Position Switches Series 8074/2

Similar documents
Position Switches Series 8060/2

Position Switches Series 8070/2

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Load disconnect switch Series 8146/5-V11

Metal Position Switch Series 8074

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Control Buttons / Switches for Panel Mounting Series 8003

Control switch/load disconnect switch Series 8008

Load and Motor Switches, Load-Break Switches Series 8549

Plug and Socket Devices SolConeX 16 A Series 8570

Load and Motor Switches, Load-Break Switches Series 8544

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Floodlight LED Series 6125

Load and Motor Switches, Load-Break Switches Series 8544

Safety Switches Series 8537

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Compact Sheet-Steel Light Fittings Series 6114/1

Floodlight LED Series 6525

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6402/2

Floodlight Series 6521/4

Linear luminaire with LED Series EXLUX 6002

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Floodlight LED Series 6525

Control Buttons Series 8082

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Floodlight Series 6121

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Emergency Luminaire with LED Series EXLUX 6409/1

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

LED Linear Luminaire Series EXLUX 6402

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Ex UPS standard Series 8265

Terminal Boxes Series 8125

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Terminal Boxes Series 8252/1

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Tubular Light Fitting with LED Series 6036

11 Control Panels, Distribution Panels and Components

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Battery Boxes Series 8316

Safety switches / Position switches / Command devices

YFC. Limit switch. Ex d. 24 operating head types

M-0. M-0... series control, monitoring and signalling devices. Ex e

Safety switches with separate actuator

FL series position switches

Sheet-Steel Light Fittings Series 6014 / 6414

Safety switches with separate actuator

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

10 Load and Motor Switchgear

Limit Switch - Prewired Type Metal Body

Terminal Boxes Series 8125

Safety switches for hinges

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Linear fluorescent luminaire LED V-CG-S

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Operating Instructions

ABG Cable Glands Installation Procedure

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Tank Inspection Lights Series 6122

Floor and fine adjustment switches

Compact Sheet-Steel Light Fittings Series 6114

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

HTSB system System overview

Junction boxes for control, monitoring and control panel Ex tb

Direct-acting 3/2 way plunger valve

Limit Switches - Limit Type Plastic Body IP65

Position switches FD series

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Solenoid coil for control in potentially explosive areas Type BZ

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Safety rope switches with reset for emergency stop

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Safety rope switch with reset for emergency stop

Resistance thermometer Without thermowell Model TR10-H

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

Sheet Steel Emergency Light Fitting Series 6018

LR-LX-LK-LW Safety Switches with separate actuator

Transcription:

www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators, which can be offset by 4 x 90. > Safety position switch of Category 1 with different actuators > Replaceable contact elements with: Snap-action contact Slow-action contact Overlapping slow-action contact Positive- contacts Flameproof enclosure 18905E00 Position switches are used to position, control and monitor the moving parts on machines and systems. Because they meet the requirements of the EN 50 041 and IEC 60947-5-1 product standards, they can also be used as a position switch with a safety function. Position switches of the 8074/2 series are permitted to be used in hazardous areas of zones 1, 2, 21 and 22. In conjunction with a safety door guard and the corresponding circuitry, the PL position switches reach "e" in accordance with EN ISO 13849-1, or up to SIL 3 in accordance with EN 62061. They are identified with the character for positive. There are snap- and slow-action versions with different types of contacts as well as with a variety of different actuating elements. ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x WebCode 8074D Control Devices /1

