K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC

Similar documents
D1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information...

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

J1-2. Table of Contents RETURN GRILLES

ROUND DIFFUSERS G1. RM, RA Series Cone Diffusers. Introduction: RM, RA Series ROUND DIFFUSERS R M - R A S E R I E S

J1-2. Table of Contents RETURN GRILLES

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

4880 This heavy duty, double deflection, supply grille features 1/2 front and 3/4 back blade. spacing. Available in steel construction only.

LINEAR DIFFUSERS AND BAR GRILLES

L1-2. Table of Contents SECURITY GRILLES 1310, 1310TF, Introduction & Dimensional Information... L1-13

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

CRNRR, 5CRNRR These concentric ring nozzles feature a stub duct mounting frame for smaller duct work

M1-2. Table of Contents INDUSTRIAL GRILLES. 680, 5680, 6880, 56880, 680MP, 5680MP Introduction... M1-3 Dimensional Data... M1-4

LINEAR DIFFUSERS AND BAR GRILLES

EXTRUDED ALUMINUM LINEAR BAR GRILLES AND REGISTERS

A1-2. Table of Contents ARCHITECTURAL & PLAQUE DIFFUSERS

SUPPLY ROUND DIFFUSERS TABLE OF CONTENTS ROUND DIFFUSERS. M-2 Excellence in Air Distribution MODELS RM1/5RM1/RM2/5RM2/RM4/5RM4/RA2/RA4

for Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Bar & Floor Grilles Product Bulletin 135-D

Extruded Aluminum Construction 1/4 Bars on 1/2 Centers Floor, Sidewall or Ceiling Mount Pencil Proof

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

LAMINAR FLOW DIFFUSER Model DLAB

MODULAR CORE CEILING DIFFUSERS

D3-2. Table of Contents DISPLACEMENT VENTILATION

Square/Rect. and Square Louvered Face and Plaque Face Diffuser

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER

Application Guidelines

Application Guidelines

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

Series DD & SD-20 Supply Grilles & Registers

INDEX. Chapter3. air master. Linear Bar Grilles

FlowBar High Capacity Slot Diffuser

EGG CRATE RETURN GRILLE

LINEAR SLOT DIFFUSERS PLENUMS

GRILLES AND REGISTERS

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

GRILLES AND REGISTERS

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

CEILING DIFFUSERS D12 CEILING DIFFUSERS

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

CEILING DIFFUSERS CEILING DIFFUSERS

Wall and Ceiling Grille

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

Price O.R. Systems AIR CURTAIN SYSTEM

LOUVERED FACE GRILLES AND REGISTERS

F1-2. Table of Contents PLENUM SLOT DIFFUSERS PTBS. Introduction & Dimensional Information... F1-3. Accessories... F1-54. Reference Charts...

LINEAR DIFFUSERS AND BAR GRILLES

GRILLES AND REGISTERS

GRILLES AND REGISTERS

Catalogue. FlowBar. High Capacity Slot Diffuser.

GRILLES AND REGISTERS

GRILLES AND REGISTERS

CEILING DIFFUSERS CEILING DIFFUSERS

GRD PRODUCT CATALOG DISPLACEMENT VENTILATION PRODUCTS

GRILLES AND REGISTERS

STEEL LOUVERED DIFFUSERS [CFM Range is only a guide. See Manufacturer Catalog for complete data. All NC Levels in Acceptable Range<32.

fsfdfsdfsdfssfsf OMNI DIFFUSER

GRILLES AND REGISTERS

PERFORATED CEILING DIFFUSERS

PERFORATED CEILING DIFFUSERS

GRILLES AND REGISTERS

Linear Slot Diffusers Model Slot 20 & Model Slot 25

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

RPD ROUND PLAQUE DIFFUSER

CEILING DIFFUSERS CEILING DIFFUSERS

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Premium Correctional Air Distribution. The First Name in Air Diffusion.

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

PATTERN CEILING DIFFUSERS

GRILLES AND REGISTERS

GRILLES AND REGISTERS

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

SERIES PG. Perforated Face

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

SPD/SPDV SPD SPDV. High Velocity/High Aspiration Air Outlet. Construction

CEILING DIFFUSERS CEILING DIFFUSERS

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Steel Single Deflection Supply Grille, Register (RSSB, RTSB)

DCG Adjustable Aluminum Round Diffusers

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

HIGH CAPACITY LINEAR SLOT DUFFUSERS

GRILLES AND REGISTERS

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

LINEAR SLOT DUFFUSERS

INDEX. Chapter2. air master. Grilles and Registers

product description model AL UP TO 120" SINGLE PIECE CONSTRUCTION REDUCES JOINTS Airline Linear Grilles & Registers Aluminum Bar Grilles & Registers

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

makes sure products are delivered Products are offered in steel,

D2-2. Table of Contents RETROFIT/BYPASS TERMINAL UNITS

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Airline Linear Grilles

OVERVIEW Combination Supply/Return Diffuser (SARM)

Transcription:

K Table of Contents, This series of extruded aluminum supply and return linear bar grilles are for ceiling, sidewall, sill (), and floor () applications. Blade thickness is 7/32., This series of extruded aluminum supply and return linear bar grilles are for ceiling, sidewall, sill (), and floor () applications. Blade thickness is /. 7 This extruded aluminum supply and return linear louvered grille is for ceiling or sidewall applications and features a way or 2way deflection with removable core., MC,, MC Introduction... K3 Dimensional Information & Frame Styles... K4 Mitered Corner Dimensional Information... K Access Door & Oversized Units... K9 Accessories... K Reference Charts... K Performance Data... K3 Engineering Specifications... K2, MC,, MC Introduction... K23 Dimensional Information & Frame Styles... K24 Mitered Corner Dimensional Information... K2 Access Door & Oversized Units... K29 Accessories... K3 Reference Charts... K3 Performance Data... K33 Engineering Specifications... K4 7, 7MC Introduction... K43 Dimensional Information... K44 Mitered Corner Dimensional Information & Accessories... K4 Reference Charts... K4 Performance Data... K47 Engineering Specifications... K49 K2 www.kruegerhvac.com Excellence in Air Distribution KRUEGER 22

K, / Blade Thickness Introduction:, The and architectural linear bar grilles are designed to provide a clean, strong, horizontal look while offering optimum performance. The availability of a variety of frames and finishes allow the grilles to blend, compliment, or contrast with the ceiling, sidewall, sill, or floor installations. These grilles can be used on supply or return portions of heating, cooling or ventilation systems. The / series linear bar grille is an excellent choice for installation in soffit/sill applications where airflow is required to wash over a window. MODELS Supply or Return Linear Bar Grille for Ceiling, Sidewall, or Sill Applications Supply or Return Linear Bar Grille with Layin, Removable Core for Floor Applications Model FEATURES Available with blade deflection, /4 bar spacing, and / blade thickness. Available with blade deflection, /2 bar spacing, and / blade thickness. Available with blade deflection, /4 bar spacing, and / blade thickness. Available with blade deflection, /2 bar spacing, and / blade thickness. Extruded aluminum construction. Section lengths range from to 72 long; units longer than 72 will consist of sections butted together. Widths range from 2 to 24 (Model Series) and 2 to 2 (Model Series). ACCESSORIES Mitered Corners (Models MC & MC) Blankoff Strips (Model BOS) Linear Straightening Grid (Model LSG) Access Door (Model Series) Damper OPTION Curving FINISHES Standard finish is #44 British White. (Model Series) Standard finish is #44 British White or # Alumican. (Model Series) Optional finishes available. Optional anodizing available. Corresponding mitered corner for Model. WO construction shown. Model KRUEGER 22 Corresponding mitered corner for Model. CO construction shown. Providing You With Air Distribution Solutions K23

