NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK.

Similar documents
Flow Chart Programming Instructions for : VOLTMETER 2 1/16

Temperature Programming Quick Reference Guide

Programming Instructions for : Pressure 2 1/16 + DOWN MODE UP. Spek Pro Fuel Rail Pressure Gauge

SPEK PRO MONITOR AND CONTROL

FEATURES: SPEK PERFORMANCE GAUGE FEATURES:

FEATURES: SPEK PERFORMANCE GAUGE TACHOMETER FEATURES:

Flow Chart Programming Instructions for : Transmission Temperature 2 1/16 START HERE PROGRAM MAIN MENU

NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK.

Wiring Installation Instructions for : Pressure. Wiring Installation Instructions for : Temperature. 2 1/16 Spek Pro Professional Racing Gauge

NEXUS. Introduction SENSOR MODULE &

INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH

UNIVERSAL GAUGE WIRE HARNESS

PRO-COMP/PHANTOM TACH

FOR SERVICE SEND TO: AUTO METER PRODUCTS, INC. 413 W. Elm St., Sycamore, IL USA (815) us at

Oil Pressure Display Gauges Part numbers: Analog Oil/Fuel SAE Pressure Gauge psi Analog Oil SAE Pressure Gauge.

INSTALLATION INSTRUCTIONS THERMOCOUPLE EXPANSION MODULE

10 Ch Peak & Hold Injector Driver PN

Installation Instructions for AEM Tru Boost Boost Controller Gauge

INSTALLATION INSTRUCTIONS MECHANICAL GAUGES

Replace light bulb with the same number bulb as the one removed. White Wire: Connect to +12 Volt Lighting

Part Number Analog Style 15 PSI Fuel/Boost Pressure Gauge. NOTE: Faceplate Configuration Instructions Included on Separate Sheet

P/N X-SERIES GAUGE VOLTAGE 8 TO 18V

Part Number Analog EGT Gauge

1955 & 1956 CHEVROLET CAR INSTALLATION INSTRUCTIONS

Optional: Wiring a Relay for Gauge Controlled Output

Replace light bulb with the same number bulb as the one removed. White Wire: Connect to +12 Volt Lighting

Installation Instructions for AEM Serial Gauge

Multi-Input Water/Methanol Injection Harness

General Information. Installation Tips. Connections

Part Number cc/min Water/Methanol Injection Flow Gauge

E9X/E8X/E6X CHASIS VEHICLES (With N54 Motors)

Internal MAP Water/Methanol Injection Controller ,

3RD GEN CHALLENGER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PRO PLUS WIDE BAND AIR/FUEL RATIO

AUTO-BLiP. User Manual Porsche INTELLIGENT DOWNSHIFTS. Version 1.2

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

FULL SWEEP STEPPER MOTOR INSTRUMENT KIT INSTRUCTION MANUAL 1969,REDLINE, 2020 SERIES

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.7

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

VW/AUDI MK7 VEHICLES

BusPro Series Instruction Manual

Installation Instructions for: Channel Thermocouple Amplifier

Ford EV6 Injector Adapter Harness User Manual

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

GM Throttle Body Adapter Harness User Manual

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

CLEAN POWER TM CPS Series Operator s Manual

Components. Options Accessory Harness USB Charger. Quick Connector. Hook & Loop / Cable-ties. RFID Antenna. Module. Main Harness.

HI-FLOW FUEL RAIL. Installation Instructions for Scion tc & xb AEM Fuel Rail AN Hose adaptor

advanced FLOW engineering Instruction Manual P/N:

There are two types of installations depending on how the current nitrous oxide system is installed.

