Opposed Piston Differential Pressure Switches

Similar documents
Temperature Switches. General Instructions

102 Differential Pressure Switch

103 Differential Pressure Switch

B Temperature Switches

Big Hermet Pressure Switches

Opposed Piston Differential Pressure Switches

Opposed Piston Differential Pressure Switches

Pressure Switch SOR. Sifter ready to run: Adequate pressure to switch. Sifter not ready to run: Either loss of air pressure, or open guard.

101/121 Differential Pressure Switches

101/121 Differential Pressure Switches

102/103 Differential Pressure Switches

534HS Pressure Transmitter

RF Point Level Control with Sensor Monitor

3820 Pressure Switch-Transmitter

Ultrasonic Two-Wire Point Level Control with Tip-Type Sensor

Ultrasonic Two-Wire Point Level Control

Pivot Seal Pressure Switches

Pivot Seal Pressure Switches for Fluid Power Applications

Adjustable Dead Band Pressure Switches

1500 Series Level Switches

Adjustable Dead Band Pressure Switches

Pressure and Vacuum Switches for Process Applications

Pressure and Vacuum Switches for Process Applications

Nuclear Qualified Temperature Switches

Dual Hi-Lo Pressure Switches

1600 Series Liquid Level Controllers

Pressure and Vacuum Switches for Process Applications

1451 Control Valve. General Instructions. Table of Contents

T21 Thermal Differential Switch

Pressure and Vacuum Switches for Process Applications

Mini-Hermet Pressure Switches

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Mini-Hermet Pressure Switches

7SP. Stainless Steel Pump AMERICAN STAINLESS PUMPS STAINLESS STEEL PUMPS FOR THE COMMERCIAL MARKETPLACE

1450 Control Valve. General Instructions. Table of Contents

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

Dual Hi-Lo Pressure Switches

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

1000 Series Piston Type Differential Pressure Gauges

Dual Hi-Lo Pressure Switches

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

rugged, reliable problem solvers

Ex m Solenoid Operator Type 0519

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Zone 1 Linear Range - Installation Guide

Flameproof Level Sensor (Flameproof F/S FP)

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Compact differential pressure switch Models DC, DCC

SITRANS P measuring instruments for pressure

Mini-Hermet Pressure Switches

SECTION A-A

M-100 Adjustable flow switch with right-angle flow

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Compact pressure switch Model PCS

Dual Hi-Lo Pressure Switches

Type 2000 Transducer Product Instructions

SATRON VT Pressure Transmitter

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Product Specification 120XXE00 EQUALIZER AND 120XXC00 CONVERTER, 12V TO 24V FAMILY

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.

Compact temperature switch Model TCS

Mini pressure switch Stainless steel switch enclosure Model PXS

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

FUNCTIONAL SAFETY CERTIFICATE

IECEx Certificate of Conformity

SP/SF Series Flow Switches

Product Specification 12010E00 EQUALIZER AND 12010C00 CONVERTER, 12V TO 24V FAMILY

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves

Floodlight Range Installation Guide

WOLF ATEX TURBOLITE RANGE

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Series 10 Actuator. Installation, Operation and Maintenance Manual

IECEx Certificate of Conformity

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

Redundant Control System

Type Electronic Limit Switch

Valve Accessories. Limit switches, solenoid valves, lock-up valves, supply pressure regulators, volume boosters, quick exhaust valves, applications

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

EStrong-series Emergency Stop

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing

Installation Operation Maintenance ADDENDUM

Data Sheet. A-Series Miniature Watertight Pressure Switches

IECEx Certificate of Conformity

SMARTBOX MOUNTING BRACKET INSTALLATION INSTRUCTIONS John Deere 1790 (24/20 ), 1770NT, and DB CCS Planters Ladder & Rear Row Mount

Registered Quality System to ISO 9001

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Certificate of Compliance

Transcription:

Principles of Operation Opposed Piston Differential Pressure Switches General Instructions These instructions provide information for installation, electrical connection, process connection and calibration of SOR Opposed Piston Differential Pressure Switches. NOTE: If you suspect that a product is defective, contact the factory or the SOR Representative in your area for a return authorization number (RM). This product should only be installed by trained and competent personnel. = Hi Pressure Piston B = Lo Pressure Piston Fh = Force, Hi Pressure Fl = Force, Lo Pressure Fs = Force, Range Spring Fd = Force Resultant Differential (Hi Lo) Basic construction is opposing diaphragm sealed pistons connected by a common shaft. Hi side system pressure acts on Piston to produce force Fh. It is counteracted by adjustable range spring force Fs. Lo side system pressure acts on Piston B to produce force Fl. The resultant force corresponds to the difference in pressure between the Hi and Lo system pressures plus the force of the adjustable range spring, and moves the trip lever to actuate and deactuate the SPDT electrical switching element. Design and specifications are subject to change without notice. For latest revision, go to SORInc.com Table of Contents Principles of Operation... 1 Installation... 2 SIL Installation... 2 Process Connection... 3 Electrical Connection... 3 Calibration... 3 Dimensions... 4 TEX Marking Information... 10 Declaration of Conformity... 11 Form 279 (04.16) SOR Inc. Registered Quality System to ISO 9001 1/12

