Ball valve C 00 multipart, high k v value, high stability Advantage optimised kv value for all s, the internal ball diameter is constructively adapted to the internal pipe diameter exchangeable and ball high stability for the entire valve Application chemical plants industrial plants Utilisation for shutting off pipeline systems Flow Media Neutral and aggressive fluid or gaseous media free of solid particles, provided that the valve components coming into contact with the media are resistant at the operating temperature in accordance with the ASV resistance guide. Testing Requirements and tests/inspections according to DIN 344, 344, 8063 and 696. DIN EN 66, leakage rate A tested. Nominal Pressure (H O, 0 C) PN 0 PN 6 Fluid Temperature see pressure/temperature diagram Operating Pressure see pressure/temperature diagram Size DN 0 DN 50 Body PVCU PVCC Stem PVCU PVCC Ball PVCU PVCC Ball Seat Sealing Actuation with Thandle, simultaneously serving as a position indicator with electric actuator, DIN EN ISO 5 with pneumatic actuator, DIN EN ISO 5 union featuring a connection thread suitable for plastic materials GFR flange DIN 50, PN 0/6, facetoface dimension according to ASV standard /steel flange DIN 50, PN 0/6, facetoface dimension according to ASVNorm union socket end for solvent welding DIN ISO (PVCU) union socket end for solvent welding DIN ISO (PVCC) union socket end for fusion welding DIN ISO () union socket end for fusion welding DIN ISO () union spigot end for fusion welding DIN ISO () Mounting as required Fastening optionally available with bracket Accessories limit switch unit bracket union spigot end for fusion welding DIN/ISO (PE) Colour body: PVCU, grey, RAL 70 body: PVCC, grey, RAL 700 body:, grey, RAL 703 body:, opaque, yellowishwhite Thandle: PVCU, orange, RAL 004 GFR Flanges: black, RAL 90 /Steel Flanges: black, RAL 90 (08) 94 600 (08) 8374 7800 (03) 935 3900 (0) 4350 800 (07) 380 9500 /0
Ball valve C 00 Pressure/temperature diagram Pressure/temperature diagram P = operating pressure T = temperature The pressure/temperature limits are applicable for the stated nominal pressures and a computed operating life factor of 5 years. These are standard values for harmless media (DIN 403), to which the valve material is resistant. For other media please refer to the ASV resistance guide. The durability of wear parts depends on the operating conditions of the application. For temperatures below 0 C ( < +0 C) please specify the precise operating conditions of the application. The rated pressure depends on the valve and material. For the corresponding rated pressure value of the valve, please refer to the»order table«. Pressure loss curve (standard values for H O, 0 C) P = operating pressure T = temperature The pressure/temperature limits are applicable for the stated nominal pressures and a computed operating life factor of 5 years. These are standard values for harmless media (DIN 403), to which the valve material is resistant. For other media please refer to the ASV resistance guide. The durability of wear parts depends on the operating conditions of the application. For temperatures below 0 C ( < +0 C) please specify the precise operating conditions of the application. The rated pressure depends on the valve and material. For the corresponding rated pressure value of the valve, please refer to the»order table«. P = pressure loss Q = flow pressure loss and k v value The diagram shows the pressure loss P in relation to the flow Q. Conversion aid: c v = k v x 0.07; f v = k v x 0.0585 Units: k v [l/min]; c v [gal/min] US; f v [gal/min] GB (08) 94 600 (08) 8374 7800 (03) 935 3900 (0) 4350 800 (07) 380 9500 /0
