Page 1 of 5 1 1. (3.5cm) 1.7 (4.3cm) 4 5 Rectilinear 3 1.81 (4.6cm) Extruded Linear Louver.5 (.64cm) 5. (1.7cm) 9. (.86cm) 1 1. (3.5cm) 1.7 (4.3cm) 4 5 Tapered 3 1.81 (4.6cm).75 (.7cm) Feature Specifications Electrical Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off. Connections: Wiring is via 18 gauge wire. All electrical connections for standard configurations are plug-and-play via 6-wire cannon plug connections. Connections are seated in end castings of fixtures, allowing for simultaneous mechanical/ electrical coupling. Connectors are male/female therefore modules are directional, starting from the power feed end set. Male Female All static ballasts have the following features: Electronic Class A sound rating High Power Factor Metal can 5. (1.7cm) 1.375 (6.35cm) Emergency Battery Pack: 9 minute operation, 7 lumens for 54W and 5 lumens for 8W. EM pack fixtures ship with a 4th wire as standard. Use 4 wire power feed end set and order a 4th through wire in all non-em pack fixtures in that run. Dimming (Standard Control Option): Advance Mark 1 standard (no additional wires required) for T5HO fixtures. T5HO lamps can be dimmed down to 1%. T5 (non-ho) lamps use ULT Super-Dim 1 ballasts and can be dimmed down to 1%. A 5-wire power feed will be required for T5 (non-ho) dimming. Features 1. Housing: High purity extruded aluminum, a portion from recycled material. Mitered end caps [3" (7.6cm) rectilinear end cap and 3.69" (6.37cm) tapered end cap]. No exposed fasteners or hardware.. ing: Two T5 fluorescent lamps per 4-foot section. s not included. 3. Reflector: Precision die-formed premium anti-iridescent, highly reflective aluminum. 4. : Electronic. Meets ANSI starting, end-of-life protection and sound rating specifications. Low THD. Use ballasts with maximum height of 1.7" (4.3cm) and maximum depth of 1." (3.5cm). 5. Shielding: Extruded aluminum with die formed linear louver slots, finished to match housing. Mountings Cable suspension is on and centers and consists of a 4-1/" (11.43cm) diameter canopy finished white enamel. A 1/16" (.16cm) diameter stainless steel aircraft cable accomplishes suspension and is adjustable from 1" (3.48cm) to 36" (91.44cm). Power feed is 18-gauge SJT white jacket. For special circuiting consult factory. For mounting locations on a wall mounted fixture type, see specification sheet Argus-6 to Argus-33. Powder coated, baked enamel, white, black or aluminum, as specified. Custom colors available, consult factory. Labels UL, cul and I.B.E.W. Power Tray: Code-gauge, die-formed steel, pre-paint white enamel finish. Accepts ballasts up to 1.7 (4.3cm) wide by 1. (3.5cm) high. Power Feeds: Standard 18/3 power feed is rated for 1 amps. X4 power feed is 18/4 and is rated for 7 amps. Observe amperage limitations and provide additional Intermediate Power Cables, as required. When providing an additional power feed, the through wiring from the previous module must be disconnected from the cannon plug and capped. Dual Switching and Tandem Switching: Dual switched and Tandem switched fixtures ship with a 4th wire as standard. Use 4 wire power feed. Job Name: Cat. No.: (s): Notes:
Page of 5 Module Ordering Information Family A A = Argus Mounting P = Pendant W = Wall Series R = Rectilinear T = Tapered ing & Distribution = -, Open Top Shielding E E = Extruded Linear Louver See Chart Below Z = s not installed 4 = 4-Foot 8 = 8-Foot Voltage 1 = 1V = 77V U = UNV (1V-77V) 3 = 347V A = Aluminum On-Board Control 1 ST ST = Standard (none) (Blank) 4 = 4 through wires C = Dust Cover E = EM Pack S = Step Dim T = Tandem Switch 3 1 Standard fixtures ship with no On-Board Control systems. For explanation of On-Board Control features, see specification sheet: Argus-Control. For step dimming, use ballast F or G and option S. Step dimming is not available in 4' fixtures