SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

Similar documents
Series 740 Valves Pneumatic Directional Control (Pages from SC-Master2 catalog) The Drive & Control Company

MULTIPOSITION AIR CYLINDER

Type Flexair Pneumatic Pressure Control Valves

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

TYPE S RELAY VALVE (Volume booster) Service Manual

TYPE 740 VALVE. 4 Way / 2 & 3 Position Solenoid and Air Pilot Operated. Service Information

LOGIC VALVE DISASSEMBLY AND SERVICE REPAIR PROCEDURE

MULTIPOSITION AIR CYLINDER

THD-2-FM CONTROLAIR VALVE

C Linear Positioner (Small)

SUPERSPOOL II VALVE PNEUMATIC DIRECTIONAL CONTROL VALVE SERVICE INFORMATION

PNEUMATIC PIPING DEVICES Service Information

RCV-V PNEUMATIC DIRECTIONAL CONTROL VALVE

H-1 & H-1-A CONTROLAIR VALVE

AA Type Actuator Positioners

HC-2 CONTROLAIR VALVE

HD-2 CONTROLAIR VALVE

Lubricator Model PL08 with Variations and Accessories

P ROTAIR VALVE. Service Information WARNING: INSTALLATION AND MOUNTING

PowerMaster NFPA Pneumatic Cylinders Index

CERAM PNEUMATIC DIRECTIONAL CONTROL VALVE ISO 5599/1 SIZES 1-4

Ceram ISO Pneumatic Directional Control Valves

STC 2W Series Solenoid Valves

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Compressor Clutch Replacement Procedure

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

3V SERIES SOLENOID VALVE

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

MetroPrime 22MPC Self-Priming Centrifugal Pump

CRD600 Automatic Fitting Inserter

ES05 THE ESSENTIAL valve SYSTEM

CRD610 Automatic Fitting Inserter

Preassembled Clutch/Electrically Released Brake Module

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CERAM PNEUMATIC DIRECTIONAL CONTROL VALVE ISO 5599/1 SIZES 1-4

Product Information. 16 Series ROSS CONTROLS

Specification for Remanufacture Alstom Model 5 Switch Machine

HPx-JDx3-xx HARNESS INSTALLATION

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

GERINGHOFF. Corn Header Manual f HEADSIGHT.COM

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

Warner Electric UNIBRAKE Motor Brakes

STC 2L Series Solenoid Valves

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

4V130P-430P SERIES AIR PILOT VALVE

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

LEXION SINGLE FUNCTION HYDRAULIC VALVE KIT

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

HSIV PLOW OPERATOR S MANUAL

AGCO. Corn Header Manual d HEADSIGHT.COM

Parts Manual Vermeer/ McLaughlin V750 Vacuum Machine (Serial #7G G )

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

Compact Valves 16 Series

Preassembled Clutch/Brake Module

CRD400 Fitting Inserter OPERATIONS MANUAL

Parts Manual Vermeer/ McLaughlin Mud System 230P

ROSS CONTROLS. Compact Valves 16 Series.

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

2V1-3V1 SERIES SOLENOID VALVE

Power Float Manifold. Installation and Operations Manual Module 11A

Cleaning & Sanitizing Instructions

PPM EO-100 TM. Operation Manual

HD-2 CONTROLAIR VALVE

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Parts Manual Vermeer/ McLaughlin Mud System 230P

Reference Manual FM-200 Series

5 Gallon Tall Tea Dispenser 3 Gallon Tall Tea Dispenser TALL TEA DISPENSERS. Cleaning & Sanitizing Instructions

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

PVI 60KW, PVI 82KW, PVI 95KW

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

INSTRUCTIONS TUBULAR CONTROL ARMS & COIL-OVER CONVERSION FOR AMC MUSCLE CARS: 1970 AMX JAVELIN SPIRIT, HORNET, GREMLIN, CONCORD

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

PRO JACK 4500 ROLLING BRIDGE JACK 4,500 POUND CAPACITY. PARTS MANUAL P/n NRJ450BK

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

HP30 Slab Saw Owner s Manual and Operating Instructions

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

SOLUTION DISTRIBUTORS BOOK NO. IM AA UA

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

Electropneumatic Transducer

DRAGO. Corn Header Manual f HEADSIGHT.COM

SLAB SAW SERIES PARTS LIST

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

TB Series Brakes Tension Control System

Sensor technologies Proximity sensors Sensor mountings. Brochure

Air Curtain. Installation, Operating and Maintenance Instructions

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Model Number Structure

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

AGCO Conversion Manual a HEADSIGHT.COM

Transcription:

