Pivoting Extension Boom

Similar documents
Exhaust hose reels. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. Car and truck dealerships

Fume Arms. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. No internal adjustment

Hose drop for fume and gases exhaust systems

Exhaust hose reels. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. Car and truck dealerships

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

Fume Arms. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. No internal adjustment

Horizontal downflow pleated cartridge dust collector

Fume Arms. AQC source capture equipment. Août 14, 2008 version. Leaflet under construction. More information to come at a later date.

Exhaust hose reels. AQC source capture equipment. Sept 11, 2008 version. Leaflet under construction. More information to come at a later date.

Exhaust hose reels. AQC source capture equipment. Superior technology generating substantial operating savings. Car and truck dealerships

Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration

AQC source capture equipment. Fume Arms. Superior technology generating substantial operating savings

Tube Axial Inline Fans

Horizontal downflow pleated catridge dust collector

Fume Arms. AQC source capture equipment. Superior technology generating substantial operating savings. No internal adjustment

Tubular Centrifugal Fans

MANCOOLERS. Macheta Airfoil Propeller Model UM / PUM / M39 / STL. Utility Mancooler Model UM. Pedestal Mount Mancooler Model PUM

Fume Extraction & Dust Collection

Leading the way for clean air in the new millennium. S o u r c e C a p t u r e

WSO Mist Collectors. cáäíê~íáçå=qéåüåçäçöó Ñçê=jáëí=`çääÉÅíáçå

Affordable portable filtration unit

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

LEDGELESS VERTICAL CARTRIDGE DUST COLLECTOR

LINCOLN ENVIRONMENTAL SYSTEMS

Inline Fans [ 14 ] * UL is optional and must be specified.

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

Portable HEPA System

& 12" 96" / TABD CATALOG

BenchTop Extraction Arm FX2

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Centrifugal Utility Fans - SFD/SFB

TUBULAR CENTRIFUGAL INLINE FANS

BenchTop Extraction Arm FX2

BenchTop Extraction Arm FX2

V05 General Purpose Bench Fume Hood

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

Mixed Flow Inline Fan, Model MFSI

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Mancoolers Models MCY, MCB, MCP

Air Boss M-Series Media & Adsorption Air Cleaner

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

BenchTop Extraction Arm FX2

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

CAST ALUMINUM PRESSURE BLOWERS

High Performance Axial Fans

ENGINEERED FOR EXCEPTIONAL PERFORMANCE.

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

Centrifugal Fans - M41

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Extraction arm FX100 Original

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

Vane Axial Fans Models VAB and VAD. Belt and Direct Drive

S2005 Cabinets DESIGNERS AND MANUFACTURERS OF 19 RACK SYSTEMS

SECTION HVAC AIR CLEANING DEVICES

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Good Enough Never Is. Plug Fan SERIES 12

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

Centrifugal Spun Aluminum Products

Fire Damper. Grilles Diffusers Dampers Louvers VAV Boxes Sound Attenuators. Spectrum Industries

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

Twin City Fan & Blower

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Owner s manual for installation, usage and maintenance

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

DUST COLLECTORS. Stronger. Better. CLEANER.

WE GUIDE AIR LOUVERS

Twin City Fan & Blower

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

VANEAXIAL & TUBEAXIAL FANS

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

Extraction Arms. Capturing fumes at the source

Fixed Pitch Vane Axial Fan

Dust Collectors and Fume Exhausters

Americraft is dedicated to assist you, our customer, in all aspects of your air moving requirements.

Indoor Air Quality Solutions for Machining Applications MistBuster source collection and MX-Series centralized filtration

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI

Industry best 5 year fan housing warranty, 1 year motor warranty

Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Product manual Extraction arm KUA

Product manual Extraction arm KUA

CA3000C & CA6000C Cartridge Air Cleaners

Dryflo Mist Collectors

Defining Innovation. backward curved FANs

SQUARE INLINE CENTRIFUGAL FANS

Horizontal downflow pleated cartridge dust collector

Transcription:

Diversified Air ystems, Inc. M Pivoting xtension Boom Document: 02/03/10 Ball bearing movement ingle or double pivot Increases reach of equipment by up to 20 [6,2m] May be equipped with MAXFLO fume arm, MAXL exhaust hose reel or MAXDOP hose drop system Top or bottom exhaust outlets Two diameters available uperior technology generating substantial operating savings

