BCH CITATION STARTERS

Similar documents
Single Phase Submersible Pump Starters

Range of Starters... for Every Need CITATION STARTERS

PRECISION & HEAVY DUTY LIMIT SWITCHES

Motor Protection Circuit Breaker

Motor Starters. Direct On Line Starters. Auto Start Direct on line Starters. Star Delta Starters. Mini Manual Starters. Mini Manual with UVT coil

The agreed minimum levels of the respective classes are based on efficiency measurements according to the old EN :1996.

ML 1.5 SS91851 ML 2 SS A 25 A 40 A 13.5 A 17 A 37 A 37 A. 6.3 A 15.5 A 15.5 A 12.5 A 23 A 23 A 19 A 830 V 415 V 500 V 3 kvar 120 A

Range : 7.5kW to 630/800kW

ThinkStarterThinkBCH

LST SWITCHGEA. Motor Starters. Type MN. . Direct-On-Line Starters. Star-Delta Starters LARSEN & TOUBRO LIMITED. Its all about Imagineering TM

LABOUR CHARGES - BODYPAINT JOBS. Applicable for Group I+ Cities New GenVerna (HCi)

Spectronic-SP Air Circuit Breaker

Capacity : 5 tons Engine Power : 79 bhp. High Performance & rugged Forklift Trucks.

HRC Fuse-links Bolted Type HG 2 A - 32 A HQ 2 A A

INTERNATIONAL FREIGHT

01 RX3 2014_Cover-Front.pdf 1 6/24/ :08:02 PM

DRX. MCCBs for residential and commercial SYSTEMS FOR ELECTRICAL INSTALLATIONS & INFORMATION NETWORKS.

Switch-Disconnector-Fuse HRC Fuse-links Bolted Type

ACX 750. Hydraulic Crawler Crane 75 tons Capacity. High performance rough terrain and rugged crawler crane.

INTERNATIONAL PASSENGERS

Energy Efficient 3 Phase LV Induction Motors

Price list 03/2018. w.e.f. April 1, 2018

A9K. MCB, RCCB, Isolator

Energy Efficient 3 Phase

Record SL. Moulded Case Circuit Breaker

Catalog. Low voltage General performance IE3 efficiency cast iron motors

EVERY DRILL DIESEL ENGINES FOR COMPRESSOR APPLICATIONS. - Pdf manuals & parts catalogs library

Flame Proof Motors For Hazardous Environment JHX

NATIONAL HOUSING BANK. Press Release

Price List. Power Factor. With effect from June 15, Correction Products. With effect from January 03, 2012

LET THE SUN POWER YOUR HOME

Modular Plate Switches

C O M M E R C I A L D E C O R A T I V E L I G H T I N G

Automatic Star Delta Starters IEC : 2012 Compliant Direct-on-Line Starters ISI Marked-BIS Approved

Energy Saving HRC Fuse-Links

Energy Saving HRC Fuse-Links

& Mini Mast Solution HIGHEST SP 1A SOLAR GRADING. Performance Monitoring with Bluetooth

Catalog. Classiq range Wiring accessories

LV- Power Quality Products and Systems

Manual changeover switches & Automatic transfer switches


Gas Recombination Vent Plug for Flooded Lead Acid Batteries

TM Ser i es. Tr uc k Mounted Cr anes. Rugged and reliable truck mounted cranes

Quality Products, Prompt Service, Trustful Relationships.

LV- Power Quality Products and Systems

VACUUM PUMP. Material of Construction: Applications:

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity

Young energy gives you more air delivery

Goldline Miniature Circuit Breakers

Complete protection made easy. Datasheet. hrc fuses BS TYPE

Domestic & Industrial Switchgear. Switchgear

Motor Starting Solutions Open Type Version, in Kit Form

The Young Energy Lasts Longer

Harmony Ø 22 Control and Signalling units

MANATECTM. World Class Garage Equipment MANATEC TOTAL SOLUTION

Switches that last longer.

Energy Efficient 3 Phase LV Induction Motors

JFB 15 / 20 / 25 / 30 Josts Electric Counterbalance Trucks (Capacity 1500 / 2000 / 2500 / 3000 Kg)

The most widely used motors from the world leaders

The GLC. Make the best of every ground.