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

Specifications and features 4 Way / 2 & 3 Position Solenoid & Air Pilot Operated Diaphragm-Poppet Valve TECHNICAL DATA: Port Sizes: Integrated Fittings for 3/8, 5/16, and 8mm tubing Push-in fitting styles bodies available for metric tubing only (2 position only) Working Pressure: 20 PSI minimum 150 PSI maximum External Pilots not available Flow: C v=0.7 - with Integrated Fittings (C v=1.3 - comparable flow to threaded part valve) ELECTRICAL DATA: Standard Voltage (all coils are rated for continuous duty) Power Consumption Inrush Holding 24 VAC-50/60 Hz, 110V-50 Hz/120V-60 Hz 220V-50 Hz/240V 6.4 VA 3.7 VA 6, 12, 24 VDC 2.7 W Voltage Tolerance: +10% (Except for Explosion proof and Intrinsically safe solenoids.) NOTE: Electrical connectors must be ordered separately. One per solenoid required. See complete listing on Solenoid Connectors page. Recommended Tubing: Standard 3/8 O.D> x 0.062 wall - poly tubing *5/16 O.D. x 0.040 wall - nylon tubing *8mm x 1.00mm wall poly tubing *Requires optional tube nut kit (R432015289) Valves designed for 10mm O.D. x 1mm wall poly tubing are also available. Adapters available: 1/4 O.D. x 0.040 wall - poly tubing. Tube nuts are supplied with each valve for 3/8 x 0.062 wall poly tubing Features: NEMA 4 Electrical protection UL recognized & CSA approved coils version available Packaged as a cylinder/valve combination with TaskMaster cylinders sizes 1 1/2 thru 4. See catalog SC-200. Integrated fittings Adjustable built-in flow controls in R and S exhausts on two position valves Cycle life: 20 to 150 million cycles Response time for 24VDC single solenoid valve: (at supply pressure 85 psi) On (0-77 psi) 18ms or less Off (85-8 psi) 32 ms or less 52

Single and double solenoid, 5/2 NOTE: Electrical connector must be ordered separately. One per solenoid required, see Solenoid Connectors page. All valves on this page come with 3/8 tube nuts designed to accommodate 3/8 x 0.062 wall poly tubing. Valves with tube nuts for 5/16 (8mm) tubing, 10mm tubing, and push-in fitting style bodies available. NEW PART NO. OLD PART NO. VOLTAGE 5727495270 PW-067697-00001 110 VAC 50Hz/120 VAC 60Hz R432016655 PW-067697-00002 220 VAC 50Hz/240 VAC 60Hz R432016656 PW-067697-00003 6 VDC R432016657 PW-067697-00004 12 VDC 5727490220 PW-067697-00005 24 VDC R432016658 PW-067697-00006 24 VAC 50/60 Hz R432002436 without coil NEW PART NO. OLD PART NO. VOLTAGE R432016659 PW-067715-00001 110 VAC 50Hz/120 VAC 60Hz R432016660 PW-067715-00002 220 VAC 50Hz/240 VAC 60Hz R432016661 PW-067715-00003 6 VDC R432016662 PW-067715-00004 12 VDC R432016663 PW-067715-00005 24 VDC R432016664 PW-067715-00006 24 VAC 50/60 Hz R432002437 without coil Unique Manual Override Feature: Single solenoid valves are equipped with a convertible manual override button. Valve comes standard with extended locking override. By snipping tab off of plastic button, override becomes non-locking extended. By snipping button at first scored line, it becomes a flush non-locking override. By snipping at second scored line, a flush locking override is obtained, requiring a screwdriver to actuate. See next page for U.L. recognized and CSA approved coils. 53

