FIRE PUMPS & PACKAGED

Similar documents
Series 4600F. HSC Fire Pumps & Packaged Systems

900 Series Split Case Fire Pump Systems

Series 40MF. End Suction Fire Pumps & Packaged Systems

Horizontal Split Case Fire Pump Series 4600f 60 Hz

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

GROOVED END FLO-TREX COMBINATION VALVE

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

Peerless Pump FIRE PUMPS. Horizontal Split-Case, Vertical Turbine, In-Line and End Suction. Sterling Fluid Systems (USA), Inc.

Fire Pump Systems. For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need.

SINCE Double Suction Split Case Fire Pump. Series 4800 & (New Generation) 001-cat f

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

PRODUCT OF FIRE PUMPS SYSTEMS

Head - m. Flow - US gpm. Comments. Customer : Contact : Re Cotizacion Metro Linea 4 EDB Project : Quote No. :

Series Split Coupled Vertical In-Line Pumps. File no.: 43.10in Date: august 14, 2013 Supersedes: 43.10in Date:

Goulds Small Capacity Double Suction Pump

FIRE PUMP SYSTEMS. FIRE PUMP SINGAPORE PTE LTD No.8 Keng Chin Road #13-11 Cyan South Tower Singapore

Waterfall Pumps Manufacturing

Centrifugal End Suction Fire Pumps

Contents. Identification

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

Regenerative Turbine Pumps

340 Series Double Suction Split Case Pumps

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

ZPP and Z22 Double Suction Axially Split Single Stage Centrifugal Pumps

JOCKEY PUMPS MTH Tool Co. Series T41, T51, 150, 160 Regenerative Turbine Vane Type. TYPICAL SPECIFICATION MTH Tool Co. Series T41, T51 Pumps

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

F-Series Fire Fighting Pumps

Suction Guide & Flo-Trex Valve Series

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

PWA-IL B73.2 IN-LINE

Series SG & FTV. Suction Guides & Flo-Trex Valves

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

Fire Protection. FP-XA End Suction

Goulds API th Edition/ISO nd Edition API OH3 Overhung. Vertical In-Line with Bearing Frame. An ITT Brand

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Bristol: A History & Future.

Regenerative Turbine Pumps

University of Houston Master Construction Specifications Insert Project Name

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPP. Heavy Duty, Single Stage ANSI Chemical Process Pump

PWM. API 610 BB3 Multistage Pump

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

HORIZONTAL SPLIT CASING PUMP

PWM API 610 BB3 Multistage Pump

Series HSC-S Pumps Technical Brochure

Goulds High-Pressure Multi-Stage Pumps

PWM APi 610 BB3 Multistage Pump

Hydropak Booster Systems. Series motralec

EN. 850 Filtrate Pumps. Technical Specification Pages

Axially Split Case Pumps

PWD. PWD API 610 BB1 Single Stage Pump

Elite. KSB Australia Pty Ltd. Centrifugal Pump

FLHC SERIES DATA BOOKLET

TKL. Hydro-Titan Heavy Duty Back Pull-out Water & Process Liquid Pump. Experience In Motion

ZE/ZF Process Pump API 610

Six-Inch Submersible Pumps

Regenerative Turbine Pumps

H 2. O Series CENTRIFUGAL End-suction Pumps. Versatile, really robust and definitely reliable

390 Series Multi-Stage Vertical In-Line Centrifugal Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CRP. Chemical Centrifugal Pump Acc. to DIN EN ISO 2858 & DIN EN ISO 5199

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

D51 D61 D71 D91 Series

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

VSC /VSCS Pumps Technical Brochure

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

SUGGESTED SPECIFICATIONS

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

EFQT/EFQU. EBARA Self Priming Trash Pump. Contents Project: Model: Chk d: Date:

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

PROCESS PUMPS MODEL V200 ANSI B73.2

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

1100 Series Multi-Stage Vertical Turbine Pumps

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

PRODUCING TRUST IN FIRE AND SAFETY FIRE PUMP SYSTEMS A PRODUCT OF COMPLIANT.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

4500C Series Vortex Pumps

SM / SMI N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

HORIZONTAL SPLIT CASE SINGLE STAGE DOUBLE SUCTION Type AE CHECKING LIST

RS Multi-Stage, Ring Section Pumps

Dry installed end-suction pumps, LSN-series. according to ISO 2858 / ISO 5199

SERIES CS CLOSE COUPLED TURBINE PUMPS

F F F F F F. Foam Systems Deluge Systems Hydrant Systems Sprinkler Systems Hose Reel Systems Hose Rack Systems

CE Close-Coupled End Suction Pumps. Leading The Flow. TACO.