More Power More Revenue More Insight

Enclosed motor starters

Smart. Shiny. Solar Powered. All-in-One. Solar Street Light

SPnorm & SPbloc Self Priming Centrifugal Pumps

Indoor Metal Clad Switchgear Type:Cubicle VHA 36 SF6 Circuit Breaker HPA 36 Rated Voltage: ABB Power Distribution

Spectra SP. Range of SD & SDF 32A to 800A

Sanitaryware. jaquar.com

SEMI ELECTRIC STACKERS ELECTRIC STACKERS COUNTER BALANCED STACKERS SIMPLIFYING MATERIAL HANDLING & WAREHOUSING

OPERATIONS CIRCULAR NO. 4 OF 2000

Auxiliary Relay. Type RXP8n, RXPQ8n

PUNCHED GRID RESISTORS

CI-TI Contactors and Motor Starters Type CI 6-50

Starters. Overview. Siemens caters with following types of starters to agricultural and industrial sector.

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

LT/HT Power & Control Cables

DC MOTORS. Crompton Greaves EVERYDAY SOLUTIONS

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

Non Return Valve Swing Check

Liebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity

LV- Power Quality Products and Equipments

CV Points Required. Economy Premium Economy Business

Kare Zindagi Instant Start

AF series contactors (9 2650)

Inspiring Designs. Inimitable Quality. Presenting Porselano 60 x 60 cm GVT Collection. A touch of refined class. 60X60 cm Glazed Vitrified Tiles

AF series contactors (9 2650)

Moulded Case Circuit Breakers New DU Series 20 A to 250 A

Consumer Luminaires PRICE LIST w.e.f. 1st April 2009

Smart choice for power distribution. Datasheet. sentron

A pump via filter and the heat exchanger (oil cooler) maintains the working oil circulation.

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

SERVICE INFORMATION POLICIES & PROCEDURES POST WARRANTY BODY REPAIR RATES REVISED ACCIDENT / INSURANCE CIRCULATE TO:

CI-TI Contactors and motor starters Types CI 61 - CI 98

Motor Protection Circuit Breakers

Technical Section: Miniature Circuit Breakers

B-SCHOOL TOP BUSINESS SCHOOLS IN INDIA (OVERALL) 208 BW BUSINESSWORLD 1-14 December 2015

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Infra Products. Infra Products

Dazzle. Designed to. Inspired by the beauty of India

Ashok Leyland Brake Equipment Parts Catalogue

Transcription:

BCH CITATION STARTERS

Starters A Range of Starters BCH manufactures a wide range of motor starters to suit every application in the field. The capacity starts from fractional horse power to 250 hp completely assembled ready to use units with built in overload and single phasing protection. Mini Manual Starter Direct-On-Line, manually operated, Mini Starter is designed for non-reversing control of all types of squirrel cage motors with an intermittent duty of 5 starts per hour (utilisation category AC3) complying with performance requirements of IS 8544 Part I. It is capable of switching motors upto HP, 45V, 3Phase or 3HP single phase. The starter unit comprises of a double break, on load switch operated by means of a toggle link mechanism. Adjustable bimetable thermal overload trips are included which can be set to follow closely the heating characteristics of the motor. Characteristics Utilisation category Insulation Voltage Thermal rating Operational current le Frequency of operation AC3 rating Mechanical life AC 3 as per IEC 292- and IS 8544 Part I 600V 20A 6A at 45V 5 operation per hour 6A at 45V, 50Hz 5 x Enclosure category Sheet steel enclosure to IP 5 as per IS 247 Therminal capacity One cable of 6 mm² or two cables of 4 mm² Selection Chart RECOMMENDED HP (KW) 3 PHASE 45V SINGLE PHASE 230V HP KW HP KW RELAY RANGE AMPS CATALOGUE** CODE 3 PHASE PHASE RECOMMENDED FUSE (AMPS) 0.23-0.47 AMLE AMLE -SP 2 0.46-0.8 AMLE 20 AMLE 20-SP 0.5 0.37 /6 0.095 0.85 -.55 AMLE 30 AMLE 30-SP 2 6 0.75 0.52.0 0.75 /6 0.3.60-3.20 AMLE 40 AMLE 40-SP.5. 3.0 2.20 0.5 0.37 3.50-6.50 AMLE 50 AMLE 50-SP 20 5.0 3.70 0.75 0.52.0 0.75 2.0.50 6.80 -.70 AMLE 60 AMLE 60-SP 25 7.5 3.0 2.20.00-2.00 AMLE 70 AMLE 70-SP 50 ** Substitute E by C for flush mounting.