K, / Blade Thickness Dimensional Information & Frame Styles, FACE VIEW FOR FRAME STYLES A, B, C, AE, BE, CE, DS, & RG 7/" (22) 9" (229) MAX NOTES: Dimensions in parentheses are mm. For grille length and width dimensional information, see table on page K2., FRAME STYLES A, B, C, AE, BE, CE, DS, & RG / / / /32 / /32 3/32 / 3/32 27/32 / 27/32 + 3/4 + /4 + 3/4 FRAME A FRAME B FRAME C / / / / / / /32 / /32 3/32 / 3/32 27/32 / 27/32 + 3/4 + /4 + 3/4 FRAME AE FRAME BE FRAME CE / / 3/4 /4 9/32 / 9/32 /32 / /32 + /4 /4 FRAME DS FRAME RG NOTE: Dimensions in parentheses are mm. K24 www.kruegerhvac.com Excellence in Air Distribution KRUEGER 22

K, / Blade Thickness Dimensional Information & Frame Styles, FACE VIEW FOR FRAME STYLE D, FRAME STYLE D 9" (229) MAX 7/" (22) LENGTH EQUALS NOMINAL DUCT PLUS /4" () EQUALS NOMINAL DUCT PLUS /4" () 9/32 / / + /4, FACE VIEW FOR FRAME STYLE R, FRAME STYLE R 9/32 /" () FACE 9" (229) MAX 7/" (22) / EQUALS NOMINAL DUCT MINUS /4" () TYPICAL DUCT BY OTHERS LENGTH EQUALS NOMINAL DUCT MINUS /4" () /32 / /4 /32 NOTE: Dimensions in parentheses are mm., Dimensional Information,, LENGTH & DIMENSIONAL DETAIL KRUEGER 22 O D F C CORE FRAMES A, B, C, D, R, H, M, & N D O F C CORE FRAMES DS & RG O D F C CORE FRAMES AE, BE, & CE Frame Frame Length Overall Dimension Core Opening Length F O C A D /" D + 3/4" D 3/4" B D /" D + /4" D 3/4" C D /" D + 3/4" D 3/4" D D /" D + /4" D 3/4" R D /" D /4" D 3/4" AE D D + 3/4 D 3/" BE D D + /4" D 3/" CE D D + 3/4" D 3/" DS D D + 7/" D 3/4" RG D D D 3/4" H D D + 2 /4" D 3/" M D D + /" D 3/" N D D D 3/" NOTES: Lengths based on end caps mounted on each end. D = Nominal duct dimension length/width (or ordered length) F = Actual overall neck dimension length/width O = Overall face dimension length/width C = Actual core opening length/width Providing You With Air Distribution Solutions K2

K, / Blade Thickness Mounting Options, MOUNTING OPTIONS FOR FRAME STYLES A, B, C, & D DUCT BY OTHERS DUCT BY OTHERS NO MOUNTING DUCT BY OTHERS SPRING CLIP MOUNTING SCREW HOLE MOUNTING* DUCT BY OTHERS CONCEALED MOUNTING NOTES: All fastening methods for Frame R are provided by others. * Frame D not available with screw hole mounting., MOUNTING OPTIONS FOR FRAME STYLES AE, BE, CE, DS, & RG DUCT BY OTHERS DUCT BY OTHERS NO MOUNTING SPRING CLIP MOUNTING + / DUCT BY OTHERS CONCEALED MOUNTING Deflection Patterns, NORMAL AIR DEFLECTION PATTERN (N), EVERY OTHER AIR DEFLECTION PATTERN (E) / (3) K2 /4 () OC / () TYP / () TYP / (3) /4 () OC NOTE: Dimensions in parentheses are mm. /" (3) /2" (3) OC www.kruegerhvac.com Excellence in Air Distribution /" () TYP /" () TYP /" (3) /2" (3) OC KRUEGER 22

K, / Blade Thickness Dimensional Information & Frame Styles, FACE VIEW FOR FRAME STYLES H, M, & N " (2) MAX NOTES: Dimensions in parentheses are mm. For grille length and width dimensional information, see table on page K2., FRAME STYLES H, M, & N 2 / /4 3/ /4 + / 3/ 3/ 3/ 3/ / / / FRAME H * FRAME M * FRAME N * NOTES: Dimensions in parentheses are mm. Nominal duct equals ordered size. For actual dimensions, see table on page K2. * Suggested floor opening for Frame H, M, and N is nominal duct size plus / (.). Mounting Options, MOUNTING OPTIONS FOR FRAME STYLES H, M, & N FINISHED FLOOR OR SILL NOTES: Dimensions in parentheses are mm. ** Not available for Frame N. ANGLE BY OTHERS NO MOUNTING DUCT BY OTHERS + /4 SPRING CLIP MOUNTING** DUCT BY OTHERS SCREW HOLE MOUNTING** DUCT BY OTHERS KRUEGER 22 Deflection Patterns, NORMAL AIR DEFLECTION PATTERNS (N), EVERY OTHER DEFLECTION PATTERNS (E) /" () TYP /" () TYP /" () TYP /" () TYP /" () TYP /" (3) /" (3) /" (3) /" (3) /" (3) /4" () OC /4" () OC /2" (3) /4" () OC /2" (3) OC OC NOTE: Dimensions in parentheses are mm. Providing You With Air Distribution Solutions K27

K, / Blade Thickness Mitered Corner (MC, MC) Deflection Patterns MC, MC, 9 DEFLECTION PATTERN MC, MC, 3 DEFLECTION PATTERN L OUTWARD DEFLECTION (CO) DUCT OA MC, 9 DEFLECTION PATTERN L DUCT OA INWARD DEFLECTION (CI) OA OA OUTWARD DEFLECTION (CO) OA OA INWARD DEFLECTION (CI) OA OA OA OA OUTWARD DEFLECTION (WO) INWARD DEFLECTION (WI) 3º ALSO AVAILABLE Mitered Corner (MC, MC) Dimensional Data MC, OVERALL DIMENSIONS FOR FRAME STYLES Duct Duct Frames Width L A B C D R AE BE CE DS RG 2" 4" ( 2) 2" (3) 2 7/" (327) 2 /" (32) 2 3/" (34) 2 /" (3) 7/" (32) 3 3/" (33) 2 /" (329) 2 /" (32) 2 3/" (3) 2" (3) 4 /2" 2" (4 3) " (47) 7/" (479) /" (473) 3/" (47) /" (4) 7 7/" (44) 9 3/" (47) /" (4) /" (473) 3/" (42) " (47) MC, OVERALL DIMENSIONS FOR FRAME STYLES Duct Duct Frames Width L H M N 2" 4" ( 2) 2" (3) 2 7/" (327) 2 3/" (32) 2" (3) 3" 4" (7 2) 2" (3) 4 /2" 2" (4 3) MC, MAXIMUM FLOOR LOADING K2 " (47) 7/" (479) 3/" (47) " (47) Maximum Vertical Distributed Load Maximum Vertical Live Load www.kruegerhvac.com Excellence in Air Distribution Maximum Horizontal Load Model Blade Spacing lbs/in 2 lbs/ft 2 lbs Normal /" (3) /4" () 3 3 Every Other /" (3) /2" (3) 2 2 NOTES: Dimensions in parentheses are mm. Dash indicates not available. KRUEGER 22

