ABB Technology Day, Cape Town, May 21st & 22nd ABB UPS Pioneers of True Modular & Transformerless UPS

Similar documents
Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

ABB UPS 3. November 2014

Est FlexiPower Mini UPS FPX Mini kVA

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Product catalog. ABB UPS products and solutions Power protection for critical infrastructures

PowerWave 33 Efficient power protection for today s IT and process-related work environments

DPA UPScale RI kw The modular UPS for customized solutions

Modular three-phase UPS system. DPA UPScale RI kw The modular UPS for customized solutions

ABB UPS products and solutions Power protection for critical infrastructures

Power Protection Discrete Automation & Motion South Africa

ABB UPS products and solutions Power protection for critical infrastructures

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Industrial PFC UPS System

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Food power. ABB s rugged UPS PowerLine DPA ensures food and beverage production facilities keep running

Features and Benefits

PowerWave 33, kw

PowerValue 11/31 T kva

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

D Series: UPS UPTO - 300KVA - Three / Three Phase

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Onfiniti. 1 Phase UPS

TECHNICAL DATA SHEET KVA UPS Systemss

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

PowerScale kva Technical Specifications

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ABB Data Center Solutions Day 5 July 2013 by Kelvin Sim Myths or Truths: Achieving 99% Efficiency with Single Conversion Backup Power System

MKN-DSP SERIES - THREE PHASE

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

UPS Multi Power 1-28 x 42 kw up to 1MW

Three Phase UPS Systems Range: 10 to 500kVA

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Liebert. FP 50Z kva

PowerScale TECHNICAL SPECIFICATIONS

TLE Series UPS 400/500 kw With eboost Technology

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

UPS5000-E (25-75 kva) Series

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

60 to 160 kva.

Power+ CLASSIC. 20/30 kva, 3x208 Vac

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

ConceptpowerTM Modular kVA

TLE Series UPS 160/200/225/250 kw with eboost Technology

Features and Benefits

Technical Data Sheets

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

PowerWave kva

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Phase Modular Finally the benefits of Modular ups are for all

Three Phase UPS Systems

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

PowerValue TM. Compact protection for power supply For Continous Power Protection Availability

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

Master MPS kva kva 3:1 3:3 VFI TYPE

3ph UPS NS3000 series kVA

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

MGE TM Galaxy TM 7000

Technical Data Sheets

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

On-line, Single Phase, Double Conversion UPS

1.1 GENERAL CHARACTERISTICS

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Power Conditioning Oil and Gas Applications

Keor MOD THREE-PHASE MODULAR UPS. up to 250 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL INFRASTRUCTURES

UPS SYSTEMS PDUs SURGE PROTECTORS POWER INVERTERS DATACENTER UPS. Product Catalog

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

MGE Galaxy 5500 Marine

Master MPS kva kva 3:1 3:3 VFI TYPE

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

» Sophisticated» Reliable» Intelligent

Modular UPS «AGIL» Stay on! Changing the rules for critical business continuity :

EFFEKTA Power Supplies

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Master Plus kva

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

ABB solar inverters Product portfolio

MGE TM Galaxy TM 7000 GFC

Transcription:

ABB Technology Day, Cape Town, May 21st & 22nd 2014 ABB UPS Pioneers of True Modular & Transformerless UPS

Milestones 1993 2012 From Newave to ABB 2012 march Newave becomes part of ABB April 2014 Slide 2

ABB Ups Operations Today Full Surface: 12 000 m2 Production Area: 7 800 m2 Production Capacity:12 000 3 Phase UPS / Year Expansion Capability : 7 800 m2 April 2014 Slide 3