Double solenoid 5/3 and U.L. recognized/csa approved models 4 Way / 3 Position, Double Solenoid Operated Diaphragm-Poppet Valve NOTE: Electrical connector must be ordered separately. One per solenoid required, see Solenoid Connectors page. All valves on this page come with 3/8 tube nuts designed to accommodate 3/8 x 0.062 wall poly tubing. NEW PART NO. OLD PART NO. DESCRIPTION SYMBOL CLOSED CENTER VERSION R432016670 PW-067717-00001 110 VAC 50 Hz/120 VAC 60 Hz R432016671 PW-067717-00002 220 VAC 50 Hz/240 VAC 60 Hz R432016672 PW-067717-00003 6 VDC R432016673 PW-067717-00004 12 VDC R432016674 PW-067717-00005 24 VDC R432016675 PW-067717-00006 24 VAC 50/60 Hz R432002438 without coil EXHAUST OPEN CENTER VERSION R432016665 PW-067716-00001 110 VAC 50 Hz/120VAC 60 Hz R432016666 PW-067716-00002 220 VAC 50 Hz/240 VAC 60 Hz R432016667 PW-067716-00004 12 VDC R432016668 PW-067716-00005 24 VDC R432006669 PW-067716-00006 24 VAC 50/60 Hz R432002439 without coil Warning: Do not energize both solenoids at same time or all ports may be pressurized or exhausted. 4 Way / 2 Position, Solenoid Operated Valves With U.L. Recognized & CSA Approved Coils PART NO. R432034081 R432034082 R432034083 R432034084 R432034085 R432034086 R432034087 R432034088 R432034089 R432034090 R432034091 R432034092 DESCRIPTION 5/2 Single Solenoid, w/ 12VDC 5/2 Single Solenoid, w/ 24VDC 5/2 Single Solenoid, w/ 110VAC 50/60Hz 5/2 Double Solenoid, w/ 12VDC 5/2 Double Solenoid, w/ 24VDC 5/2 Double Solenoid, w/ 110VAC 50/60Hz 5/3 Closed Center, w/ 12VDC 5/3 Closed Center, w/ 24VDC 5/3 Closed Center, w/ 110VAC 50/60Hz 5/3 Open Center, w/ 12VDC 5/3 Open Center, w/ 24VDC 5/3 Open Center, w/ 110VAC 50/60Hz These valves do not include solenoid connectors. Order one per solenoid. Dimensions are the same as our standard models. 54

Intrinsically safe solenoid valves, 5/2 Single Solenoid Model Part No. R432008894 (old no. P - 028044-00005) 55

Solenoid valves 5/2 with larger integrated fittings Standard Series 740 valve with tube nuts for 5/16 (0.040 wall) nylon tubing or 8mm (1mm wall) poly tubing. Push-in fittings are for 10mm (1mm wall) poly tubing. NOTE: Electrical connectors must be ordered separately. One per solenoid required, see Solenoid Connectors page. 2 Position, Standard fittings NEW PART NO. OLD PART NO. DESCRIPTION Single Solenoid R432016647 PW-027860-00001 110 VAC 50 Hz/120VAC 60 Hz Single Solenoid R432016648 PW-027860-00002 220 VAC 50 Hz/240VAC 60 Hz Single Solenoid R432016649 PW-027860-00005 24 VDC Single Solenoid R432016650 PW-027860-00006 24 VAC 50/60 Hz Single Solenoid NEW PART NO. OLD PART NO. DESCRIPTION Double Solenoid R432016651 PW-027897-00001 110 VAC 50 Hz/120VAC 60 Hz Double Solenoid R432016652 PW-027897-00002 220 VAC 50 Hz/240VAC 60 Hz Double Solenoid R432030385 PW-027897-00004 12 VDC Double Solenoid Single Solenoid Double Solenoid R432016653 PW-027897-00005 24 VDC Double Solenoid R432016654 PW-028797-00006 24 VAC 505/60 Hz Double Solenoid 2 Position, Push-in fittings (10mm O.D. tubing) NEW PART NO. OLD PART NO. DESCRIPTION 5727475280 572-747-528-0 220 VAC 50 Hz/240vac 60 Hz Single Solenoid 5727470220 572-747-022-0 24 VDC Single Solenoid 5727475302 572-747-530-2 Base Valve - No Solenoid* NEW PART NO. OLD PART NO. DESCRIPTION 5727485280 572-748-528-0 220 VAC 50 Hz/240vac 60 Hz Double Solenoid 5727480220 572-748-022-0 24 VDC Double Solenoid 5727485302 572-748-530-2 Base Valve - No Solenoid* * Base valves are supplied without coil(s) or connector(s) which must be ordered separately (see later page). Series 740 Valve with 10mm Supply and Delivery Ports for higher flow applications 2 Position Note: Use with 10mm O.D. x 1mm wall poly tubing NEW PART NO. OLD PART NO. DESCRIPTION R432015405 P -068700-K0000 Single Solenoid R432015410 P -068704-K0000 Double Solenoid 10mm Valves are supplied without coil(s) or connector(s) which must be ordered separately (see later page). 56

