Datasheet 30 mm Multi-Color General-Purpose or udible Indicators Rugged, affordable, and easy-to-install multi-segment indicators Compact 30 mm diameter Illuminated segments provide easy-to-see operator guidance and indication of equipment status Uniform indicator segments appear gray when off to eliminate false indication from ambient light Models with, 3,, and color segments plus audible V dc to 30 V dc operation No assembly required, mounting nut and gasket supplied Standard udible Models Housing Style Color Position * * 3 udible larm Housing Color Connection** TL30 B G Y R X X N X QD B = Basic G = Green Y = Yellow R = Red B = Blue W = White X = No Segment N = None = udible X = Black *Position and can not be X = No Segment **Models with quick disconnect require a mating cordset C =. m (3.9 ft) Integral PVC Cable QD = Integral -, or 8-pin M/Euro-style quick disconnect Wiring Diagrams Note: ll models are bimodal and can be wired as PNP or NPN devices. -Pin/Wire Models C/ C3 C C 3-30V dc or Key = Brown = White 3 = Blue = Black C = Color C = Color C3 = Color 3 C = Color = udible Pin (Gray wire) activates the corresponding color or the audible function, if available. and 3 segment models only require associated wires to be connected. Original Document 06089 Rev. July 08 06089
8-Pin / 7-Wire Models C C C3 C C 8 6 7-30V dc or Key = White = Brown 3 = Green (Not Used) = Yellow 6 = Pink 7 = Blue 8 = Red C = Color C = Color C3 = Color 3 C = Color C = Color = udible Green wire not used. Specifications Supply Voltage and Current V dc to 30 V dc Maximum current per LED segment: 0 m Omni-Directional Sealed udible larm: 0 m maximum current Supply Protection Circuitry Protected against transient voltages Input Leakage Current Immunity 00 µ udible larm Omni-Directional Sealed udible larm:.8 khz ± 00 Hz oscillation frequency, maximum intensity 90 db at m (3.3 ft) (typical) Operating Conditions 0 C to +0 C ( 0 F to + F) 90% maximum relative humidity (non-condensing) Storage Temperature: 0 C to +70 C ( 0 F to +8 F) Environmental Rating IEC IP6 UL Type X when mounted in suitable enclosure Construction Base, Segments and udible: UV stabilized polycarbonate Grommet: TPV Mounting Nut: PBT Sealing Gasket: PVC/NBR/CR Mounting M. threaded base, maximum torque. N m (0 in lbf) Mounting nut and sealing gasket included Connections Integral -pin, or 8-pin M/Euro-style quick disconnect, or. m (3.9 ft) integral PVC cable, depending on model Models with a quick disconnect require a mating cordset Vibration and Mechanical Shock Meets IEC 60068--6 requirements (Vibration: 0 Hz to Hz,.0 mm amplitude, minutes sweep, 30 minutes dwell) Meets IEC 60068--7 requirements (Shock: 30G ms duration, half sine wave) IK07 (EN 60068--7 with SMBMSR bracket) Certifications Indicators LEDS are independently selected; to colors depending on model Indicator Response Time Indicator On/Off: millisecond maximum Indicator Characteristics Color Dominant Wavelength (nm) or Color Temperature (CCT) Color Coordinates x y Lumen Output (Typical at C) Green nm 0.60 0.708 7. Red 60 nm 0.690 0.308. Yellow 9 nm 0.8 0.3 6. Blue 68 nm 0.36 0.06.0 White 00K 0.33 0.360 7. Required Overcurrent Protection WRNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class Power Supply. Supply wiring leads < WG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (WG) Required Overcurrent Protection (mps) 0.0 3.0.0 6.0 8 0.8 30 0. ny current above this value may activate the TL30. Refer to CIE 93 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates. www.bannerengineering.com - Tel: +-763--36 P/N 06089 Rev.