Business Unit Power Electronics UPS as a new product group Power Electronics Wind & Solar Traction Converters EV Charging (Epyon) Power Protection Advanced power electronics Converter products Excitation systems High power rectifiers Power quality products Service Solar Inveters Wind Tower generators Control Systems Mass Transit and Auxiliary Converters Propulsion Converters Auxiliary Power Converters Battery Chargers High Power Propulsion for Locomotives and High-Speed Trains DC Fast Chargers and Systems AC Chargers (Systems) Service On-line UPS systems 1-phase 1.0-20kVA 3-phase 7.5-5000kVA Industrial UPS Systems Services Service Service April 2014 Slide 4

Our Group Newave SA Switzerland Product Group HQ ABB UPS Companies Quartino Marketing R&D Engineering Production Administration Quality, Safety Sales (Partners) Europe (35) Africa ( 6 ) M.East (12) Asia (9) Oceania (3) Latin America (13) N. America (1) Switzerland Germany Netherland Spain Finland Austria Italy India China Brazil Mexico April 2014 Slide 5

Academy The Newave Academy s primary purpose is to develop excellence by consistently training sales and service teams. Our dedicated instructors teach basic and advanced competences (courses on all important topics) which allow sales and service professionals to make the right decisions, propose the right solutions and ensure excellent quality of service regardless of the application. The Newave Academy offers training courses on all aspects of the sales, service and system engineering to guarantee the availability of installed Newave UPS systems, the protection of critical loads and the safety of service engineers. April 2014 Slide 6

Power Protection Product range Commercial Industrial Double Conversion Standalone UPS Double Conversion Modular UPS Static Switch and Power Distribution Double Conversion Industrial UPS & Chargers Single Conversion UPS Power Conditioning PowerValue DPA Upscale Superswitch Cyberwave PCS100 AVC Product PowerScale Conceptpower DPA Cyberex ZF RBE II PCS100 UPS-I PCS100 RPC PowerWave 33 DPA 500 PDUs, FaultGuard PCS100 SFC I.T Computer Rooms Major Market Segments Data Centers Health Finance Telecom Data Center Finance Health Infrastructure Data Center General Industry Process Automation Oil & Gas Power Generation Water Processing Data Center General Industry Process Automation Water Processing General Industry Process Automation Water Processing Food & Beverage Infrastructure Telecom Aluminium Plants Food & Beverage Military Industry Security Pictures Power Range 1 kva to 500 kw Parallel to 5 MW 10 kw to 500 kw Parallel to 3 MW Up to 4000A STS, 600 KW PDM Up to 150kVA 150 kva to 3 MVA (parallel) 125 kva 20 MVA (parallel) Compliancy IEC IEC UL - IEC UL - IEC IEC - UL IEC - UL UPS (CH - Quartino) Power Solutions (US - Richmond) Power Conditioning (NZ - Napier)

Creating Trends Trend N 1* Transformerless UPS Trend N 2** Modularity For the first time in the threephase UPS market, revenues for transformerless three-phase UPS were greater than those for transformer-based three-phase in 2008. This shift in product topology was decisive, and is anticipated to continue to grow in coming years as the efficiency, size and manufacturing cost benefits of transformerless technology win over customers... The financial crisis has given IT executives who are willing to make tough decisions a platform to significantly rationalize their data centre and IT infrastructure, and cut up to 50% of current costs, which they can potentially leverage into new investments to make their organization more efficient or competitive. *Source: IMS Research June 2010 ** Source: Steve Sams, VP Global Site and Facilities, IBM Steve Sams, VP Global Site and Facilities, IBM April 2014 Slide 8

ABB UPS Concepts Transformer UPS Design Maintenance Bypass Line 1 Bypass Line 2 ~ = Rectifier = ~ 400 Vac 340 Vdc 200 Vac 400 Vac Inverter Output Transformer (1:2) Load Battery April 2014 Slide 9

ABB UPS Concepts Transformerless UPS Design Maintenance Bypass Line 1 Line 2 ~ = Rectifier = Bypass = ~ 400 Vac 340 Vdc 700 Vdc 400 Vac = Booster = = Inverter Battery Charger Load Battery Variation in number of blocks (40-50) allowed in order to adjust autonomy times Separate battery chargers provide improved rippleless charging April 2014 Slide 10

