WARREN COUNTY, N.Y. M/E REFERENCE

Similar documents
WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

SECTION ELECTRIC DISTRIBUTION

SECTION PANELBOARDS

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Submit manufacturer's literature and technical data before starting work.

SECTION DISTRIBUTION AND GROUNDING

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION MOTOR CONTROL

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Generator Fire Safety: Generator assemblies should be located outside the building.

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Design Standard. Purpose: Design Standard:

SECTION ENCLOSED CONTROLLERS

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Quik-Spec Coordination Panelboard Specifications

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

University of Houston Master Construction Specifications Insert Project Name

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

IN2 Enclosed Switches and Circuit Breakers

SECTION MOTORS & MOTOR CONTROLLERS

University of Houston Master Construction Specifications Insert Project Name

Ice Rink Renovation & New Clubhouse

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

BAC Custom Engineered Controls

SECTION MOTOR CONTROLLERS

CONTENTS. B. System Design and Performance Requirements

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

BUSWAY Low Voltage (Pow-R-Flex)

SECTION MOTOR CONTROLLERS

SECTION VARIABLE FREQUENCY DRIVE UNITS

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

3. Coils shall be of molded construction

SECTION 16483C ADJUSTABLE FREQUENCY DRIVE - CLEAN POWER (CPX)

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

AIR COOLED RECTIFIER SPECIFICATION S-50-A

Enclosures. See Section Typical Description

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2

Bussmann series Quik-Spec Coordination Panelboard

Fused Coordination Panelboard

Service Entrance Methods

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Multi-Pak Group Control

A. This section includes unit capacitors for power factor correction.

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

VERTICAL LIFT FIRE/BLAST DOORS

SECTION WIRING DEVICES

SIGNAL WORDS QUALIFIED PERSON

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

C1000 Series Automatic Cap Bank

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Pow-R-Line 3E Panelboard

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Busway Construction. Bus Bars

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Horizontal Circuit Switchers

Industrial Control Transformers

Horizontal Circuit Switchers

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Features, Benefits and Functions

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

VARIABLE FREQUENCY DRIVES

EMERGENCY GENERATOR SET

Transcription:

SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE A. All methods of construction, details of workmanship, that are not specifically described or indicated in the contract documents, shall be subject to the control and approval of the Owner's Representative. Equipment and materials shall be of the quality and manufacture indicated in their respective sections of the specifications. The equipment specified is based upon the acceptable manufacturers listed. Equipment types, device ratings, dimensions, etc., correspond to the nomenclature dictated by those manufacturers. Where "or equal" is stated, equipment shall be equivalent in every way to that of the equipment specified and subject to approval. All equipment shall be tested at the factory. Unless specified elsewhere, standard factory inspection and operational tests will be acceptable. B. Installation shall be in accordance with NFPA-70 (National Electrical Code), National Electrical Safety Code (NESC), state codes, local codes, and requirements of authority having jurisdiction. C. Equipment shall be designed, manufactured, assembled, and tested in accordance with the latest revisions of applicable published ANSI, NEMA, UL and IEEE Standards. 1.3 SUBMITTALS A. Submit the following equipment, materials, products, etc.: 1. Branch circuit panelboards. 2. Over-Current Device Information. 3. Motor starters, contactors and relays. 4. Disconnect switches. 5. Adjustable Speed Drives. 6. Submit settings and adjustments for Starters as recommended by starter and motor manufacturers, as follows: a. Where reduced voltage autotransformer type starters are called for, submit Autotransformer voltage tap settings and start-run time delay relay. ELECTRIC DISTRIBUTION 262000-1

