TRS2 non-contact tool breakage detection system

Similar documents
NON-CONTACT TOOL BREAKAGE DETECTION SYSTEM

Installation and user s guide H A. TP20 probe for FARO arm

RESM rotary scale. System features

Brake caliper machining: improve process control and reduce inspection costs

12CS/50CS Series. Coreless Spin-on Filters

RESM20/REST20 angle encoder

User s guide M B

ACTUATOR LA31 PRODUCT DATA SHEET

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

12CS/50CS Series Coreless Medium Pressure Filters

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Actuator piston position Sensor Type SHE

LASER ENHANCED SEMI-AUTOMATIC GRIP OWNER S MANUAL RED LASER GREEN LASER

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Electric Mini Slides MSC-EL

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

PSU EN54-4 Power Supplies

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Emergency lighting units EM powerled

Solenoid valves MH2/MH3/MH4, fast-switching valves

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

3 Installation of Display Unit > 3.5 Installation of Option Equipment

485 - NC NO/DA DN

PNEUMATICALLY ACTUATED 2-WAY

Emergency lighting units EM series

Electronic Pressure Switch EDS 3000

HIGH POWER SOLENOID DRIVER 1

Installation & User Instructions

Digital Pressure Regulator Sentronic PLUS Series 614

Installation Instructions

Specifications/price list CMA CNC controlled gantry drilling machines type RAPID-DRILL GRD CNC and GRD 50Z CNC

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Free Fall Fire Valve Range & Accessories

SG-B1 SERIES / SG-A1 SERIES

Function ECU, Wireless

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers

Magnetic Torpedo Laser Level with Base Model No Instruction Manual

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

LASERMET MINIATURE LED SIGN POWER AND SWITCH UNIT. Installation Instructions

Emergency lighting units EM powerled

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

DM-TR. series 10 RADIAL DRIVEN TOOL SYSTEM WITH DIRECT MOTOR TURRETS (PATENTED) TECHNICAL INFORMATION I.T ISSUED 09-11

CMA - 3RD. 3RD series CMA - GRD. GRD series. Tapping machines. Tapping machines. Flexible Drilling and Tapping Solutions CNC-drilling centers

Auto Feed Drills & Tappers. Comprehensive range Single spindle operations Multi-spindle processes. More Than Productivity

2-1. Tool Setter Series for CNC Machining Centers. toolsensor.com. Summary. Features

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL and SMT package available

Emergency lighting units EM powerled

For installation instructions refer to the mounting and dimensions details and the terminal layout drawings on page 5 of this manual.

Contents. Part no.: MLC500T Safety light curtain transmitter

TX³ RCCBs 2P up to 100 A

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

INSTRUCTION AND USE MANUAL

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

LED Twister II. User manual UK Version 1.0

Proportional relief valves

Proportional reducing valves

Low voltage AC drives

CNC Tool Room Milling Center MODEL: VM-760

Emergency lighting units EM powerled

World Pressure Filters A New Standard in 7,000 psi Pressure Filters

1104D-44TG2 1104D-44TG kwm 1500/1800 rpm. ElectropaK. Series. Basic technical data. Performance

K25000 & KD25000 Series

Electrak power track underfloor power distribution systems

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

2-way proportional throttle valve for block installation

6.2. Conveyor Sensor Systems. 200 Series Zero Pressure Accumulation. 200 Series Zero Pressure Accumulation

ABB Component Drives ACS150, 0.5 to 5 Hp

The Quality of Light TM. MODEL: SSI-600-PDC Controller Operation Manual. Metaphase Technologies Inc. JAN-09

CPLab / CP Factory. Application module magazine. Data sheets

Auto Feed Drills & Tappers. Comprehensive range Single spindle operations Multi-spindle processes. More Than Productivity

MANUFACTURED IN THE UK

Digital Engine Tachometer

Dragon1 PowerStar Colours

EMS Installation Instructions

Solenoid valves MH2/MH3/MH4, fast-switching valves

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Digital Flow Switch (Sensor Part) Operation Manual

STT280 SEALED TILT SENSOR

Emergency lighting units EM powerled

Emergency lighting units EM powerled

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

Installation Instructions

PT Series Tank Top Filters

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Function ECU, Wireless

IQTF Range. Keeping the World Flowing. Electric full output turn actuators for choke and control valve applications