ABB UPS Concepts Transformerless UPS Design Efficiency (%) 97 96 95 94 93 92 91 90 89 88 Transformer vs. Transformeless Transformerless Transformer based 25% 50% 75% 100% Load (%) April 2014 Slide 11 20 settembre 2012

ABB UPS Concepts Transformerless UPS Design No transformer = Less noises, less filters, less hardware, smaller size = Less Cooling, higher efficiency, lower weight, less space Efficiency > 95% - no or little additional cooling necessary Small physical size; Light weight: 500 kva = 1000 kg Small footprint no additional cabinet for 12 pulse or battery cabinet needed Variation of number of battery blocks allowed Separate battery charger ensures correct ripple free Input current distortion < 3% - no additional input filters High input power factor (0.99) April 2014 Slide 12

ABB UPS Concepts Modularity MAINS 1 MAINS 2 CRITICAL LOAD April 2014 Slide 13

ABB UPS Concepts True Modularity MAINS 1 MAINS 2 DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA STATIC BP SWITCH DPA BATTERY PACKS DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA STATIC BP SWITCH DPA BATTERY PACKS DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA STATIC BP SWITCH DPA BATTERY PACKS CRITICAL LOAD April 2014 Slide 14 Each Module is a complete UPS!

Contents Company Profile UPS Design Evolution Modular System Design Parallel Architectures Value Proposition Product line April 2014 Slide 15

Modular Technology What is your definition of Modular? April 2014 Slide 16

Modular Architectures Parallel System Architectures are designed to increase Power Protection Availability, which cannot be achieved by single UPS s. Parallel Architectures available today: Central Parallel Architecture (CPA) Decentralized Parallel Architecture (DPA) TM These 2 architectures differ by the level of decentralization of their building blocks April 2014 Slide 17

Modular Architectures Centralized Parallel Architecture (CPA) In a Centralized Parallel Architectures the system is composed of common system building blocks: MAINS 1 MAINS 2 CENTRAL PROCESSING UNIT CENTRAL CONTROL PANNEL CPU Control Panel Static Bypass Switch Battery Redundant POWER UNIT Redundant POWER UNIT CENTRAL BATTERY PACKS The only Decentralized Parts are the Power Units. Redundant POWER UNIT CRITICAL LOAD CENTRAL STATIC BP SWITCH April 2014 Slide 18

ABB UPS Concepts True Modularity Decentralized Parallel Architecture (DPA) TM distributes the entire UPS Hardware and Software into each module. MAINS 1 MAINS 2 DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA STATIC BP SWITCH DPA BATTERY PACKS A DPA systems includes distributed/decentralized: CPU; Control Panel; Static Bypass Switch; Power Unit and Separate Battery DPA CONTROL PANNEL DPA CONTROL PANNEL DPA CENTRAL PROCESSING UNIT DPA CENTRAL PROCESSING UNIT DPA POWER UNIT DPA POWER UNIT DPA STATIC BP SWITCH DPA STATIC BP SWITCH DPA BATTERY PACKS DPA BATTERY PACKS CRITICAL LOAD April 2014 Slide 19

Modular Technology April 2014 Slide 20

Modular Technology Added Value Safe Swap Easy maintenance (MTTR) No risks for the load No dangers for the technician Increase number of modules with no supply interruptions April 2014 Slide 21 20 settembre 2012 Newave Energy AG 21

Newave UPS Concepts DPA - Decentralized Parallel Architecture True system redundancy No single point of failure (increased availability) Enhanced serviceability High level of flexibility Reduced Total Cost of Ownership (TCO) Low weight of modules Low footprint Multi Master-Slave Technology through a simplified BUS Communication Back Feed protection integrated Safe swap April 2014 Slide 22