K, / Blade Thickness, Access Doors & Oversized Units, ACCESS DOOR OPTION LH LH LH FACE VIEW HINGE OUTSIDE " (2) TYP 72" (29) MAXIMUM DUCT TYP HINGE INSIDE RH " (2) TYP RH RH NOTES: Dimensions in parentheses are mm. Linear bar access doors provide open area approximately (27) long by a width determined by the specified unit width. Access doors are not available with the models.,, OVERSIZED UNIT DIMENSIONAL DETAIL DUCT BY OTHERS OVERALL FACE LENGTH DUCT LENGTH ALIGNMENT PIN OVERSIZED UNIT ASSEMBLED FACE VIEW 72" (29) MAX 72" (29) MAX DUCT LENGTH 72" (29) MAX ALIGNMENT TAB LEFT END BUTT CUT BOTH ENDS BUTT CUT BOTH ENDS BUTT CUT RIGHT END BUTT CUT OVERSIZED UNIT SECTIONS NOTES: Dimensions in parentheses are mm. Oversized units are assembled with the minimum number of sections based on a maximum individual duct length of 72. Alignment tabs and pins are provided to facilitate assembly. Alignment tabs and pins are not available with Frames M and N. KRUEGER 22 Providing You With Air Distribution Solutions K29

K, / Blade Thickness, Accessories LINEAR OPPOSED BLADE DAMPER (LOBD) LINEAR STRAIGHTENING GRID (LSG) 3" (7) MINIMUM DUCT 3" (7) MINIMUM DUCT S 3" OR GREATER NOTES: Dimensions in parentheses are mm. Do not use with Frames DS and RG. Do not use with concealed mounting. 3 /" (7) S 3" OR GREATER NOTES: Dimensions in parentheses are mm. Do not use with Frames M, N, or R. Do not use with spring clip mounting. 2 7/" (2) SINGLE BLADE DAMPER (SBD) SINGLE BLADE DAMPER (SBD) 2" () DUCT DAMPER ADJUSTMENT 2 /2" (4) TO 4" (2) DUCT 2" ONLY S 2 /2" TO 4" NOTES: Dimensions in parentheses are mm. Do not use with Frames H, M, N, DS, or RG. Do not use with concealed mounting. Do not use with widths greater than 2 (). NOTES: Dimensions in parentheses are mm. Do not use with Frames H, M, N, DS, or RG. Do not use with concealed mounting. BLANKOFF STRIP (BOS) 2" () MINIMUM DUCT /" (27) NOTES: Dimensions in parentheses are mm. Do not use with spring clip mounting. K3 www.kruegerhvac.com Excellence in Air Distribution KRUEGER 22

K, / Blade Thickness, Reference Charts AIRFLOW VS. NC LEVEL:,, DEFLECTION, / BARS, /4 BAR SPACING, 4 LENGTH 3 2 Airflow (CFM) 2 24 22 2 4 Neck Size 4"x2" 4"x" 4"x" 4"x" 4"x" 2 4"x4" 4 4"x3." 4"x3" 4"x2." 4"x2" 2 2 2 3 3 4 Sound Level, NC AIRFLOW VS. NC LEVEL:,, DEFLECTION, / BARS, /2 BAR SPACING, 4 LENGTH 4 3 3 34 Airflow (CFM) 32 3 2 2 24 22 2 4 2 Neck Size 4"x2" 4"x" 4"x" 4"x" 4"x" 4"x4" 4"x3." 4"x3" 4"x2." 4"x2" 4 KRUEGER 22 2 2 2 3 3 4 Sound Level, NC Providing You With Air Distribution Solutions K3

K, / Blade Thickness, Reference Charts AIRFLOW VS. NC LEVEL:,, DEFLECTION, / BARS, /4 BAR SPACING, 4 LENGTH 2 23 Airflow (CFM) 2 9 7 3 Neck Size 4"x2" 4"x" 4"x" 4"x" 4"x" 9 4"x4" 4"x3." 7 4"x3" 4"x2." 3 4"x2" 2 2 3 3 4 Sound Level, NC AIRFLOW VS. NC LEVEL:,, DEFLECTION, / BARS, /2 BAR SPACING, 4 LENGTH 32 3 2 Airflow (CFM) 2 24 22 2 4 2 4 Neck Size 4"x2" 4"x" 4"x" 4"x" 4"x" 4"x4" 4"x3." 4"x3" 4"x2." 4"x2" 2 2 2 3 3 4 Sound Level, NC KRUEGER 22 K32 www.kruegerhvac.com Excellence in Air Distribution

K, / Blade Thickness, Performance Data KRUEGER 22 IP/METRIC DATA:,, DEFLECTION, / BARS, /4 BAR SPACING (NO OBD) IP Data Metric Data Nom. Air Press Perpendicular Nom. Air Press Perpendicular Duct Flow Pv Throw NC Duct Flow Pv Throw Octave Band, db in. CFM/ft "WG ft mm L/s/m Pa m 2 3 4 7 2.2 3 3. 3..9.3.3 2 2 4.49 7.2 2.3 2.23.3. 32 33 2. 22 2 9.3 27. 3.34.. 39 4 33 2 2 2".97 42 29 2.4 49. 4.4.7. 43 4 4 32 2 22.3 7229 3. 7.7..2.7 47 4 4 34 29 2.444 2232 4....9. 3 3 4 4 3 4.4 22434 4 2.7.4.7.3.4 3 7 47 4 4.2 9.2.3.92.. 27 2 2.7 9422 9.3 4. 2.4.2. 34 3 24. 22 2 2.4 2. 3.7.7. 39 4 33 2 4 2 /2".7 229 27 4. 39.2 4.7.2.7 43 4 39 29 23 9 2.22 2232 33..4..9. 4 4 44 3 3 2 4.3 22434 37 2.7 7.7.7.3.4 4 49 43 3 3.43 223 4 24..2.47.. 4 3 4 4 3.34 222 9.3. 2.3.7. 3 32. 2 2.4.2 3.3.7. 3 37 2.9 4229 2. 23.7 4..2.7 4 4 33 2 4 3" 2.37 2232 27 7. 34...9. 43 4 3 27 2 4. 92434 3 2.7 4.4.7.3.4 4 4 43 34 27 23.244 223 3 24...47.. 47 47 39 32 2.3 222739 3 27.9 7.7..3.7 49 2 44 37 32 7.3 942..9 2.4.27. 32 33 9.4 229..9 3.7..7 37 3 2 3 2.99 2332 23 9.4 24. 4.7.99. 4 43 34 22 3 3 /2".43 23 2 9 23.3 3.7.7..7 44 4 4 29 23 9 7.9 22273 33 27.2 4...2. 4 49 44 3 29 2 2.2 23294 3 3. 3.4 7..72.4 49 4 4 34 29 22.322 2343 4 34.9.3 7.9.33. 3 4 3 33 7.22 224.9. 2.43.7.2 29 29 3.4 729..4 3.4.2.7 3 3 24 3.77 2233 2 2.2 9.2 4..7. 39 4 3 2 4".7 23 2 2 24. 29..7.. 43 4 37 2 2 9. 2224 3 29. 4...2. 4 4 42 33 2 22 22.22 2343 3 34.2 4.9 7.9.23. 4 47 3 32 27 2.2 2324 39 3. 7.9.9.3. 3 43 37 32 3.4 3933 2.2.2 3.9.9. 3 37 2. 243 24. 7. 4.7.3. 39 4 3 9.9 924 24 29. 24..7.2. 42 44 3 23 7 4 " 22.29 22343 29 27 34.2 32..9.23. 4 47 4 29 23 9 2.7 2324 32 3. 4. 7.9.3. 47 49 44 34 2 24 2.29 2344 3 43. 2...44. 49 47 3 32 2 3.2 293 3 4. 3..9.9.4 3 42 3 3 4.34 3934 2.7. 3..7.4 34 3 2.7 2439 27.9 4. 4.97.4.7 39 4 29 3 22. 2343 23 34.2 2..9.3. 42 44 3 2 3 " 2. 23334 2 2 4.4 29.4 7..4. 4 47 39 2 22 9 3.7 273 32 4. 39.2.2.7.2 47 49 44 34 27 24 34.22 333 3 2..3 9.3.4. 49 2 47 39 32 2 3.22 324 39 9. 2. 9.2.7. 4 43 3 32 2.37 234 3. 9. 4.7.2.4 3 37 24 2.7 9294 3. 4.3..73. 4 4 3 3.2 2334 2 4. 2. 7..4.2 43 4 3 22 4 " 3.2 2734 29 23 4.3 27.9...4 4 4 4 2 22 9 4.47 34 33 2. 3. 9.32.47. 4 44 33 27 24 4. 3443 3 9.9 4.2.43.. 2 47 3 32 2.229 3744 39 77. 7..33.9. 2 4 42 3 3 NOTES: See pages K34 and K4 for correction factors and notes. Providing You With Air Distribution Solutions K33