PART 2 - PRODUCTS 2.1 MATERIALS b. Where "part winding" or "wye start, delta run," starters are called for, submit START-RUN time delay relay setting. c. Where special features are called for, submit voltage taps and settings, resistor adjustments, time delay relay settings. d. Where time delay relays are called for to achieve staggered restarts upon restoration of failed electric power, submit time delay relay settings. 7. Submit documentation of all grounding tests. A. Branch Circuit Panelboards (208Y/120 volt): 1. Provide branch circuit panelboard as indicated in the "Panelboard Schedule" and as located on the drawings. Panelboards shall be equipped with quick make/quick break thermal-magnetic, molded case circuit breakers as scheduled. 2. Panelboard bussing and lugs shall be copper. Provide grounding bus in each panelboard, securely bonded to the box. Panelboard bus structure and main lugs or main circuit breaker shall have current ratings as indicated. Such ratings shall be established by heat rise tests, conducted in accordance with UL Standard 67. 3. Provisions for additional circuit breakers shall be such that field addition of connectors or mounting hardware will not be required to add circuit breakers to the panelboard. Bus connections shall be bolt-on. 4. Each panelboard, as a complete unit, shall have a short circuit current rating equal to or greater than the rating shown on the Panelboard Schedule or on the plans. All panelboards shall be fully rated. "Series Ratings" are NOT acceptable. Reducing breaker ratings on the basis of series rating is not acceptable. 5. The panelboard bus assembly shall be enclosed in a steel cabinet. The rigidity and gauge of steel to be specified in UL Standard 50 cabinets. Wiring gutter space shall be in accordance with UL Standard 67 for panelboards. Each front shall include a door and have a flush, stainless steel, cylinder type lock with catch and spring-loaded door pull. All panelboard locks shall be keyed alike. Doors shall be mounted by completely concealed steel hinges. A circuit directory frame and card with a clear plastic covering shall be provided on the inside of the door. Fronts shall be of code gauge, full-finished steel with rust inhibiting iron phosphate sealer and baked enamel finish. Minimum box width shall be 20 in. Provide door-in-door construction. Provide corbin locks keyed to match the Owner's existing system. Provide full length piano-hinged trim allowing access to wiring gutters without removal of trim. 6. Ratings shall be as indicted on the Panelboard Schedule. ELECTRIC DISTRIBUTION 262000-2

7. Manufacturers: Subject to compliance with Contract Documents, the following B. Circuit Breakers: a. 208Y/120 Volt: 1) Square D "NQOD" - Design Make. 2) Eaton Corporation "PRL1". 3) General Electric "AQ". 4) Siemens. 1. Circuit breakers below 400 amp frame shall be molded case with inverse time and instantaneous tripping functions, unless indicated otherwise in contract documents. 2. Branch circuit breakers shall be quick-make, quick-break, thermal-magnetic and trip indicating, and multipole breakers shall have common trip. 3. Ratings shall be as indicated in the Contract Documents. 4. Manufacturers: Subject to compliance with contract documents, the following C. Motor Starters: a. Square D Micrologic trip unit - Design Make. b. Eaton Corporation Optim 550 trip units for circuit breakers 400-1600 amp frame or RMS 610 trip units for 2000 amp frame to 6000 amp frame.. c. General Electric Spectra RMS or MicroVersa trip unit. d. Siemens Sentron Sensitrip III trip unit. 1. Provide motor starters, disconnect switches, etc. as listed on the Electric Equipment and Control Schedule on the drawings. 2. Starters, contactors and controllers shall comply with NEMA standards having general purpose NEMA 1 or 1B enclosure unless otherwise called for. Provide explosion proof, weather resistant or watertight construction as required. Starters shall be minimum NEMA size 0 with solid state overloads in each phase sized per NEC, motor full load amperage, service factor, and motor operating conditions. 3. Pad lock arrangements shall be provided to lock the disconnect device in the "off" position. Magnetic starters shall be provided with a control power ELECTRIC DISTRIBUTION 262000-3

