Instructions Manual Control Unit RCU205

Similar documents
UNIT CONTROL VK-30C. Instructions Manual

UNIT CONTROLVK-3i. Instructions Manual

CONTROL UNIT OMEGA 800-R. User manual

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

SK-10. Features. Solar Charge Controller User Manual. Important Safety Information

User Manual. Rev USER MANUAL MForks 1

User Manual. NiMH/NiCd Charger N, N, N, N Series

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES

IMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.

Model 7400 OPERATOR MANUAL

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

INTRODUCTION. Specifications. Operating voltage range:

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

BMS SV 24S for 2S-24S LiPo, LiFe & LiTO&others Low power consumption High accuracy 2.8 TFT LCD display Programmable

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

OCS-T High Resolution Digital Crane Scale

Solar Controller / Battery Charger User s Manual

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100

User Manual. Solar Charge Controller 3KW

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Flight Systems. Replacement for KASSEC DESCRIPTION

PWM-High Voltage Charge controller. User s Manual. Models available: 72V to 240V in 20A or 40A

User Manual Solar Charge Controller 3KW

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

FL-100-R (109) Operations and Installation Manual

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

ST Wiring diagram. Product description. Temperature controller. Order number

Harness the Power of the Sun

Instruction of Solar Charge Controller. User s Manual

Model 8000XL OPERATOR MANUAL

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL TCA200

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

Inlet Controller SB3500 USER'S MANUAL

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

Load Weighing Devices

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

User Manual. 3/1 10K/20K Online UPS with Isolation Transformer. Uninterruptible Power Supply System

Refrigerated incubator with Peltier technology

The measurements module provides the following engine features information:

User Manual 1KVA-5KVA INVERTER / CHARGER

Continental Hydraulics Installation Manual CEM-AA-A

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

ECONOMISER SERIES E2T USER MANUAL

W2175 LOAD INDICATOR Calibration (Version cal2175 V2.0)

BM16LP. Thanks for your purchasing the cell monitor for your vehicle.

Off Grid Solar Inverter. LVS 50M User Manual

AC drive has detected too high a Check loading

OWNERS MANUAL iforks. Rev OWNERS MANUAL iforks 1

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

TCwin AND THE STC THROTTLE CONTROLLER... 3 INSTALLATION... 3 SOFTWARE INSTALLATION... 3 DEFINITION OF TERMS... 4 MAP EDITING KEYS... 4 DIAGNOSTICS...

Installation & Calibration

FRUK+19 6K / FRUK+19 10K FRUK RM-01V / FRUK RM-01V

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL

Solar Hybrid Inverter SP Brilliant Series

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

MicroGuard 586 Retrofit Rated Capacity Indicator System. Calibration and Testing for:

User Manual. 6K/10K Online UPS. Uninterruptible Power Supply System

DIGITAL CRANE SCALE MODEL: OCS-S9 USER MANUAL

BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Draft Unofficial description of the UNRC charger menus

PV Charge Controller SBC-7108 / 7112 / 7120

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

Instruction of Solar Charge Controller. User s Manual

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Installation & Operation Manual

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

ICON 2 1. FEATURES AND CHARACTEIRICS

Features: Enhanced throttle response, excellent acceleration, linearity and driveability

Combo 64. When Safety Matters. - Beacon Conrol - Spare Output - D.R.L Control - Park Brake Alarm. Digital Switching Systems Australia

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

Kelly KDC Series/PM Motor Controller User s Manual

Eclipse Solar Suitcase

BMS24. Thanks for your purchasing the BMS24 for your vehicle.

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Plug in to external instrument, lamp or buzzer

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

EGT-100 Operations and Installation Manual

REMOTE POWERING Central Energy System ( HUB )

PV Charge Controller SBC-6108 / 6112 / 6120 / 6130

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

Technical Data Sheets

BMS16T BMS24T. Thanks for your purchasing the BMS16T or BMS24T for your vehicle.