K K34, / Blade Thickness, Performance Data IP/METRIC DATA:,, DEFLECTION, / BARS, /4 BAR SPACING (NO OBD) IP Data Metric Data Nom. Air Press Perpendicular Nom. Air Press Perpendicular Duct Flow Pv Throw NC Duct Flow Pv Throw Octave Band, db in. CFM/ft "WG ft mm L/s/m Pa m 2 3 4 7 2.23 424 3.. 4..22.3 33 34 27.43 924 42.7..7.4. 3 4 27 3.9 2434 23 4.3 7.2 7.2..4 42 44 34 2 4 2 " 42.2 29429 29 24. 2.3.72.. 4 4 4 27 2.4 3444 33 77. 3..33.9. 4 44 34 27 24 7. 39499 37 9.3 4.3.4.2. 3 4 39 33 29.23 42273 4.9 9.2 2.9.22.3 3 2 44 37 33 22. 324 34.2 4. 4..22.3 32 33 3.34 2 4....4.2 37 3 24 3. 233 2 9. 3.7 7..7. 4 43 3 2" 4. 2422 2 3 7.4 2..2.9. 4 4 37 23 4. 33477 3 3. 27..4.42.3 47 49 42 3 24 2 2.4 372 3 9.3 3.4..42. 2 4 3 29 2 7. 4347 3.7 4.4 3..423. 2 4 49 4 34 3 3.2 2 4...3..4 3 3 2 4.42 22337 2..4.7.7.3 4 4 29 2 49. 2742 23 7...2.9. 43 4 3 2 2 4".3 3477 27 3 9. 2.7 9.4.22. 4 4 4 27 2 7.9 372 3 4. 27...22. 49 44 32 2 23 7.3 4477 3. 34.4 2.2.23.3 3 47 37 3 27.7 47 3 32. 42. 3.7.424. 3 42 3 3 3.9 2447 4. 4. 4.7.24.4 33 34 7 4.33 232 2..2.49.7. 3 39 2.2 244 2 77. 2.9.2.9. 42 43 32 ".7 32477 27 4 93.. 9.4.42.4 4 47 37 23 7. 3747 3.7 2.3.2.423. 4 42 29 23 2.33 42 3 24.2 33. 2.7.24.7 2 4 34 2 2 9. 47 3 39.7 4. 4.4.2.2 2 4 49 39 33 29 42.29 239.2 7..39.7.9 3 3 24 4.44 239 3..9 7..2. 42 43 3.2 3472 24 2.. 9.34.2. 4 47 37 22 7 " 7.4 3477 29 47 2. 2.9.9.323. 4 42 29 23 2 9.9 42 32 39.7 27. 2.47.72. 2 4 3 29 2 2.37 427 3.4 34. 3.9.2. 2 49 4 33 3 4. 92 39 77. 4.9.49.27.9 4 7 3 44 3 34 3. 249 4.3 4. 4.97.. 33 33 47.29 22333 73.7 7.3..29. 3 39 24.47 2427 2 93...2.2.4 42 43 3 2" 72. 3477 2 2. 7..3.23. 4 47 37 22 7 4.94 494 3 32. 23.4 2..2. 4 4 29 23 2 97.24 449 3.4 3. 3.99.327.3 2 4 34 2 2.7 279 3 7. 39.2.72.29. 2 49 39 33 29 4.4 2 2. 3. 4.7.. 33 33.27 2437.4.7 7..72. 3 39 24 7.44 347 2.7.9 9.3.23. 42 43 3 4 24".4 344 2 32....2. 4 47 37 22 4.9 4349 3.2 22.2 3.9.27.7 4 4 2 23 2. 4999 3 7. 29.3 4.92.29.7 3 4 34 2 2 3. 734 3 2. 37..922.33. 3 49 39 33 29 LENGTH & NC CORRECTION FACTORS Active Length 2 4 2 Throw Correction (Multiply).72...7. Active Length 2 4 NC Throw Correction (Add) 3.. 2. 3.. www.kruegerhvac.com Excellence in Air Distribution NOTES: When the diffuser is used as a return, increase the NC by (4) and the negative static pressure, which is (.) times the listed total pressure shown. See additional notes on page K4. KRUEGER 22