Dimensions # of colors Tower Height (H) Non-udible Omni-Directional Sealed udible 3 x 0.0 [0.79] H 99.7 mm (3.9 in).6 mm (.7 in) 3 6.7 mm (.0 in) 7.6 mm (6.8 in) 3.7 mm (6.0 in) 99.6 mm (7.9 in) 80.7 mm (7. in) 6.6 mm (8.9 in) M x. 8.0 [0.7] 3.0 [0.] ll measurements are listed in millimeters [inches], unless noted otherwise. ccessories Cordsets -Pin Threaded M/Euro-Style Cordsets Single Ended Model Length Style Dimensions Pinout (Female) MQDC-0. 0.0 m (. ft) Typ. MQDC-06 MQDC- MQDC-30.83 m (6 ft).7 m ( ft) 9. m (30 ft) Straight ø. MQDC-06R MQDC-R MQDC-30R.83 m (6 ft).7 m ( ft) 9. m (30 ft) Right-ngle ø. [0.7"] 3 Typ. [.6"] 30 Typ. [.8"] = Brown = White 3 = Blue = Black 3 8-Pin Threaded M/Euro-Style Cordsets with Open-Shield Model Length Style Dimensions Pinout (Female) MQDCS-806.83 m (6 ft) MQDCS-8 MQDCS-830.7 m ( ft) 9. m (30 ft) Typ. 7 6 8 3 MQDCS-80. m (0 ft) Straight ø. = White = Brown 3 = Green = Yellow 6 = Pink 7 = Blue 8 = Red P/N 06089 Rev. www.bannerengineering.com - Tel: +-763--36 3
8-Pin Threaded M/Euro-Style Cordsets with Open-Shield Model Length Style Dimensions Pinout (Female) MQDCS-806R.83 m (6 ft) MQDCS-8R MQDCS-830R.7 m ( ft) 9. m (30 ft) 3 Typ. [.6"] Right-ngle 30 Typ. [.8"] MQDCS-80R. m (0 ft) ø. [0.7"] Brackets SMB Right-angle bracket with curved slot for versatile orientation -ga. stainless steel Mounting hole for mm sensor 3 6 C B SMBFVK V-clamp, flat bracket and fasteners for mounting to pipe or extensions Clamp accommodates 8 mm diameter tubing or in. square extrusions mm hole for mounting sensor Hole size: = ø. 6 ø. 8 3 Hole center spacing: to B = 6.0 Hole size: = ø.6, B =.6 x 6.9, C =. SMBRVK V-clamp, right-angle bracket and fasteners for mounting to pipe or extensions Clamp accommodates 8 mm diameter tubing or in. square extrusions mm hole for mounting sensor 7 90 6 SMBMSP Flat SMBMS series bracket with mm hole for mounting sensors rticulation slots for 90+ rotation -ga. (.6 mm) cold-rolled steel 93 C B Hole size: = ø. Hole center spacing: = 6.0, to B = 3.0 Hole size: = 6.8 x 7.0, B = ø 6., C = ø. SMBMSR Right-angle SMBMS series bracket with mm hole for mounting sensors rticulation slots for 90+ rotation -ga. (.6 mm) cold-rolled steel 3 C B 8 Hole center spacing: = 6.0, to B = 3.0 Hole size: = 6.8 x 7.0, B = ø 6., C = ø. LMB Sealed Right-ngle Bracket Model Description Construction LMBER Pipe-Mount Models: Bracket kit with base, ½- pipe adapter, set screw, fasteners, O-rings, and gaskets. For use with stand-off pipe (listed and sold separately). Black polycarbonate www.bannerengineering.com - Tel: +-763--36 P/N 06089 Rev.
Elevated Mount System Model Features Components S-ME - Black Polycarbonate Streamlined black polycarbonate stand-off pipe adapter/cover Connects between mm light base and ½ in. NPSM/DN pipe Polished 30 Stainless Steel Black nodized luminum Clear nodized luminum SOP-E-0SS 0 mm (6 in) long SOP-E-300SS 300 mm ( in) long SOP-E-0 0 mm (6 in) long SOP-E-300 300 mm ( in) long SOP-E-0C 0 mm (6 in) long SOP-E-300C 300 mm ( in) long Elevated-use stand-off pipe (½ in. NPSM/DN) Polished 30 stainless steel, black anodized aluminum, or clear anodized aluminum surface ½ in. NPT thread at both ends Compatible with most industrial environments SOP-E-900SS 900 mm (36 in) long SOP-E-900 900 mm (36 in) long SOP-E-900C 900 mm (36 in) long S-EM30 - Black cetal Streamlined black acetal mounting base adapter/ cover Connects between ½ in. NPSM/DN pipe and 30 mm (-3/6 in) drilled hole Mounting hardware included Pipe Mounting Flange Pipe Mounting Flange Model Features Construction S-F Elevated-use stand-off pipes (½ in, NPSM/DN) M mounting hardware and nitrile gasket included Die-cast zinc base with black paint /- NPSM 0 x ø. ø8 ø70 S-F-3 Elevated-use stand-off pipes (½ in, NPSM/DN) M mounting hardware and nitrile blend gasket included Black Polycarbonate /- NPSM 9 8.77 x 0 ø0 ø60 Foldable Mounting Bracket Foldable Mounting Brackets Model Features Construction /- NPSM S-FFB For use with / inch stand-off pipes Stainless steel hardware Black polycarbonate 0 Ø70 x Ø P/N 06089 Rev. www.bannerengineering.com - Tel: +-763--36
Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WRRNTY IS EXCLUSIVE ND IN LIEU OF LL OTHER WRRNTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITTION, NY WRRNTY OF MERCHNTBILITY OR FITNESS FOR PRTICULR PURPOSE), ND WHETHER RISING UNDER COURSE OF PERFORMNCE, COURSE OF DELING OR TRDE USGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHLL BNNER ENGINEERING CORP. BE LIBLE TO BUYER OR NY OTHER PERSON OR ENTITY FOR NY EXTR COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR NY INCIDENTL, CONSEQUENTIL OR SPECIL DMGES RESULTING FROM NY PRODUCT DEFECT OR FROM THE USE OR INBILITY TO USE THE PRODUCT, WHETHER RISING IN CONTRCT OR WRRNTY, STTUTE, TORT, STRICT LIBILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. ny misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. ny modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. ll specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. Banner Engineering Corp. ll rights reserved