UltraSafe US22 Modular fuse-holders

Similar documents
Modulostar US10 Modular fuse-holders

Modulostar CMS10 Modular fuse-holders

IEC & 2. Fuse holders with indicator light. Poles N N M M C Z D213627

IEC fuse holders & fuse disconnectors: CMS 14

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

USCC & USM UltraSafe TM Fuseholders

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

American Round Fuses - Form 101 range

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIVERT 1000A Main Incomer, 690VAC

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

Fuse holders and fuses

INNOZED D0 fuse-bases with touch protection

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

Maximum R.M.S continuous current through IN - rated current fuses ( A ) Catalog Number MR10RESSORT.

INNOZED D0 fuse-bases with touch protection

BETA Switching Switches and Light Indicators

LINOCUR Size D02 63A 230VAC/440VAC

ULTRASAFE Fuse Holders The safety evolution continues.

fuses fuse holders CYLINDRICAL

Cylindrical fuse-link

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Fuse Blocks & Holders

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

MULTIVERT 250A Size 1, 690VAC

Cylindrical fuse-link

PANEL PANEL MOUNTING COMPONENTS

AF40... AF96 3-pole contactors Technical data

fuse holders & bases

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

Control Circuit Protection

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

Fuse switch disconnectors

Section Contents. Disconnect Switches

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

Compact Circuit Protector (CCP)

Electronic overload relays EF205 and EF370

UL 508 Non-Fusible Disconnect Switches

IEC Low Voltage Products Module 4

Electronic overload relay EF65, EF96 and EF146

Compact Circuit Protector (CCP)

UL 508 Non-Fusible Disconnect Switches

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Compact Circuit Protector (CCP)

DX³ RCCBs - ID 4P up to 100 A

IEC Low Voltage General Purpose Protection

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

INDUSTRIAL CYLINDRICAL FUSE LINKS

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Breakers and Switches. Switches Switch-disconnectors OT and OTM

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

PowerLine OS Switch Fuses A, 690V

Phase + Neutral, neutral on left side

Switches Unlimited Phone: * Fax:

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Panel-mounting components

CYLINDRICAL. fuse holders

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Fuse switch disconnectors

For Info: Phone: Fax:

Phase + Neutral, neutral on right side

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality

Special Purpose Fuses

Switch-disconnectors OT , OETL 3150

fuse holders CYLINDRICAL1

Page 2-4 Page 2-8. Page Page 2-13

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Complete and reliable solar circuit protection

Non-Fused Load Break Switches FSSC, SX, SXDC, SC


A powerful way to manage your power distribution challenges. I Power Distribution Blocks

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

TX³ RCCBs 2P up to 100 A

Protistor size 120 gr 750VDC (IEC)

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

FUSE BASES NH FUSE BASES 690V 160A 160A

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Fuse Blocks & Holders

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Surge-Trap Pluggable STPT2 Series - 40kA

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

1489-M Circuit Breakers

Horizontal fuse disconnects

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Breakers and Switches. Switches Change-over and transfer switches

Practical and completely safe

Transcription:

UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards to an IP20 grade of protection, including fuse changing (with the flick of a finger). are available in 1, 2, 3 or 4 poles, with or without visual blown fuse indicator, in UL + IEC version. Multi-pole units can also be field assembled by ordering pin-ties assembly kit. In this size, the range also offers the possibility to use microswitches (supplied with the holders or ordered separately) to allow remote indication. UltraSafe range is made of tough and durable thermoplastic or thermoset material. TECHNICAL DATA OVERVIEW UL ratings AC 800 VAC, 125 A, 50 ka UL ratings DC 1000 VDC, 125 A, 100 ka Voltage AC 690 VAC Voltage DC 690 VDC Amper (A) 125 A SCCR 100 ka Mounting Installation on to DIN rails to EN 60717 Product Size for cylindrical fuse links 22x58 Number of Poles 1-pole, 2-pole, 3-pole, 1+N, 3+N Finger safe Degree of protection: IP20 Optional visual blown fuse indicator & microswitch DIN rail mounting Modular design Lockable Multi-pole assembly kit available Sealable in closed and open position Plastic material UL94V2 mini Flame retardant materials with glow wire flammability index to 960 C APPLICATIONS All circuits up to 750VAC for protection of motors, transformers, low voltage distribution, control circuits Non-load operation STANDARDS UL Recognized Component, UL4248, guide IZLT2, file E52283 CSA Certified C22.2, class 6225, file 32169 IEC 60269-2 and IEC 60947-3 RoHS Compliant Plastic material: NF 16101 & 16102 Requirement 2 Compliant EP.MERSEN.COM 1