Selection Table Version Actuator Normally open contacts Order number Art. no. Weight 18920E00 18917E00 Plunger Roller Misalignment switch Plunger with sealing collar Roller made of moulded material Roller made of moulded material kg 1 NO + 1 NC 8074/2-1-W-40 257197 0.298 1 NO + 1 NC snap-action 8074/2-2-W-40 258054 contact with spring 2 NC 8074/2-3-W-40 257203 1 NO + 1 NC overlapping 8074/2-5-W-40 257212 1 NO + 1 NC 8074/2-1-R-40 257184 0.299 1 NO + 1 NC snap-action 8074/2-2-R-40 258055 contact with spring 2 NC 8074/2-3-R-40 257204 1 NO + 1 NC overlapping 8074/2-5-R-40 257213 1 NO + 1 NC 8074/2-1-SR-40 257201 0.486 1 NO + 1 NC snap-action 8074/2-2-SR-40 258062 contact with spring 18918E00 Long rotary lever Roller made of moulded material 1 NO + 1 NC 8074/2-1-DL-40 257188 0.422 1 NO + 1 NC snap-action 8074/2-2-DL-40 258059 contact with spring 2 NC 8074/2-3-DL-40 257208 1 NO + 1 NC overlapping 8074/2-5-DL-40 257217 18915E00 18921E00 18922E00 18913E00 Roller lever Parallel roller lever Rocking lever Roller made of moulded material Roller made of moulded material Roller made of moulded material 1 NO + 1 NC 8074/2-1-WH-40 257185 0.300 1 NO + 1 NC snap-action 8074/2-2-WH-40 258056 contact with spring 2 NC 8074/2-3-WH-40 257205 1 NO + 1 NC overlapping 8074/2-5-WH-40 257214 1 NO + 1 NC 8074/2-1-WPH-40 257186 0.307 1 NO + 1 NC snap-action 8074/2-2-WPH-40 258057 contact with spring 2 NC 8074/2-3-WPH-40 257206 1 NO + 1 NC overlapping 8074/2-5-WPH-40 257215 1 NO + 1 NC 8074/2-1-D-40 257187 0.360 1 NO + 1 NC snap-action 8074/2-2-D-40 258058 contact with spring 2 NC 8074/2-3-D-40 257207 1 NO + 1 NC overlapping 8074/2-5-D-40 257216 /2 Control Devices

Selection Table Version Actuator Normally open contacts Order number Art. no. Weight kg Adjustable Roller made 1 NO + 1 NC 8074/2-1-DS-40 257189 0.386 rocking lever of moulded material 1 NO + 1 NC snap-action Roller rod contact with spring 8074/2-2-DS-40 258060 made of stainless steel 2 NC 1 NO + 1 NC overlapping 8074/2-3-DS-40 8074/2-5-DS-40 257209 257218 Note 18916E00 18914E00 18912E00 Rod lever Safety switch, separate actuator No positive, not suitable for safety circuits! Rod made of moulded material No positive, not suitable for safety circuits! Separate actuator made of metal (please order separately) The actuators are included, but not installed 1 NO + 1 NC 8074/2-1-DD-40 257190 0.340 1 NO + 1 NC snap-action 8074/2-2-DD-40 258061 contact with spring 2 NC 8074/2-3-DD-40 257210 1 NO + 1 NC overlapping 8074/2-5-DD-40 257219 1 NO + 1 NC 8074/2-1-AZ-20 257202 0.340 2 NC 8074/2-3-AZ-20 257211 Control Devices /3

Explosion Protection Global (IECEx) Gas and dust IECEx BVS 16.0085 Ex d e IIC T6... T5 Gb Ex tb IIIC T80 C Db Europe (ATEX) Gas and dust BVS 05 ATEX E 007 E II 2 G Ex d e IIC T6... T5 Gb E II 2 D Ex tb IIIC T80 C Db Certifications and certificates Certificates IECEx, ATEX, Russia (TR) Technical Data Version Electrical data Rated al voltage U e 8074/2-.-W, -R, -SR, -DL, -WH, -WPH, -D, -DS, -DD 8074/2-1 8074/2-2 8074/2-5 8074/2-3 Alternating voltage for equal potential: Alternating voltage for unequal potential: Direct voltage: max. 500 V max. 250 V 125 V max. 400 V max. 250 V 125 V Rated al current I e Switching capacity Rated insulation voltage Rated impulse withstand voltage Short circuit protection Ambient conditions Operating temperature range 4.4 A: +70 C (T6); 6.6 A: +70 C (T5) AC-12 AC-15 DC-12 8074/2-1 8074/2-2 8074/2-5 max. 250 V max. 500 V **) max. 4 A max. 5000 VA 550 V 4 kv 6 A (time lag) -40 to +70 C, T6 (max. 4.4 A) -40 to +70 C, T5 (max. 6.6 A) 8074/2-3 8074/2-1 8074/2-2 8074/2-5 max. 250 V max. 400 V **) max. 4 A max. 4000 VA **) only with the same potential max. 250 V max. 500 V **) max. 4 A max. 1000 VA 8074/2-3 8074/2-. max. 250 V max. 400 V **) max. 4 A max. 1000 VA max. 125 V max. 4 A max. 400 W Technical Data Version Electrical data Rated al voltage U e Rated al current I e Switching capacity Rated insulation voltage Rated impulse withstand voltage Short circuit protection Ambient conditions Operating temperature range 8074/2-.-AZ-20 Alternating voltage: Direct voltage: max. 6 A: -20 C < Ta < +60 C, 250 V AC; max. 0.25 A: -20 C < Ta < +60 C, 230 V DC AC-15 max. 250 V max. 6 A 250 V 4 kv 6 A gn / gg -20 to +40 C (T6) -20 to +60 C (T5) 8074/2-.-AZ-20 250 V AC 230 V DC DC-13 max. 230 V max. 0.25 A /4 Control Devices

