Section 8 Stab-lok Circuit Breakers

Similar documents
Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Section 4 Square D QO Loadcentres

Section 2 HomeLine Loadcentres

GFCI-AFCI FAQ. Where are AFCIs and GFCIs required?

CH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Loadcentres. 4 Loadcentres. Product Offering and Specificaton Guide. Description. Application

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Electrical Equipment and Terminology

Contents. 4 Loadcentres

ELECTRICAL SAFETY. Safety Training For The Non-Qualified

ELECTRICAL. 60 Minutes

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

Retail Reference Guide

FACT SHEET Standard: Electrical Safety

FILE HOW TO REPLACE A GFCI BREAKER ARCHIVE

Section 1. Load Centers and Circuit Breakers. Section Updated 11 / 2014

IN2 Enclosed Switches and Circuit Breakers

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Lighting and Power Distribution Panelboards

SECTION PANELBOARDS

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

Chapter 4 Utility Systems Electrical

New Products for Integrated Electrical Systems/Questions and Answers/Resources. necdigest. Bringing a new level of electrical protection into the home

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Control Circuit Protection

CHAPTER V RESIDENTIAL WIRING

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Electricity Merit Badge

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Circuit Concepts (Residential)

INSTALL CIRCUIT PROTECTIVE DEVICES

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

Electrical Safety. Recognizing & Controlling Hazards

T H QL Recommendations based on standard conditions. Installation must conform to all local and national codes.

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

Chapter 8 Interior Wiring and Lighting

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Introduction. Upon completion of Basics of Circuit Breakers you will be able to: Explain the need for circuit protection

Bussmann series Quik-Spec Coordination Panelboard

Electrical Safety. Introduction

5SM6 AFD Units Advanced Preventative Fire Protection

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

Basic Electrical Safety

Plugs and Receptacles: Hazardous Location

PB-Series. GFCI/ELCI & Panel Seal

DOC / SQUARE D BREAKER BOX HINGES DOWNLOAD

ECET Distribution System Protection. Overcurrent Protection

New DX 3 High rating & breaking capacity

SAFE REPLACEMENT BREAKERS BUILT TO LAST

UPFRO. Residential Electric. Voltage & Amperage

Table of Contents. Review Answers...84 Final Exam...85 quickstep Online Courses...88

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

OVERHEAD SERVICE. Items to consider

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

PowerPact B. Molded case circuit breakers and switches from A

Spring-loaded cover seats against neoprene gasket.

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Knowledge Objectives (3 of 3) Electricity. Skills Objectives (2 of 2) 12/20/2013

Learning Module 10: Loadcenters. 101 Basic Series

22,000 A IR Catalog Number QA115AFCH QA120AFCH Q215AFCH Q220AFCH. 65,000 A IR Catalog Number QA115AFCHH QA120AFCHH QA115AFH QA120AFH

Unit 3 Lesson 3 Electric Circuits. Copyright Houghton Mifflin Harcourt Publishing Company

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

UNDERSTANDING ELECTRICAL EQUIPMENT AND CONDITIONS OF INCREASED RISK

Service Entrance Methods

PROTECTION OF THE BRANCH CIRCUIT

Modifications. Marine 50 C Ambient Calibration

Quik-Spec Electrical Gear

Chapter 5. Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI)

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

Cutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine

Understanding Electricity and Electrical Safety Teacher s Guide

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Fee $20 Course: NEC Changes 1 This course is valid for these credentials: Credential Description Cred Code Credit Hours

Electrical Safety For Everyone. Leader s Guide

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

TRANSMISSION SYSTEMS

CAL/OSHA ELECTRICAL LOW VOLTAGE

A. Submit manufacturer's literature and technical data before starting work.

Ten Deadly Conditions to Check for in Your Boat's Electrical System - Part 2

SECTION MOTOR CONTROL

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC

Why is the Breaker Tripping?

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Transcription:

Section 8 Stab-lok Circuit Breakers Stab-lok easier to work with and faster to install Stab-lok breakers are fully interchangeable with all past breakers and deliver the same proven quality. The unique Stab-lok breaker design of only a 1/2 wide per pole, allows for the reduction of the size and weight of the loadcentre. These breakers are CSA approved to work only in Federal Pioneer branded residential panels. Stab-lok breakers are easily identifiable by their unique architectural white colour and colour handles. Stab-lok Breaker Features: y Provides overload and short circuit protection. y Colour coded handles: identification is quick and easy with separate colours representing different ampere ratings. y Provides Slot/Robertson screws. y Thermal magnetic trip protection. y Calibrated at 40 degrees Celsius. y Arc resistant case. 2 Pole Stab-lok breakers must be installed across the black dividers on the busbar for 240V output voltage. Retail Catalogue - Schneider Electric 49