PRODUCT RANGE UltraSafe fuse holders for 22x58 fuse links, without indicator Reference Number of poles/ phases Design Weight Package US221 US221 E331158 1 single pole 0.214 kg 6 US221N H331161 1 + N single pole + neutral conductor 0.45 kg 3 US222 K331163 2 double pole 0.44 kg 3 US223 R331169 3 triple pole 0.6425 kg 2 US223N X331174 3 + N triple pole + neutral conductor 0.91 kg 1 UltraSafe fuse holders for 22x58 fuse links, with indicator Reference Number of poles/phases Design Weight Package US223I US221I F331159 1 single pole 0.2166 kg 6 US222I L331164 2 double pole 0.435 kg 3 US223I S331170 3 triple pole 0.325 kg 2 UltraSafe fuse holders for 22x58 fuse links, with auxiliary microswitch Reference Number of poles/ phases Design Weight Package US222M US221M G331160 1 single pole 0.1533 kg 6 US221NM J331162 1 + N single pole + neutral conductor 0.4666 kg 3 US222M M331165 2 double pole 0.455 kg 3 US222M2 P331167 2 double pole 0.4633 kg 3 US223M T331171 3 triple pole 0.665 kg 2 US223M2 W331173 3 triple pole 0.67 kg 2 UltraSafe fuse holders for 22x58 fuse links, with indicator and auxiliary microswitch Reference Number of poles/phases Design Weight Package US221MI Z1006203 1 single pole 0.2166 kg 6 US222MI N331166 2 double pole 0.455 kg 3 US222M2I Q331168 2 double pole 0.4666 kg 3 US223MI V331172 3 triple pole 0.675 kg 2 US223M2I X1011974 3 triple pole 0.645 kg 2 EP.MERSEN.COM 2

TECHNICAL DATA US22 US22I US22M US22MI Size 22x58 22x58 22x58 22x58 Number of poles/phases 1, 1+N, 2, 3, 3+N 1, 2, 3 1, 1+N, 2, 3 1, 2, 3 UL ratings AC 800 VAC, 125 A, 50 ka 800 VAC, 125 A, 50 ka 800 VAC, 125 A, 50 ka 800 VAC, 125 A, 50 ka UL ratings DC 1000 VDC, 125 A, 100 ka 1000 VDC, 125 A, 100 ka 1000 VDC, 125 A, 100 ka 1000 VDC, 125 A, 100 ka Conventional free air thermal current with fuse links I th 125 A 125 A 125 A 125 A Power dissipation at I th 9.5 W 9.5 W 9.5 W 9.5 W Utilisation category AC20B/DC20B AC20B/DC20B AC20B/DC20B AC20B/DC20B Rated insulation voltage U i 750 V 750 V 750 V 750 V SCCR 100 ka 100 ka 100 ka 100 ka Rated impulse withstand voltage U<sub>imp</sub> 8 kv 8 kv 8 kv 8 kv Degree of protection IP 20 IP 20 IP 20 IP 20 Voltage limit for blown fuse indicator - 230 to 690V AC/DC - 230 to 690V AC/DC Indication System - with indicator with auxiliary microswitch with indicator and auxiliary microswitch Connection Max. tightening torque: 4Nm (35lbs-in) Rigid wire = 1.5-50mm² (16-1AWG) Multistrand wire = 35mm² (3AWG) PZ2 or flat 6.5x1.2mm screw drivers recommended (max. diameter 7mm) Max. tightening torque: 4Nm (35lbs-in) Rigid wire = 1.5-50mm² (16-1AWG) Multistrand wire = 35mm² (3AWG) PZ2 or flat 6.5x1.2mm screw drivers recommended (max. diameter 7mm) Max. tightening torque: 4Nm (35lbs-in) Rigid wire = 1.5-50mm² (16-1AWG) Multistrand wire = 35mm² (3AWG) PZ2 or flat 6.5x1.2mm screw drivers recommended (max. diameter 7mm) Max. tightening torque: 4Nm (35lbs-in) Rigid wire = 1.5-50mm² (16-1AWG) Multistrand wire = 35mm² (3AWG) PZ2 or flat 6.5x1.2mm screw drivers recommended (max. diameter 7mm) Operating temperature -25 C to +60 C -25 C to 60 C -25 C to 60 C -25 C to 60 C Storage temperature -25 C to +80 C -25 C à 80 C -25 C to 80 C -25 C to 80 C SPECIFIC USAGE CONDITIONS Ambient temperature >20 C 30 C 40 C 50 C 60 C Derating factor (I e) 1 0.95 0.9 0.8 0.7 No of poles (side by side) 1 to 3 4 to 6 >/= 7 Derating factor of current (I th) 1 0.95 0.9 Nominal current of fuse-link gr 50 A 63 A 80 A 100 A 125 A 135 A Max. operational current in fuse-holder 47 A 54 A 70 A 83 A 91 A 96 A Cable wire section 10 mm² 16 mm² 25 mm² 35 mm² 50 mm² 50 mm² EP.MERSEN.COM 3