Citation M Starters Contactor The contactors used in starters are NHD and Citation. They are built to IS 63947 and have many distinctive features such as : High grade moulding which reduces tracking and prolong operational life. Precision ground magnet frame and armature surfaces ensure consistent quiet operation. Exposed metals are treated for corrosion resistance. Low bounce and weld resistant contacts of silver cadmium oxide. Contactors can be inspected and maintained without disturbing adjacent wiring or altering contractor mounting positions. Coil is totally encapsulated in resin resisting moisture, corrosive atmosphere and damage while handling. Mechanical interlocking is provided between Star and Delta contractors in case of Starter ratings 40HP and above. Overload Relay Overload Protection : The relay fitted in the starter protects the motor from operational overload as per relevant standards established for the protection of motors. The range of current setting on any relay is between 0% to 60% of its minimum setting. Single Phasing Protection : The relay offers protection against single phasing through its sensitive differential mechanism in excess of the requirements of ISI specification 63947-4- and trips when it carries in healthy phases 0.9 times the minimum current setting, regardless of the value to which the current adjustment lever is set. Full protection is provided on single phasing under varying operational up to 50% of the full load rating of the motor. No protection is required below this value. Protection against unbalance voltage : The relay allows minor imbalance in voltage conditions in the three phases within the limits motors are designed to withstand. Beyond these limits, the relay trips and protects the motor. Excellent temperature compensation between -º C and +80º C (+55º C max. ambient). Facility for selection of either manual or automatic resetting of the trip switch. Snap-on cover to prevent inadvertent alteration to the setting of current adjustment or to the hand/auto lever. Test facility for tripping relay manually for checking of the circuit and wiring. Automatic Time Delay Relay The Time Delay Relay used in Automatic Star Delta Starter has superb repeat accuracy, gives satisfactory performance in frequent starting applications. It resets fast and the timing in not affected by variation in ambient temperature and voltage. Single Phase Motor Starter (with 2 Pole Contactor+2 Pole Relay) KW HP Overload Contactor Cat. No. 0.55 0.75 3.8-6.0 6A NAHBW-SP 0.75 6.0-9.3 6A NAJBW-SP..5 8.9-3.5 6A NAKBW-SP.5 2 3.2-20.0 25A NALBW-SP 2.2 3 7.4-24.0 25A NAMBW-SP 2

