Installation Instructions: Read these instructions in its entirety before performing any installation work.

Similar documents
Installation Instructions: Read these instructions in its entirety before performing any installation work.

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

poollux Power plx-pw60 & plx-pw100

Warning. 1. Have the installation done by a qualified professional, according to local electrical codes. 1. It may not cause harmful interference,

AquaPure Ei TM Series Replacement Kits

Warning. 1. Have the installation done by a qualified professional, according to local electrical codes. 1. It may not cause harmful interference,

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IntelliTouch Expansion Center Kit

Electric Range installation manual

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation Instructions: ACCENT SYSTEM

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

Model Numbers SAVI-NOTE75, SAVI-NOTE150

MAGICBOWL WATER EFFECT WITH FIREFX LED LIGHT FOR POOL AND SPA

Installation Manual. CS9300 Professional Series Landscape Lighting System

I n s t a l l a t i o n M a n u a l. f o r T E D

WARNING. Important Notice

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0

Installing Power Components

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Electric Vehicle Charging Station

IntelliTouch Pool and Spa Control System Load Center and Power Center

INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

Lumination TM LED Luminaire LUR Series

FLO Home TM G5 Model. Installation guide

A B C D E F. Tools Required (supplied by others)

Underwater Pool Color-Changing LED Light

Owner s Manual POWER SOLUTION. AUTOMATIC CIRCUIT SWITCH. JTB Manufacturing, Inc. Part No Manufacture Date Year: 2013 Month:

POOL BARON Nicheless Color Changing LED Pool Light

Lumination TM LED Luminaires LAL Series - Continuous Run Option

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved.

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

- Wiring Brochure Zone Manager 335

- Wiring Brochure Zone Manager 336

6. Electrical. 7. Settings. 8. Quick

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

PART B BRAND SPECIFIC MANUAL

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N )

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

V-DW2425A / V-DW2440 and V-DW11025A / V-DW11040A

PVM 220 Installation Guide

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

INTELLIBRITE 5G COLOR POOL AND SPA LIGHTS

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

REVERIE ADJUSTABLE BED OWNER S MANUAL. Reverie Deluxe Adjustable Bed. Copyright All Rights Reserved. Manual Part No.

Easy-On Wireless Tail Lights User s Guide

HERCULES II DC OWNER S MANUAL HERCULES II DC RESIDENTIAL & COMMERCIAL

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

PVM 220 Installation Guide

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

Power and Cooling. Chassis Power System

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Installation Instructions: HYPERION R-Lite SYSTEM

Wireless Remote System RC-12v & 24v Standard RF Remote Control System INSTALLATION MANUAL AND OWNERS GUIDE Table of Contents:

ALUMAREEL. Electrical Cord Reel. Model EC6 100 Model EC Operational, Maintenance and Installation Manual

INTELLIBRITE 5G WHITE AND COLOR POOL AND SPA LIGHTS

MaxLite StaxMax LED Flood Lights

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Transfer Switch TS-50. Owner s Manual

V-D2425 and V-D2440 Digital Clock

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

SURFACE TRACK (120/250V) SPECIFICATIONS

Parkit360 Transformer

WF-5110R True Sine Wave Inverter

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

MIC210 Electric Farm Conversion Instructions

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

Installation Instruction

DOOR LIMITS A) ENGAGE CHAIN/BELT CONNECTOR TO CARRIAGE CAUTION B) CLOSE TRAVEL LIMIT

Horticulture Batten LED Luminaire

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

LED Recessed Troffer Retrofit Kit

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

LT Charging Cart for Laptops

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Remote Start System OWNER S MANUAL. Mazda CX-9

Operators Manual. True RMS Voltstik. Radio Linked Multiple Reading Voltmeter. SensorLink

Table Of Contents. Motor Selection Guide Installation Instructions Operators 20-32

1329I Integrated Drive/Motor CE Filter Option Kit

Transient Fault Location for Branch Circuit Breakers TFT Turquoise Circle Newbury Park, CA Toll Free:

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

EMERY SKY SUSPENDED LED LUMINAIRE

FLO Home TM X5 Model. Installation Guide

BRILLIANT WONDERS 1.5" LED LIGHT

Transcription:

WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL LISTED Conforms to UL STD 379; Certified to CSA STD C22.2 #218.1 4008814 79-15204-00 REV.A4 http://www.srsmith.com Page 1 of 8

Accessory Item: WE-65 65 ft Repeater Cord Extension Kit 79-15204-00 REV.A4 http://www.srsmith.com Page 2 of 8

SAVE THESE INSTRUCTIONS! IMPORTANT SAFETY INFORMATION Basic safety precautions should be observed when operating the WIR-TRAN product and other associated equipment. 1. A qualified electrician must install the WIR-TRAN in accordance to the National and Local Electrical Codes. 2. The WIR-TRAN must not be less then 5 feet (3 meters in Canada) from inside edge of pool. ONLY USE COPPER CONDUCTORS. 3. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors. 4. For the bonding, grounding, installing, and wiring of underwater lights to the WIR-TRAN refer to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code. 5. This device should never operate equipment that could cause property damage, bodily injury, or death should it be activated unexpectedly. 6. Never allow children to operate the WIR-TRAN unsupervised. FCC WARNING 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by S.R. Smith could void the user's authority to operate the equipment. ELECTRICAL RATINGS Do not exceed the maximum electrical ratings of the WIR-TRAN. Install a 20Amp 120VAC GFCI Circuit Breaker for light input. Refer to pages 4 and 5 for installation instructions. Light circuit is rated for 2.5Amp 12VAC Max. 79-15204-00 REV.A4 http://www.srsmith.com Page 3 of 8