K, / Blade Thickness, Performance Data KRUEGER 22 IP/METRIC DATA:,, DEFLECTION, / BARS, /2 BAR SPACING (NO OBD) IP Data Metric Data Nom. Air Press Perpendicular Nom. Air Press Perpendicular Duct Flow Pv Throw NC Duct Flow Pv Throw Octave Band, db in. CFM/ft "WG ft mm L/s/m Pa m 2 3 4 7 4.3 7.2 7.7 2.3.. 24 2 3.9 22 9.3 7.3 3.4.. 3 33 2 4.24 32 22 2.4 3. 4..7. 3 3 34 2 4 2".93 7229 2. 4...2.7 4 43 4 34 27 22 2.27 2232 33. 9.2..9. 43 4 4 4 34 2 4.37 22434 3 2.7 94.2.7.3.4 4 49 47 4 34.494 223 42 24. 23..47.. 4 4 2 4 3.2 72 7.. 2.23.3.2 24 2 2.3 72 2.4.7 3..27. 32 33 2 3.9 23 23 7. 29.7 4..9.2 37 39 3 2 9 2 /2" 4.93 22434 3 4 2.7 4..7.3.4 4 44 42 3 2 23 7.2 22273 3 2.4 7.9...4 44 47 47 43 3 3 2.394 23294 4 3. 9. 7..72.4 47 2 49 42 3 23.2 2344 44 3.7 29.7 7.79.43.3 49 3 47 4.2 22 9.3.3 2.33.. 23 24. 3929. 4. 3.9..7 32 34 2 3 4.7 2434 24 2.7 29..47.3.4 3 4 3 2 2 3".93 222739 3 7 27.9 4...3.7 42 4 43 3 29 24 22.2 2343 3 34.2 7. 7.9.23. 4 49 4 44 37 3 2.43 27334 4 4.4.3..4. 4 2 3 43 37 3.3 293 4 4. 33..7.7.2 4 7 4 42.2 942 2.4.4 2.4.27. 2 27 4 2.7 4232. 4.3 4.2.39. 33 34 2 3.2 23 23 24. 2.4.7.. 37 4 34 24 4 3 /2" 2.9 23294 29 9 3. 39.7 7..72.4 4 44 4 33 2 22 24.23 2324 34 37.3 7.2 7.9.3. 44 47 4 4 33 2 2.33 2344 39 43. 77...44. 47 4 39 33 32.4 33 42 49.7.7 9...7 49 3 4 2 44 3.29 29. 7. 3.24..7 27 29 4. 233 22. 4.9 4.77.. 34 3 27 4 9.3 224 23 29. 2.7..2. 3 4 3 2 9 4" 23. 2344 3 2 3. 39.3 7.9.3.4 42 44 4 34 27 22 2.224 2344 3 43..7..44. 4 4 4 4 33 2 32.32 3372 39. 7. 9..2. 47 4 39 34 37.39 3239 42 7.4 97.3 9.7.9. 49 3 4 44 3 4.33 3234 2.7. 4..9.4 3 3 9 9. 274 29...4.2. 3 37 2 24.9 22324 24 37.3 23.9.9.3. 39 4 3 2 9 " 29.4 27349 29 27 4. 3..2.4.9 42 44 4 32 2 2 34.93 333 34 2. 4. 9.3.4. 44 47 4 39 32 27 39.24 3347 3. 3.2.2.27.3 47 49 44 37 32 44.323 343 4.3..3..4 49 2 3 49 4 3.2 393 23.3. 3..7.7 2 29 2.4 242 32. 2..4.2.7 34 3 2 2 27. 233347 22 4.9 9.9.9.24.4 3 4 33 22 2 " 33.9 2372 2 2.2 29.7.4.2.9 4 44 39 3 23 9 39. 3347 32. 4.4 9.92.27.3 44 47 44 3 3 2 4.222 343 37 9.9.2.73.. 4 49 4 42 3 3.2 34 4 79.2 7.9.44.9. 49 2 2 47 4 34 2.23 424 3..7 4.3.2.4 29 3 2.4 234 43..2.9.4. 34 3 2 2 3.74 239 22.9. 7..7. 39 4 33 22 3 " 44. 343 2 23.3 27.7 9.3..4 42 44 39 3 23 9 2. 374 33.7 3..34.2. 4 47 44 3 3 2.27 47 37 93..4 2.4.22.4 47 4 42 3 3.2 4337 4.. 3.2.22. 49 2 2 47 4 3 NOTE: See pages K3 and K4 for correction factors and notes. Providing You With Air Distribution Solutions K3

K K3, / Blade Thickness, Performance Data IP/METRIC DATA:,, DEFLECTION, / BARS, /2 BAR SPACING (NO DAMPER) IP Data Metric Data Nom. Air Press Perpendicular Nom. Air Press Perpendicular Duct Flow Pv Throw NC Duct Flow Pv Throw Octave Band, db in. CFM/ft "WG ft mm L/s/m Pa m 2 3 4 7 3.32 929 4. 7.9..7.2 32 34 22 4. 23 2. 4. 7.7.7. 37 39 3 7 2. 3244 2 77. 2.9 9.3.9. 4 43 37 2 2 ".27 37 3 24 93. 3...22.4 44 4 42 33 27 23 7.73 4447 3.7 43. 3.4.423. 47 49 47 39 33 2.22 47 39 24.2.2 4.37.24.7 49 2 4 3 33 9.2 43 39.7 7..2.2.2 4 4 49 42 37 3.29 234 4.3 7.3.9.2.4 32 34 2 4.4 239 9.9 2. 7.9.. 37 3 29.72 32477 24.4 7.9 9.4.42. 4 42 3 23 7 4 2". 37273 29 3.9 2..4.22.3 43 4 4 3 23 2 7.34 4379 33.4 33.4 3..924. 4 4 44 3 29 2.72 494 3 32. 42.9 4.7.2. 47 47 4 33 29 9.2 39 4 47. 3..9.27. 49 2 4 3 33 4.27 232 2...49.77. 33 34 2 4. 29437 3. 2..73.2.3 3 39 3.79 337 2. 9...22. 42 44 37 2 2 4" 2. 432 3 3 27.3 2. 3.27.72. 4 47 42 33 27 23 9. 39 3 49. 39.4.9.227. 47 47 39 33 2.2 79 4 7...2.29. 2 4 3 33 24.24 972 43 92.. 7.2.3. 2 4 49 42 37.32 2374 77.. 7..39. 3 3 24 4.3 324773 2 99.4 3.2 9.4.422. 39 4 3 2 7.79 397 27 2. 9..77.324.4 42 44 37 2 2 7 " 92. 427 3 4 42. 27.3 3..2. 4 47 42 33 2 22.4 294 3 4. 3.3.92.2. 47 4 3 32 27 2.7 7 39.3 4. 7.2.43.3 49 2 43 3 32 34.233 74 42 2...22.32. 4 3 47 4 3.3 2427 93. 9..2.72.4 3 37 2 74. 3427 22 4.9 3...723. 4 4 33 2 4.7 4 27 3. 9. 2.4.42. 42 4 3 2 2 7 " 2. 4792 3 47.4 2.3 4.49.27.9 4 47 42 32 2 22.3 499 3. 34..42.29. 47 4 37 3 27 3.7 734 3 2. 42..222.33. 49 2 49 42 3 3 44.2 3779 4 223. 2.3 9.223.33.2 4 2 4 39 34 7.4 347.7 9.9 9.44.23. 37 39 2 3.9 374 23 32. 4..47.2. 4 42 34 2 2. 4449 2.2 2.3 3.49.27.7 43 4 39 2 2 2". 99 32 7. 2..42.29.7 4 4 43 33 27 23 3.3 7734 3 2. 34.2 7.422.33. 4 4 3 3 27 4.7 377 39 22. 42. 9.223.33.3 49 2 49 42 3 3.2 42 24.4.9 2.224.73. 4 2 4 39 34.3 324 24.2.9 9.74.24.7 37 3 27 2 9.4 3999 23 2. 3.3.97.927.4 4 42 33 2 4 2.7 499 2..7 4.2.29. 43 4 3 27 2 24" 34. 474 32 2. 24.9.322.32. 4 4 42 32 2 23 2.29 792 3 23. 32..24.34. 4 4 37 3 27 7. 49 39 23.9 4. 2.72.3. 2 49 42 3 3.97 722 42 29.9 49. 2.92.37.9 4 2 4 39 34 LENGTH & NC CORRECTION FACTORS Active Length 2 4 2 Throw Correction (Multiply).72...7. Active Length 2 4 NC Throw Correction (Add) 3.. 2. 3.. www.kruegerhvac.com Excellence in Air Distribution NOTES: When the diffuser is used as a return, increase the NC by (4) and the negative static pressure, which is (.) times the listed total pressure shown. See additional notes on page K4. KRUEGER 22