Extra corrosion resistant models 4 Way / 2 and 3 Position Solenoid Operated Corrosion Resistant Series 740 Valves All fasteners and exposed metallic parts for the 2-position valves are 300 series stainless steel. The adjustable built-in flow control adjustment screws for the 3-position valves are zinc plated carbon steel, with all other fasteners and exposed metallic parts 300 series stainless steel. These valves are recommended for most daily wash-down applications such as food processing, breweries and dairy plants, or anywhere else that corrosion can be a problem. Dimensions are the same as standard valves. CORROSION RESISTANT MODELS 2-POSITION VALVES Without Indicator Lights New Part Old Part Description Number Number R432015590 P -069294-00001 110VAC-50Hz/120VAC-60Hz Single Sol. R432015591 P -069294-00002 220VAC-50Hz/240VAC-60Hz Single Sol. R432015592 P -069294-00004 12 VDC Single Solenoid R432015593 P -069294-00005 24 VDC Single Solenoid R432015594 P -069294-00006 24 VAC-50/60Hz Single Solenoid R432015597 P -069297-00001 110VAC-50Hz/120VAC-60Hz Double Sol. R432015598 P -069297-00002 220VAC-50Hz/240VAC-60Hz Double Sol. R432015599 P -069297-00005 24 VDC Double Solenoid 2-POSITION VALVES With Indicator Lights New Part Old Part Description Number Number R432015613 P -069344-00001 110VAC-50Hz/120VAC-60Hz Single Sol. R432015614 P -069344-00004 12 VDC Single Solenoid R432015615 P -069344-00005 24 VDC Single Solenoid R432015616 P -069344-00006 24 VAC-50/60Hz Single Solenoid R432015617 P -069345-00001 110VAC-50Hz/120VAC-60Hz Double Sol. R432015618 P -069345-00002 220V-50Hz/240V-60Hz Double Solenoid R432015619 P -069345-00005 24 VDC Double Solenoid 3-POSITION VALVES Without Indicator Lights New Part Old Part Description Number Number R432008644 P -026564-00001 110VAC-50Hz/120VAC-60Hz Closed Ctr. R432008645 P -026564-00005 12 VDC Closed Center R432008862 P -027873-00001 110VAC-50Hz/120VAC-60Hz Open Center R432008863 P -027873-00005 12 VDC Exhaust Open Center 57

Air pilot, single and double Part No. R432013808 (old P - 067698-00000) Part No. R432013810 (old P - 067700-00000) Double Air Bleeder Valve: Part No. R432008442 (old P 026125-00000) 58

Manifolds and gang stacking Manifold Mounting, Snap-Together Assembly (Factory assembled manifolds also available) Gang Stacking Arrangement NEW PART NO. OLD PART NO. DESCRIPTION R432013811 *P -067701-00000 Inlet Segment R432013812 *P -067702-00000 End Segment R432013813 *P -067703-00000 Station Segment R432015880 *P -069881-00000 Single Subbase (Identical to inlet segment except rear cavities are blocked. Used to manifold mount one valve only. Part No. R432013853 O-Ring Kit (included with manifold segments) R432013852 O-Ring P/N 890701004 included with Segments. Lubricate O Rings with Dow Corning 55 before assembly. Manifold End Segment R432013812 Manifold Station Segment R432013813 Manifold Inlet Segment R432013811 59

Accessories ACCESSORIES R432015301 Elbow Fitting with nuts for 3/8 & 5/16 O.D. tubing R432015479 Reducer Elbow Fitting with nut for 1/4 O.D. (.040 wall) tubing R432015475 Reducer Fitting with nut For 1/4 O.D. tubing R432013850 Exhaust Tube Nut & Silencer (2 kits shown) 8919905502 (3/8, 5/16 or 8 mm) 8919905512 (10 mm) Blanking Cap (converts 4-way to 3-way) R432013852 Sheer Plug Knockout for Stacking R432015513 Exhaust Fitting Adapter Kit (converts the standard exhaust fitting to a tube fitting for external piping) R432015289 Tube Nuts (3 ea.) for 5/16 (.040 wall) O.D. nylon tubing or 8mm (1mm wall) O.D. poly tubing R432015287 Tube Nuts (3 ea.) for 3/8 O.D. (.062 wall) poly tubing R432015511 Manifold Blanking Plate (use to block one segment) R432015330 Manifold Bushing Kit for two supply pressures R432015512 Individual Manifold Supply Pressure Kit-mounts underneath manifold segment (not included) R432015527 Double Elbow Fitting for 1/4 O.D. tubing R432015526 Double Elbow Fitting for 3/8 & 5/16 O.D. tubing R432015525 Barb Fitting for 1/4 I.D. Reinforced Hose 60

