASHER 5 4 MALE PLUG 5 SCREW # 10-24x1.75 INCH 2 6 PLUG-IN BASE ASM 1 7 NUT # 10-24 2 8 *MOUNTING PLATE (Optional) 1 *SECONDARY DISCONNECT KIT (Optional) (FCDSD) 9 SECONDARY DISCONNECT BOTTOM HALF (FCDSDP) 1 10 BREAKER ADAPTOR ASM (FCDSDB) 1 Horizontal Studs FCDDF1 (LSL) FCDDF4 (SLS) Vertical Studs FCDDF (LSL) FCDDF4 (SLS) Figure 2. Different Orientations of Strap. [10] [9] [1] [] [2] [4] [5] [6] Table 1: List of parts in the Plug-In base kit. * Items to be ordered separately. [8] Figure.Plugin Base Kit [7]

[14] Figure 4. Remove the lugs from breaker. [1] [] [2] Step 2- Installation 1. Remove the lugs from breaker (if installed), as illustrated in Figure 4. 2. Replace each lug with male plug (4) and fasten them to breaker terminal with # 10-2 X 0.625 screw [1] and lock washer [2] and flat washer [], as illustrated in Figure 5. Tighten the screws to 27-2 in-lb.. Fasten the Secondary Disconnect breaker adaptor (FCDSDB) [10] to the breaker base with #4-40 X 0.12 screw provided in kit, as illustrated in Figure 6. Tighten the screws to 5-6 in-lb. 4. Mount plug-in base (6) with #10-24x1.75 screw [5], nut [7], lock washer [2] and washer [] to proper support*, using the dimension shown in the table and drawing for location of boltholes, as illustrated in Figures 8 & 9. Tighten the screws to 2-28 in-lb. 5. Fasten the Secondary Disconnect Base (FCDSDP) [9] to proper support or Mounting plate [8] with thread cutting screw #8-2X0.75 provided in kit, as illustrated in Figure 7. Tighten the screws 16 to 20 inlb. NOTE: Use # 8-2 X 2.875 long screws to mount FC circuit breaker. If mounting screws other than those provided are used, threads must be class 2 and free of burs and deformation. *Optional Mounting plate [8], available and used for dead front panel construction, can also be used as templates in mounting plugin bases. [4] [9] FCDSDP Figure 5. Assemble Male Plugs to Breaker terminals. [6] FCDDF1 FCDDF2 FCDDF FCDDF4 [10] FCDSDB [8] Figure 6.Assemble the Secondary Disconnect Breaker Adaptor to Breaker. Figure 7.Assemble Plugin Base and Secondary Disconnect Bottom Holder on Mounting plate.

PROVISION FOR SECONDARY DISCONNECT (4) P BKR MTG HOLES PLUG IN BASE OUTLINE DIMENSIONS BREAKER TYPE FC A STUD ASSEMBLY B C Horizontal Stud Vertical Stud FCDDF1 FCDDF2 FCDDF FCDDF4 POLE AMP D 1.64 [41.6] E.75 [95.26] F.61 [91.8] Figure 8. Outline view of completed Plug-In installation. G J K L M N 5.54 [140.8] 0.51 [1] 0.87 [22] 0.59 [15] 0.28 [7.2] 0.187 [4.75] Table 2. Plug-In mounting Dimensions P #8-2 TAP R.54 [89.8] S 8.27 [210] NOTE: HORIZONTAL STUDS AS SHOWN. FOR VERTICAL STUDS, ROTATE CU STUDS 90 0,OTHERWISE SAME AS HORIZONTAL. T U V W X 5.2 [12.8] 4.98 [126.6] 0.94 [24] 1.1 [28.0] 2.2 [56] Z 2.6 [60.0]

Figure9.Drilling Plan for Mounting Panel PROVIDE THIS CUT OUT IF SECONDARY DISCONNECT IS USED [14] Step - Operation 1. With breaker in OFF position, install breaker by aligning male plugs with tulip connection and pressing firmly in place, as illustrated in Figure 10. 2. Connect the Secondary disconnect wires to the internal accessories mounted in the breaker.. Install the breaker on plug-in base as per FC breaker installation instruction [DEH4046]. Figure 8 is the outline view of completed installations with dimensions. Figure 9 illustrates the drilling plan for mounting panel. Figure 10.Breaker installation.

U These instructions do not cover all details or variations in equipment nor do they provide for every possible contingency that may be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise that are not covered sufficiently for the purchaser s purposes, the matter should be referred to the GE Company. The circuit breaker is a sealed unit that contains no user-serviceable parts. Tampering with the seal will void the warranty. g GE Consumer & Industrial General Electric Company 41 Woodford Ave., Plainville, CT 06062 www.geindustrial.com DEH40915 R0 1204 2004 General Electric Company