with an odd number of lamps. Order 4 wire power feed. 3 Tandem Switch available in 8-foot fixtures only. Tandem switch available in standard control only. NOTE: Voltage 1 or must be selected when using Dimming or EM Packs. Ordering Instructions 1. Determine run length.. Order the appropriate number of MODULES for the complete run. 3. Order one POWER FEED END SET for each run. 4. Order one CABLE ASSEMBLY per MODULE minus one per run. 5. For runs that exceed conductor ampacity ratings order the appropriate number of SINGLE CABLE & CORD SETS. Specifications Code Type Factor Start Type THD % F T5 1. Program <1 F* T5 Step Dim.95 Program <1 G T5HO 1. Program <1 G* T5HO Step Dim.95 Program <1 I Dim T5 1./.1 Program <1 J Dim T5HO 1./.5 Program <1 Other BF available, consult factory * For step dimming, use ballast F or G and option S. Feature T = Tandem Switching One- Plan View A B Tandem Switch fixtures ship with a 4th wire. Be sure to order the appropriate quantity of wires in the power feed. E = Emergency Battery Pack Hot A/C B. Hot A/C B. Common Unswitched EM B. Common Wall Switch Switched EM B. Standard Emergency wiring is to have Battery Pack operating a single lamp. All EM fixtures are wired as switched and include 4th through wire for the wall switch (see diagrams). All non-em pack fixtures and power feeds in that run should be ordered to include a dedicated 4th through wire to carry the hot power all the way through the run to the EM pack. (Option 4)
Page 3 of 5 Power Feed End Set Ordering Information End Set EC 36 EC = End Cap Set Power Feed End Set Order one per continuous run 36 = 36" A = Aluminum Blank = none 4 = 4 Wires 5 = 5 Wires 6 = 6 Wires Ceiling Grid Kit (For use when cable assemblies are being mounted directly on up to 15/16" inverted tee or 9/16" slot tee.) Both CGKP and CGK ship with two types of clips (inverted and slot T). For mounting fixtures directly to the T grid, order one CGKP per power suspension point and one CGK per non- powered suspension point. The CGKP will include a special canopy with flex coupler, grid clips and additional clips to mount the junction box to the top of the grid nearby. J-Box and flex conduit provided by others. L W Rectilinear L - 9. (.86cm) W - 3 (7.6cm) H - 1.81 (4.6cm) H L W Tapered L - 1.375 (6.35cm) W - 3.65 (9.1cm) H - 1.81 (4.6cm) H Ceiling Grid Kit, Power: CGKP Ceiling Grid Kit: CGK Cable/Cord Assembly Ordering Information Family AP C = Cable CC = Cable with Cord 36 36 = 36" Blank = none 4 = 4 Wires 5 = 5 Wires 6 = 6 Wires Corner Block Ordering Information* Corner Dimension 1 = 1" 4 = 4" 1" (3.48cm) Angle 9 9 = 9 A = Aluminum See NOTE Below 4" (6.96cm) 1" Corner Cable Assembly Order one per fixture, minus one per run. Cable/Cord Assembly When required for supplemental power feed. 4" Corner Supplemental Power Feed Requirements Consult and data to determine input watt requirements for ballast used on project to determine loading for each run. To determine ampacity, multiply the total number of ballasts by the input wattage per ballast and divide the total watts by the system voltage. 1 Amps for 3-wire end sets, 7 Amps for 4-wire and 5-wire end sets, maximum. Because most ceilings are white, all canopies ship as white unless specifically ordered otherwise. Regardless of canopy or end cap finish, power cord will be 18-gauge SJT white jacket unless specifically ordered otherwise. Inline Joiner Block Ordering Information* 4 = 48" 8 = 96" A = Aluminum See NOTE Below * will be required at each joint in the run. For suspension ordering purposes, consider each corner blocks and inline joiner as another fixture in the run. Corner blocks and inline joiners are unlit. NOTE: Argus Corner Blocks and Inline Joiner Blocks ship with the maximum # of wires, so they will work in any wiring configuration. Corner Blocks are field reversible.