transformer with 120V secondary and primary and secondary fusing and be sized to accept the loads imposed there on. Starters shall have LED type pilot lights. Each starter subject to electrical interlock and/or automatic control shall have necessary auxiliary contacts. 4. Auxiliary Devices: Provide pushbutton stations, pilot lights, devices, relays, transformers, selector switches, electric thermostats, auxiliary starter contacts as required for functions called for. Provide separate relay for each speed to operate electric dampers or other devices as required for multispeed motor circuit. 5. Magnetic Starter: Shall be single-speed, across-the-line type rated in accordance with NEMA standards, sizes and horsepower ratings. Starters shall be mounted in NEMA 1 enclosures unless otherwise indicated. Magnetic starters shall be equipped with double break silver alloy contacts; all contacts shall be replaceable without removing starter or disconnecting power wiring. Starter shall have straight-through wiring. Coils shall be of molded construction and shall be replaceable from the front without removing starter. Overload relays shall be solid state type with replaceable control circuit module. Thermal units shall be of one-piece construction and interchangeable. Starter shall be inoperative if thermal unit is removed. Provide hand-off-auto selector switch, and start-up pushbuttons and "run" pilot light in cover. Wire for maintained contact unless otherwise noted. 6. Combination Magnetic Starter: Shall be similar to "Magnetic Starter", above, except shall include fusible disconnect switch connected ahead of starter. The disconnect handle shall be in control of the disconnect device with the door open or closed. Disconnect handle shall be clearly marked as to whether the disconnect device is "on" or "off". 7. Packaged Control Unit: Shall be furnished and mounted by others, and installed and connected by Electrical Contractor. Generally consists of one or more starters, disconnect switches and additional control devices prewired. 8. Contactor: Shall be similar to "Magnetic Starter", above, except without thermal overload units. 9. Manufacturers: Subject to compliance with contract documents, the following a. Square-D - Design Make. b. Cutler Hammer. c. General Electric. d. Allen-Bradley. e. Siemens. D. Disconnect Switches: ELECTRIC DISTRIBUTION 262000-4

1. Shall be heavy-duty type three-pole, with "Quick Make/Quick Break" operating handle mechanically interlocked with the cover, horsepower and voltage rated to match equipment served. Where indicated switches shall be provided with dualelement, time delay, rejection type fuses. Switches shall be installed in NEMA 1, General Purpose Surface Enclosures, unless otherwise noted. Provide provisions for padlocking in the "off" position. Provide neutral bar in single phase or three phase, four wire circuits, and ground bar in all switches. Provide auxiliary contacts where called for. 2. Manufacturers: Subject to compliance with Contract Documents, the following a. Square-D - Design Make. b. Cutler Hammer. c. General Electric. d. Siemens. E. Adjustable Speed Drive (ASD): 1. The ASD shall be 5 HP minimum size, UL Listed, NEMA standard frame size for horsepower rating indicated including 115% motor service factor. Short circuit rating shall be 42kA minimum. Integral solid state programmable overload relay with selectable time class (10, 20 or 30) shall be provided. 2. Units shall be wall or floor mounted as suitable for the intended location. Units shall be an integral component of a motor control center where indicated. Units shall be in NEMA 1 enclosure. 3. The unit shall be provided with a 120V control power transformer. The control power transformer shall be provided with primary and secondary fusing. 4. Cooling fans shall have removable washable filter. 5. Unit shall be of six (6) pulse design with separate common mode choke on the input and output of the drive, if not already built in the unit to minimize total harmonic distortion. Provide with 5% input line reactor. 6. The allowable conductor length between the unit and the controlled motor shall be 100 feet. Ambient temperature range shall be 0 to 40ºC with a 3300' altitude. 7. Provide a dv/dt filter to minimize voltage doubling at the motor terminals caused by excessively long motor conductors from the ASD. The dv/dt filter shall be installed at the ASD unit, preferably in the same enclosure as the ASD. The dv/dt filter shall be factory installed in the ASD. 8. Door mounted selector switch for Auto-Manual control. In the auto mode, the start command and speed control shall be provided from a remote source. In the manual mode, the start-stop and speed control shall be provided through the door ELECTRIC DISTRIBUTION 262000-5