BBT/BBT-D Two Stage Radially Split Between Bearings Process Pump API 610, 9th Edition (ISO 13709)

FI / SFI Frame-Mounted End Suction Pumps

M50 L50 Series Multistage Regenerative Turbine Pumps

SECTION MOTOR REQUIREMENTS for HVAC

KS / SKS Vertical Split Coupled Inline Pumps

900 Series. 2000/2500 GPM High Head. Expanding our line to meet your needs. Model Latest Addition to the Aurora Fire Pump Line

SERIES CS CLOSE COUPLED TURBINE PUMPS

The e-nsc End Suction Pump Series

A-C Fire Pump. Fitting and Accessories A-C 100A

HYDRO-TITAN. Heavy duty back pullout water & process liquid pumps

SMN Double-Suction Axially Split Pump

SCE Heavy Duty, Single Stage, Overhung, API 610 Process Pump (OH2)

Volute Casing Pumps LSN. according to iso 2828 / iso Jansen Pompentechniek T: +31(0) E:

Transcription:

4600F Series HSC FIRE PUMPS & PACKAGED Systems FILE NO: 11-1 DATE: December 2004 SUPERSEDES: K13.110 DATE: April 1998

4600F Series Horizontal split case HSC fire pumps Armstrong Holden Brooke Pullen takes you back to the future with the Series 4600 Horizontal Split Case (HSC) Pump for HVAC and industrial applications. Introduction The Series 4600F, drawing on over 100 years of pump design expertise and leadership, is the state of the art in Horizontal Split Case pumps. It meets or exceeds the requirements of NFPA and testing laboratories involved in fire protection such as UL, ULC, and FM. The family of pumps capitalise on the Tilted Parting concept to minimize turbulence at the eye of the impeller by its straight laminar approach, thus maximizing efficiency. This also results in the lowest profile and minimum floor space of any HSC pump on the market today. The family was designed with commonality of parts, low installation cost, and ease of maintenance objectives. The pumps compact sizes are ideally suited for space saving packages and retrofit applications. With years of experience in package assembly for the fire protection industry, Armstrong can supply fire pump systems with all necessary accessories assembled and ready for site installation. GUARANTEED ADVANTAGES Installation time reduced Simplifies piping design Single source unit responsibility A complete package that will meet NFPA-20 requirements 2

Horizontal fire systems 14 Jockey Controller Fuel Tank 8 4 3 12 2 Fire Pump Controller 3 1 10 9 11 6 7 Fire Pump - Electric Driven 1. Pump/motor 2. Fire pump controller 3. Suction and discharge gauges 4. Air release valve 5. Casing relief valve (not shown) 6. Jockey pump 7. Common base Fire Pump - Diesel Engine Driven 1. Pump/engine assembled with cooling system fuel system battery system exhaust system 2. Fire pump controller 3. Suction and discharge gauges 4. Air release valve 6. Jockey pump 7. Common base Accessories - Additional (Electric or Diesel) 8. Suction OS&Y gate valve 9. Discharge butterfly valve 10. Silent check valve 11. Test tee Accessories - Special for Diesel 12. Main relief valve 13. Enclosed cone (not shown) Special Mounting Features 14. By-pass line city by-pass with check valve flow meter by-pass (not shown) Key Features common to Electric and Diesel Accessories - (Electric or Diesel) Accessories - Special for Diesel Special Mounting Features 3