Page 4 of 5 Sample Fixture s & Mounting Locations 4-Foot Indivdual 8-Foot Individual 1-Foot Run 4-Foot 8-Foot Module Module End Set Cable Joiner 4-Foot Indv. 1 1 8-Foot Indv. 1 1 1-Foot Run 1 1 1 1 16-Foot Run 1 1 -Foot Run 1 1 4-Foot Run 3 1 16-Foot Run -Foot Run 4-Foot Run NOTE: For overall run length, combine mounting distance and end cap length dimensions. Rectilinear end cap length: 3" (7.6cm) each. Tapered end cap length: 3.69" (9.37cm) each. Example 1: Mounting distance for a 4-foot run is 48". The overall run length for rectilinear fixture is 54"=3"+48"+3" and for tapered fixture is 55.38"=3.69"+48"+3.69". Example : Mounting distances for a -foot run are 96", 96" and 48". The overall run length for rectilinear fixture is 46"=3"+96"+96"+48"+3" and for tapered fixture is 47.38"=3.69"+96"+96"+48"+3.69" Sample Pattern Corner Block APx49W 4" (6.96cm) 96" (43.84cm) 1" (3.48cm) Corner Block APx19W
Page 5 of 5 Performance Two- Fixture with Open Top Candlepower Curve 375 75 115 18 15 17 1 16 15 3 14 4 13 5. 9. 1 6 11 1 7 9 8 Report No.: LLI187H.ies s: Philips -F54T5/835/HO Lumens: 5 Efficiency: 77.4 Cat. No.: APREGQ4UWST 5 C Rating Candlepower Zone 45 67 9 Degree Candelas 18 187 187 187 187 187 175 154 1464 133 15 16 165 1546 155 1487 149 146 155 144 151 1464 1448 1453 145 168 1375 1441 1477 1478 135 15 17 1369 1465 149 15 84 146 19 1435 148 115 537 8 1164 147 1488 15 69 633 14 169 151 95 53 17 9 19 181 9 13 13 14 14 13 85 33 6 1 19 18 75 16 7 55 5 48 65 36 14 99 86 83 55 343 66 153 131 15 45 44 373 33 194 183 35 57 54 368 94 59 5 591 644 489 4 394 15 641 641 681 67 553 5 664 659 63 68 61 633 633 633 633 633 Room Cavity Ratio Coefficients Of Utilization % Effective Ceiling Cavity Reflectance 8 7 5 % Wall Reflectance 5 3 1 5 3 1 5 3 1 77 77 77 68 68 68 5 5 5 1 67 64 61 59 56 54 44 4 41 58 53 5 51 47 44 38 36 34 3 51 45 41 45 4 37 34 31 8 4 45 39 35 4 35 31 3 6 4 5 4 34 9 35 3 6 6 3 6 35 3 5 31 6 3 4 18 7 3 6 8 3 1 18 15 8 9 3 19 5 1 17 19 16 13 9 6 17 3 18 15 18 14 1 1 4 18 15 1 16 13 16 13 1 % Floor Cavity Reflectance Distribution Zone Lumens % % Luminaire -9 1338.9 13.4 17.3 9-18 6397.5 64 8.7-18 7735.79 77.4 1 and Ordering Combinations Design Type Factor (BF) THD (%) Rated Wattage Rated Output* Color (Kelvin) IES Output (Lumens) Input Watts Efficiency (lum/watt) Life (Hours) FM/FN/FO T5 1 <1 8 6 M-3 N-35 O-41 6 33 78.8 5 Program FM/FN/FO T5 Step DIM.95 <1 8 6 M-3 N-35 O-41 494 58 85. N/A Program GP/GQ/GR T5HO 1 <1 54 5 P-3 Q-35 R-41 5 6 8.6 5 Program GP/GQ/GR T5HO Step DIM.8 <1 8 6 P-3 Q-35 R-41 416 58 71.7 N/A Program GV/GW/GX T5HO 1 <1 49 5 V-3 W-35 X-41 5 58 86. 5 Program IM/IN/IO T5 DIM 1. /.1 <1 8 6 M-3 N-35 O-41 6 /6 33.5 / 8 77.6 N/A Program JP/JQ/JR T5HO DIM 1. /.3 <1 54 5 P-3 Q-35 R-41 5 /15 63 /13 79.4 N/A Program JV/JW/JX T5HO DIM 1. /.3 <1 49 95 V-3 W-35 X-41 95 /89 63 /13 79.4 N/A Program Start Type Notes: *5 C Rating T5, T5HO, T5 DIM and T5HO DIM data is per 1 lamp on a two lamp system at 77 VAC. T5 Step DIM data is per lamp on a two lamp system at 77 VAC. Data is based on Philips Advance Specifications. s are not included with fixture. Average Rated Life (Hrs) 35 3 5 15 1 5.71 BF Program Start.88 BF Program Start Instant Start 1 3 4 5 6 7 8 9 Hours Per Start Life Table using program start and instant start ballasts.