Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Similar documents
Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot-Operated Directional Control Valves Series D3 - D11

Directional Control Valve Series D1VW

Chapter 2: Directional Control Valves

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Directional Control Valve

Pilot-Operated Proportional DC Valve Series D*1FH

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Chapter 6: Check Valves

Chapter 7: Sandwich Valves

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE

Chapter 6: Check Valves

Directional Seat Valve Series D4S (Denison)

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard

Proportional Pressure Relief Valve Series RE*T

Chapter 3: Proportional DC Valves

Chapter 3: Proportional DC Valves

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Chapter 10: Valves for Pipe Mounting

Proportional Pressure Reducing Valve Series D1FV

Proportional Pressure Relief Valves Series R4V and R6V (Onboard Electronics) General Description. Features.

Chapter 5: Flow Valves

Throttle Check Valve Series FM

Q max (see specifications table)

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Chapter 8: Slip-In Cartridge Valves

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

DIRECTIONAL CONTROL VALVES CETOP3

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

DIRECTIONAL CONTROL VALVES CETOP3

Pressure Control Valves. General Description. Specifications. Ordering Information

Chapter 5: Flow Valves

Directional Controls

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

ZRV. Direct Operated Check Valve Series ZRV (Denison)

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

General Specifications DRV DRV-Exm DRV-Exd

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Introduction. Pressure drops

2/2 Solenoid Cartridge Valve, Size 10

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Series PD directly operated solenoid valves

NG06. General Size NG6 NG10 Design

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

Servo solenoid valves with on-board electronics (OBE)

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

Directional Control Valves. General Description. Features. Specifications

Series PD directly operated solenoid valves

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min

3/2-way Solenoid Valve for pneumatics

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

Seated valves 500 bar

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004

Servo solenoid valves with on-board electronics (OBE)

Proportional Throttle Valves Series TDL

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

2/2 Pressure operated valves

VSD*S -MONITORED DIRECTIONAL CONTROL VALVES

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Type of operation Depending on requirement either one or two dry DC-solenoid,

Valve series KN-05 acc. to NAMUR, 3/2-way G1/4 780 Nl/min (0.792 Cv)

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Proportional pressure reducing valve, pilot operated

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

4/3-4/2 Directional valve with solenoid actuation

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

Transcription:

Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3 mm) D111VW NG3 All valves are piloted by a D1VW valve. Please see the separate ordering code for valves with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional valve. Additionally spools with a P to T connection in the deenergized position need an external pressure supply (external inlet) or an integral check valve. Valves with explosion proof solenoids EEx me ll see catalogue HY11-3343. Download: www.parker.com/euro_hcd - see Literature D31DW D31NW D41VW D81VW D111VW D81VW -61

Ordering Series type position Bore Size Feature D31DW Ø11 mm NG10 D31NW Ø11 mm NG10 High flow D41VW Ø0 mm NG16 D81VW Ø6 mm NG5 D91VW Ø3 mm NG5 High flow D111VW Ø50 mm NG3 3 position spools type a 0 b 001 D31D D31N D41 D81/91 D111 C E 3 position spools position 3 positions. position 0. position a or b. Standard Kolbentyp 009 positions. position 0. 00 003 004 F positions. position 0. 005 006 007 K positions. position 0. 009 1) 011 014 015 016 M R ) No center in offset position. No center in offset position. positions. position 0. positions, detent. position 0 or b. 01 0 031 S ) No center in offset position. No center in offset position. positions, detent. position 0 or a. No center in offset position. 03 054 081 08 position spools type a b 00 06 030 B D ) H position spools position Detent, operated in position a or b. No center or offset position. 1) Consider specific spool position. ) For D31NW and D111VW only pilot valve with detent available. 3) Not for D31DW, D91VW and D111VW available. 4) Not for spools 00, 007, 009, 014, 030, 031, 03, 054 available. 5) To be used in combination with rectifier plugs at 10 VAC / 30 VAC power supply. 6) Only D31, D41, D81, D91 available. -6