High-Productivity Innovative Products M MAXBOOM xtension pivot boom Maxboom pivoting extension booms are designed to increase the area of reach for source capture products such as the MAXFLO self supporting fume arms and vehicle exhaust equipment such as hose reels and hose drops. The extension booms aid in reaching points which are distant from a wall or other mounting areas. xtension booms can also be use to support items such as welding wire feeders or to undersling hoses or cables in conjunction with their primary function. The swivel section of the extension booms is made of rolled steel pipe. The top and bottom of the pipe is adapted to accept a fan or flanged duct connection. The extension beams are manufactured of heavy gauge steel tubing with a bearing swivel. The spiral ducting mounted along the beam has a diameter of 6 [150 mm] or 8 [200 mm]. tandard units are supplied with brackets for mounting fume arms or hose drops. Double pivot type extension booms are divided by a bearing hinge which allows the user to reach back under the extension boom. Industrial Air pecialists With our headquarters in Louisville, Kentucky, Diversified Air ystems, Inc. has been provi ding quality air solutions to industrial and commercial facilities since 1981. During our more than twenty-nine years of operation, Diversified Air ystems, Inc. has established two important company traditions: offering state-of-the-art equipment at competitive prices and achieving long-term customer satisfaction. The staff of Diversified Air ystems, Inc. includes five application engineers, with a combined experience of more than 75 years in the air filtration and HVAC industry. Whether your faci lity requires an air filtration system for dust, mist, or fumes, or an HVAC solution to meet ventilation needs, Diversified Air ystems, Inc. has the equipment and expertise to meet the need. ervices include air quality analysis, system design, equipment sales, turnkey installation, onsite servicing, and supply of replacement filters and accessories. Other Filtration ystems available: Air Cleaners Containment Booths Decontamination Booths Downdraft Tables Dust Collectors Fans and Blowers Gas & Odor Control High Vacuum ystems Mist Collectors Paint Booths tainless teel Collectors Vehicle xhaust ystems Wet Dust Collectors 2

Pivoting Fume xtension Arms Boom M When extended reach is a must A great complement to MAXFLO fume arms, MAXL exhaust hose reels or MAXDOP hose drops Most of our competitors do not include these standard features : Completely self-supported Ball bearing movement for ease of usage Choice of two diameters : 6 [150 mm] or 8 [200 mm] and lengths up to 20 [6,2 m]. ingle or double pivot for multiple application mooth tube design equals lower static pressure obust and heavy gauge steel construction (powder painted) Multiple possibilities for various applications Large welding shops Truck maintenance Dust and smoke exhaust Typical applications for the Maxboom extension booms MAXBOOM double pivot boom with MAXFLO fume arm. MAXBOOM equipped with MAXDIV fan MAXBOOM single pivot boom with MAXL exhaust hose reel MAXBOOM double pivot with MAXDOP hose drop kit 3

Pivoting xtension Boom Outstanding MAXBOOM features Heavy-duty boom base Arm or hose drop bracket included Optional MAXDIV fan can be mounted on top of boom upport rod ensures leveling of boom Choice of top or bottom exhaust 6 [150 mm] or 8 [200 mm] exhaust sizes piral ducting for minimal static pressure 180 O pivot joint with friction disks Painted sturdy steel tubing 270 O ball bearing pivot middle joint (on double pivot model) with friction disks General description MAXBOOM extension swing booms are made of steel with a single or double ball bearing movement pivot joint(s). Friction disks at the joints ensure that no steel parts rub against each other causing premature wear. The spiral ducting in 6 [160 mm] or 8 [200 mm] mounted on saddles minimizes static pressure and air friction. Different lengths up to 20 [6,2 m] are available (page 7). The support rod attached between the boom base and rod bracket ensures leveling of MAXBOOM boom. Flexible hoses (250º F or 120º C) at joints are clamped to spiral ducting. Higher temperature tole rance flexible hoses are available. nd of boom is equipped with a support bracket for the MAXFLO fume arm or MAXDOP hose drop systems for vehicle fume exhaust. A custom support bracket can be installed at the end of the single pivot boom for MAXL exhaust hose reel for vehicle fume exhaust. 4 Note : Installation must be made according to local building codes and regulations