4600F Series Horizontal Split Case HSC Fire Pump - Truly Superior Recirculation: External water seal ring recirculation lines Coupling: Flexible coupling Optional 3 1 /2 full spacer coupling available Stuffing Box Housing Self-contained combination bearing & seal housing Permits packing changeout without having to be removed Drip Containment: Fitted with drain connection Casing Wear Ring: Replaceable case wear rings Locked to prevent rotation or axial displacement Impeller wear ring available as an option Pump Casing Designed to withstand the high pressure requirement typical in fire protection 4

Impeller: Hydraulically balanced double suction Dynamically balanced Minimum axial thrust High efficiency throughout operating range Shaft Sealing with Packing: Three-piece split gland standard Packing replaceable without disturbing wetted parts Stuffing box extension designed for easy access Shaft Sleeves Replaceable bronze sleeves Protects shaft throughout stuffing box Bearings: Easy removal with bearing nut Sealed, permanently greased bearings for extended life Low friction loss bearing Maintenance free Bearing Housing: Removable without removing top casing Tilted Parting Design Casing: Permits laminar approach to eye of impeller Lower NPSH required Lower pump profile Minimum pump footprint Removable rotating element without disturbing piping Low foot-mounted casing to reduce vibrations 15 Angle Casing Shaft: Minimum deflection for long bearing life Minimum vibrations Identical shaft and parts for left and right hand drives Suction and discharge on same centerline Equal distance from pump centerline to suction and discharge flanges 5

Fire pump coverage chart Electrical 60 Hz Rated Capacity (L/min) 1890 2850 3800 4750 5700 7600 9500 11400 13300 Rated Head (psi) 250 200 150 6 X 5 X 10 6 X 5 X 12.5 6 X 5 X 10 8 X 6 X 12.5 8 X 6 X 12.5 8 X 6 X 10 8 X 6 X 10 10 X 8 X 11 10 X 8 X 11 1750 1500 1250 1000 Rated Head (kpa) 100 5 X 4 X 10 5 X 4 X 10 8 X 6 X 15 12 X 10 X 15 12 X 10 X 15 750 500 50 6 X 5 X 12.5 6 X 5 X 12.5 8 X 6 X 12.5 8 X 6 X 12.5 12 X 10 X 12.5 12 X 10 X 12.5 275 500 750 1000 1250 1500 2000 2500 3000 3500 Rated Capacity (USGPM) Key 1750 rpm 3550 rpm Note: Higher ranges may be available for diesel driven applications 6

Rated Head (psi) Fire pump coverage chart Electrical 50 Hz 250 200 150 100 50 Key 2900 rpm 12 X 10 X 15 12 X 10 X 12.5 12 X 10 X 15 12 X 10 X 12.5 500 750 1000 1250 1500 2000 2500 3000 3500 Rated Capacity (USGPM) Rated Capacity (L/min) 1890 2850 3800 4750 5700 7600 9500 11400 13200 5 X 4 X 10 6 X 5 X 10 6 X 5 X 12.5 6 X 5 X 10 6 X 5 X 10 6 X 5 X 10 8 X 6 X 12.5 8 X 6 X 10 8 X 6 X 12.5 8 X 6 X 10 Note: Higher ranges may be available for diesel driven applications 10 X 8 X 11 10 X 8 X 11 1750 1500 1250 1000 750 500 275 Rated Head (kpa) 7