INSTALLATION GUIDE Six Gauge Universal Digital Dash Panel Part Number: DP10002

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

ODY-19-1 AIR PRESSURE GAUGE

HLY-1111 HEAD TEMPERATURE GAUGE

INSTALLATION GUIDE Table of Contents

Classic Instruments Cluster. Installation Manual

GM Stepper Idle Adapter User Manual

INSTALLATION INSTRUCTIONS 5" DUAL CHANNEL ULTIMATE TACH MODEL 6881, 6883, 6884, Dual Channel 1 CH 2

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

# Traction Control Window Switch

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6002 YEAR SERIES:

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6003 Year Series:

Classic Instruments. Ultimate Speedometer & Speed-Tachular. Installation Manual

INSTALLATION GUIDE Chevrolet Monte Carlo Dash Panel Part Number: DP9002 Year Series:

advanced FLOW engineering Instruction Manual P/N: Make: Ford Model: F-150 Raptor Year: Engine: V6-3.

ODY-01-1 or ODY-01-2 SPEEDOMETER

ULX210. Register your product. Send us your photos. Warranty COLOR CHANGING LED UNDERCAR LIGHTING SYSTEM. Installation Manual

DLKEK3HN INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Owner s Guide APS596Z

TRU-TIME ADJUSTABLE CAM GEAR Part Number: BK & BK

WARNING: DO NOT USE HAND-HELD 2-WAY TRANSCEIVERS INSIDE YOUR VEHICLE WHILE DRIVING.

Tach-Force Chevy Truck

Classic Instruments Chevy. Installation Manual

Chevy Truck

USER MANUAL AND INSTALLATION GUIDE ENGINE RPM AND NOS SHIFT COUNTER NOS DELAY TIME IN SECONDS NOS START PERCENT NOS FINAL PERCENT

Part Number AEM 4-CH WIDEBAND UEGO CONTROLLER

Classic Instruments Ford F100. Installation Manual

Installation Instructions for / Universal Water/Methanol Injection Kit

Classic Instruments Chevelle. Installation Manual

Remote Vehicle Control System CA-150. Owner's Manual. Vehicle Security System With Remote Keyless Entry

ca 1553 Owner s Guide

Water/Methanol Failsafe

INSTALLATION INSTRUCTIONS PART NUMBER:

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6004 Year Series:

Classic Instruments Ford. Installation Manual

NEW VINTAGE INSTRUMENT AND GAUGE KIT INSTALLATION INSTRUCTIONS

advanced FLOW engineering Instruction Manual P/N: TR-1020B Make: Honda Model: Civic Year: Engine: L4-1.8L

Digital Trim. Part # 1037 WARRANTY AND DISCLAIMER

MCL-30K-TCH. Remove nuts/screws and clamp to remove factory gauges 1 MAN#650336

Part# Accessory Power Distribution Module

advanced FLOW engineering Instruction Manual P/N: Make: Ford Model: Mustang Year: Engine: I4-2.3L (t) EcoBoost

ULX210 COLOR CHANGING LED UNDERCAR LIGHTING SYSTEM

Classic Instruments Camaro. Installation Manual. Revised: January 6, 2015 Page 1

advanced FLOW engineering Instruction Manual P/N: SCORCHER BLUE Bluetooth Power Module

Installation Instructions for: DT2-AF2 Dual Channel & DT2-AF1 Single Channel Wide Band O2 Sensor Controller for A/F (Lambda) Measurement

ODYR-25-1 & SLX-25-1 rev. A VACUUM/BOOST PRESSURE, TEMP, and EGT GAUGE

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

Transcription:

Flow Chart Programming Instructions for : VOLTMETER 2 1/16 Program Main Menu (Press one button at a time) START HERE Main Menu ONE NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK. NORMAL/DIAL BRIGHTNESS: ON POWER UP THE GAUGE READS THE VOLTAGE. Press the center button to advance to PEAK PLAYBACK. NORMAL LIGHTING NORMAL LIGHTING PEAK PEAK PLAYBACK: Reads the highest value displayed on the Gauge since the last time the PEAK value was displayed. PEAK value will be held in memory until erased by pressing the RIGHT or LEFT button while in the PEAK level Press the center button to advance to HIGH RED-LINE SETTING. PEAK PEAK PLAYBACK: Press the center button to advance to HIGH RED-LINE SETTING. OR OPTION:RESTORE FACTORY DEFAULT ONE HI HIGH RED-LINE SETTING: Press the down or up button to move dial pointer to the high threshold. Press the center button to save and advance to THRESHOLD SETTING. HI HIGH RED-LINE SETTING: Press the center button to advance to THRESHOLD SETTING. ONE THRESHOLD SETTING: Press the down or up button to move pointer to low threshold. Press the center button to save and advance to COLOR SCHEME. THRESHOLD SETTING: Press the center button to advance to COLOR SCHEME. ONE PEAK,,HI COLOR SCHEME: Press down and up buttons to select a color scheme. (OFF-VIOLET-BLUE-GREEN-YEL- ORANGE-RED-WHITE). Press the center button to save and return to NORMAL/DIAL BRIGHTNESS. PEAK,,HI COLOR SCHEME: Press the center button to advance to DIAL BRIGHTNESS. OR OPTION:DEMO MODE ONE PEAK,,HI DIAL BRIGHTNESS: Press the RIGHT or LEFT command buttons to Control the brightness of the faceplate illumination. Press the center button to save and advance to NORMAL OPERATION. PEAK,,HI DIAL BRIGHTNESS: Press the center button to advance to NORMAL OPERATION OPTION:ADJUST POINTER BRIGHTNESS FOR SERVICE SEND TO: SPEK-PRO SERVICE 413 West Elm Street Sycamore, Illinois 60178 USA www.spekpro.com sevice@autometer.com (866) 248-6357 1 2650-1689-00 7/24/13

Flow Chart Programming Instructions for : VOLTMETER 2 1/16 Submenu (enter from main menu) (Press two(2) buttons simultaneously for 5 seconds) OPTION:RESTORE FACTORY DEFAULT: While in PEAK PLAYBACK, press and hold the center and right buttons for five seconds. Dial pointer will step five times and return to zero. This will erase all user-programmed calibrations and settings, and return to NORMAL/DIAL BRIGHTNESS. PEAK HI BOTH OPTION A:DEMO MODE: WHILE IN COLOR SCHEME, press and hold the center and right buttons for five seconds. Dial will scroll through the seven color schemes. The HI, and PEAK will light, and the dial pointer will move. Press the center button to return to NORMAL/DIAL BRIGHTNESS. Down Button Mode Button Up Button BOTH OPTION A:POINTER BRIGHTNESS: Press CENTER and LEFT buttons for five (5) seconds to enter pointer brightness mode. The dial pointer will start to flash and point to the upper right. ONE OPTION:POINTER BRIGHTNESS: Press LEFT or RIGHT buttons to adjust pointer brightness. Press the CENTER burron to save and return to NORMAL/DIAL BRIGHTNESS. 2

Programming Instructions for : Voltmeter SPEK PRO MONITOR AND CONTROL Refer to the Flow Chart Programming Instructions while reviewing this guide. Gauge is field programmable by the operator while installed in the vehicle. This programming is accessed by pressing the control buttons located on the face or the meter dial, ONE. The Down and Up buttons move the pointer to a desired setting or controls the faceplate illumination. + DOWN MODE UP MAIN MENU NORMAL/DIAL BRIGHTNESS SUBMENU MODE BUTTON TO PROGRAM LEVEL. THEN BOTH CENTER AND LEFT OR CENTER AND RIGHT BUTTONS FOR FIVE SECONDS TO ENTER SUBMENU PEAK PLAYBACK OPTION:RESTORE FACTORY DEFAULT HIGH RED-LINE SETTING THRESHOLD SETTING COLOR SCHEME OPTION:DEMO MODE DIAL BRIGHTNESS OPTION: POINTER BRIGHTNESS MODE 3

