FLUORESCENT LAMPS FEATURES & BENEFITS ULTRA 8 LINEAR AND U-BEND LAMPS FOR GENERAL LIGHTING

Similar documents
Photo Z.Jedrus. High performance, energy-efficient linear fluorescent lamps. Philips T8 Collection

2 LED Designer Series

LED E-Series. we know light. LED Cents LED E-Series troffers gives you the appearance of fluorescent technology with a tube-like glow.

LED Flat Panel Luminaires

LED Flat Panel Luminaires

LED Flat Panel Luminaires

Philips MASTER LEDtube InstantFit Standard Output 1500mm

Solid State T8 tube is the smart alternative to a

HALOGEN PAR LAMPS FEATURES FEATURES & BENEFITS APPLICATIONS APPLICATIONS PAR 20, 30, 30 LONG NECK, & 38 FOR GENERAL LIGHTING

23585 F32T8/SP35/U/6 GE Mod-U-line Starcoat T8

Cynergy Series Retrofit Kit

Biax D and D/E. Compact Fluorescent Lamps Non-Integrated 10W, 13W, 18W and 26W. GE Lighting DATA SHEET. Product information.

SubstiTUBE IPS LED T8

e GE Ecolux Lamps LOW MERCURY, TCLP COMPLIANT LAMPS THAT FEATURE OUTSTANDING PERFORMANCE AND RELIABILITY

SEQUOIA KUMHO ELECTRIC USA, INC. New T8 Lamp Outlasts and Outperforms any T8 in the Market. Huge Energy Savings

ECO EXT (DIMMABLE)

Linear Fluorescent Lighting. Energy-Saving Lighting Systems

T5 Watt-Miser Linear Fluorescent lamps

Philips ALTO II Technology

Spiral T2 10,000 & 8,000 hours

Biax D and D/E. GE Lighting DATA SHEE T. Compact Fluorescent Lamps Non-Integrated 10W, 13W, 18W and 26W

T8 Tube Light. UL LISTED & cul LISTED & DLC LISTED. Germany Patent: Gebrauchsmusters / Nr

HOW IS LIGHT PRODUCED

LED FLEXIBLE LINEAR DL-FLEX-UP STATIC SERIES DL-FLEX-UP

LED Stairwell Fixture

LEDlescent TM T8 Ballast-Free Lamps

LED Indoor Lighting Product Guide


The characteristics of fluorescent lamps vary widely according to the lamp type. In general, fluorescent lamps have the following advantages:

FC12T9CW 32W T9 12" Cir-C-Line 60 Cri Cool White Fluor

Lighting Tables for Existing/Base Equipment 4/15/2011

TRUET5 EXT (DIMMABLE)

LIGHTING SPECIFICATIONS

SHP-S/SHP-TS Super SA SHP-TS 70W/CL E27 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

Specification Sheet: Uni-Fit T8 LED Tubes. Indoor. 177 Broad Street, 12th Floor, Stamford, CT T rvlti.com

Lumen Maint. (Hrs.) 2

ArcLine Recessed LED luminaire

1992 Energy Policy Act A Pacific Energy Center Factsheet

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

LED LINEAR TUBE AFFORDABLE

TCPHB4UNI1250K10 4' 12, 000 Lumen Unv Volt Led High Bay 5000K

L 36 W/840 XT. Product datasheet. LUMILUX XT T8 Tubular fluorescent lamps 26 mm, with G13 bases, long life

L 58 W/840. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

L 58 W/840. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

DESCRIPTION & APPLICATION

F32T8SPP41EC0CV 32W T8 48" 4100K Coated

L 36 W/840. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

Product datasheet L 18 W/840 XXT

Cruze Recessed LED luminaire

L 58 W/865. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

L 36 W/830. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

Super-high output LED high bay. Affordable replacement for up to 400W HID. RAIL RCLIGHTING.CA

HO 54 W/830. Product datasheet. LUMILUX T5 HO Tubular fluorescent lamps 16 mm, high output, with G5 base