Typical Specifications Supply and install as indicated on plans one (1) fire pump system consisting of: 1. Pump One Armstrong Darling, 4600F Series, Size double suction horizontal split case fire pump listed by Underwriters Laboratories of Canada (ULC), Underwriters Laboratories Inc. (UL) and approved by Factory Mutual (FM) having a capacity of USGPM for a pressure boost of PSIG. Suction pressure PSIG. Pump casing shall be of cast iron, axially split with a 15 angle that will minimize NPSH requirements and dimensions. Lower half shall contain suction and discharge nozzles. Suction and discharge connections shall be on the same elevation. Top half and rotating element shall be removable without disturbing the piping. Casing shall be fitted with replaceable bronze wearing rings. Impeller shall be bronze, double suction, enclosed type fully balanced and keyed to an alloy steel shaft. Shaft shall to be fitted with replaceable bronze sleeves. Shaft shall be mounted in two dust tight deep grooves, sealed, and permanently greased ball bearings. Bearings shall be mounted in cartridge type housing so that they shall be replaceable without opening pump casing. Bearings shall be easily removable by rotating bearing removal nut. No special tools or bearing puller are to be necessary. Each stuffing box shall be fitted with a three piece bronze gland. Stuffing box shall be fitted with a stuffing box extension to facilitate the packing rings removal. Packing rings shall be removable without disturbing wetted parts or the pump bearings. Water seal rings made from non-corroding material shall be piped to pump volute. 2. Electric Motor The fire pump shall be directly coupled through flexible coupling to a horizontal electric motor with a maximum HP of at RPM, VOLT, PHASE CYCLE. Motor shall be open drip proof, standard efficiency with 1.15 service factor. 3. Minimum Fittings The pump shall be supplied with the following accessories: One (1) combination suction gauge 3-1 /2 dial type with 1 /4 cock and lever handle. One (1) air release valve. One (1) discharge gauge, 3-1 /2 dial type, with 1 /4 cock and lever handle. One (1) casing pressure relief valve. 4. Other Accessories Pump shall be fitted with one (1) eccentric suction reducer and one (1) concentric discharge increaser (by mechanical contractor) to fit NFPA20 recommended piping sizes. One (1) outside test header shall be supplied with one (1) set of x 2 1 /2 hose valves with caps and chains. 5. Fire Pump Controller The fire pump controller shall be specifically approved for fire pump service by ULC, UL or FM. The controller shall be of the combined manual and automatic stop, starting method, Model as manufactured by. All equipment shall be enclosed in approved drip proof enclosure. The control equipment shall be completely assembled, wired and tested at point of manufacture prior to shipment. Circuit breaker shall have an interrupting capacity of kamps or a withstand rating of kamps RMS. Water pressure switch shall be suitable for PSI working pressure. 5a. Fire Pump Controller and Automatic Transfer Switch Combination The automatic transfer switch controller combination shall be approved by UL, ULC or FM, Model. The automatic transfer switch and the pump controller shall each be mounted in separate enclosure, mechanically attached to form one unit and provide for protected interlock wiring. The automatic transfer switch shall be capable of automatic power transfer from normal to alternate (generator / second utility) emergency power source in case of normal supply failure and automatically re-transfer after restoration of normal power conditions. 6. Jockey Pump The jockey pump shall be manufactured by Model No. for a capacity of USGPM and a pressure boost of PSIG. The jockey pump shall be driven by an open drip proof electric motor of HP RPM VOLT PHASE CYCLE. 7. Jockey Pump Controller The jockey pump shall be controlled by an automatic jockey pump controller model with full voltage starter. 8. Mounting and Testing The pump shall be suitable for a maximum working pressure of. Pump shall be hydrostatically tested at twice the maximum working pressure for at least 5 minutes. The pump shall be performance tested at rated speed. The pump shall furnish not less than 150% of rated capacity at a pressure not less than 65% of rated head. The shut-off total head of the pump should not exceed 140% of total rated head. A certified test curve, indicating the flow, head, power and efficiency shall be supplied. The fire pump and electric motor shall be base mounted and aligned at the pump manufacturer s factory. Final alignment shall be made after installation on site. Please refer to Armstrong Holden Brooke Pullen Fire Pump Catalogue for Diesel Driven Typical Specifications. Our policy is one of continuous improvement and we reserve the right to alter our dimensions and specifications without notice Experience Building... Export Sales Peartree Road, Stanway Colchester, Essex United Kingdom, C03 0LP T +44 (0)1206 579491 F +44 (0)1206 760532 E export@armlink.com UK HVAC Sales North Wenlock Way Manchester United Kingdom, M12 5JL T +44 (0) 1612 232223 F +44 (0) 1612 209660 E salesuk@armlink.com UK HVAC Sales South/Service 21-23 Ormside Way Holmethorpe Industrial Estate Redhill, Surrey, RH1 2NT T +44 (0) 1737 378100 F +44 (0) 1737 378140 E salesuk@armlink.com For Armstrong locations worldwide, please visit www.armstrongpumps.com