Pivoting xtension Boom Outstanding MAXBOOM features 1 7 2 4 5 10 8 4 9 MAXBOOM components single pivot model 7 3 11 6 11 1. Boom base and support bracket 2. Main exhaust pipe (top or bottom exhaust) 3. Bushing pivot joint 4. Flexible hose with clamps 5. piral exhaust duct 6. Primary support steel beam 7. Companion flange for exhaust (end cap included) 8. od bracket 9. Arm or hose drop bracket 10. upport rod 11. Duct saddles 1 7 2 4 5 10 8 4 7 3 11 6 11 13 11 12 11 C 5 4 9 MAXBOOM components double pivot model 1. Boom base and support bracket 2. Main exhaust pipe (top or bottom exhaust) 3. Bushing Pivot joint 4. Flexible hose with clamps 5. piral exhaust duct 6. Primary support steel beam 7. Companion flange for exhaust (end cap included) 8. od bracket 9. Arm or hose drop bracket 10. upport rod 11. Duct saddles 12. econdary support beam 13. Ball bearing pivot joint B A1 A2 Maximum reaches double pivot with MAXFLO fume arm A1. 15 [4.60 M] B. 5 [1.55 M] C. 11.2 [3.40 M] C Maximum reaches single pivot with MAXFLO fume arm A2. 20 [6.15 M] C. 11.2 [3.40 M] Note for booms longer than 10 [3 m]: First pivot booms longer than 10 [3 m] are shipped in two (2) even sections. x: B-1615 boom will have two (2) sections of 7,5 [2.3 m]. A joiner is included to attach the sections upon installation. 5

Pivoting xtension Boom MAXBOOM boom base dimensions Boom base 6 [150mm] Boom base 8 [200mm] Base dimensions Base size [inches] Dimensions [inches] / [mm] W h L1 L2 H1 H2 N D1 D2 D3 D4 CHAT 1 6 7 / 178 23.4 / 594 11.69/ 297 6.26 / 159 33.39 / 848 31.29 / 795 6 0.31/ 8 7.69 / 195 5.88 / 150 0.875 / 22 8 9 / 225 17 / 425 12.2 / 305 11 / 279 38.10 / 752 41.10 / 1027 8 0.34 / 9 9.69 / 246 7.88 / 200 0.875 /22 Boom base 6 [150mm] with 1hp MAXDIV fan Boom base 8 [200mm] with 2hp MAXDIV fan Available voltages Fan data 115/ 230-1-60 208/ 460-3-60 575-3-60 Blade type Backward inclined (aluminum) Housing steel (painted) Motor TFC.P.M. 3450 Note: efer to MAXDIV leaflet for fan capacity and technical data. A T C IT P U A T T I C P U Pa w.g. 2000 8.00 1750 7.00 1500 6.00 1250 5.00 1000 4.00 750 3.00 500 2.00 250 1.00 DF-101 CFM m 3 /hr Pa w.g. 2000 8.00 1750 7.00 1500 6.00 1250 5.00 1000 4.00 750 3.00 500 2.00 250 1.00 250 425 DF-102 500 850 750 1275 AIFLOW 1000 1700 tatic pressure & airflow 1250 2125 1500 2550 1750 2975 2000 3400 tatic pressure & airflow (hose diameter) 6 CFM m 3 /hr 200 350 350 600 500 850 650 1100 800 1350 950 1600 1100 1850 4'' [100mm] 5'' [125mm] 6'' [150mm] 8'' [200mm] 1250 2100