DIMENSIONS on microswitch FUNCTIONS Indicator light kit for US22 With the indicator light a blown fuse can be quickly located if power is still on. 1. Carefully remove the cover with 2 screw drivers. 2. Slip the indicator light s to insert into the rails, being careful not to twist the contact tabs. EP.MERSEN.COM 4

3. Put the cover back on. Auxiliary microswitch functions Fuse melting: a fuse-holder containing a fuse with a striker sends out a signal when the fuse element melts. Pre-isolation: when opening the fuse-holder, the microswitch sends a signal before the opening of the main contacts. Presence: sends a signal when the holder is closed with no fuse in it. With the fuse in the handle closed state No fuse - Fuse blown in handle open Characteristics Rated insulation voltage: 250VAC Rated operational current following IEC 60947-5 & -1 Utilization category AC15: 4A/24V, 4A/48V, 3A/127V, 2.5A/240V Utilization category DC13: 3A/24V, 1A/48V, 0.2A/127V, 0.1A/240V Minimum operational current and voltage: 1mA/4V AC or DC Auxiliary microswitch is designed to operate equally well on dual-current (1mA 4V minimum) or medium-current (5A maximum) circuits. However, a given product should only be used to switch one type of circuit during its working life. Connection: Faston lugs EP.MERSEN.COM 5

Auxiliary microswitch can only be mounted on previously prepared fuse disconnectors. Use of the auxiliary microswitch for fuse melting requires the use of fuses with strikers. 1 auxiliary microswitch Auxiliary microswitch is designed to operate equally well on dual-current (1mA 4V minimum) or medium-current (5A maximum) circuits. However, a given product should only be used to switch one type of circuit during its working life. Connection: Faston lugs USMSW4 2 auxiliary microswitches USMSW4 + US1422BP 3 x USMSW4 EP.MERSEN.COM 6

ACCESSORIES Kit for multi phase connection Reference Design Package US22PAK F227958 links for connection of multipole units 10 multiphase connection kit Auxiliary Switches Reference Design Weight Package USMSW4 G227959 Auxiliary contact kit 1 pole US22 20 g 1 CMS22W2 B331201 Auxiliary microswitch kit 3 poles CMS22 32 g 1 CMS22W3 N331189 2 Auxiliary microswitches kit 3 poles CMS22 35 g 1 US1422BP F213629 Enlargement pin for auxiliary microswitch 1.5 g 10 US1422PTH J214138 Auxiliary microswitch assembly pin (between 2 kits) 0.5 g 10 Locking devices Reference Description Weight Package LOCK TBB1A TBB23A TBB1C TBB23C TAGLOCKUS22 T1015927 Locking kit (Tag and lockout) - 1 LOCK M223525 Padlock 0.475 kg 1 Power supply TBB1A TBB1C TBB23A TBB23C Reference Description Application Weight Package D210315 E210316 F210317 G210318 1 phase axial incoming power supply 1 phase lateral incoming power supply 2 & 3 phases axial incoming power supply 2 & 3 phases lateral incoming power supply Max. rms current 90A 10.1 g 50 Max. rms current 90A 10 g 50 Max. rms current 90A 23.3 g 50 Max. rms current 90A 23.1 g 50 EP.MERSEN.COM 7

ACCESSORIES Wiring bars / Insulated bus bars Reference Design Application Weight Package CMS22BB2F6 C210314 double pole CMS22BB1F12 B210313 single pole Max. rms current 150A, for installation of 6 modules Max. rms current 90A, for installation of 12 modules 295 g 5 81 g 5 Indication facilities Reference Description Weight Package CMS1422LHI A225653 Indicator light kit 10 g 1 EP.MERSEN.COM 8