PNK-AC CNC CNC - HSS CIRCULAR SAWS GRINDING MACHINE

CDM CREEPDRIVE MOTOR

CENTRIFEEDER ELECTRONICS

PF 3100 ION PILOT CARD PRO.FIRE

ABB component drives ACS150, 0.5 to 5 Hp

Compact Rope-Activated Emergency Stop Switch. DIN mounting pattern for a globally recognized mounting configuration

World Pressure Filters A new standard in 7,000 psi pressure filters

EC200 ELECTRONIC CONTROL SYSTEM

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

Transcription:

Data sheet H-5450-8200-01-A TRS2 non-contact tool breakage detection system New improved tool recognition with ToolWise technology ensures reliable, high-speed, broken tool detection. System components TRS2 broken tool detection device The TRS2 is a cost-effective solution for high-speed broken detection of tools that are solid on-centre, e.g. drills, taps, etc. Air filter / regulator Provides the TRS2 with clean, dry air to protect it against coolant and swarf. Software for broken tool detection Renishaw has written software specifically for the TRS2. Software for a variety of different controllers is supplied with the system kit. It includes a high-speed spin cycle to remove coolant off the tool prior to checking. This cycle is recommended for optimum performance. Air blast For greatest consistency, particularly at 1000 r/min and 200 r/min, the optional air blast kit is recommended for blowing coolant from the tool. A solenoid valve is also available to turn the air supply on and off. PSU3 power supply Used when a 12 V to 24 V supply is not available from the CNC machine. System features Conventional non-contact tool breakage detection systems depend on the laser either being blocked (tool OK) or not blocked (tool broken). The TRS2 is different; featuring a new improved tool recognition system with ToolWise technology. The unique tool recognition electronics determine whether a tool is present by analysing the reflective light pattern from the rotating tool. Random light patterns created by coolant and swarf are ignored, reducing the chances of not detecting a broken tool due to coolant blocking the beam. ToolWise electronics recognise a tool that is rotating at 5000 r/min, 1000 r/min, or 200 r/min, making the TRS2 very flexible to use. Fast operation. Typically, a tool spends approximately 1 second in the laser beam. Inexpensive and easy to install, as all components are housed in a single unit. No M codes are required. Tools as small as Ø0.2 mm (0.008 in) can be checked. The TRS2 can detect tools between 0.3 m and 2.0 m away, making it suitable for a wide range of machines, although it is optimised for use at 1 m and less. Compact dimensions 38 mm W 73 mm D 83 mm H (1.50 in W 2.87 in D 3.27 in H). Patent applied for. depending on the range, tool surface finish, machine environment and installation.

Data sheet TRS2 non-contact broken tool detection system Dimensions and laser warning symbols : TRS2 and TRS2-S Dimensions in mm (in) 73 (2.87) NOTE: These figures show a TRS2 unit. On the TRS2-S unit, the Receiver focus and Laser focus screws are not available. 68 (2.68) Ø4.7 (0.19) 38 (1.50) Rx lens Labels 78 (3.07) 83 (3.27) Signal strength bar graph } Aperture label 16 (0.63) 32 (1.26) Tx aperture 4.5 (0.18) 4.5 (0.18) Status LED 14.5 (0.57) Laser 4 holes M6 8 mm deep 6.5 (0.26) 6.5 (0.26) 31 (1.22) 19 (0.75) 31 (1.22) 7 (0.28) 18.5 (0.73) Ø6.5 Receiver focus screw (not available on TRS2-S) 5 (0.20) 25 (0.98) M6 through bolt 19 (0.75) 36.5 (1.44) 3.5 (0.14) 2 identical slots for M6 screws Laser focus screw (not available on TRS2-S) 2 (0.08) 28.75 (1.13) 23.5 (0.93) 6.5 (0.26) Laser focus screw (not available on TRS2-S) Receiver focus screw (not available on TRS2-S) Warning label Explanatory label Aperture label LASER RADIATION DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT 1 mw MAXIMUM OUTPUT EMITTED WAVELENGTH 650 nm COMPLIES WITH 21 CFR 1040.10 AND BS EN 60825-1

Dimensions : TRS2 and TRS2-S with cable connector Dimensions in mm (in) 66 (2.60) 83 (3.27) Cable fitted 39.4 (1.55) 25.4 (1.00) 51 (2.00) 73 (2.87) 28 (1.10) 107 (4.21) 153 TRS2 without mounting bracket 41 (1.61) 14 (0.55) TRS2 with mounting bracket 18 (0.71) 122 Receiver lens kit Under severe conditions the receiver lens may become damaged or contaminated and therefore require replacement. A lens kit is available for this purpose. Sapphire glass window kit If the TRS2 receiver lens is likely to become scratched due to bombardment by swarf, it can be protected by a hard sapphire glass window. Air cap kit If the air cap becomes damaged, it may be replaced with a new air cap.