DESIGNING A BETTER T8 LAMP

COMPACT FLUORESCENT. 83 Mini-Lynx Sticks. 86 Mini-Lynx Spirals. 88 Power-Lynx. 89 Mini-Lynx Classico. 90 Mini-Lynx Compact GLS

HSI-HX / HSI-THX SA HSI-THX 400W 4K E40 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

HO CONSTANT 39 W/840. Product datasheet. LUMILUX T5 HO CONSTANT Tubular fluorescent lamps 16 mm, high output, Constant

Steve Sindoni Commercial Engineer OSRAM Sylvania

L 30 W/840. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

Highbay Fluorescent - Six Lamp Low Profile Design

Lumen Maint. (Hrs.) 2

PRODUCT FAMILY DATASHEET OSRAM DULUX STICK

L 36 W/827. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

Fixture Spec Sheet HFA2 Series 4/15/2011

PRODUCT FAMILY DATASHEET OSRAM DULUX STICK

Lighting Tables for Existing/Base Equipment 4/15/2011

Average Retail Electricity Costs in North Carolina

HO 80 W/840. Product datasheet. LUMILUX T5 HO Tubular fluorescent lamps 16 mm, high output

Fixture Spec Sheet HFB3 Series 4/15/2011

LED LIGHTING LED LIGHTING. October 1 st Energy Into Action

23W Dimmable LED Bulb - 4' T8 Lamp Lumens - Double Ended- Replacement/Upgrade for Fluorescent

Be Off The Grid com Inc.

Symetrie LED Linear Lighting Solutions

Product datasheet L 18 W/840

Lighting Tables for New Equipment 2/24/2015

HE 14 W/827. Product datasheet. LUMILUX T5 HE Tubular fluorescent lamps 16 mm, high efficiency, with G5 base

LHBIP LED High Bay High Performance

PLUG-IN LAMPS SELF BALLASTED LAMPS PLUG-IN LAMPS WITH SEPARABLE ELECTROMAGNETIC ADAPTERS ACCESSORIES MISCELLANEOUS

FVT / LED Vapor Tight

Recessed. EvoKit LED Retrofit Kits Gen 3

PROJECT INFORMATION. Catalog No.

PRODUCT DATASHEET L 18 W/827

Highbay Fluorescent - Six Lamp Flat Profile Design

Lighting Tables for New Equipment 3/9/2016

Luminaires - LED High Bay

HO 24 W/840. Product datasheet. LUMILUX T5 HO Tubular fluorescent lamps 16 mm, high output

NIPPO Seamlessline LED PRODUCT LISTING

ICETRON ECOLOGIC Inductively Coupled Fluorescent System

2001 TMT Associates 1

Emerging Lighting Technologies IEEE - March 21, 2001

RLK SERIES Retrofit Lamp Kit for LED Tubes

INSTANT START BALLASTS

FR Series Premium Commercial LED Luminaire

56 Watt Vapor Proof LED 4 Foot Light for Outdoor Applications Lumens - IP67 Waterproof

HE 14 W/865. Product datasheet. LUMILUX T5 HE Tubular fluorescent lamps 16 mm, high efficiency, with G5 base

FROM YE OLDEN DAYS OF EFFICIENT LIGHTING TO TODAY S STANDARDS FOR EFFICIENCY. WE LL DISCUSS WHY EACH TECHNOLOGY WAS

LED Warehouse Industrial Lighting - 2 Ft Compact High Bay SPEC SHEET

COOLEDGE TILE TUNABLE WHITE - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces

Lighting Tables for Existing/Base Equipment 1/1/2014

Energy savings that inspires

Transcription:

Form No. S-UFLT8/UB/R-913 FLUORESCENT LAMPS ULTRA 8 LINEAR AND U-BEND SERIES ULTRA 8 LINEAR AND U-BEND LAMPS FOR GENERAL LIGHTING USHIO proudly carries a line of fluorescent lamps that include: Extended Life, Energy Saving and U-Bend series of lamps. Through technological advances and the highest grade components, T8 fluorescent lamps can save up to 4% on energy costs with no loss of light over older technology T12 lamp types. The USHIO Ultra 8 fluorescent series provides an economical as well as environmentally responsible alternative to standard T12 fluorescent lamps. The Ultra 8 lamps utilize protective coatings, effectively reducing the phosphor degradation while increasing lumen output. Advanced halophosphor and tri-phosphor coatings have also been added to increase the lumen stability and allow higher loading. (8 Series) Tri-Phosphor lamps render colors closer to that of nature. These lamps are most suitable for paint stores, retail shops, clothing boutiques, hair salons, printing businesses and graphic arts studios. (7 Series) Are applicable where color rendering is not of critical importance. These lamps are most suitable for office buildings, and manufacturing areas. FEATURES & BENEFITS Select lamps are TCLP Compliant Low mercury minimizes effects of lamp disposal on the environment Advanced technology saves up to 4% on energy costs over T12 lamps High Color Rendering Up to 86CRI Improved light distribution and quality Distributed by: Environmental asset Long life prevents the build up of discarded lamps which means less waste 213 USHIO America, Inc. All rights reserved.

EXTENDED LIFE ULTRA 8 LAMPS ULTRA 8 SERIES 32W EXTENDED LIFE ULTRA 8 T8 Lamps USHIO is proud to introduce the newest editions to its popular Ultra 8 linear fluorescent lamp family. Extended Life F32T8 lamps offer an average rated life up to 6, hours* without sacrificing efficient light output or high color rendering. These lamps are an excellent solution for applications where frequency of lamp changes and cost of ownership are significant factors. Additionally, they reduce mercury use per lumen-hour, which is an important calculation for LEED Green Building Certification. Available in multiple color temperatures: 35K, 41K, and 5K *When used on programmed start ballasts at 12 hrs per start. Ushio Ushio Dimensions Color Initial Average Avg Rated Life Watts Ordering Lamp MOL MOL Temp Lumens Rated Life* Programmed** (W) Code Description (mm) (in) (K) (lm) Instant Start (h) Rapid Start (h) Ultra 8 T8 Extended Life XL, Triphosphor 8 Series 1 32 3612 F32/T8/835XL Long Life E 1219 48 35 295 36* 4** 55* 6** 32 3611 F32/T8/841XL Long Life E 1219 48 41 295 36* 4** 55* 6** 32 361 F32/T8/85XL Long Life E 1219 48 5 285 36* 4** 5* 6** * Based on ANSI / IESNA standards of 3 hours per start Sold in Case Quantity only (25/case) 1 When using dimmers, dimming systems, or occupancy sensors, the lamp life will also be affected. The dimming system manufacturer can advise the affect of their system on lamp life. SPECTRAL DISTRIBUTION F32T8/835XL 1..8.6.4.2 4 45 5 55 6 65 7 75 F32T8/841XL F32T8/85XL 1. 1..8.8.6.6.4.4.2.2 4 45 5 55 6 65 7 75 4 45 5 55 6 65 7 75 See: www.lamprecycle.org or 1-8-895-8842

ENERGY SAVING ULTRA 8 LAMPS ULTRA 8 LINEAR & U-BEND SERIES 28W ENERGY SAVING ULTRA 8 T8 LAMPS Energy costs account for the majority of lighting expenses and that illustrates the critical need for high performance and energy efficient lamp products. The 28W Ultra 8 T8 lamps not only operate on high performance 28W ballasts they also provide the needed energy savings by directly replacing higher wattage 32W T8 lamps on Instant Start ballast systems. These tri-phosphor coated lamps provide the lumen stability and quality performance that goes hand-in-hand with dramatic energy savings (over 12% energy savings vs. standard 32W Ultra 8 lamps). MOL 6 in Ushio Ushio Dimensions Color Initial Average Commercial Watts Ordering Lamp MOL MOL Temp Lumens Rated Life* Life** (W) Code Description (mm) (in) (K) (lm) (h) (h) Ultra 8 8 Series 86CRI 1, 2 28 3484 F28T8/835 E 1219 48 35 28 24 3 28 3485 F28T8/841 E 1219 48 41 28 24 3 28 354 FB28T8/835 E 584 23 35 28 24 3 28 355 FB28T8/841 E 584 23 41 28 24 3 * Based on ANSI / IESNA standards of 3 hours per start T8 Sold in Case Quantity only (25/case) T8 U-Bend Sold in Case Quantity only (2/case) TCLP Compliant 1 When using dimmers, dimming systems, or occupancy sensors, the lamp life will also be affected. The dimming system manufacturer can advise the affect of their system on lamp life. 2 These lamps may operate on suitable energy saving 28W ballasts or instant start 32W electronic ballasts with a minimum starting voltage of 55V rms. The life ratings listed reflect operation on suitable 28W ballasts. Rated life for these lamps on 32W instant start ballasts are reduced by 25%. SPECTRAL DISTRIBUTION F28T8/835 F28T8/841 1. 1..8.6.4.2 4 45 5 5 5 6 65 7 75 4 45 5 5 5 6 65 7 75.8.6.4.2 See: www.lamprecycle.org or 1-8-895-8842