Technical Data Version 8074/2-.-W, -R, -SR, -DL, -WH, -WPH, -D, -DS, -DD, -AZ-20 Mechanical data Maximum switching max. 1800 operating cycles/h frequency Degree of protection IP66-40 C (DIN EN 60529) Mechanical shock Snap-action contact: 2 g resistance Slow-action contact: 20 g Material Enclosure Cover Mounting / Installation Cable entries Corrosion-resistant aluminium, powder-coated Similar to RAL 7016 1.4401 stainless steel, blasted 8161/7-M20.. on the enclosure bottom: 1 x M20 x 1.5 Connection with cable entry 8161: For sheathed cable 4 x 2.5 mm 2 (Ø 4 to 13 mm); 4 x 1.5 mm 2 recommended Terminals 0.75 to 2.5 mm 2, 0.75 to 1.5 mm 2 (8074/2-.-AZ-20) solid, finely stranded with or without core end sleeve; additional outer protective conductor connection up to max. 4 mm 2 Tightening Screw terminals: 0.4 Nm max. Cover screws: 1.5 to 2 Nm Cable entries: See installation note (enclosed unattached) Contact Version Slow-action contact Snap-action contact Slow-action contact, overlapping 8074/2-1 08667E00 8074/2-2 08668E00 8074/2-5 08675E00 Contact arrangement Contact Material Contacts Enclosure contact Service life Mechanical electrical 8074/2-3 08669E00 2-pole, galvanically separated with double break ) 1.5 mm (isolating distance ) 3 mm) Silver-nickel Polyamide, glass fibre reinforced max. 10 6 operating cycles max. 10 6 operating cycles Caution: The positive function depends on the actuator Control Devices /5

Type 8074/2 V Max. operating speed Positive Plunger 8074/2-.-W-40 For lateral actuation: V 0.5 m/s Actuation in stroke direction: V 1.0 m/s 07695E00 07696E00 07697E00 Positive distance In stroke direction 8074/2-2: 8074/2-3: 8074/2-5: 18998E00 19051E00 18999E00 22 N 07699E00 19000E00 18822E00 /6 Control Devices

Type 8074/2 V Max. operating speed Positive Roller plunger 8074/2-.-R-40 For lateral actuation: V 1.0 m/s Actuation in stroke direction: V 1.0 m/s 07695E00 07696E00 07697E00 In stroke direction 8074/2-2: 8074/2-3: 8074/2-5: Positive distance 18998E00 19051E00 18999E00 22 N 07699E00 19000E00 18820E00 Control Devices /7

Type 8074/2 V Max. operating speed Positive Misalignment switch 8074/2-.-SR-40 Positive distance Only for use with snap-action contact! 2.5 N 07695E00 45 32 47 75 19060E00 8074/2-2: 75 07696E00 19061E00 18821E00 /8 Control Devices

Type 8074/2 V Max. operating speed Positive Long rotary lever 8074/2-.-DL-40 Positive distance 3 N 32 47 75 45 07695E00 8074/2-2: 19060E00 07696E00 8074/2-3: 75 19061E00 32 75 07697E00 47 19062E00 8074/2-5: 32 45 75 07699E00 62 19064E00 18818E00 Control Devices /9