Data sheet TRS2 non-contact broken tool detection system Mounting details Rear mounting Mounting bracket M6 mounting screw (supplied) M6 screws (not supplied) M6 locking screw and washer (supplied) M6 nut (supplied) Machine structure (part of) M6 locking screw and washer (supplied) M6 nut (supplied) Side mounting Bottom mounting M4 mounting screws (not supplied) Bracket (not supplied) M6 mounting screws (not supplied)

Electrical connections the signal monitor output is available only with the version of TRS2 that is fitted with a connector. This output is recommended for use when the bar graph cannot be seen. pink blue DVM TRS2 Signal monitor { CNC controller Power input { brown white +11 Vdc to 30 Vdc 0 Vdc Power to TRS2 Common grey I/O supply skip input Status output SSR N/C N/O green yellow Probe input. Connect either the yellow or the green, but do NOT connect both wires. Ensure the connection is correct BEFORE cutting the spare wire. black Screen Controller protective earth, (also referred to as PE, starpoint or earthplate). SSR contact Controller reference ground Status Normally-closed (N/C) Normally-open (N/O) Tool detected Open Closed Tool not detected Closed Open Spindle speed selection For a tool to be detected by the TRS2 system, it must be rotating at a fixed speed of 5000 r/min, 1000 r/min or 200 r/min. The required spindle speed must be selected in the macro software. 5000 r/min. This is the default speed and gives the shortest detection time. It is recommended that this speed is used whenever possible. However, when selecting this speed you must ensure that it does not exceed the maximum speed indicated by the manufacturer. 1000 r/min. Select this speed when 5000 r/min is not suitable. Before detecting a tool at this speed, the tool must be cleaned, either by using a compressed air blast or by spinning the tool at a greater speed. Optionally, you can use an air blast kit that is available from Renishaw plc (see the Parts list). 200 r/min. This speed is reserved for use with deep hole drills. The detection time is likely to be significantly longer that at the two other speeds. Before detecting a tool at this speed, it is recommended that the tool is cleaned using a compressed air blast.

Data sheet TRS2 non-contact broken tool detection system Air blast kit The air blast kit is an optional device that can be used just prior to the broken tool detection cycle to clean coolant and swarf from the tool. When checking a tool that is rotating at either 1000 r/min or 200 r/min, it is recommended that the air blast unit is used for optimum performance. Solenoid kit A solenoid kit is available to control the flow of air to the air blast nozzle. Dimensions in mm (in) 55 (2.16) 27.5 (1.08) Side view Tool 15 (0.60) Air nozzle 80 (3.20) 20 (0.79) 56 (2.20) 1/8 in BSP Ø13 (Ø0.51) through hole for M12 mounting screw Top view 6.5 (0.26) 19 (0.75) 2.0 (0.08) 6.5 (0.26) 15.0 (0.60) 65 (2.56)