Pivoting xtension Boom Model numbers MAXBOOM model numbers CHAT 2 Model numbers each of work [feet] / [m] A B Total Ducting diameter [inches] / [mm] Mimimum mounting height [feets] / [m] Boom load capacity [lb] / [kg] Number of pivots Weight [lbs] / [kg] whitout fan B-1605 5 / 1.55 5 / 1.55 6 / 152 7.8 / 2.4 150 / 70 1 124 / 58 B-1610 10 / 3.10 10 / 3.10 6 / 152 7.8 / 2.4 150 / 70 1 144 / 67 B-1615 15 / 4.60 15 / 4.60 6 / 152 7.8 / 2.4 150 / 70 1 168 / 77 B-1620 20 / 6.15 20 / 6.15 6 / 152 7.8 / 2.4 150 / 70 1 200 / 91 BD-160302 3 / 0.92 2 / 0.60 5 / 1.55 6 / 152 7.8 / 2.4 75 / 34 2 170 / 77 BD-160703 7 / 2.15 3 / 0.92 10 / 3.10 6 / 152 7.8 / 2.4 75 / 34 2 177 / 82 BD-161005 10 / 3.10 5 / 1.55 15 / 4.60 6 / 152 7.8 / 2.4 75 / 34 2 185 / 84 BD-161505 15 / 4.60 5 / 1.55 20 / 6.15 6 / 152 7.8 / 2.4 75 / 34 2 200 / 91 B-1805 5 / 1.55 5 / 1.55 8 / 200 7.8 / 2.4 150 / 70 1 195 / 88 B-1810 10 / 3.10 10 / 3.10 8 / 200 7.8 / 2.4 150 / 70 1 214 / 97 B-1815 15 / 4.60 15 / 4.60 8 / 200 7.8 / 2.4 150 / 70 1 235 / 107 B-1820 20 / 6.15 20 / 6.15 8 / 200 7.8 / 2.4 150 / 70 1 254 / 115 BD-180302 3 / 0.92 2 / 0.60 5 / 1.55 8 / 200 7.8 / 2.4 75 / 34 2 230 / 104 BD-180703 7 / 2.15 3 / 0.92 10 / 3.10 8 / 200 7.8 / 2.4 75 / 34 2 255 / 116 BD-181005 10 / 3.10 5 / 1.55 15 / 4.60 8 / 200 7.8 / 2.4 75 / 34 2 272 / 124 BD-181505 15 / 4.60 5 / 1.55 20 / 6.15 8 / 200 7.8 / 2.4 75 / 34 2 298 / 135 BOOM BA INTALLATION NOT: Because of shipping and crating costs, sections of horizontal beams longer than10 (3 meters) are shipped in 2 parts. x : model B-1615 main beam will be 15 long but shipped in one piece of 10 and one piece of 5. Joining hardware is supplied for field assembly, if customer needs to have only 1 section of 15, surcharge for odd size shipment will be quoted. tatic pressure & air flow T A T I C P U (Pa) (w.g.) 500 450 400 350 300 250 200 150 100 050 0 2,00 1,80 1,60 1,40 1,20 1,00 0,80 0,60 0,40 0,20 0 MAXBOOM PIVOT BOOM TATIC PU *For lengths up to 20 FLOW 400 475 550 625 700 775 850 925 1000 1075 (cfm) 680 800 935 1060 1200 1315 1450 1575 1700 1825 (m 3 /h) 6 (160 mm) diameter 8 (200 mm) diameter uperior technology generating substantial operating savings Note : Double pivot booms static pressure will increase as the second pivot rotates left or right. Full rotation on second pivot will increase static pressure by 35-40%. tatic pressure shown in chart does not include source capture equipment. efer to appropriate leaflet for selection. 7

Pivoting xtension Boom Options MAXFLO fume arms MAXDOP exhaust hose drops MAXL exhaust hose reels tainless steel construction High or extreme temperature hoses at joints Non-standard lenghts and diameters Booms connected to dust collectors Longer than 20 [7 m] booms available (special design) Create your MAXBOOM extension swing boom specification 1. xtension swing boom should include: Pull rod on 1st pivot for levelling and support (standard) 2. xtension swing boom should include: Tubular steel tubing and spiral ducting for minimal static pressure (standard) 3. xtension swing boom should be of diameter of : A) 6 [160mm] B) 8 [200mm] 4. xtension swing boom should have a total length of: A) 5 [1,55m] B) 10 [3,10m] C) 15 [4,60m] D) 20 [6,15m] 5. xtension swing boom should consist of A) single pivot with friction disks and support base B) double pivot with 2/3 rd of length on first pivot and 1/3 rd of ball bearing action on second pivot 6. xtension swing boom should include: A) top ducting connection B) bottom ducting connection C) MAXDIV 1H.P. for 6 boom D) MAXDIV 2H.P. for 8 boom 7. xtension swing boom should include: A) support bracket for MAXFLO fume arm B) support bracket for MAXL exhaust hose reel (single pivot only) C) support bracket for MAXDOP hose drop system (for above systems, refer to appropriate leaflet) 8. xtension swing boom should include optional: A) 250 O F, [120 o C] Cotton neoprene flexible hoses at pivot joints B) 600 O F, [315 o C] ilicone fiberglass hose flexible hoses at pivot joints C) 850 O F, [650 o C] Teflon fiberglass hose flexible hose at pivot joints 9. 10 aluminium grab pole for positioning with MAXL or MAXDOP exhaust system Diversified Air ystems, Inc. 10801 lectron Drive, Louisville, Kentucky 40299 Toll free : (800) 264-8958 Tel. : (502) 267-0333 Fax : (502) 267-4241 Website : www.diversair.com email : info@diversair.com Copyrigth D.A., Inc. 8 Continuous product improvement is a policy of Diversified Air ystems, Inc. Product features and specifications may be modified without prior notice.