There are only three wetted parts on the Hi and Lo process connections: pressure port, diaphragm and o-ring. metal diaphragm may be welded to the pressure port for certain applications, thereby eliminating the o-ring. This force-balance system virtually eliminates friction and resultant wear while yielding excellent repeatability. These differential pressure switches are well suited for a variety of process applications. They are not intended for high pressure, fluid power (hydraulic) applications where high shock pressures and high cycle rates are expected. Installation This type of differential pressure switch can be installed in any position. If a breather drain is installed, the device should be mounted with the breather drain pointing downward (6 o clock) so condensation will drain from the housing. WETHERTIGHT HOUSING ttach the device to a suitable surface or pipe stanchion bracket with two 1/4-inch diameter bolts. Line mounting by either process or electrical connection is not recommended. EXPLOSION PROOF HOUSING ttach the device to a suitable surface or pipe stanchion bracket with two 1/4-inch diameter bolts. The T housing must be attached with 2-inch U-bolts over the housing hubs or two 1/4 in. diameter bolts. Line mounting by either process or electrical connection is not recommended. NOTE: When mounting to an irregular or uneven surface, install rubber washers on the bolts between the housing and the mounting surface to prevent housing deformation. Failure to mount the housing on a flat mounting surface may result in torsional forces on the housing that could cause false trips or render the pressure switch inoperative. Safety Integrity Level (SIL) Installation Requirements The SOR pressure switches have been evaluated as Type- safety related hardware. To meet the necessary installation requirements for the SIL system, the following information must be utilized: Proof Test Interval shall be one year. Units may only be installed for use in Low Demand Mode. Products have a HFT (Hardware Fault Tolerance) of 0, and were evaluated in a 1oo1 (one out of one) configuration. Form 1538 (03.12) 2012 SOR Inc. 2/12 Form 279 (04.16) SOR Inc.

Process Connection Pressure ports are marked Hi and Lo to indicate the high and low process pressure connections. Connect process piping accordingly. Use two wrenches-one to hold the hex pressure port to prevent it from moving, the other to tighten the process pipe or tube fitting. Care should be taken not to loosen the pressure port from the body or the body from the housing. Electrical Connection Ensure that wiring conforms to all applicable local and national electrical codes and install unit(s) according to relevant national and local safety codes. SOR Opposed Piston Differential Pressure Switches in RB and RH housings have terminal blocks as standard. ll other Opposed Piston Differential Pressure Switches have 18-inch 18 WG color-coded wire leads. Storing excess wire or making wire lead splices inside the switch housing will interfere with switch operation. Lo Hi Calibration SPDT Differential Pressure Blue (C) Black (NO) Red (NC) Green (GND) No.1 2-SPDT Blue (C) Black (NO) Red (NC) Yellow (C2) Brown (NO2) Orange (NC2) No.2 Green (GND) Differential Pressure Form 279 (04.16) SOR Inc. 3/12 Lo Hi Units in Hazardous Locations Prior to calibration, make sure that the work area is declassified before removing the explosion proof cover to calibrate the unit. Failure to do so could result in severe personal injury or substantial property damage. Remove housing cover. First, calibrate the device as a gauge pressure switch, i.e. Lo side vented to atmosphere. Turn the set point adjusting nut located on the Hi side piston clockwise to increase the set point, or counterclockwise to decrease the set point. Calibrate to simulated system operating pressure conditions for optimum performance, i.e.: connect Hi and Lo sides to suitable pressure sources and raise pressures simultaneously to expected system operating pressure at desired set point. Vary Lo side pressure and fine tune the set point adjustment for actuation (deactuation) of the electrical switching element on increasing or decreasing differential pressure at simulated system operating pressure. Replace the cover.

Dimensions Weathertight-NEM 4, 4X, IP65 Drawing 0090262 107.3 4.22 69.9 2.75 52.0 2.05 33.3 1.31 (LOW) Housing Designator: RB, RH, RE Piston Number: 18 94.5 3.72 28.6 1.13 50.8 2.00 *230.6 9.08 ELECTRICL SEE CHRT 26.2 1.03 *57.4 2.26 37.3 1.47 71.4 2.81 133.4 525 6.4 CLERNCE SLOTS FOR 0.25 HRDWRE WITH 63.5 76.2 MIN TO 2.50 3.00 MX MOUNTING HOLES Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. Drawing 0090152 1/4 OR 1/2 NPTM (OPTIONL: HI, LO OR BOTH) 40.5 1.59 (HIGH) Conventional Explosion Proof 7.1 0.28 44.1 1.74 71.4 2.81 SIZE 1/4 NPTM SHOWN 1/2 NPTM 95.3 3.75 PIPE KIT OPTIONL Housing Designator: S Piston Number: 18 L 4/12 Form 279 (04.16) SOR Inc.