F. Fuses: mounted controls. Provide extra contact blocks on the selector switch for monitoring of switch position. 9. Door mounted pushbuttons for start-stop control. Stop pushbuttons shall always be active. Door mounted LED type pilot lights for indication of On (Red) and Off (Green). Door mounted human interface module for programming, display and speed control. 10. Programming shall include: a. One isolated, configurable analog input. b. Two isolated, configurable analog outputs. c. Alarm digital input for automatic shutdown, field configurable for ramped deceleration, full stop and manual/auto reset. Digital input to force unit to a preprogrammed speed for smoke control or other need. d. Four field programmable digital outputs. 11. Field selectable isolated process control interface to enable the ASD to follow 0-5 ma, 1-5 ma, 4-20 ma, 10-50 ma, 0-8 VDC, 1-4 VDC, or 0-10 VDC grounded or ungrounded signal from a process controller. Provide RS232 or RS485 communication module board. 12. Network connection shall be suitable for unit on/off and speed control. Communication to the building control system shall include actual motor speed verification, amperage, voltage, kw, and kwh. All unit programming functions shall be accessible through network communication. Communication shall be selectable for BACnet, Metasys, Modbus, Lonworks, Profibus and the project building control system. 13. Isolation Disconnect Switch: Provide isolation disconnect switch integral to unit with a provision for padlocking in the "Off" position. 14. Design Make: Allen Bradley Powerflex 700. 15. Make: Allen Bradley, Eaton Corporation, Square D, General Electric, ABB, Emerson or approved equal. 1. All fuses rated 600 volts and below shall be rejection type dual-element, timedelay type. Provide two (2) complete sets of fuses for all fusible disconnect switches. Deliver spare fuses to the Owner and obtain receipt. 2. Manufacturers: Subject to compliance with Contract Documents, the following a. Fuses 600 Amperes and Below: Bussman Type FRS-R (600 volts), Bussman Type FRN-R (300 volts) or equivalent. ELECTRIC DISTRIBUTION 262000-6

PART 3 - EXECUTION 3.1 INSTALLATION b. Fuses Rated Above 600 Amperes: Bussman Type KRP-C or equivalent. A. All equipment shall be grounded per the NEC. B. Electrical distribution equipment shall have lugs/terminations suitable for the indicated conductor size. Where conductors have been oversized for voltage drop and where approved by the Engineer it shall be allowed to reduce the conductor size using hydraulically crimpled splice in a box next to the distribution equipment to allow for standard lug termination. C. Motor Starters: 1. Coordinate overload and fuse sizes with Division 23 Contractor. 2. Coordinate termination of control wiring with Division 23 Contractor. D. Adjustable Speed Drives: 1. Set in place controllers on 4 in. high concrete base, on wall or freestanding steel frame as required. Completely erect and assemble, including shipping splits and make respective connections from terminal or terminal strips to any miscellaneous control devices. 2. Provide respective line side power supply connections to load side power terminals. Adjust unit controls in accordance with manufacturer's instructions. 3. Adjust unit controls in accordance with manufacturer's instructions. 4. A factory-trained manufacturer's service representative shall provide complete start-up services at the site during construction plus a separate (after startup on a 100% correctly operating drive) 4 hour training session for the Owner. Coordinate start-up and controls with Division 23 Contractor. 5. Equipment manufacturer to provide a one (1) year full parts and labor warranty from date of start-up and Owner acceptance. E. Identification: 1. Identify all items of equipment as described in Section 260501-3.1, Identification. 3.2 ELECTRICAL LOAD TEST A. Conduct a load test prior to request for final payment and comply with the following: 1. Energize maximum normal light and power load for a period of two hours when scheduled. ELECTRIC DISTRIBUTION 262000-7

3.3 SPARE PARTS 2. Record voltage at service and at each panel. 3. Measure current in each phase of all feeders. 4. Provide and install all necessary metering equipment. 5. Owner's Representative or Site Representative shall witness the test. 6. Before final acceptance specified test shall be completed to the satisfaction of the Owner's Representative who shall be sole judge of the acceptability of such tests and who may direct the performance of such additional tests as deemed necessary in order to determine the acceptability of the systems, equipment, material and workmanship. Additional tests required by the Owner's Representative shall be provided at no additional cost. Protective equipment shall be actuated in a manner that clearly demonstrated their workability and operation. A. Deliver loose equipment to the Owner and obtain receipt for fuses, keys to panelboards, etc. END OF SECTION ELECTRIC DISTRIBUTION 262000-8