K, / Blade Thickness, Performance Data KRUEGER 22 IP/METRIC DATA:,, DEFLECTION, / BARS, /4 BAR SPACING (NO DAMPER) IP Data Metric Data Nom. Air Press Perpendicular Nom. Air Press Perpendicular Duct Flow Pv Throw NC Duct Flow Pv Throw Octave Band, db in. CFM/ft "WG ft mm L/s/m Pa m 2 3 4 7 3.2 4.7.9.2.44. 33 34 9 4.49 7.2 2.2 2.23.2. 3 39 27.77 932 22 7. 9. 2.74..2 42 43 34 2 4 2". 22 27 9.3 27.4 3.24.. 4 47 39 27 2 7. 2724 32.9 37.4 3..27.3 47 43 33 27 23.9 42 3 2.4 4. 4.3.7. 49 2 47 39 32 2 9.24 927 39 4.. 4..9.3 4 43 3 32 3.4 474 4.7 3..22.4.2 29 29.39 2 7. 9.7 2.33..2 37 3 2 7.77 24 23.9 9. 3.34.97.3 43 44 3 2 3 2 /2" 9.27 4927 3 4 4. 3. 4.2.9.3 47 49 42 3 2 2.9 723 3 7. 47...9.2 3 4 39 33 2 3.24 92333 4 2.2.7.7.. 3 3 4 39 34.3 223 4 23.3 7..27..7 9 7 44 39 4..2 3..2.. 3 3 2.34 222 9.3. 2.3.7. 37 3 24. 2 2 2.4. 3.3.7. 42 43 32 7 2 3".9 4229 27 7. 23. 4.2.2.7 4 47 39 2 2 7 2.3 2232 33. 33.9..9. 49 44 33 27 24 4. 92434 37 2.7 4..7.3.4 4 49 4 33 29.242 223 4 24..2.47.. 3 3 4 3 34. 99 7. 3.9.92..7 3 32 3 7.3 942..9 2.4.37. 3 39 2.3 2929 22.. 3..7.7 43 44 34 9 4 3 /2" 2.99 2332 29 9 9.4 24. 4.7.99. 47 49 4 2 22 9.42 923 34 23.3 3.4.77..7 2 4 3 29 2 7.94 22273 3 27.2 4.2..2. 2 4 3 3 2.23 23294 42 3. 3. 7..72.4 7 4 4 4 3. 97 7. 2..2..2 29 29.29 942 2.4 7.2 2.4.27. 37 3 23. 393 2 7. 3. 3..9.2 42 44 32 7 4" 4.9 2434 2 2 2.7 22. 4.97.3.4 4 4 39 2 2 7.3 2273 34 2.4 32..9..4 2 4 34 2 24 2. 23294 3 3. 4. 7..72.4 2 4 34 3 23.24 2344 42 3.7 9.7 7.79.43.3 7 4 4 39 3. 9 9.3 2.4.42.. 29 2.2 29.. 3.4..7 37 3 23 4.2 4234 2 2.7 2.9 4.3..4 43 44 33 7 ". 2739 29 27 27.9 2.4..3.7 47 49 4 27 2 22.2 22343 34 34.2 3.9.9.23. 3 4 3 29 2 2.79 2334 39 4.4 44...4. 3 4 3 3 3.23 293 43 4. 9.4.7.7.2 47 4 3. 22 2.4 2..93.3.7 3 3 2.2 32..2 3.3.9. 3 3 23.44 223 2 24.. 4..7. 42 44 3 " 2.9 274 27 2 3. 7.3..32.4 4 4 3 23 24. 22324 32 37.3 24.9.79.3. 49 43 3 2 22 2.3 2344 3 43. 33.9 7..44. 2 4 47 37 3 27 32.7 293 4 49.7 44.3.9..7 4 42 3 32.9 223. 2.3.3.7. 3 3.23 393 24.. 3..7. 3 39 23 22.44 7243 2 34.2..27.93. 44 4 32 " 2.7 22334 2 23 43. 7..7.4. 4 49 39 2 2 7 34. 2733 34 2. 2.2..4. 3 4 33 27 24 4.4 34 39 2. 3.3 9.2.47. 4 39 33 29 4.93 3442 43 7.4 4..3.3. 4 4 3 34 NOTE: See pages K3 and K4 for correction factors and notes. Providing You With Air Distribution Solutions K37

K K3, / Blade Thickness, Performance Data IP/METRIC DATA:,, DEFLECTION, / BARS, /4 BAR SPACING (NO DAMPER) IP Data Metric Data Nom. Air Press Perpendicular Nom. Air Press Perpendicular Duct Flow Pv Throw NC Duct Flow Pv Throw Octave Band, db in. CFM/ft "WG ft mm L/s/m Pa m 2 3 4 7 4. 29 2.7 2.7 2.4.4.9 33 33 3 2.2 2242 32.. 4.4.72.7 4 4 2 2.44 9294 23 43..9.9.94. 44 4 33 " 3. 2434 29 24 4.3 7. 7.4..4 4 4 2 2 7 42.99 29429 34.2 24..92.77.9 3 4 33 27 24 49.34 3444 3 7. 33.4.43.79.4 4 49 39 32 29.7 394 42.9 43.7.4.2.7 3 44 3 34.2 734 27.9 3. 3..2.4 3 3 2.24 244 3..9 4.7.23. 4 4 2 32.39 23 22 49.7 9..9.2.7 44 4 32 2" 39.7 2377 27 3. 4.3 7..27.3 4 49 3 23 7 4. 29442 32 7.4 9.9.3.2. 2 43 29 23 2 3. 3347 3 2.3 2.4.24.22. 3 47 3 29 2.3 37 4 93. 33.9..22.4 7 4 34 3 2. 73 3. 2.7 3..3. 34 34 4 3.2 72 4...3..2 4 42 2 4.44 233 24 2..9 7..7. 4 47 3 3 4". 29444 3 3 77. 7..93.39. 4 27 2 9.9 37 3 93. 24.4..22.4 3 4 4 34 2 2 7.34 447 4.7 33.2 2.4.423. 7 4 34 3.74 47 44 24.2 43.4 4.27.24.7 7 4 39 3 2. 33 3. 2. 2..9.9 32 32 32.2 72 49.7.2.37.9.7 4 4 24 44.4 243 23.3 9.9 7.3.9.4 4 47 34 7 2 ". 34 3 4.9. 9.33.92.7 4 2 2.9 3737 3. 23.7.2.22. 3 4 34 2 2.32 43 4 24.2 32. 3.27.24.7 4 34 3 92.74 27 44 42. 43.4.2.2. 4 39 3 22. 734 34.2.9 2...3 32 32 34.9 722 2. 4..37.9.9 4 4 23 4.34 2432 22 7.4. 7.2.7. 4 4 32 4 ".4 3449 2 47 9. 3. 9.3.2. 49 39 23 7.79 347 34.7 9..9.323. 2 4 44 3 2 22 2. 422 3 27.3 2.9 2.77.72. 49 37 3 2 94.42 42 42 4.9 3.4 4.9.2. 7 9 3 42 3 33 24.7 73 37.3.9 2..3. 32 32 37. 274 7.4 4.4.4.2.3 4 4 23.32 2434 2 77.. 7.4.9. 4 4 32 3 2" 3. 3472 2 97. 2. 9.33.922. 49 3 22 7 7.7 3779 33...2.24. 2 3 44 3 24 22 9.2 43 3 3.2 2. 3..2. 4 4 3 3 27 2.34 4992 42.4 33.4.9.27.9 7 9 2 42 3 32 2.7 9937 43..7 2...3 33 32 42. 92.2 3.9..4.9 39 4 22.2 237 2.9.9 7..32.7 44 4 3 24" 7.43 347 27.7. 9.44.23. 4 49 37 2 3 4.2 373 32 3.4..3.92.4 3 42 27 22 2 9. 4349 3 2. 2.2 3.9.427.4 4 47 33 2 2 2. 499 4 73.9 27..2.729.3 39 33 3 LENGTH & NC CORRECTION FACTORS Active Length 2 4 2 Throw Correction (Multiply).72...7. Active Length 2 4 NC Throw Correction (Add) 3.. 2. 3.. www.kruegerhvac.com Excellence in Air Distribution NOTES: When the diffuser is used as a return, increase the NC by (4) and the negative static pressure, which is (.) times the listed total pressure shown. See additional notes on page K4. KRUEGER 22