Ball valve C 00 Flow characteristic VO = valve opening FR = K v value Torque (Nm) The specified torques apply to manually operated valves and are reference values. They were determined at the specified nominal pressures with H O, 0 C. These values can be higher or lower, depending on the operating pressure. Operating note Safe operation of the valve can only be ensured if it is properly installed, operated, serviced or repaired by qualified personnel according to its intended use while observing the accident prevention regulations, safety regulations, relevant standards, directives/technical regulations or codes of practice such as e.g. DIN, DIN EN, DIN ISO and DVS*. *DVS = German Welding Society The intended use includes adhering to specified limit values for pressure and temperature, as well as checking the resistance. This requires all components coming into contact with the medium to be "resistant" in accordance with the ASV resistance guide. (08) 94 600 (08) 8374 7800 (03) 935 3900 (0) 4350 800 (07) 380 9500 /0
Ball valve C 00, manual body PVCU ball PVCU 6 0 5 3 40 50 63 0 5 0 5 3 40 50 3/8 / 3/4 /4 / 6 6 6 6 6 6 6 PVCU 867 868 869 8630 863 863 8633 socket end DIN ISO 8655 0.6 kg 8656 0.6 kg 8657 0.8 kg 8658 0.40 kg 8659 0.4 kg 8660.00 kg 866.70 kg GFR 3 4 5 6 flange DIN EN 09 9 0.4 kg 0 0.60 kg 0.63 kg 0.79 kg 3.05 kg 4.5 kg body PVCC ball PVCC 6 0 5 3 40 50 63 0 5 0 5 3 40 50 3/8 / 3/4 /4 / 6 6 6 6 6 6 6 PVCC 4050 405 405 4053 4054 4055 4056 socket end DIN ISO 4058 4059 4060 406 406 4063 4064 0.6 kg 0. kg 0.35 kg 0.4 kg 0.57 kg.0 kg.84 kg (08) 94 600 (08) 8374 7800 (03) 935 3900 (0) 4350 800 (07) 380 9500 /0
Ball valve C 00, manual body ball 6 0 5 3 40 50 63 0 5 0 5 3 40 50 3/8 / 3/4 /4 / 0 0 0 0 0 0 0 8635 8636 8637 8638 8639 8640 864 socket end DIN ISO 8663 0.3 kg 8664 0.3 kg 8665 0.5 kg 8666 0.35 kg 8667 0.57 kg 8668 0.74 kg 8669 0.65 kg 75 76 77 78 79 80 spigot end DIN ISO 83 0.3 kg 84 0. kg 85 0.3 kg 86 0.60 kg 87 0.8 kg 88.8 kg GFR 7 8 9 30 3 3 flange DIN EN 09 35 0.30 kg 36 0.50 kg 37 0.73 kg 38.0 kg 39 0.94 kg 40.30 kg body ball 6 0 5 3 40 50 63 0 5 0 5 3 40 50 3/8 / 3/4 /4 / 6 6 6 6 6 6 6 socket end DIN ISO / steel flange DIN EN 09 867 0. kg 867 0.3 kg 5 0.76 kg 8673 0.3 kg 5.00 kg 8674 0.48 kg 53.50 kg 8675 0.90 kg 54.83 kg 8676.3 kg 55 3.00 kg 8677.06 kg 56 4.0 kg (08) 94 600 (08) 8374 7800 (03) 935 3900 (0) 4350 800 (07) 380 9500 /0
Ball valve C 00, manual dimensions DN(mm) 6 0 3/8 0 5 / 5 0 3/4 3 5 40 3 /4 50 40 / 63 50 dimensions(mm) /PVCU PVCU PVCC/PVCU PVCC/PVCU B B d dk D D D D E f H K L L L L3 L3 L3 L4 L4 L4 3.5 49 68 5 59 7 65 70 96 3 4 3.5 94 95 93 49 68 6 5 65 50 69 59 68 65 67 96 4 4.5 4 8 03 05 03 59 78 7 6 75 70 8 7 84 78 83 6 6 5 5 5.5 4 3.5 5 5 05 69 88 7 70 85 80 86 76 90 8 89 6 6 5 7 7.5 8 30.5 38 40 37 86 98 8 8 00 0 6 86 03 9 0 44 44 43 7 7.5 8 38.5 48 50 47 0 08 8 90 0 30 3 93 4 99 60 6 59 8 9 8 49 63 65 6 3 8 9 0 5 78 43 3 40 9 38 95 94 (08) 94 600 (08) 8374 7800 (03) 935 3900 (0) 4350 800 (07) 380 9500 /0
Ball valve C 00 parts lists position 3 4 5 6 7 8 9 3 4 quantity designation housing/body ball stem union threaded neck Thandle union end union nut Oring Oring Oring Oring Oring (08) 94 600 (08) 8374 7800 (03) 935 3900 (0) 4350 800 (07) 380 9500 /0