Weathertight-NEM 4, 4X, IP65 Drawing 0090265 107.3 4.22 52.0 2.05 69.9 2.75 33.3 1.31 LO Housing Designator: RB, RH, RE Piston Number: 15, 17 65.6 2.58 28.6 1.12 26.2 1.03 *230.6 9.08 ELECTRICL SEE CHRT DETIL 1 NPTM SCLE 0.38 2X 7.1 X 13.5 0.28 0.53 MOUNTING SLOTS 40.5 1.59 *57.4 2.26 1/4 OR 1/2 NPTM OPTIONL: HI, LO, OR BOTH HI 7.1 0.28 CONN SIZE 1/4 NPTF 1/2 NPTF * LENG PER PO SHOW 4 1 NPTM DD 1 LENGTH 1/4 NPTM SHOWN 1/2 NPTM 29. 1.1 38.9 15 Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. Drawing 0090151 142.3 5.60 Conventional Explosion Proof Housing Designator: S Piston Number: 15, 17 71.1 2.80 79.4 3.12 LO 20.6 0.81 6.7 0.26 ELECTRICL 3/4 NPTF STD 1/2 NPTF OPT OR PLUGGED OPT 2 PLCES 322.3 12.69 *230.6 9.08 *115.3 4.54 *74.9 2.95 40.4 1.59 TYP 4X 7.9 0.31 MOUNTING HOLES 1/4 OR 1/2 NPTM OPTIONL: HI, LO OR BOTH 80.8 3.18 TYP HI 161.1 6.34 120.7 4.75 14685 W 105TH ST LENEX, KS 66215 US 913-888-2630 ISO-9001 SORINC.COM Form 279 (04.16) SOR Inc. 5/12 6.4 0.25 CONN SIZE 1/4 NPTM 1/2 NPTM 1 NPTM 1/4 NPTM SHOWN 1/2 NPTM LENGTH * LENGTH SHOWN 46.0 DD 1.81 29.7 1.17 38.9 153 PRODUCT CERTIFICTION DRWING LL DIMENSIONS RE ±1/16 IN UNLESS OTHERWISE SPECIFIED MM LINER = IN DRWN BY K MITCHELL CHECKED BY M SMITH ENGINEER PPROVL S BOL DTE 28 MR 2011 THIS DRWING IS THE EXCLUSIVE PROPERTY OF SOR. NO USE WHTSOEVER OF THE INFORMTION CONTINED HEREON, NOR REPRODUCTION IN WHOLE OR PRT MY BE MDE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. TITLE DIM DWG 15 & 17 S DP EO NUMBER: 5090 SCLE: 0.75 DO NOT SCLE PRINT DETIL 1 NPTM SCLE 0.38 DRWING NUMBER REV 0090151 6 DWG SIZ SHEET 1 OF 1 B

Weathertight-NEM 4, 4X, IP65 Drawing 0090263 Housing Designator: RB, RH, RE Piston Number: 13, 14, 16 107.3 4.22 52.0 2.05 LO 64.9 2.56 28.6 1.12 26.2 1.03 *225.3 8.87 ELECTRICL SEE CHRT 40.5 1.59 *54.7 2.15 CLERNCE SLOTS FOR 6.4 0.25 HRDWRE WITH 63.5 2.5 MIN TO 76.2 3.00 MX MOUNTING HOLES 7.1 0.28 CONN 1 33.3 1.31 69.9 2.75 1/4 OR 1/2 NPTM HI OPTIONL: HI, LO OR BOTH 1 CONN SIZ Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. Drawing 0090150 Conventional Explosion Proof Housing Designator: S Piston Number: 13, 14, 16 142.3 5.60 71.1 2.80 79.4 3.12 LO 20.6 0.81 PR CON 1/4 1/2 3/4 *225.3 8.87 80.8 3.18 40.4 TYP 1.59 TYP 2X ELECTRICL 3/4 NPTF STD 1/2 NPTF OPT OR PLUGGED OPT *112.6 4.43 *72.2 2.84 4X 7.9 0.31 MOUNTING HOLES 6.4 0.25 PROD LL UN NO HER MD 1/4 OR 1/2 NPTM OPTIONL: HI, LO OR BOTH HI TITLE DIMENS 13, 14 & EO NUM 6/12 Form 279 (04.16) SOR Inc.