K, / Blade Thickness, Performance Data KRUEGER 22 IP/METRIC DATA:,, DEFLECTION, / BARS, /2 BAR SPACING (NO DAMPER) IP Data Metric Data Nom. Air Press Perpendicular Nom. Air Press Perpendicular Duct Flow Pv Throw NC Duct Flow Pv Throw Octave Band, db in. CFM/ft "WG ft mm L/s/m Pa m 2 3 4 7 4.3 7.2 7.7 2.3.. 3 32 2. 942. 4. 2.4.2. 3 3 29 7.94 2724 24.9 23. 3..27.3 4 42 3 2 9 2".39 4927 3 3.2 34. 4.3.7. 43 4 42 33 27 22.93 7229 34. 4...2.7 4 49 4 4 33 2.2 223 3 7.9 3.4.4.9.4 4 4 3 33 3.32 92333 42 2.2..7.. 3 4 43 37.2 72 7.. 2.23.3.2 3 3 7 7.4 24.9 2. 3.4.7.3 3 37 27 4 9. 3927 23 4. 9. 3.9.9.3 4 42 3 24 7 4 2 /2".9 23 29 4 7. 29. 4..9.2 43 4 4 32 2 2 3. 92333 34 2.2 4.4.77.. 4 4 4 3 3 27.22 223 3 23.3..27..7 4 44 37 32 7.24 22273 4 2.4 7.7...4 3 3 49 42 3.3 2 2.4 9. 3.4.77. 34 3 2.9 3929. 4. 3.9..7 3 4 3 9 3 2. 2232 2. 2.3 4.7.9. 4 43 37 2 2 3" 4.7 2434 3 7 2.7 29..47.3.4 44 4 4 32 2 2.2 223 33 24. 37.9.27.. 4 49 4 37 3 2.93 222739 37 27.9 4...3.7 4 49 42 3 3 2.23 23294 4 3. 9.2 7..72.4 3 2 4 39 34.2 942 2.4.3 2.4.27. 32 33 2.4 393 7. 2. 3.9.9.2 37 39 29 4.7 2434 2 2.7 9.4 4.97.3.4 4 43 3 2 9 3 /2" 7. 2273 3 9 2.4 2....4 44 47 42 33 2 22 2.9 23294 3 3. 39. 7..72.4 47 47 39 32 2 23.2 2344 39 3.7 2.4 7.79.43.3 49 2 4 3 33 2.29 27334 42 4.4 7...4. 4 49 42 37.2 29. 7. 3.34.9.7 33 34 22 3.4 4233 2.2 2. 4.2.3. 3 39 3.73 723 24 24..2.27.. 4 43 3 24 4" 9.3 224 29 2 29. 2..2.2. 44 4 4 3 2 2 22.3 24343 34 34.2 34.3 7.29.23. 47 49 4 37 3 2 2.7 2324 37 3. 44.3.9.3. 49 49 42 3 3 2.223 2344 4 43....44. 4 2 4 39 34 2.24 732.. 3.4.9. 33 34 2.43 233 24.. 4..9. 3 39 29 2.7 924 24 3...7.2.4 4 43 3 23 4 " 24.9 23324 3 27 37.3 23.9.99.3. 4 47 4 3 24 2 2.3 2344 34 43. 32...44. 47 4 37 3 2 32.7 33 3 49.7 42. 9...7 49 2 49 42 3 3 3.2 3239 4.9 3. 9..7. 4 3 47 4 3 4.2 234 2.7.3 3..4.4 33 34 2 9.39 244 29. 9. 4.97.42. 3 39 29 4 24.3 234 24 37.3.7.29.33. 42 44 3 23 7 4 " 29.92 2349 3 2 4. 22.9 7..4.9 4 47 4 3 24 2 34.2 2933 34 2. 3.4..4. 4 4 37 3 2 39. 3347 3. 4.4.2.27.3 3 42 3 3 44.2 343 42.3 2..3..4 2 3 47 4 3 2.23 4224 3..7 4.4.2.4 3 3 22 2.39 924 4.4 9..7.4. 39 4 3 32.9 233 2 49.7 4. 7...7 42 44 3 23 7 4 " 3.3 24 3 23 9. 2..42.7. 4 47 4 3 24 2 44. 3243 34.3 27. 9.73..4 4 4 3 29 2.43 344 3 77. 3..3.9. 3 49 4 34 3. 394 4.9 44.7 2.4.2.7 2 2 4 3 34 NOTE: See pages K3 and K4 for correction factors and notes. Providing You With Air Distribution Solutions K39

K K4, / Blade Thickness, Performance Data IP/METRIC DATA:,, DEFLECTION, / BARS, /2 BAR SPACING (NO DAMPER) IP Data Metric Data Nom. Air Press Perpendicular Nom. Air Press Perpendicular Duct Flow Pv Throw NC Duct Flow Pv Throw Octave Band, db in. CFM/ft "WG ft mm L/s/m Pa m 2 3 4 7 22.7 4242 34.2 4.2 4.3.42.9 33 34 9 3.32 929 4. 7.9.9..2 3 4 2 2 3. 2437 24 9. 2. 7.4.7. 42 44 3 2 3 " 4.74 3442 29 24 7.4. 9.3.3. 4 47 4 29 23 9 4.3 3477 34 3. 2..4.42.3 4 4 3 29 2 2.3 472 3 9.3 33.7 2..42. 3 49 4 34 3 7.72 4447 4.7 42.9 3.4.423. 3 3 4 39 34 2. 2244 3. 3.7 4.4.73.3 33 33 34.27 233 2...9.. 3 39 27 43.44 23 23..9 7..4. 42 43 33 9 4 2" 2.4 34 2 3.7. 9.23.2. 4 47 39 27 2. 37 33 94.7 22...32. 4 44 33 27 23 7.7 447 37.7 29. 2.4.423. 2 4 3 32 2 79.4 47 4 22. 37. 4.7.424. 2 43 37 32 3. 244 4. 3. 4.97.44.7 34 34 9 4.27 2232 2...9.7. 3 4 27.43 2744 23 77..7.22.39. 42 44 34 9 4 4".2 3247 2 3 93..4 9.4.72.4 4 47 39 2 2 7.4 347 33.7 2.9.4.423. 4 43 33 2 23. 43 37 24.2 27.3 3.7.24.7 2 47 3 32 2 9.39 4 4 39.7 34. 4.7.2.2 2 43 3 32 3. 23 4.3 3.9.3.. 34 3 2 47.29 2433 73.7 7.3 7.2.99. 4 4 29 2.47 347 2 93.. 9.23.72.4 43 4 3 2 3 " 72. 377 3 4 2..9..23. 47 49 4 29 23 2.93 4394 3 32. 23.3 3..2. 49 2 4 3 29 2 97.23 4949 39.4 3. 4.99.327.3 2 4 4 34 3.7 79 42 7. 39..2.29. 4 3 4 39 34 4. 927 2. 4..7.7.2 3 3 2 2.2 237..9 7..32. 4 4 2 2.43 3473 24.9. 9.34.22.3 43 4 3 2 2 " 77. 37 29 47 2.3...724.4 4 4 4 27 2 9 9.2 42 34 39.7 2.4 2.9.2.2 49 44 33 27 24 2. 492 37 9. 2. 4.79.2. 3 4 3 32 2.34 499 4 7. 33.3.2.29.7 3 43 3 32.2 22344 77....29. 37 3 24 4.33 294373 2 99.4.3.73.22. 42 43 3 7.49 32 27 2. 2.3..924.4 4 47 37 24 2" 92.9 427 32 42. 7. 2..2. 4 42 3 24 2.9 4794 3 4. 22.7 4.42.2. 2 4 3 3 2 2.7 47 39.3 29..32.43.3 2 4 34 3 34.4 74 42 2. 3.3.222.32. 4 7 3 4 3 34.2 24377 93.. 7.4.2.4 3 39 2 7.3 3479 2.4 7. 9.33.924. 42 43 3 9.4 37 2 39.7.2..72.2 4 4 37 23 7 24". 43493 3 3..3 3.9.2.3 47 49 4 29 23 2 2. 497 3.3 2. 4.2.43.3 2 4 34 2 2 3. 7 3 29. 2.3.722.732. 2 4 49 39 32 29.2 79 4 232.9 3.2.24.33.9 3 2 43 3 32 NOTES: Throw values are given for isothermal conditions and terminal velocities of,, and FPM (.7,., and.2 m/s). NC values are based on octave band 2 7 sound power levels minus a room absorption of db, re 2 Watts. Dash in space denotes a NC or db value of less than. Nominal duct is duct width. Data was obtained from tests conducted in accordance with ANSI/ASHRAE Standard 7, ISO Standard 29, and ISO Standard 374. Maximum width is 2 (3). See Krueger s selection program for performance data not shown, including octave band data. www.kruegerhvac.com Excellence in Air Distribution KRUEGER 22