Ordering W Pilot oil supply and drain options Seals Solenoid voltage Connector as per EN 175301-803, without plug (Please order plug separately) Solenoid options Accessories Design series (not required for ordering) omit 3A 3B 3C 3D 6) 3E 6) 3F 6) 3R 1T Accessories Standard valve w/o accessories Pilot choke, meter-out Pilot choke, meter-in Pilot with pressure reducing valve Stroke adjustment side B Stroke adjustment side A Stroke adjustment side A and B meter-out + pressure reducing valve meter-in + pressure reducing valve omit T Solenoid option Standard solenoid without options without manual override Solenoid voltage K 1 V = J 4 V = U 5) 98 V = G 5) 05 V = Y 110 V 50 Hz / 10 V 60 Hz T 30 V 50 Hz / 40 V 60 Hz N V Seals NBR FPM Further spool types and solenoid voltages on request. Explosion proof solenoids EEx me ll see catalogue HY11-3343. Download: www.parker.com/euro_hcd - see Literature Inlet Outlet 1 Internal External External External Integral 3 3) check valve External 4 4) Internal Internal 5 External Internal Integral 6 3) check valve Internal -63

Ordering Series D31DW, D*1VW Induct. Position Control Series type position Bore Size Feature D31DW Ø11 mm NG10 D31NW Ø11 mm NG10 High flow D41VW Ø0 mm NG16 D81VW Ø6 mm NG5 D91VW Ø3 mm NG5 High flow D111VW Ø50 mm NG3 3 position spools type a 0 b 001 D31D D31N D41 D81/91 D111 00 003 C 3 position spools position 3 positions. position 0. position a or b. Standard Kolbentyp 009 004 007 009 1) E positions. position 0. 011 014 015 F ) positions. position 0. 01 0 K positions. position 0. position spools type a b 00 M ) positions. position 0. 06 030 B H position spools position 1) Consider specific spool position. ) Not for D31NW. 3) Not for D31DW, D91VW and D111VW available. 4) Not for spools 00, 007, 009, 014, 030 available. 5) To be used in combination with rectifier plugs at 10 VAC / 30 VAC power supply. 6) For hydraulic presses according to the safety regulations EN 693, solenoid option T (without manual override) and accessories I4N, I5N or I6N (start position monitored) are required. 7) The plug M1 x 1 for the position control is included. The monitor switch has to be located on the side to which the spool moves from the spring offset position. For 4/3-way valves two switches are required. -64

Ordering Series D31DW, D*1VW Induct. Position Control W Pilot oil supply and drain options Seals Solenoid voltage Connector as per EN 175301-803, without plug (Please order plug separately) Solenoid options Accessories Design series (not required for ordering) position Position control I3N 7) I6N 7) IN 7) I5N 7) C C, B, E, F (all spools) C, K, M (spool 9) I1N 7) C, H, K, M (all spools) C, E, F (spool 9) I4N 7) End position monitored, side A and B Start position monitored, side A and B End position monitored, side B Start position monitored, side B End position monitored, side A Start position monitored, side A omit T 6) Solenoid option Standard solenoid without options without manual override Solenoid voltage K 1 V = J 4 V = U 5) 98 V = G 5) 05 V = N V Seals NBR FPM Inlet Outlet 1 Internal External External External 3 3) Integral check valve External 4 4) Internal Internal 5 External Internal 6 3) Integral check valve Internal Attention: The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by the manufacturer. -65