FP-100 Fuel Pressure and Ammeter Indicator Page 1 of 16. All specification subject to change Aerospace Logic Inc.

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

D-67 Charger La Palma Ave., Suite 103, Yorba Linda, CA Ph: (714) Fax: (714)

Model DS7060 Handrail Scale. User Manual

3P Rainforce 350H. Installation & Operating Manual

Gobius 4 for Waste Holding Tanks, new version 5.0

Solar Controller SUNGO S

I. SIM card preparation 3 II. Installation into a vehicle 3. III. Most common issues and their solutions 9 III. Attachments 10

GRAVITY MEASUREMENT, INC.

Transcription:

Instructions Manual Control Unit RCU205 1 / 8

Instructions Manual 2 / 8

1. Introduction RCU 205 RCU device main field application is the load limitation in elevators. The measurement accuracy is higher than the usually required. This device measures the weight supported by the load cell and activates the relays when the programmed levels are overflowed.the relay contacts may inform to the elevator control board about the programmed levels status. 2. Installation and connections 24..230 V (DC or AC) 3 / 8

3. Control, inputs and outputs. Instructions Manual HOLD: Hold is a universal input with a voltage range from 24 to 230V AC or DC. This input is used to communicate the RCU that the elevator is in motion state and it works as follows: o Hold function activates when the doors are closed, and blocks the weighing process to avoid the relays change the status o while the elevator is moving. When it is activated it retains the real value inside the cabin and for any weight variation when the elevator moves from one floor to another will be considered as added weight to make chain compensations. The use of this input is optional, but necessary if chain compensation is required. Remarks: When the hold signal is activated the device shows HOLD blinking in the display. RELAYS: Two relays with an opened free voltage contact which status change when the load level is higher than the programmed level. BZ: External buzzer. The device allows to connect a 5V buzzer between the negative pole power supply and the 9th pin SENSORS: USB Connection for the load cell. 4. Access to menu parameters. Menu key. Pressing this key, the device will enter into the parameters program mode, and show the first parameter AL1. Afterwards pressing this key successively all the programmable parameters are shown in cycle way. To go back to the weight presentation, press the key several times until the end of the menus. Press this key to enter on the chosen parameter to modify the value. This key is to change the digit value when we are setting the parameters. 4 / 8

RCU 205 5. Parameters modification. Alarms Modification. 1. Press successively the key until select the desired alarm. 2. Press the key to enter in parameter modification. The left digit will blink. 3. Select the wished value in the display using the keys and. 4. Press twice to set the chosen load level value. If it is pressed only once, after 10 seconds the process finishes without saving the change. 5. Change the idle status of the relay with the key.(on = Close, OFF = Open) 6. Press twice to save the changes. If it is pressed once, after 10 seconds the process finishes without saving the change. Remarks: When the device has no power supply, the relay status is OFF = Open. The overload has to be connected in the alarm/relay 2 Parameters Modification (no alarm) 7. Press successively the key until select the desired parameter. 8. Press the key to enter in parameter modification. The left digit will blink. 9. Select the wished value in the display using the keys and. 10. Press twice to save the change. If it is pressed once, after 10 seconds the process finishes without saving the changes, and the display shows again the parameter. 6. Menu structure Pressing successively the key the menu parameters are shown in the following order: Device in weighing mode. Alarm level 1 and relay rest status 1(On/OFF) Alarm level 2 and relay rest status 2(On/OFF) Zero Setting Adjustment of sensibility with a well known weight Adjustment of sensibility with the nominal load of the cell Maximum value of chain compensation weight Alarm Sound (On/OFF; Intermittent sound with the alarm 2). 5 / 8