T8 LINEAR FLUORESCENT LAMPS ULTRA 8 T8 Bi-Pin G13 Base Universal Burn Position ULTRA 8 T8 SERIES MOL Ushio Ushio Dimensions Color Initial Average Commercial Watts Ordering Lamp MOL MOL Temp Lumens Rated Life* Life** (W) Code Description (mm) (in) (K) (lm) (h) (h) Ultra 8 Preheat 1, 3 15 381 F15T8WW 1 451 18 3 8 5 65 15 379 F15T8CW 1 451 18 42 875 5 65 15 38 F15T8D 1 451 18 65 76 5 65 Ultra 8 7 Series 2, 3 78 CRI 17 382 F17T8/73 61 24 3 1325 24 3 17 383 F17T8/735 61 24 35 1325 24 3 17 384 F17T8/741 61 24 41 1325 24 3 17 385 F17T8/75 61 24 5 1325 24 3 25 39 F25T8/73 915 36 3 2125 24 3 25 391 F25T8/735 915 36 35 2125 24 3 25 392 F25T8/741 915 36 41 2125 24 3 25 393 F25T8/75 915 36 5 2125 24 3 32 395 F32T8/73 E 1219 48 3 285 24 3 32 396 F32T8/735 E 1219 48 35 285 24 3 32 397 F32T8/741 E 1219 48 41 285 24 3 32 398 F32T8/75 E 1219 48 5 285 24 3 TCLP Compliant 1 These lamps are designed to operate on preheat ballasts. 2 Life ratings reflect operation on rapid start ballasts. Rated life for these lamps on instant start ballasts are reduced by 25%. 3 When using dimmers, dimming systems, or occupancy sensors, the lamp life will also be affected. The dimming system manufacturer can advise the affect of their system on lamp life. See: www.lamprecycle.org or 1-8-895-8842 *Based on ANSI / IESNA standards of 3 hours per start Sold in Case Quantity only (25/case)

CHARACTERISTICS & SPECIFICATIONS ULTRA 8 T8 Bi-Pin G13 Base Universal Burn Position MOL Ushio Ushio Dimensions Color Initial Average Commercial Watts Ordering Lamp MOL MOL Temp Lumens Rated Life* Life** (W) Code Description (mm) (in) (K) (lm) (h) (h) Ultra 8 Tri-phosphor 8 Series 2, 3 86 CRI 9 Series 2, 3 95 CRI 17 3231 F17T8/83 61 24 3 14 24 3 17 326 F17T8/835 61 24 35 14 24 3 17 3261 F17T8/841 61 24 41 14 24 3 17 3262 F17T8/85 61 24 5 14 24 3 25 3263 F25T8/83 915 36 3 225 24 3 25 3264 F25T8/835 915 36 35 225 24 3 25 3265 F25T8/841 915 36 41 225 24 3 25 3266 F25T8/85 915 36 5 225 24 3 32 399 F32T8/83 1219 48 3 35 24 3 E 32 31 F32T8/835 E 1219 48 35 35 24 3 E 32 311 F32T8/841 1219 48 41 35 24 3 32 312 F32T8/85 E 1219 48 5 35 24 3 32 3417 F32T8/96 1219 48 6 196 24 3 E 32 348 F32T8/841/HL E 1219 48 41 315 24 3 E 32 3524 F32T8/85/HL 1219 48 5 315 24 3 TCLP Compliant 2 Life ratings reflect operation on rapid start ballasts. Rated life for these lamps on instant start ballasts are reduced by 25%. 3 When using dimmers, dimming systems, or occupancy sensors, the lamp life will also be affected. The dimming system manufacturer can advise the affect of their system on lamp life. *Based on ANSI / IESNA standards of 3 hours per start Sold in Case Quantity only (25/case) See: www.lamprecycle.org or 1-8-895-8842