Programming Instructions for : Voltmeter PROGRAMMING STARTS IN MAIN MENU PROGRAM BUTTON ONE (1) IN THE MAIN MENU MODE. 1 NORMAL/DIAL BRIGHTNESS: On power up, the meter usually starts operation in NORMAL/DIAL BRIGHTNESS. Gauge reads the sensor value as temperature, pressure, etc. The Down and Up buttons will control the brightness of the dial lighting. Press the center Mode button to save the setting and advance you to PEAK PLAYBACK 2 PEAK PLAYBACK: Reads the highest value displayed on the gauge since the last time the PEAK value was displayed. PEAK value will be held in memory until erased by pressing the RIGHT or LEFT button while in the PEAK level Press the center Mode button to advance to HIGH RED-LINE SETTING 3 HIGH RED-LINE SETTING: Sets the point at which HIGH warning threshold is reached for that specific gauge. The Down and Up buttons will move the dial pointer to select HIGH RED-LINE SETTING. During normal operation the gauge constantly monitors the sensor value and compares it to the HIGH threshold. If the threshold is exceeded, the red HI indicator and fan are turned on. Press the center Mode button to save the setting and advance to THRESHOLD SETTING 4 THRESHOLD SETTING: Set the Minimum Threshold: Sets the point at which warning threshold is reached for that specific gauge. The Down and Up buttons will move the dial pointer to select the THRESHOLD SETTING. During normal operation the gauge constantly monitors the sensor value and compares it to the threshold. If the sensor value drops below the threshold, the yellow indicator is turned on fan is turned off. Press the center Mode button save the setting and advance to 5 COLOR SCHEME 5 COLOR SCHEME: Set Faceplate Color Scheme: Operator can select the color of the gauge dial illumination. Each time you press the Down control button you scroll through dial color selection until the dial light goes off. Then press the Up button to reverse the scroll. Select your dial color illumination by pressing the center Mode button to save the setting and advance to DIAL BRIGHTNESS 6 DIAL BRIGHTNESS: Adjust the dial brightness for day or evening driving conditions. The RIGHT and LEFT command buttons will dim or brighten the faceplate illumination. Press the center Mode button to save the setting and advance to NORMAL OPERATION 4

Programming Instructions for : Voltmeter SUBMENU SUBMENU IS ACCESSED THROUGH THE MAIN MENU. FIRST GO TO THE APPROPRIATE LEVEL OF THE MAIN MENU AND THEN FOL THE INSTRUCTIONS IN THE PROGRAMMING F DIAGRAM TO ENTER THE SUBMENU. THE MODE AND UP OR MODE AND DOWN BUTTONS SIMULTANEOUSLY FOR 5 SECONDS TO ENTER THE SUBMENU AND ONE BUTTON WHILE IN THAT SUBMENU. OPTION:RESTORE FACTORY DEFAULT: While in PEAK PLAYBACK, Main Menu, press and hold both the CENTER and RIGHT buttons for 5 seconds. The dial pointer will step 5 times and return to zero (0). All user programmed settings will be erased and the gauge will return to NORMAL OPERATION. OPTION A:DEMO MODE: Displays the features of the meter. The pointer goes up and down the scale, the dial colors change and the HI, and PEAK warning indicators light. The DEMO MODE does not time out. If the gauge is turned off in the DEMO MODE, it will start up in the DEMO MODE. Press the Mode button to return the gauge to NORMAL operation. OPTION :POINTER BRIGHTNESS MODE: The Down and UP buttons adjust the dial pointer brightness to blend in with the original manufacturer s gauges and the owner s requirements. Press the Mode button to return the gauge to NORMAL/DIAL BRIGHTNESS. 5