` WARNING TURN OFF INCOMING POWER BEFORE SERVICING EQUIPMENT. ALL INSTALLATION AND MAINTENANCE WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL PERSONEL ONLY. GFCI BREAKER MUST BE USED TO CONNECT WIR-TRAN TO INPUT POWER. VERIFY ALL ELECTRICAL RATINGS BEFORE INSTALLATION IS COMPLETE. LOCATION Install the WIR-TRAN enclosure using the mounting plates included with each enclosure. The WIR-TRAN is housed in a Type 3R rainproof enclosure and can be mounted anywhere between the pool equipment and the breaker panel. WIRING INSTRUCTIONS FOLLOW PROPER WIRING PRACTICES IN ACCORDANCE WITH ALL LOCAL REGULATORY REQUIREMENTS. Power Connections: To wire the WIR-TRAN use insulated COPPER wire only, 12 gauge minimum. Run a ½ to ¾ conduit from the main breaker panel to the right most bottom conduit knock out of the WIR-TRAN. Pull appropriate wires from the main breaker panel to the WIR-TRAN unit. To make power connections unscrew the Isolation Cover attachment screw and remove 3/8 inches of insulation from wire ends. Insert the bare end of wires under the pressure plate of terminals (Power Input 120V AC, NEUTRAL). Use 1/8-in. flat head screwdriver to tighten terminal screws firmly (10.0 in-lbs minimum). Connect the house ground line to the Input Ground line on the WIR-TRAN. Install a 20 Amp max GFCI circuit breaker in the main breaker panel and connect the HOT wires from the WIR-TRAN. As a final step replace the Isolation Cover over the Input wire terminals and reattach the grounding attachment screw. Use provided cable tie to secure the Input Wires to the cover. GFCI NEUTRAL FROM GFCI LOAD 120V POWER FROM GFCI LOAD GROUND NEUTRAL 120V LINE INPUT 79-15204-00 REV.A4 http://www.srsmith.com Page 4 of 8

Hooking up 12VAC Light to Circuit 1 To connect a 12VAC light to the Circuit 1 switch, pull wires from the low voltage lighting product to the WIR-TRAN through conduits connected to the left bottom of the WIR-TRAN. Some lights may identify a 12VAC Hot and Neutral lead though this is not typical with 12VAC low voltage lighting. If it does identity specific leads, then follow the below instructions, otherwise it doesn t matter as long as both 12VAC leads are connected to the 12VAC POWER OUTPUT terminals and 30W demand is not exceeded. As illustrated, connect the light that will be operated by the Rocker Switch to the Light Hot terminal. Connect the Neutral to the Light Neutral terminal. Do not exceed demand of 30 watts @ 12V. LIGHT NEUTRAL LIGHT HOT 79-15204-00 REV.A4 http://www.srsmith.com Page 5 of 8

Repeater Mounting The WIR-TRAN is equipped with a signal repeater that can be mounted up to 10 feet from the WIR-TRAN unit. This repeater receives signals from the wireless remote and sends that signal to the WIR-TRAN via the 10 foot cable. Establish a location for the Repeater that is in line of sight from where the wireless remote will be used most frequently and that is no more then 75 feet from furthest where the remote will be used. NOTE: If extension is needed, use S.R. Smith part number WE-65 and follow installation instructions supplied with the Repeater Extension. To mount the Repeater, carefully insert a small flathead screwdriver into groove between the Dome and Base approximately where the locking dimples are located. Pry the Dome out of the locking dimples. Then carefully insert the small flathead screwdriver into the groove between the Dome and the Base in an adjacent locking dimple and pry the Dome out. Then separate the Dome from the Base by hand. Using the supplied self-drilling screws, locate a suitable mounting surface and screw the base to this surface. (The Repeater must be mounted in plain sight not more than 75 feet from the point where the remote will be used.) Note that the marking TOP must be in the 12 o clock position and the wire slit must be in the 6 o clock position. Do not over tighten the screws as it may damage the Repeater base. Realign the Repeater Dome to the Base and ensure that the wire is exiting the base through the slit and the Locking Dimples are aligned with the locking holes. Apply enough pressure so that the Dome snaps into the base. Flathead Screwdriver Repeater 10 feet Dome/Base groove Locking Dimple Mounting Screws Orientation Marker Mounting Holes Repeater Dome Base Slit for Repeater Wire Repeater Base 79-15204-00 REV.A4 http://www.srsmith.com Page 6 of 8

OPERATING INSTRUCTIONS WIR-TRAN ROCKER SWITCH OPERATION The WIR-TRAN receiver box houses one rocker switch, for operation with the wireless transmitter, the switch needs to be in the DOWN or REMOTE position. To manually turn ON the 12VAC light connected to the Rocker Switch, flip the Rocker Switch UP or to the ON position. When the Rocker Switch is in the ON position, the Wireless Remote will not be able to turn OFF the 12VAC light connected to the Rocker Switch terminal. To turn OFF the 12VAC light manually, flip the Rocker Switch to the MIDDLE or OFF position. NOTE: In the OFF position, the wireless remote operation will be bypassed. To re-enable the wireless remote operation, flip the Rocker Switch back to the BOTTOM or REMOTE position. NOTE: If the unit turns ON when the switch is returned to the REMOTE position, simply use the wireless remote to turn OFF the unit if desired. NOTE: Switch is shown in the ON position. WIRELESS REMOTE OPERATION NOTE: The Rocker Switch on the WIR-TRAN must be set to REMOTE for wireless operation. The POWER ON/OFF button controls the 12VAC light connected to the Rocker Switch terminal. With each push of the button, the WIR-TRAN toggles the light ON and OFF. Circuit 1 control 79-15204-00 REV.A4 http://www.srsmith.com Page 7 of 8

79-15204-00 REV.A4 http://www.srsmith.com Page 8 of 8