U-BEND T8 FLUORESCENT LAMPS ULTRA 8 U-BEND SERIES U-BEND T8 FLUORESCENT LAMPS FOR GENERAL LIGHTING USHIO s Ultra 8 U-Bend lamps are a match for 2 x 2 fixtures offering better optical efficiency than standard T12 lamp configurations. The Ultra 8 U-Bend lamps utilize protective coatings, effectively reducing the phosphor degradation while increasing lumen output. Advanced halophosphor and tri-phosphor coatings have also been added to increase the lumen stability and allow higher loading. USHIO Ultra 8 U-Bend lamps employ a precision engineered cathode guard, which prevents end darkening to insure maximum light output throughout the life of the lamp. Applications include: commercial and retail establishments, schools, general office and health care facilities. Available in 32W with a large variety of color temperatures ranging from 3K to 5K. FEATURES & BENEFITS High Color Rendering Up to 85CRI Precision engineered cathode guard prevents darkening throughout lamp life 6 inch leg spacing Improved light distribution and quality Environmental asset Long life prevents the build up of discarded lamps which means less waste Use with rapid start or instant start ballasts

PHOTOMETRICS ULTRA 8 T8 U-BEND Bi-Pin G13 Base Universal Burn Position 23 in 22.6 in 6 in 1. FB32T8/73/6 FB32T8/735/6 FB32T8/741/6 FB32T8/75/6 1. 1. 1..8.6.4.2.8.6.4.2.8.6.4.2.8.6.4.2 4 45 5 55 6 65 7 75 4 45 5 55 6 65 7 75 4 45 5 55 6 65 7 75 4 45 5 55 6 65 7 75 1. FB32T8/835/6 1. FB32T8/841/6 1. FB32T8/85/6.8.6.4.2.8.6.4.2 4 45 5 55 6 65 7 75 4 45 5 55 6 65 7 75 4 45 5 55 6 65 7 75.8.6.4.2 Ushio Ushio Color Initial Average Commercial Watts Ordering Lamp Code MOL MOL Temp CRI Lumens Rated Life* Life** (W) Code (mm) (in) (K) (lm) (h) (h) Dimensions Ultra 8 U-Bend 7 Series 32 3271 FB32T8/73/6 E 584 23 3 75 265 24, 3, 32 3272 FB32T8/735/6 E 584 23 35 75 265 24, 3, 32 3273 FB32T8/741/6 E 584 23 41 75 265 24, 3, 32 3274 FB32T8/75/6 E 584 23 5 75 265 24, 3, Ultra 8 U-Bend Tri-phosphor 8 Series for superior color rendering 32 3276 FB32T8/835/6 E 584 23 35 85 29 24, 3, 32 3277 FB32T8/841/6 E 584 23 41 85 29 24, 3, 32 3278 FB32T8/85/6 E 584 23 5 84 275 24, 3, These lamps are designed to operate on rapid start ballasts and the life ratings listed reflect this fact. Rated life for these lamps on instant start ballasts are reduced by 25%. When using dimmers, dimming systems, or occupancy sensors, the lamp life will also be affected. The dimming system manufacturer can advise the affect of their system on lamp life. *Based on ANSI / IESNA standards of 3 hours per start Sold in Case Quantity only (2/case) See: www.lamprecycle.org or 1-8-895-8842

CHARACTERISTICS & SPECIFICATIONS Scan with a smartphone to view this product online. Form No. S-UFLT8/UB/R-913 The specifications on this sheet supercede all previously published specifications and may be subject to change for design and specification improvement without prior notice.