Type 8074/2 V Max. operating speed Positive Roller lever 8074/2-.-WH-40 V 1.0 m/s Positive distance Displacement of the roller in the stroke direction of the plunger at the start of the plunger movement 18 N 07695E00 07696E00 8074/2-2: 2,4 3,7 6 mm 3,6 mm 8074/2-3: 19054E00 19055E00 07697E00 2,4 6 mm 3,7 mm 8074/2-5: 19056E00 07699E00 2,4 3,6 6 mm 5,0 mm 19057E00 18823E00 /10 Control Devices

Type 8074/2 V Max. operating speed Positive Parallel roller lever 8074/2-.-WPH-40 V 1.0 m/s 07695E00 07696E00 07697E00 07699E00 Displacement of the roller vertically in the stroke direction of the plunger at the start of the plunger movement 8074/2-2: 8074/2-3: 8074/2-5: Positive distance 2,4 3,6 6 mm 5,0 mm 19004E00 19059E00 19005E00 19057E00 18 N 18824E00 Control Devices /11

Type 8074/2 V Max. operating speed Positive Rotary lever 8074/2-.-D-40 V 1.5 m/s 07695E00 8074/2-2: Positive distance 19006E00 7 N 07696E00 07697Eoo 8074/2-3: 8074/2-5: 75 19061E00 19007E00 75 07699E00 19008E00 18816E00 /12 Control Devices

Type 8074/2 V Max. operating speed Positive Adjustable rotary lever 8074/2-.-DS-40 V 1.5 m/s Positive, not suitable for safety circuits 07700E00 8074/2-2: Positive distance 19006E00 4.5 N 20214E00 07702E00 8074/2-3: 8074/2-5: 75 19061E00 19007E00 07703E 75 19008E00 18819E00 Control Devices /13

Type 8074/2 V Max. operating speed Positive Rod lever 8074/2-.-DD-40 V 1.5 m/s Positive, not suitable for safety circuits 07700E00 8074/2-2: Positive distance 19006E00 2.5 N 20214E00 07702E00 8074/2-3: 8074/2-5: 75 19061E00 19007E00 75 07703E 19008E00 18817E00 /14 Control Devices

Type 8074/2 V Max. operating speed Positive Safety switch 8074/2-.-AZ-20 07695E00 8074/2-3: Positive distance 19010E00 17 N 07697E00 19011E00 Note: Depiction of the switching travel when the actuator is engaged. The actuators must be ordered separately. 18815E00 Control Devices /15

Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Actuator Straight actuator 8074/.-.-ZB 132311 0.028 18928E00 Bent actuator 8074/.-.-ZB 132312 0.037 18929E00 Movable actuator 8074/.-.-ZB 132313 0.035 18930E00 Roller plunger 8074/2-0-R 257520 0.102 18917E00 Roller lever 8074/2-0-WH 257531 0.102 18921E00 Parallel roller lever 8074/2-0-WPH 257532 0.102 18922E00 Rotary lever 8074/2-0-D 257533 0.102 18913E00 Long rotary lever 8074/2-0-DL 257534 0.102 18915E00 /16 Control Devices

Accessories and Spare Parts Designation Figure Description Art. no. Weight kg 1 NC + 1 NO Slow-action contact 8080/1-1 132529 0.025 Replacement contact elements 1 NC + 1 NO Snap-action contact with spring 8080/1-2 132531 0.025 10809E00 1 NC + 1 NO Slow-action contact, overlapping 8080/1-5 132534 0.025 2 NC Slow-action contact 8080/1-3 132532 0.025 Note Replacement contact elements for type -W, -R, -SR, -DL, -WH, -WPH, -D, -DS, -DD only Dimensional drawings (all dimensions in mm [inches]) Subject to modifications 19088E00 18928E00 Position switch 8074/2 Straight actuator for safety switch Control Devices /17

Dimensional drawings (all dimensions in mm [inches]) Subject to modifications Bent actuator for safety switch 18929E00 Movable actuator for safety switch 18930E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /18 Control Devices