Conventional Explosion Proof Drawing 0090109 108.0 4.25 (TYP) 147.1 5.79 73.7 2.90 54.0 2.13 (TYP) (LOW) Housing Designator: SC Piston Number: 18 119.6 4.71 34.0 1.34 13.2 0.52 *240.2 9.46 ELECTRICL 3/4 NPT(F)(STD) 1/2 NPT(OPT) OR PLUGGED(OPT) (TYP 2) *121.7 4.79 8.7 0.34 *67.7 2.67 7.1 MOUNTING 0.28 HOLE (TYP 4) 1/4 OR 1/2 NPT MLE (OPTIONL: HI, LO OR BOTH) (HIGH) LENGTH 29.7 1/4 NPT(M) = (SHOWN) 1.17 38.9 1/2 NPT(M) = 1.53 Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. Drawing 0090248 Conventional Explosion Proof Housing Designator: T Piston Number: 18 Form 279 (04.16) SOR Inc. 7/12

Conventional Explosion Proof Drawing 0090111 142.9 5.63 108.0 4.25 (TYP) 71.4 2.81 54.0 2.13 (TYP) (LOW) Housing Designator: SC Piston Number: 15, 17 106.4 4.19 34.0 1.34 *240.2 9.46 ELECTRICL 3/4 NPT(F)(STD) 1/2 NPT(F)(OPT) OR PLUGGED(OPT) (TYP 2) *121.7 4.79 8.7 0.34 *67.7 2.67 7.1 MOUNTING 0.28 HOLE (TYP 4) 1/4 OR 1/2 NPT MLE (OPTIONL: HI, LO OR BOTH) (HIGH) LENGTH 29.7 1/4 NPT(M) = (SHOWN) 1.17 38.9 1/2 NPT(M) = 1.53 Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. Drawing 0090157 Conventional Explosion Proof Housing Designator: T Piston Number: 15, 17 8/12 Form 279 (04.16) SOR Inc.

Conventional Explosion Proof Drawing 0090112 LENGTH 29.7 1/4 NPT(M) = (SHOWN) 1.17 38.9 1/2 NPT(M) = 1.53 108.0 4.25 (TYP) 142.9 5.63 71.4 2.81 54.0 2.13 (TYP) (LOW) Housing Designator: SC Piston Number: 13, 14, 16 106.4 4.19 34.0 1.34 *234.8 9.24 ELECTRICL 3/4 NPT(F)(STD) 1/2 NPT(F)(OPT) OR PLUGGED(OPT) (TYP 2) *119.0 4.68 *65.0 2.56 7.1 MOUNTING 0.28 HOLE (TYP 4) 8.7 0.34 Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. Drawing 0090156 1/4 OR 1/2 NPT MLE (OPTIONL: HI, LO OR BOTH) (HIGH) Conventional Explosion Proof Housing Designator: T Piston Number: 13, 14, 16 Form 279 (04.16) SOR Inc. 9/12

TEX Marking Information Sample Nameplate Drawing 0720044 Manufacturer s Registered Trademark TEX Listing Information Product Model Identification Serial Number (First Two Numbers Indicate Year of Manufacture) NOTE: The unit conforms to the requirements of clause 6.3.12, EN 60079-11: 2007. The unit is capable of withstanding a 500 Vrms isolation test between circuit and enclosure. 10/12 Form 279 (04.16) SOR Inc.

Declaration of Conformity For TEX Certifi ed Models EC Declaration of Conformity Product Manufacturer Date of Issue We declare that the above products conform to the following specifications and directives Carries the marking Reference document R Series Pressure Switches SOR Inc. 14685 West 105 th Street Lenexa, Kansas 66215-2003 United States of merica pril 20, 2016 TEX Directive (2014/34/EU) Equipment Intended for use in Potentially Explosive tmospheres EN 60079-0: 2012 EN 60079-11: 2012 II 2 G Ex ia IIC T6...T4 Gb T6 (-40 C Ta 75 C) T5 (-40 C Ta 90 C) T4 (-40 C Ta 125 C) EC-Type Examination Certificate Baseefa11TEX0125 Issued February 16, 2012 TEX Notified Body Baseefa Ltd. (Notified Body No. 1180) Rockhead Business Park, Staden Lane, Buxton, Derbyshire SK17 9RZ United Kingdom Baseefa Customer Reference No. 1021 Person responsible Michael J. Bequette (VP of Engineering) Michael J. Bequette Engineered to Order with Off-the-Shelf Speed 14685 West 105th Street, Lenexa, KS 66215-2003 Form 1539 (04.16) SOR Inc. Form 279 (04.16) SOR Inc. 11/12

SORInc.com 14685 West 105th Street, Lenexa, KS 66215 913-888-2630 800-676-6794 US Fax 913-888-0767 12/12 Registered Quality System to ISO 9001 Form 279 (04.16) SOR Inc.