Repair Kits Repair Kits and Parts Part No. Old Part No. Description R432013884 P -067916-00000 Single Solenoid Body Repair Kit R432013885 P -067917-00000 Double Solenoid Body Repair Kit (includes 3 position valves also) R432013854 P -067817-00000 Air Pilot Operator Kit R432013816 P -067705-K0000 Single Solenoid Body Assembly R432013814 P -067704-K0000 Double Solenoid Body Assembly R432015687 P -069541-00000 Solenoid Repair Kit, includes armature, plunger/spring & seal 8994702802 H -899470-02802 Solenoid Retainer Kit R432013839 P -067782-00000 Valve Latch & Spring R432013853 P -067816-00000 Valve Manifold Station "O" Ring Kit, (to attach valve to manifold) Solenoid Kits (Includes Armature, Coil, & Mtg. Hardware) Part No. Old Part No. Description R432015349 P -068648-00000 24 VAC-50/60Hz R432013840 P -067783-00000 110VAC-50Hz/120VAC-60Hz R432013841 P -067784-00000 220VAC-50Hz/240VAC-60Hz R432029180 P -067785-00000 6 VDC R432013842 P -067786-00000 12 VDC R432013843 P -067787-00000 24 VDC U.L. Recognized & C.S.A. Approved Coils Part No. Description R432034080 12 VDC R432009779 24 VDC R432009778 110 VAC-50/60Hz Standard Coils Part No. Model Number Description R432011985 P -048835-00001 110VAC-50Hz/120VAC-60Hz R432011986 P -048835-00002 220VAC-50Hz/240VAC-60Hz R432011988 P -048835-00004 12 VDC R432011989 P -048835-00005 24 VDC R432011990 P -048835-00006 24 VAC-50/60Hz Coils for Corrosion Resistant Valves Part No. Model Number Description 5428457072 H -542845-07072 110VAC-50Hz/120VAC-60Hz 5428457082 H -542845-07082 220VAC-50Hz/240VAC-60Hz 5420507012 H -542050-07012 12 VDC 5450507022 H -542050-07022 24 VDC 5428457022 H -542845-07022 24 VAC-50/60Hz 61