Circuit Breaker Product Selection Guide Plug-On Circuit Breakers Selection - 10,000 AIR Type Lug Range Two Pole 240 Vac Lug Range 15 A NC015CPu NC0215CP 20 A NC020CPu NC0220CP #14-#6 #14-#6 25 A NC025CP NC0225CP NC 30 A NC030CP NC0230CP 40 A NC040CP NC0240CP 50 A NC050 #14-#4 NC0250CP #14-#4 15 A NA15CPu NA215CP 20 A NA20CPu NA220CP 25 A NA25 #14-#2 NA225CP 30 A NA30 NA230CP #14-#2 40 A NA40 NA240CP 50 A NA NA50 NA250CP 60 A NA260CP 70 A NA270CP 100 A NA2P100CP #4-2/0 125 A NA2P125CP #4-2/0 150 A NA2P150CPv #4-2/0 Stab-lok Breaker 1 Space Required usingle Pole 15 A and 20 A breakers are Switching Duty Rated (SWD). Suitable for switching fluorescent lighting loads. vna2p150 rated 150 A when used with copper conductor only. Notes: - 1 Pole NA breakers take 2 NC breaker spaces. - 2 Pole NA breakers take 4 NC breaker spaces. - Use solid conductor only when #14 wire is used. Stab-lok Two Pole Breaker Colour coded breaker handles: NC015CP/NC0215CP - Black/Blue NC020CP/NC0220CP - Red NC030CP/NC0230CP - Green NC040CP/NC0240CP - Grey Greater than 50A breakers - Black Stab-lok Two Pole (NA) Breaker 4 Spaces Required 50 Retail Catalogue - Schneider Electric

Stab-lok TM Ground Fault Breakers The Federal Pioneer ground fault circuit interrupter protects people against electrical shocks. GFCI protection is required in wet or damp areas such as bathrooms, kitchens, garages, spas, pools and outdoor receptacles. Stab-lok Ground Fault Circuit Breaker Features: y Provides overload, short circuit protection combined with Class A ground fault protection. y Class A denotes a GFCI that will trip when a fault current to ground is 5 milliamperes or more. y 10,000 eres Interrupting (AIR). y Red push to test button. y Use solid conductor only when #14 wire is used. Plug-On Ground Fault Circuit Breakers Selection GFI with 5 ma Sensitivity (Class A) Two Pole Common Trip 240 Vac 15 A NAGF15CP* OBS 20 A OBS OBS 30 A OBS OBS 40 A OBS OBS NA GFI Breaker Notes: - Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. - Submersible pump installations require ground fault protection to the maximum sensitivity level of 10mA. * Obsolete when stock = 0 NA Two Pole GFI Breaker 4 Spaces Required GFCI breakers detect small amounts of current mismatch between the neutral and hot conductors. Retail Catalogue - Schneider Electric 51

Stab-lok TM Arc Fault Breakers Featuring exclusive digital technology, the Stab-lok D Arc Fault Circuit Interrupter (AFCI) detects overloads, short circuits and arc-faults. The AFCI effectively stops the flow of current before an electrical fire can start. An arc fault is an unintended arc created by current flowing through an unplanned path. Arcing creates high intensity heating at the point of the arc and as a result, burning particles may be expelled that may easily ignite surrounding materials, such as wood framing or insulation. The temperature at the center of these arcs can exceed 10,000 F. Stab-lok Arc Fault Circuit Breaker Features: y Detects unintended arc faults, overloads and short circuits. y Patented digital technology to provide unequaled protection against electrical fires. y Requires 2 spaces in loadcentre. y Green push to test button. y Familiar installation procedure - Installation is similar to that of a ground-fault circuit interrupter. Plug-On Arc Fault Circuit Breakers Selection 10,000 AIR 15 A NA15AFICP 20 A NA20AFICP 15 A Arc Fault Breaker Typical Causes of Dangerous Arc Faults in a Residence Nails or screws carelessly driven into walls Drywall Screw Piercing Insulation Punctured Cable by Nail or Staple Cords Caught in Door Jams What is the difference between AFCI and GFCI? A GFCI is a people protection breaker. It is used to protect people from energized parts connected to receptacles. The AFCI is a fire prevention breaker. It is used to protect against faults or damage to wiring and equipment that could start fire causing arcing in the circuit. 52 Retail Catalogue - Schneider Electric

Stab-lok TM Main Breakers Stab-lok Main Breaker Features: y Provides option for padlock in OFF position. y Bolt on main breaker for Stab-lok service entrance panels. Bolt on Main Breaker Selection ere Type Part Number Lug Wire Size 60 A 1C 1C60 #4-2/0 100 A 1C 1C100 #4-2/0 125 A 1C 1C125 #4-2/0 100A Main Breaker Stab-lok TM Accessories Accessory Selection Accessory Description Catalogue Number Filler Plates Fills branch breaker openings in cover PF1CP PF1CP Replacement Amalgamated Electric Fuse Holders Twin Single Pole Plug-In Head 15 to 30A Two Pole Plug-In Fuse Head 15 to 30A 7301CP 7302CP 7301CP 7302CP Handle Tie Suitable for square handled NC breakers. HTNCCP Handle Lock Off Handle Tie Non-Padlocking Suitable for ribbed handled NC 1 + 2 pole breakers. NC-LOK HTNCCP NC-LOK Retail Catalogue - Schneider Electric 53