7. Unit control adjustment. Instructions Manual This section is required for the unit to know the relation between the signal from the cell and the known-weight set in the cabin. It is recommended to make the adjustments at the lowest floor. The adjustment is made in 2 steps as follows: 1. Zero Setting. 2. Sensibility Adjustment (for this adjustment there are 2 methods). a. Sensibility Adjustment with a well known weight. b. Adjustment with direct transmission load cells. Zero Setting: 1. Select menu option. 2. Check that the cabin is empty and press key, and the display will blink. 3. Press while the display is blinking to confirm the operation which starts with a 10 seconds countdown. The display will show parameter at the end. Remark: If is not pressed before the blinking finishes, the operation will be not saved. a. Adjustment of weight (valid for all kind of load cells). 1. Introduce inside the cabin a well known weight (it is recommended a minimum weight of 50% of the maximum load applied inside the cabin). 2. Select menu option, and press to enter into modification state. 3. Set the value of the well known weight with the keys. 4. Press the key twice (The unit will start a 10 seconds countdown and the value will be saved).the display will show parameter at the end. Remark: If is not pressed before the blinking finishes, the operation will be not saved. b. Adjustment with direct transmission load cells. 1. With this method it is not required to put a well known weight in the cabin. 2. Select the menu option and press to edit the value. 3. Input the value of the nominal load of the cell with the keys. In case of having several load cells the input value should be the sum total of them. 4. To save the value press twice (the value remains saved). Remark: If is not pressed before the blinking finishes the operation will not be saved. 6 / 8

8. Compensation chain RCU 205 The chain compensation is a software algorithm that verifies the weight difference between flats and compensates it. The HOLD signal must be activated when the doors are closed, to compensate the weight during the elevator movement. should have the estimated weight of the chain. Chain compensation is not applied if value is set to zero.the default value of is zero. The maximum CAdE compensation value of the unit is 0050 (this is the maximum weight value to compensate the chain weight). 9. Specifications Nominal voltage: 24 Vdc Maximum current: 80mA Short circuitable power supply, internal fuse is not needed. Relay contact current: 3A/250Vac. Box: VO fireproof plastic IP-60 10. Error codes and ttroubleshooting Error description Load cell wrong connected, broken down or cable is cut. Negative overflow of the converter, so the load cell is giving a negative signal too high. Positive overflow. Load cell is supporting a higher weight than the nominal load. Polarity error. It is detected when the control unit is adjusted with a well known weight and the polarity is changed, or the weight is not in the cabin during the adjustment. Data loss in memory. Load cell with very low sensibility. Usually the unit is wrong adjusted. Action Check the load cell connection. Check the load cell connection because it should be no negative charge. It is necessary to use a load cell with higher nominal load. Check the load cell connection. Adjust again on zero and weight. Reprogram the unit. Adjust again on zero and weight. Remark: When an error is produced all the alarms are activated and the elevator remains blocked. If is produced the relay contacts will open (RELE = OFF). 7 / 8

116-5047-02 14/03/2013 11. Quick programming guide. Installation Manual 1) Install the sensor and connect it to the unit control. To connect properly the sensor to the unit control, please see section Nº.1 (Installation) 2)Before to start to calibrate the unit control, please be advise to do the following: a). Down the cabin to the lowest floor of the building. (or in the half way of the itinerary) b). Bounce inside the cabin to avoid possible hooks on the guide rail. 3) Most important parameters to calibrate step by step: 1. Adjust the with the cabin empty. 2. Place a well known weight in the cabin (minimum 50%). 3. Adjust the. Input the value of the well known weight. 4. Adjust alarm with the load value that activates the relay 1, and the relay state. (Remarks: On this parameter you could assign the full load alarm) 5. Adjust alarm with the load value that activates the relay 2, and the relay state. (Remarks: On this parameter you could assign the over load alarm) 6. Input in the estimated weight of the chain. 7. Choose the status (On = Overflow sound activated) Remark: It is important to adjust zero before the weight adjustment. Dinacell Eletrónica s.l. Pol. Ind. Santa Ana. C/ Torno 8. 28522 Rivas Vaciamadrid Madrid (Spain) 8 / 8