Starters Selection Chart - DOL MOTOR OUTPUT 45V 3 PHASE 50Hz KW HP OVERLOAD RELAY RANGE AMPERES CONTACTOR SIZE STARTER CATALOGUE CODE BACKUP PROTECTION HRC FUSE TYPE GII/GL (AMP ) 0.37 0.5 0.72 -.4 00 NADLEN 4 0.55 0.75.07 -.7 00 NAELEN 6 0.75.0.58-2.5 00 NAFLEN.50 2.0 2.4-3.8 00 NAGLEN 6 2.20 3.0 3.8-6.0 00 NAHLEN 20 3.70 5.0 6.0-9.3 00 NAJLEN 25 5.50 7.5 8.9-3.5 00 NAKLEN 35 7.50.0 3.2-20.0 00 NALLEN 50.0 2.5 7.4-24.0 CP20 NALLEN/MOR 50.0 5.0 7.4-24.0 0 NAMLEN 63.0 5.0 7.4-24.0 0 NAPLEN/MOR 63 5.0 20.0 23.0-32.0 0 NAPLEN 63 5.0 20.0 22.0-30.0 NANLEN 63 8.5 25.0 24.4-39.0 NACTLEN 80 22.0 30.0 37.6-60.0 D NACT2LEDM 0 30.0 40.0 37.6-60.0 E NACT2LEEM 25 DOL Reversing Starter in SS Enclosure ( with 380-45V Coil ) MOTOR OUTPUT 45V 3 PHASE 50Hz KW HP OVERLOAD RELAY RANGE AMPERES CONTACTOR SIZE STARTER CATALOGUE CODE BACKUP PROTECTION HRC FUSE TYPE GII/GL (AMP ) KW 0.75.00.58-2.5 00 NARFLEN.50 2.00 2.4-3.8 00 NARGLEN 6 2.20 3.00 3.8-6.0 00 NARHLEN 20 3.70 5.00 6.0-9.3 00 NARJLEN 25 5.50 7.50 8.9-3.5 00 NARKLEN 35 7.50.0 3.2-20.0 0 NARLLEN 50.0 5.0 7.4-24.0 NARMLEN 63 5.0 20.0 22.0-30.0 NARNLEN 63 Selection Chart - Star Delta MOTOR OUTPUT 45V ( 3 PHASE 50Hz. ) HP OVERLOAD RELAY RANGE AMPERES ( PHASE CONNECTED ) CONTACTOR SIZE AUTOMATIC STAR DELTA STARTER CATALOGUE CODE SEMI-AUTOMATIC STAR DELTA STARTER BACKUP PROTECTION HRC FUSE TYPE GII/GL (AMP ) 2.2 3.0 2.4-3.8 00 NASAGLEN NASSGLEN 3.7 5.0 3.8-6.0 00 NASAHLEN NASSHLEN 6 7.5.0 6.0-9.3 00 NASAJLEN NASSJLEN 20.0 5.0 8.9-3.5 00 NASAKLEN NASSKLEN 36.0 5.0 8.9-3.5 00 NASAKLEN/LOR NASSKLEN/LOR 36 5.0 20.0 3.2-20.0 0 NASALLEN NASSLLEN 36 8.5 25.0 7.4-24.0 0 NASAMLEN NASSMLEN 50 26.0 35.0 23.0-32.0 0 - NASSPLEN 50 26.0 35.0 23.0-32.0 0 NASA0PLEN NASS0PLEN 50 26.0 35.0 22.0-30.0 NASANLEN NASSNLEN 50 30.0 40.0 24.4-39.0 0 - NASS0CTLEN 63 30.0 40.0 24.4-39.0 NASACTLEN - 63 30.0 40.0 24.4-39.0 D NASACTLEDM - 63 37.0 50.0 37.6-60.0 D NASACT2LEDM - 80 55.0 75.0 37.6-60.0 E NASACT2LEEM - 0 65.0 85.0 56.4-90.0 E NASACT3LEEM - 25 75.0 0.0 56.4-90.0 M5 NASACT3LEC5M - 25 0 35 84.6-35.0 M5 NASACT4LEC5M - 200.0 50.0 84.6-35.0 N NASACT4LENM - 200 85 200 3.6-2.0 S NASACT5LEC6M - 250 280 375 88.0-300.0 S NASACT6LEC6M - 300 3

SEMI-AUTOMATIC STAR-DELTA STARTER WITH 4

Starters Tripping Characteristics Direct Operated CT Operated 4 THREE PHASE,000 TWO POLE,000,000 TRIPPING TIME IN SECONDS (ts) 3 2 TRIPPING TIME (SECONDS),000 0 MIN. NOM. MAX. TRIPPING TIME (SECONDS),000 0 MAX. NOM. MIN. TRIPPING TIME (SECONDS),000 0 MAX. NOMINAL MIN. 0.5 0.. MULTIPLE OF FULL LOAD CURRENT X I.5 MULTIPLE OF FULL LOAD/TRIP CURRENT.5 MULTIPLE OF FULL LOAD/TRIP CURRENT Mini Manual Starter Dimensions (mm) MINI MANUAL STARTER 8X5 2 SLOTS. 5.5 DIA. 4 MTG. HOLES 29 27 4 55 64 5 42 20 DIA. 4 HOLES FOR CONDUIT ENTRY 89 Flush Type 6 95 DIRECT-ON-LINE STARTER 5.5 DIA. 4MTG. HOLES 7.0 DIA. 4MTG. HOLES 39.0 DIA. 4 HOLES FOR CONDUIT 280.0 27.0 360.0 35.0 46.0 80.0.5 MULTIPLE OF FULL LOAD/TRIP CURRENT DOL & Star Delta Starter 96.0 30.0.0 60.0 4 HOLES DIA. 26.5 30.0 60.0 29.0 80.0.0 'A' 25 HP DOL 20 HP DOL DESCRIPTION 36 4 HOLES DIA. 33.0 FOR CONDUITS 62.0 20.0 DIMN. 'A' DOL STARTER 20 & 25 HP 7.0 DIA. 4 MTG. HOLES 25.0 280.0.0 62.0 DOL STARTER 30 HP. 36.0 FOR CONDUITS 5