Technical Data General Design Directional spool valve Actuation Solenoid Series D31DW D31NW D41VW D81/91VW D111VW Size NG10 NG10 NG16 NG5 NG3 Weight (1/ solenoids) [kg] 6.0 / 6.6 7.6 / 8.1 9.7 / 10.3 17.9 / 18.6 67.4 / 68.0 Mounting interface DIN 4340 A10 DIN 4340 A10 DIN 4340 A16 DIN 4340 A5 DIN 4340 A3 ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401 NFPA D05 NFPA D05 NFPA D07 NFPA D08 NFPA D10 CETOP RP 11-H Mounting position unrestricted, preferably horizontal Ambient temperature [ C] [ C] -5...+60 (without inductive position control) 0...+60 (with inductive position control) MTTF D value [years] 75 Hydraulic Max. operating pressure [bar] [bar] Pilot drain internal: P, A B, X: 350; T, Y: 105 Pilot drain external: P, A B, T, X: 350; Y: 105 Fluid Hydraulic oil according to DIN 5154 Fluid temperature [ C] [ C] -0... +70 (NBR: -5...+70), (without inductive position control) 0...+70 (with inductive position control) Viscosity permitted [cst] / [mm²/s].8...400 Viscosity recommended [cst] / [mm²/s] 30...80 Filtration ISO 4406 (1999); 18/16/13 Flow max. [l/min] 150 170 300 700 000 Leakage at 350 bar (per flow path) [ml/min] up to 100* 7...4* up to 00* up to 800* up to 5000* *depending on spool Opening pressure integral check valve [bar] n.a. see p/q diagram see p/q diagram see p/q diagram n.a. Minimum pilot supply pressure [bar] 5 7 5 Static / Dynamic Step response at 95 % [ms] Energized / De-energized DC solenoids Pilot pressure 50 bar 60 / 40 50 / 60 95 / 65 150 / 170 470 / 390 100 bar 55 / 40 50 / 60 75 / 65 110 / 170 30 / 390 50 bar 55 / 40 50 / 50 60 / 65 90 / 170 10 / 390 350 bar 55 / 40 50 / 50 60 / 65 85 / 170 00 / 390 AC solenoids Pilot pressure 50 bar 40 / 30 30 / 50 75 / 55 130 / 155 450 / 375 100 bar 35 / 30 30 / 50 65 / 55 90 / 155 300 / 375 50 bar 35 / 30 30 / 50 40 / 55 70 / 155 190 / 375 350 bar 35 / 30 30 / 50 40 / 55 65 / 155 180 / 375 Electrical characteristics Duty ratio 100 % ED; CAUTION: coil temperature up to 150 C possible Protection class IP 65 in accordance with EN 6059 (with correctly mounted plug-in connector) K J U G Y T Supply voltage / ripple [V] 1 V = 4 V = 98 V = 05 V = 110 V at 50 Hz/ 30 V at 50 Hz/ 10 V at 60 Hz 40 V at 60 Hz Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5 Current consumption hold [A].7 1.9 0.33 0.13 0.58 / 0.49 0.31 / 0.6 Current consumption in rush [A].7 1.9 0.33 0.13.1 /.0 1.05 / 1.0 Power consumption hold [W] 3.7 31 31.9 8. 64 / 59 VA 68 / 6 VA Power consumption in rush [W] 3.7 31 31.9 8. 31 / 40 VA 31 / 40 VA Solenoid connection Connector as per EN 175301-803, solenoid identification as per ISO 9461. Wiring min. [mm²] 3 x 1.5 recommended Wiring length max. [m] 50 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. -66

Position Control Electrical characteristics of position control M1x1 Protection class IP 65 in accordance with EN 6059 (with correctly mounted plug-in connector) Ambient temperature [ C] 0...+50 Supply voltage Us / ripple [V] 18...4 / 10 % Current consumption without load [ma] 30 Max. output current per channel, ohmic [ma] 400 Min. output load per channel, ohmic [kohm] 100 Max. output drop at 0. A [V] 1.1 Max. output drop at 0.4 A [V] 1.6 EMC EN50081-1 / EN5008- Max. tolerance ambient field strength [A/m] <100 Min. distance to next AC solenoid [m] >0.1 Interface M1x1 acc. to IEC 61076--101 Wiring min. [mm²] 5 x 0.5 brad shield recommended Wiring length max. [m] 50 recommended M1 pin assignment 1 Us 18...4V Out B: normally open 3 0V 4 Out A. normally closed 5 Earth ground Definitions Start position monitored: The valve is de-energized. The inductive switch gives a signal at the moment when the spool leaves the spring offset position (below 15 % spool stroke). At the switching point the spool is located within the closed position. It is secured that only the flow paths of the offset position are granted. End position monitored: The inductive switch gives a signal before the end position is reached (above 85 % spool stroke). Delivery includes plug M1 x 1 (see accessories, plug M1x1; order no.: 5004109). -67