Programming Instructions for : Voltmeter GAUGE CRITICAL CONDITION GAUGE TYPE TEMPERATURE ALERT FLASHES RED HIGH URE TACHOMETER HIGH PYROMETER HIGH NITROUS OXIDE URE BOOST URE HIGH AIR/FUEL VOLTMETER ALERT/OUTPUT GUIDE PROGRAMMING INFORMATION: TO RESET THE PROGRAM TO NORMAL OPERATION FROM ANY MODE THE UP AND DOWN BUTTONS SIMULTANEOUSLY. THIS SOFT RESET CANCELS THE INFORMATION YOU PROGRAMMED IN THAT MODE ONLY AND RETURN YOU TO NORMAL OPERATION. THE FACEPLATE WILL FLASH WHEN BUTTONS ARE DEED TO ACKNOWLEDGE COMMANDS. PROGRAMMING ERRORS WILL BE SIGNALLED BY FLASHING THE FACEPLATE LIGHTING PURPLE, BLUE, GREEN THEN ORANGE. IF PROGRAMMING IS INACTIVE FOR 120 SECONDS THE MODE WILL TIME OUT AND THE GAUGE WILL RETURN TO NORMAL OPERATION, EXCEPT FOR IN THE DEMONSTRATION MODE. THE DEMO MODE WILL NOT TIME OUT UNTIL THE CENTER MODE BUTTON IS ED. IF THE GAUGE IS TURNED OFF IN THE DEMO MODE, IT WILL START-UP IN THE DEMO MODE. TO RESTORE FACTORY DEFAULTS, THE MODE BUTTON ONCE TO ENTER THE PEAK PLAYBACK. THEN AND HOLD THE MODE AND UP BUTTONS FOR FIVE SECONDS. YOUR PROGRAMMING WILL BE ERASED BUT FACTORY PROGRAM WILL NOT BE AFFECTED. 6

Wiring Installation Instructions for : Voltmeter SPEK PRO VOLTMETER GAUGE PACKAGE CONTAINS: Voltmeter Gauge Wiring Harness Neoprene EDPM Grommet M o u n t i n g C u p ( F o r Da s h M o u n t O n l y ) INTELLIGENT ELECTRICAL GAUGES. FEATURES: SPEK PERFORMANCE GAUGE FEATURES: GAUGES ARE PROGRAMMED THROUGH COMMAND KEYS ON FACEPLATE. STEPPER MOTOR DRIVES THE GAUGE POINTER OVER A 280 DEGREE SWEEP. WIDE-ANGLE-DIAL HAS A 15% LARGER VIEWING AREA ON A 2 1/16 GAUGE. PROGRAMMABLE 7 COLOR DIAL AND RED POINTER ILLUMINATION. OPTIONAL OUTPUT CONTROL MODULE. INSTALLATION INSTRUCTIONS: 1 DISCONNECT NEGATIVE (-) BATTERY TERMINAL. 2 VARIOUS MOUNTING SOLUTIONS ARE PRESENTED BY PROPARTS, LLC ON THEIR WEBSITE AT www.spekpro.com DASH INSTALLATION: SELECT LOCATION IN THE DASH TO MOUNT GAUGE AND CUT A 2 1/16 HOLE. USE A FILE TO INCREASE THE HOLE SIZE IF REQUIRED. BE SURE THERE IS SUFFICIENT ROOM BEHIND THE HOLE FOR THE METER CASE AND THE CONNECTORS YOU WILL USE. 3 IF A SUITABLE HOLE IN THE FIRE WALL IS NOT AVAILABLE, CUT AN 11/16 HOLE. 4 GROMMET MUST BE CUT TO PERMIT INSTALLATION OF WIRING HARNESS. (SEE DIAGRAM 1) 5 INSTALL THE GROMMMET AND MOUNTING CUP ON THE WIRING HARNESS AS SHOWN IN DIA- GRAM 2. GROMMET IS FOR THE HOLE IN THE FIREWALL. 7