NOTICE TO PRODUCT USERS 1. WARNING: FLUID MEDIA AVENTICS pneumatic devices are designed and tested for use with filtered, clean, dry, chemical free air at pressures and temperatures within the specified limits of the device. For use with media other than air or for human life support systems, AVENTICS must be consulted. Hydraulic cylinders are designed for operation with filtered, clean, petroleum based hydraulic fluid; operation using fire-resistant or other special types of fluids may require special packing and seals. Consult the factory. 2. WARNING: MATERIAL COMPATIBILITY Damage to product seals or other parts caused by the use of noncompatible lubricants, oil additives or synthetic lubricants in the air system compressor or line lubrication devices voids the AVENTICS warranty and can result in product failure or other malfunction. See lubrication recommendations below. AIR LINE LUBRICANTS! In service higher than 18 cycles per minute or with continuous flow of air through the device, an air line lubricator is recommended.* (Do not use line lubrication with vacuum products.) However, the lubricator must be maintained since the oil will wash out the grease, and lack of lubrication will greatly shorten the life expectancy. The oils used in the lubricator must be compatible with the elastomers in the device. The elastomers are normally BUNA-N, NEOPRENE, VITON, SILICONE and HYTREL. AVENTICS recommends the use of only petroleum based oils without synthetic additives, and with an aniline point between 180 F and 210 F. COMPRESSOR LUBRICANTS! All compressors (with the exception of special "oil free" units) pass oil mist or vapor from the internal crankcase lubricating system through to the compressed air. Since even small amounts of non-compatible lubricants can cause severe seal deterioration (which could result in component and system failure) special care should be taken in selecting compatible compressor lubricants. 3. WARNING: INSTALLATION AND MOUNTING The user of these devices must conform to all applicable electrical, mechanical, piping and other codes in the installation, operation or repair of these devices. INSTALLATION! Do not attempt to install, operate or repair these devices without proper training in the technique of working on pneumatic or hydraulic systems and devices, unless under trained supervision. Compressed air and hydraulic systems contain high levels of stored energy. Do not attempt to connect, disconnect or repair these products when a system is under pressure. Always exhaust or drain the pressure from a system before performing any service work. Failure to do so can result in serious personal injury. MOUNTING! Devices should be mounted and positioned in such a manner that they cannot be accidentally operated. 4. WARNING: APPLICATION AND USE OF PRODUCTS The possibility does exist for any device or accessory to fail to operate properly through misuse, wear or malfunction. The user must consider these possibilities and should provide appropriate safe guards in the application or system design to prevent personal injury or property damage in the event of a malfunction. 5. WARNING: CONVERSION, MAINTENANCE AND REPAIR When a device is disassembled for conversion to a different configuration, maintenance or repair, the device must be tested for leakage and proper operation after being reassembled and prior to installation. MAINTENANCE AND REPAIR! Maintenance periods should be scheduled in accordance with frequency of use and working conditions. All AVENTICS products should provide a minimum of 1,000,000 cycles of maintenance free service when used and lubricated as recommended. However, these products should be visually inspected for defects and given an "in system" operating performance and leakage test once a year. Where devices require a major repair as a result of the one million cycles, one year, or routine inspection, the device must be disassembled, cleaned, inspected, parts replaced as required, rebuilt and tested for leakage and proper operation prior to installation. See individual catalogs for specific cycle life estimates. 6. PRODUCT CHANGES Product changes including specifications, features, designs and availability are subject to change at any time without notice. For critical dimensions or specifications, contact factory. *Many AVENTICS pneumatic valves and cylinders can operate with or without air line lubrication; see individual sales catalogs for details. -Refer to the appropriate service manual for parts and service information, most are available for download from www.aventics.com/us LIMITATIONS OF WARRANTIES & REMEDIES AVENTICS warrants its products sold by it to be free from defects in material and workmanship to the following: For twelve months after shipment AVENTICS will repair or replace (F.O.B. our works), at its option, any equipment which under normal conditions of use and service proves to be defective in material or workmanship at no charge to the purchaser. No charge will be made for labor with respect to defects covered by this Warranty, provided that the work is done by AVENTICS or any of its authorized service facilities. However, this Warranty does not cover expenses incurred in the removal and reinstallation of any product, nor any downtime incurred, whether or not proved defective. All repairs and replacement parts provided under this Warranty policy will assume the identity, for warranty purposes, of the part replaced, and the warranty on such replacement parts will expire when the warranty on the original part would have expired. Claims must be submitted within thirty days of the failure or be subject to rejection. This Warranty is not transferable beyond the first using purchaser. Specifically, excluded from this Warranty are failures caused by misuse, neglect, abuse, improper operation or filtration, extreme temperatures, or unauthorized service or parts. This Warranty also excludes the use of lubricants, fluids or air line additives that are not compatible with seals or diaphragms used in the products. This Warranty sets out the purchaser's exclusive remedies with respect to products covered by it, whether for negligence or otherwise. Neither, AVENTICS nor any of its affiliates will be liable for consequential or incidental damages or other losses or expenses incurred by reason of the use or sale of such products. Our liability (except as to title) arising out of the sale, use or operation of any product or parts, whether on warranty, contract or negligence (including claims for consequential or incidental damage) shall not in any event exceed the cost of replacing the defective products and, upon expiration of the warranted period as herein provided, all such liability is terminated. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHETHER FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE. No attempt to alter, amend or extend this Warranty shall be effective unless authorized in writing by an officer of AVENTICS Corporation. AVENTICS reserves the right to discontinue manufacture of any product, or change product materials, design or specifications without notice.

AVENTICS Corporation 1953 Mercer Road Lexington, KY 40514 Tel 859.254.8031 Fax 800.489.1488 www.aventics.com/us info.us@aventics.com AVENTICS Incorporated 5515 North Service Rd Suite #100 Burlington, Ontario L7L 6A6 Tel 905.332.0399 Fax 905.332.8596 www.aventics.com/ca info.ca@aventics.com Further contacts: www.aventics.com/en/contact The data specified only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Pages from SC-300/2015-02 online version. Subject to change. Printed in USA. AVENTICS Corporation This document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS. It may not be reproduced or given to third parties without its consent.