K, / Blade Thickness Suggested Specification & Configuration. SERIES: (XXXX) Aluminum Linear Bar Grille (/ Bars) 2. LENGTH: CANNOT EXCEED (XXX.XXX) 999 in / Increments 3. : (XX.XX) 2 24 in /4 Increments 4. BAR SPACING: (X) N Normal /4 * E Every Other Bar /2. DEFLECTION: (XX) or. FRAME: (XX) CODE PLASTER A /4 AE /4 B BE C 3/4 CE 3/4 D /2 DS /2 R /4 RG /4 7. MOUNTING: (XX) ** None Spring Clip 2 Surface Mount Concealed * 3 Screw Hole Mounting. END BORDER: (X) End Cap Both Sides B Both Ends Butt Cut L Left End Butt Cut R Right End Butt Cut 9. DAMPER: (XX) No Damper 9 SBD Steel LOBD 2 SBD Aluminum LOBD. ACCESSORIES: (XX) (XX) No Accessories B Blankoff Strip L Linear Straightening Grid AD Access Door The linear bar grille shall be Krueger model with / thick fixed bars at or deflection spaced on /4 centers or / thick fixed bars at or deflection spaced on /2 centers (every other). The shall be constructed of extruded aluminum with the maximum single length of 72. Units longer than 72 shall be provided in multiple sections and assembled with alignment strips or pins provided by the manufacturer yielding a continuous linear appearance. When end pieces require an end cap, the end cap must be mitered and mechanically attached to the linear frame. Screw attachment of end caps will not be accepted. The linear bar core shall be locked to the extruded aluminum frame with the fixed deflection bars running parallel to the longest dimension. Support bars for the core must not exceed 9 on center spacing. Optional linear opposed blade damper (LOBD) shall be constructed of heavy gage steel (aluminum also available as LOBD). Damper shall be operable from the face of the grille. Optional curving of linear bar grilles to a minimum of 72 radius is available upon request. PERFORMANCE The manufacturer shall provide published (printed or electronic) performance data for the diffuser. Performance data shall include 2 7 octave band sound power levels. The diffuser shall be tested in accordance to the data standards at the time of product introduction or ANSI/ASHRAE Standard 7. FINISH The paint finish shall be #44 British White and be an anodic acrylic paint, baked at 3 F for 3 minutes. The paint thickness shall be.. mils, gloss at per ASTM D23 9 of %, pencil hardness per ASTM D33392A of HB H, crosshatch adhesion per ASTM D3393 of 4B B, impact per ASTM D279493 of direct impact > in/lb and reverse impact > in/lb, salt spray per ASTM B794 of 9 hours, humidity per ASTM D224792 of > hours and water soak per ASTM D792 of 2 hours. KRUEGER 22.FINISH: (XX) Mill Alumican 3 Black 44 British White Lengths greater than 72 are in multiple sections. * Concealed mounting not available with damper and/or Normal /4 bar spacing. ** All mounting for Frame R is by others. Clear and Bronze anodizing available. SAMPLE CONFIGURATION: 44x N B 44 Providing You With Air Distribution Solutions K4

K, / Blade Thickness Suggested Specification & Configuration The linear floor bar grille shall be Krueger model with / thick fixed bars at or deflection spaced on /4 centers or / thick fixed bars at or deflection spaced on /2 centers (every other). The shall be constructed of extruded aluminum with the maximum single length of 72. Units longer than 72 shall be provided in multiple sections. When end pieces require an end cap, the end cap must be mitered and welded to the linear frame. Screw attachment of end caps will not be accepted. The linear bar core shall be removable with the fixed deflection bars running parallel to the longest dimension. Support bars for the core must not exceed on center spacing. Optional linear opposed blade damper (LOBD) shall be constructed of heavy gage steel (aluminum also available as LOBD). Damper shall be operable from the face of the grille. Optional curving of linear bar grilles to a minimum of 72 radius is available upon request. PERFORMANCE The manufacturer shall provide published (printed or electronic) performance data for the diffuser. Performance data shall include 2 7 octave band sound power levels. The diffuser shall be tested in accordance to the data standards at the time of product introduction or ANSI/ASHRAE Standard 7. FINISH The paint finish shall be # Alumican and be an anodic acrylic paint, baked at 3 F for 3 minutes. The paint thickness shall be.. mils, gloss at per ASTM D239 of %, pencil hardness per ASTM D33392A of HB H, crosshatch adhesion per ASTM D3393 of 4B B, impact per ASTM D279493 of direct impact > in/lb and reverse impact > in/lb, salt spray per ASTM B794 of 9 hours, humidity per ASTM D224792 of > hours and water soak per ASTM D792 of 2 hours.. SERIES: (XXXX) Aluminum Linear Bar Floor Grille (/ Bars) 2. LENGTH: CANNOT EXCEED (XXX.XXX) 999 in / Increments 3. : (XX.XX) 2 2 in /4 Increments 4. BAR SPACING: (X) N Normal /4 E Every Other Bar /2. DEFLECTION: (XX) or. FRAME: (X) H /4 M N 3/ 7. MOUNTING: (XX) None Spring Clip * 3 Screw Hole Mounting *. END BORDER: (X) End Cap Both Sides B Both Ends Butt Cut L Left End Butt Cut R Right End Butt Cut 9. DAMPER: (XX) No Damper Steel LOBD Aluminum LOBD. ACCESSORIES: (X) (X) No Accessories B Blankoff Strip L Linear Straightening Grid.FINISH: (XX) Mill Alumican 3 Black 44 British White SAMPLE CONFIGURATION: 24.7x E M 3 K42 www.kruegerhvac.com Excellence in Air Distribution Lengths greater than 72 are in multiple sections. * Fastening methods not available with Frame N. Damper available for widths 3 or greater. Clear and Bronze anodizing available. KRUEGER 22