Wiring Installation Instructions for : Voltmeter 6 DO NOT CONNECT WIRING HARNESS TO THE GAUGE UNTIL THE OTHER CONNECTIONS HAVE BEEN MADE AND TESTED. 7 CONNECT THE RED (+12 VOLT SUPPLY) WIRE TO ON CIRCUIT THAT GETS POWER WHEN THE IGNITION IS TURNED ON. THIS CIRCUIT MUST BE FUSED BEFORE THE IGNITION SWITCH (5 AMP, FAST ACTING FUSE). 8 CONNECT THE BLACK WIRE TO A GOOD GROUNDING POINT ON THE CAR S CHASSIS. 9 CONNECT THE WHITE WIRE TO THE DIMMER VOLTAGE GOING TO THE DASH LIGHTS. THIS WILL CAUSE THE METER BRIGHTNESS TO TRACK THE BRIGHTNESS OF THE REST OF THE INDICATORS. 10 CONNECT THE APPROPRIATE SENSOR SIGNAL AND GROUND WIRES. 11 PLUG THE WIRING HARNESS INTO THE GAUGE AND MOUNT IN DASH OR POD. 12 FOR DASH MOUNTING, ATTACH MOUNTING CUP OVER THE BACK OF THE GAUGE AND HAND TIGHTEN. DO NOT OVER-TIGHTEN. MOUNT CUP BEFORE INSTALLING GROMMET. FAILURE TO DO SO WILL TWIST WIRES CAUSING A SHORT CIRCUIT. 13 POWER UP THE GAUGE AND INSPECT ALL CONNECTIONS. IF THE GAUGE IS OPERATING NOR- MAL, PROCEED TO PROGRAMMING INSTRUCTIONS. 8

Wiring Installation Instructions for : Voltmeter DIAGRAM 1 PIN 12 Ground/Black PIN 12 / d PIN r/ PIN 1 u u / Pur l PIN 2 ol In u /Blu J1 Harness 1 2 3 4 5 6 7 8 9 10 11 12 GAUGE 10-Pin Wiring Harness & Plug Grommet Firewall Grommet DIAGRAM 2 Black-Chassis Ground 5-Pin Wiring Harness 3-Pin Wiring Harness CUP A To Output Control Module BATTERY +12 VOLT DC White-12V Dash Lighting Headlight Switch Fuse Fused +12V Scramble Boost (Option) +12VDC CAUTION: Connect the Voltage Input/ Blue Wire to Voltage Source. To Red Ignition Switch A Optional:Output Control Module Part # 14820 +12VDC 85 87 87A Red-12V Ignition Switch CAUTION: 12 VOLT DC POWER MUST BE CONNECTED TO THE IGNITION POWER AFTER THE FUSE. 30 PATENTED WIDE ANGLE DIAL FOR SUPERIOR VISIBILITY U.S PATENT #7,278,749 032010 PART# 14820 OUTPUT CONTROL MODULE: ALL SPEK GAUGES HAVE A PROGRAMMABLE HIGH AND LIMIT SETTING DETERMINED BY THE USER. WHEN A SETTING IS TRIPPED, AN OUTPUT SIGNAL IS GENERATED. THIS CAN BE USED TO SWITCH ON A RUGGED 35 AMP RELAY TO ACTIVATE A OIL ENGINE KILL, ALARMS, CUT THROTTLE BODY SENSOR TO DEFUEL KILL BOOST VALVE. 86 Gauge PIN 8 Output/Purple +12VDC WARNING: OUTPUT CONTROL MODULE NOT TO EXCEED 1.5 AMPS AT 12 VOLTS DC. WARRANTY WILL BE VOID IF INCREASED OUTPUT VOLTAGE OR CURRENT IS APPLIED. 9