Specifications Application Laser type High speed non-contact tool breakage detection of solid tools. The laser emits visible red light at a wavelength of 650 nm and has a power output of less than 1 mw. It is driven by a continuous pulse train running at a frequency of 125 khz. The pulse duration is 2 µs and each pulse has a maximum energy of 7.2 10-9 J. The laser used is classified as a Class 2 product as defined by BS EN 60825-1:1994. It complies with 21CFR 1040.10 except for deviations pursuant to Laser Notice No. 50 dated July 26, 2001. Working temperature 5 C to 50 C Storage temperature 10 C to 70 C IP rating Life IPX8 with air on. Tested to >1 million on/off cycles. Tool diameter Each TRS2 unit is tested with a Ø0.5 mm, blue finish, HSS jobber drill (Farnell part no. 203778) at a range of 350 mm (13.8 in). Test conditions: Dry tool, spinning at 5000 r/min, which must be detected by the TRS2 within 1 second. Pneumatic supply Dimensions (without mounting bracket) Weight Mounting Detection range TRS2 units TRS2-S unit Input voltage Current consumption Fuse Cable Output Ø4 mm air pipe. Air supply to the TRS2 system must conform to ISO 8573-1: Air quality of class 1.7.2. 38 mm width 73 mm depth 83 mm height (1.50 in width 2.87 in depth 3.27 in height). 0.75 kg (1.65 lb) including 10 m of cable. Mounting bracket provided, with M6 clearance slots. An alternative mounting arrangement is provided by M4 tapped and clearance holes in the product housing. Adjustable between 300 mm (12 in) and 2 m (78 in). Factory set to 350 mm (13.8 in). Fixed at 350 mm (13.8 in). 11 Vdc to 30 Vdc. Power can be drawn from a CNC machine s 12 V to 24 V nominal dc supply. Alternatively, power can be obtained from a Renishaw PSU3 power supply unit. Typically less than 65 ma at 12 Vdc and less than 43 ma at 24 Vdc. 50 ma resettable fuse protects the solid state relay (SSR) output. 5-core plus screen cable. Each core 18/0.1 insulated. Ø5.0 (0.20 in) x 10 m (32 ft). Solid state relay (SSR), normally-open/normally-closed contact, max. 40 ma (fused at 50 ma). More information The TRS2 is available as a retrofit solution for existing machines, including probe software, installation and training. Contact your Renishaw supplier for further details. For further information on the products described in this data sheet, please visit www.renishaw.com then choose Machine tool.

Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR United Kingdom T +44 (0)1453 524524 F +44 (0)1453 524901 E uk@renishaw.com www.renishaw.com Parts list please quote the part number when ordering equipment Type Part number Description TRS2 (unit only) A-5450-0400 TRS2 unit with 10 m cable, mounting bracket, pin spanner, product documentation and software on CD, beam terminator, and laser warning sign (P-LA01-1066). TRS2 (full kit) A-5450-1000 Contains all the items in kit A-5450-0400, plus 4 m cable conduit, air assembly kit, 25 m air pipe, and 2 2 m air pipe conduit. TRS2 with cable connector (unit only) TRS2 with cable connector (full kit) A-5450-0420 A-5450-1500 TRS2 unit with cable connector, mounting bracket, pin spanner, product documentation and software on CD, beam terminator, laser warning sign (P-LA01-1066), TRS2 box insert, and box. Contains all the items in kit A-5450-0420, plus 12.5 m cable with mating connector, air assembly kit, 4 m cable conduit, 2 2 m air pipe conduit, and packaging. TRS2-S (unit only) A-5450-0410 TRS2-S unit with 10 m cable, mounting bracket, pin spanner, product documentation and software on CD, beam terminator, laser warning sign (P-LA01-1066), TRS2 box insert, and box. TRS2-S (full kit) A-5450-1100 Contains all the items in kit A-5450-0410, plus air assembly kit, 4 m cable conduit, 2 2 m air pipe conduit, and packaging. Air filter service kit P-FI01-S002 Service kit for air regulator parts for both filter bowls. Deluxe air filter P-FI01-0008 Air regulator with blocked filter indication and auto drain. Air cap A-5450-0440 Replacement air cap and O-ring. Air blast kit A-5450-0480 Nozzle, mounting bracket. Solenoid kit A-5450-0490 Solenoid (24 V), air fitting, 6 mm tee connector, 15 m Ø6 mm black nylon tube, bulkhead fitting, tube clips (5 off). Air pipe (Ø6 mm) P-PF26-0008 10 m Ø6 mm black nylon tube (used in conjunction with the solenoid kit). Receiver lens A-5450-0470 Replacement lens and O-ring. Sapphire glass window A-5450-0460 Hard sapphire glass protective window and locking ring. Publications : Individual publications can be downloaded from our web site. Go to www. renishaw.com then choose Machine tool. Product documentation and software CD A-5450-8501 Contains a Quick start guide, Installation guides, programming guides, TRS2 system software and software installation instructions. For worldwide contact details, please visit our main web site at www.renishaw.com/contact *H-5450-8200-01* 2008 Renishaw plc. All rights reserved. Renishaw reserves the right to change specifi cations without notice Issued 01.08 Part no. H-5450-8200-01-A