DOL STARTER UPTO 40HP STAR DELTA STARTER STAR DELTA STARTER 40 HP (WITH NHD) 7.0 DIA. 4 MTG. HOLES SEMI AUTO & AUTO STAR DELTA STARTER UPTO 35HP 360.0 25.0 280.0 280.0 25.0 39.0 DIA. HOLE FOR CONDUIT 360.0 80.0 35.0 26.5 DIA. 3 HOLES FOR CONDUIT 36.0 62.0 7.0 DIA. 4 MTG. HOLES 26.5 DIA. 3 HOLES FOR CONDUIT 80.0 35.0.0 36 20.0 39.0 DIA. HOLES FOR CONDUIT AUTO STAR DELTA STARTER 90/70 HP (WITH SIZE-E) AND 0/50HP (WITH SIZE-M5).0.40.0 40 & 50 HP AUTO STAR DELTA STARTER (WITH SIZE-D) 400.0 706.0 750.0 600.0 556.0 4.0 DIA. 4 HOLES FOR MOUNTING 600.0 75.0 200.0 55.0 CABLE ENTRY 250X0 240.0 75X38X6 M.S.CHANNEL 2 NOS. 75.0 4.0 DIA. 4 HOLES FOR FLOOR MTG..0 22.5 5.0 3.5 DIA. 4 HOLES FOR WALL MOUNTING 82.0 CABLE ENTRY 200X70 72.0 22.0 45.0 365.0 3.5 DIA. 4 POLES FOR WALL MOUNTING 6