Catalogue HY11-3500/UK Flow Curve Diagrams The flow curve diagrams show the flow versus pressure drop curves for all spool types. The relevant curve number D31DW and D41VW Curve number P-A P-B P-T A-T B-T D3 D4 D3 D4 D3 D4 D3 D4 D3 D4 001 4 1 4 1 3 4 3 5 00 1 3 3 6 3 4 4 6 003 1 4 1 5 6 004 4 1 3 1 5 3 5 005 1 4 3 3 5 006 1 3 3 3 4 6 007 4 1 1 5 6 4 5 009 9 8 8 5 7 6 10 011 3 1 1 3 4 3 5 014 1 4 1 5 6 4 3 5 015 4 1 4 6 016 4 1 1 3 5 00 4 3 4 5 4 3 4 5 01 3 4 8 0 5 8 4 3 06 3 3 3 5 030 4 3 3 3 6 3 7 031 3 4 1 03 5 054 3 6 7 081 6 6 7 7 08 7 6 5 7 for each spool type, operating position and flow direction is given in the tables below. D31DW D41VW D31NW Curve number P-A P-B P-T A-T B-T 001 3 3 5 00 3 3 7 4 3 003 3 4 4 004 3 4 4 005 4 1 4 006 8 9 7 9 009 4 6 6 4 10 011 3 3 4 015 1 4 016 4 3 4 00 6 4 3 6 01 7 8 0 4 9 030 5 3 5 D31NW All characteristic curves measured with HLP46 at 50 C. -68

Flow Curves / Integral Check Valve D81/D91VW and D111VW Curve number P-A P-B P-T A-T B-T D8/9 D11 D8/9 D11 D8/9 D11 D8/9 D11 D8/9 D11 001 3 5 5 3 4 5 1 00 5 1 5 1 5 3 4 5 1 003 4 3 6 004 4 5 3 5 3 4 5 1 005 1 4 5 006 4 6 007 3 1 7 3 5 009 4 3 8 3 9 4 3 10 1 011 3 3 5 014 1 8 3 5 015 3 3 4 5 016 3 3 4 5 00 6 5 5 5 6 3 8 1 01 5 10 3 0 10 5 5 06 6 5 030 3 5 5 3 4 5 1 054 4 5 3 5 3 4 5 1 D81/D91VW D111VW Integral check valve in the P port Mounting an integral check valve in the P port is necessary to build up pilot pressure for valves with P to T connection and internal pilot oil supply. The pressure difference at the integral check valve (see performance curves) is to be added to all flow curves of the P-port of the main valve. Directional valves with an integral check valve are available for the series D31NW, D41VW and D81VW. Flow curve D31NW Flow curve D41VW Flow curve D81VW All characteristic curves measured with HLP46 at 50 C. -69

Pilot Oil Options D31DW D31NW D41VW D81/91VW P T C B A M6 DIN906 M6 DIN906 1/16 NPTF open, closed Pilot oil Inlet Outlet A B C internal external internal external external external internal internal Orifice Ø1.5 Orifice Ø1.5 Orifice Ø1.5 Orifice Ø1.5 A B a 0 b a 0 b P X Y A C B T D111VW All orifice sizes for standard valves. -70

Dimensions D31DW Surface finish BK385 4x M6x40 ISO 476-1.9 13. Nm ±15 % NBR: SK-D31DW-N-91 FPM: SK-D31DW-V-91 D31NW Surface finish BK385 4x M6x40 ISO 476-1.9 13. Nm ±15 % NBR: SK-D31NW-N-91 FPM: SK-D31NW-V-91 The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. * Please add for each sandwich plate +40 mm (pressure reducing valve, choke valve meter-in/-out). -71

Dimensions D41VW Surface finish BK30 4x M10x60 x M6x55 ISO 476-1.9 63 Nm ±15 % 13. Nm ±15 % NBR: SK-D41VW-N-91 FPM: SK-D41VW-V-91 D81VW, D91VW Surface finish BK360 6x M1x75 ISO 476-1.9 108 Nm ±15 % NBR: SK-D81VW-N-91 / SK-D91VW-N-91 FPM: SK-D81VW-V-91 / SK-D91VW-V-91 The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. * Please add for each sandwich plate +40 mm (pressure reducing valve, choke valve meter-in/-out). -7

Dimensions D111VW Surface finish BK386 6x M0x90 ISO 476-1.9 517 Nm ±15 % NBR: SK-D111VW-N-91 FPM: SK-D111VW-V-91 The space necessary to remove the plug as per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. * Please add for each sandwich plate +40 mm (pressure reducing valve, choke valve meter-in/-out). -73