Wiring Installation Instructions for : Voltmeter THERE ARE THREE SECTIONS TO THIS MANUAL: WIRING INSTRUCTIONS, PROGRAMMING INSTRUCTIONS AND F CHART PROGRAMMING INSTRUCTIONS. PLEASE READ EACH SECTION CAREFULLY BEFORE ATTEMPTING TO INSTALL OR OPERATE THIS PRODUCT. WARNING: ALL INSTRUCTIONS IN THIS MANUAL MUST BE FOLED TO INSURE SAFE INSTALLATION AND OPERATION OF THIS PRODUCT. NEVER DISASSEMBLE MODIFY OR TAMPER WITH THIS PRODUCT. THIS COULD CAUSE DAMAGE AND MAKE THEM UNSAFE TO USE. TAMPERING WITH THE PRODUCT WILL VOID THE LIMITED WARRANTY. INSTALLATION MUST BE PERFORMED BY AN EXPERIENCED AUTOMOTIVE TECHNICIAN. INSTALLER MUST USE SAFETY GLASSES. DISCONNECT THE NEGATIVE BATTERY TERMINAL BEFORE BEGINNING INSTALLATION. PROPARTS LLC IS NOT RESPONSIBLE FOR DAMAGE TO ENGINE, VEHICLE OR UNIT CAUSED BY ELECTRICAL SHORTS. DURING INSTALLATION, DO NOT INTERFERE WITH ANY EXISTING CONNECTIONS OR WIRES. ALL ELECTRICAL CONNECTIONS USE SOLDER LESS CONNECTORS AND INSULATE ALL CONNECTIONS WITH ELECTRICAL TAPE. AVOID WIRING NEAR ENGINE, EXHAUST SYSTEM, TURBINE OR ANY AREA THAT MAY RESULT IN DAMAGE. DISCONTINUE USE OF THE PRODUCT IF SMOKE OR A STRANGE ODOR IN PRESENT. CAUTION PROPARTS LLC IS NOT RESPONSIBLE FOR INCORRECT INSTALLATION OR PROGRAMMING OF SPEK GAUGES OR CONTROLLERS. SPEK GAUGES AND CONTROLLERS ARE DESIGNED FOR 12V DC ELECTRICAL SYSTEMS WITH A NEGATIVE GROUND. DO NOT ADJUST THE GAUGES OR GAUGE PROGRAM WHILE DRIVING OBEY ALL RULES AND REGULATIONS OF HIGHWAY AND STREET DRIVING. INSTALL SENSOR AND WIRE AWAY FROM HIGH HEAT AND / OR VIBRATION AREAS. USE CARE WHEN CONNECTING OR DISCONNECTING THE WIRING HARNESS. PULL OUT EACH CONNECTOR WHILE ING THE LOCK OF THE CONNECTOR FIRMLY. IF THE BATTERY TERMINAL IS DISCONNECTED, THE AUDIO, CLOCK AND OTHER MEMORY DATA MAY BE LOST. THE NECESSARY DATA WILL HAVE TO BE RESET AFTER INSTALLATION. 10

Wiring Installation Instructions for : Voltmeter 12 MONTH LIMITED WARRANTY Spek-Pro/Auto Meter Products, Inc. warrants to the consumer that all Auto Meter High Performance products will be free from defects in material and workmanship for a period of twelve (12) months from date of the original purchase. Products that fail within this 12 month warranty period will be repaired or replaced at Auto Meter s option to the consumer, when it is determined by Spek-Pro/Auto Meter Products, Inc. that the product failed due to defects in material or workmanship. This warranty is limited to the repair or replacement of parts in the Spek-Pro/Auto Meter Instruments. In no event shall this warranty exceed the original purchase price of the Auto Meter instruments nor shall Spek-Pro/Auto Meter Products, Inc. be responsible for special, incidental or consequential damages or costs incurred due to the failure of this product. Warranty claims to Spek-Pro/Auto Meter must be transportation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is non-transferable. All implied warranties shall be limited in duration to the said 12 month warranty period. Breaking the instrument seal, improper use or installation, accident, water damage, abuse, unauthorized repairs or alterations voids this warranty. Spek-Pro/Auto Meter Products, Inc. disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by Auto Meter. FOR SERVICE SEND TO: SPEK-PRO SERVICE 413 West Elm Street Sycamore, Illinois 60178 USA www.spekpro.com sevice@autometer.com (866) 248-6357 11 2650-1689-00 7/24/13