REVERSING DOL Visit us at : www.bchindia.com Corporate Office : 5, New Delhi House, 27, Barakhamba Road, New Delhi - 00 Tel. : 9--2336029/36/6539/436730 Fax : 9--2375247 CIN : U33WB965PLC026427, Customercare No. 800-3-9262, E-mail : marketing@bchindia.com Registered Office : Block E, 26, Acharya Jagadish Chandra Bose Road, Kolkata - 700 07 Works : 20/4, Mathura Road, Faridabad - 2 006 (Haryana) Tel. : 029-4063000/4293000 Fax : 029-230406 Works 2 : 64-68, Sector-7, IIE, Pant Nagar, Rudrapur, Udham Singh Nagar - 263 53 (Uttrakhand) Tel. : 05944-25024/6 Fax : 05944-25025 Sales Offices : Ahmedabad 93, City Centre, Near Swastik Char Rasta, C.G. Road, Navrangpura, Ahmedabad- 380 009 Tel. : 079-2656579/40074482 Fax : 079-2656579 E-mail : ahmedabad@bchindia.com Bangalore B.M.H. Complex, 2nd Floor, No. 22, Kengal Hanumanthiah Road, Bangalore - 560 027 Tel. : 080-22273478/444878/444879 Fax : 080-22236759 E-mail : bangalore@bchindia.com Chandigarh SCO 2-22-23, st Floor, Sector 34-A, Chandigarh - 60 022 Tel. : 072-5078957/266622 Fax : 072-5049905 E-mail : chandigarh@bchindia.com Chennai Flat No. 3A, 3rd Floor, Sree Apartments, No.508, TTK Road, Alwarpet, Chennai 600 08 Tel.: 044-24337046, 24337047 Fax : 044-24337047 E-mail : chennai@bchindia.com Coimbatore 87, Dr. Nanjappa Road, Coimbatore - 64 08 Tel. : 0422-23053 Fax : 0422-2302599 E-mail : coimbatore@bchindia.com Dehradun 8, Co-operative Industral Estate, Patel Nagar, Dehradun-24800 E-mail : dehradun@bchindia.com Faridabad 20/4, Mathura Road, Faridabad - 2 006 (Haryana) Telfax. : 029-230406 E-mail : faridabad@bchindia.com Hyderabad -8-303/48/3/2, Arya One, 2nd Floor, P. G. Road, Secunderabad - 500 003 Tel. : 040-66206263/27890306 Fax : 040-66207273 E-mail : hyderabad@bchindia.com Indore 330-33, Indraprastha Tower, 3rd Floor, 6, M.G. Road, Indore - 452 00 Tel. : 073-250 Fax : 073-2502 E-mail : indore@bchindia.com Jaipur 25, Hathroi, Gopalbari, Jaipur - 302 00 Tel. : 04-5452 Fax : 04-236352 E-mail : jaipur@bchindia.com Jamshedpur Kolkata 3rd Floor, Aastha Trade Centre, Block E, 26, 'Q' Road, Bistupur, Acharya Jagadish Chandra Bose Road, Jamshedpur - 83 00 Kolkata - 700 07 Tel. : 0657-23297/23248 Tel. : 033-2287728 E-mail : jamshedpur@bchindia.com E-mail : kolkata@bchindia.com Lucknow Madan Plaza, 3rd Floor, 4, Station Road, Lucknow - 226 00 Tel. : 0522-4025597/4025997 Fax : 0522-4025697 E-mail : lucknow@bchindia.com Ludhiana S.C.O.- 8, 2nd Floor, Feroze Gandhi Market, Ludhiana - 40 00 Tel. : 06-502807/5022808 Fax : 06-502807 E-mail : ludhiana@bchindia.com Mumbai A-5, Mittal Tower, Nariman Point, Mumbai - 400 02 Tel. : 022-22822947/2285062 Fax : 022-22822858 E-mail : mumbai@bchindia.com Nagpur Flat No. T/2, 3rd Floor Baldeo Apartment, Behind Railway Station, Bajeria Nagpur (M.S.) - 44008 E-mail : nagpur@bchindia.com New Delhi 80, Akash Deep Building, 26A, Barakhamba Road, New Delhi - 00 Tel. : 0-2333878/66307065 Fax : 0-23739230 E-mail : delhi@bchindia.com Pune 8, Sarosh Bhavan, 6-B/, Dr. Ambedkar Road, Pune - 4 00 Tel. : 020-26052590 Telefax : 020-2635224 E-mail : pune@bchindia.com Raipur 2nd Floor, Building No. B-234, Indira Gandhi Vyavasayik Parisar, Pandri, Raipur - 492 004 Tel. : 077-402023 Fax : 077-2582680 E-mail : raipur@bchindia.com Trichy Kingstone Park, 2nd Floor, 9/, Puthur High Road, Ramalinga Nagar, Trichy - 620 07 Tel. : 043-4040497 E-mail : trichy@bchindia.com Vadodara 30, Third Floor, Florence Classic,, Ashapuri Co-Op. Hsg. Soc. Ltd., Opp. VUDA Housing, Near Cow Circle, Akota, Vadodara - 390 020 Tel. : +9-265-6548444/2345068/2345069 Telefax : 0265-2345068, E-mail : vadodara@bchindia.com Other Branch Locations Bhubaneswar : bhubaneswar@bchindia.com, Cochin : cochin@bchindia.com, Gurgaon : gurgaon@bchindia.com, Guwahati : guwahati@bchindia.com,hospet : hospet@bchindia.com, Hubli : hubli@bchindia.com, Madurai : madurai@bchindia.com, Vishakapatnam : vizag@bchindia.com, Surat : surat@bchindia.com Resident Engineer Locations Baddi Bardhman Bhilai Bhubaneswar Cochin Dehradun Durgapur Gurgaon Haridwar Hubli Hospet Jodhpur Kakinada Kota Madurai Muzaffarnagar Nagpur Nashik Patna Puducherry Rajkot Rajahmundry Salem Surat Udaipur Vapi Vishakhapatnam Warangal Since product improvement is a continuous process, the data furnished in this brochure may undergo revision without prior notice.