Contents Company Profile UPS Design Evolution Modular System Design Parallel Architectures Value Proposition Product line April 2014 Slide 23

Our Value 1) High Availability Highest classification (IEC 62040-3 class: VFI-SS-111) UPS topology: double-conversion designed to handle all types of power failures Latest IGBT technology with DSP controls High MTBF Parallel redundant configurations with Distributed Parallel Architecture (DPA) Very High MTBF Fast and efficient repair due to modularity with safe swap feature Low MTTR 2) Low TCO Low initial investment, top of the line performance allows smaller upstream sizing, less cooling capacity, smallest foot print Low operating costs, efficiency in double conversion mode 96%, in ECO mode >99%, savings in electricity costs, less cooling costs Modularity allow for cost efficient scalability and concurrent maintenance 3) Sustainability and green values Efficiency lower carbon emissions Green (energy saving) manufacturing, recycling, (ISO 14001) low carbon footprint, no waste/pollution Swiss quality long life cycle with minimum waste Low size and weight savings in footprint April 2014 Slide 24

Our Value Meeting customers needs Minimize interruptions (Availability) Respect requirements of an enterprise in expansion (Flexibility) Continuous growth of energy consumption lowering the costs (Efficiency) Reliability respecting the performance (Service) April 2014 Slide 25 20 settembre 2012

Availability Redundancy How to increase mains availability UPS Single UPS configuration MTBF = 50 000 to 200 000 hrs Years = 6 to 23 UPS UPS Parallel redundant configuration (N+1 redundancy degree) MTBF = 150 000 to 500 000 hrs Years = 17 to 57 April 2014 Slide 26

Availability Modularity UPS UPS AAAAAAAAAAAA = MMMM UUU MMMM UUU + MMTT UUU Non Modular (1+1) Redundant Configuration MTBF 600 000 500 000 MTTR 6h 0.5h Modular (3+1) Redundant Configuration Availability 0,999990 (5 nines) 0,9999990 (6 nines) April 2014 Slide 27

Availability New service concept UPS UPS Standalone Spares Kit 1 Hr,2Hr, 3Hr? Modular Spare Module 15-30 minutes April 2014 Slide 28

Contents Company Profile UPS Design Evolution Modular System Design Parallel Architectures Value Proposition Product line April 2014 Slide 29

The Product Line Contents Newave product strategy Rack-mountable Modular UPS Standalone UPS Connectivity & Management Systems Common Features & Benefits April 2014 Slide 30

Product Development Strategy Newave Products are developed around 5 main criteria High availability and reduced downtime / MTTR Flexibility and Scalability pay as you grow Highest efficiency at operating conditions (50% - 75% load) lowest TCO Minimal space requirements Compact design Reduced environmental impact April 2014 Slide 31

The Product Line Contents Newave product strategy Rack-mountable Modular UPS Standalone UPS Connectivity & Management Systems Common Features & Benefits April 2014 Slide 32

Rack-mountable Modular UPS Conceptpower DPA Conceptpower DPA Upgrade 250 DPA UPScale DPA UPScale ST DPA UPScale RI 10kVA 1.5 MVA up to 30 Modules ST 10 200 kw up to 10 Modules RI 10-80 kw up to 4 Modules April 2014 Slide 33

Conceptpower DPA April 2014 Slide 34 Technical Specifications Cabinet Type Power Range Individual power range per module Maximum power per frame Maximum power (n+1 Redundancy) Parallelable up to Rated output voltages Safe-Swap modular / rack 30kVA 1.5MVA 24/32/40kW 50/150/250kVA 1200kW Input current distortion THDI <3% Input power factor (PF) 0.99 Output power factory 0.8 Classification acc. IEC/EN 62040-3 Working mode 30 Modules 380/220;400/230,415/240V three phase VFI-SS-111 Efficiency up to 95.5% Power density per m² Maximal weight w/out batteries Battery compartment Maintenance bypass Scalability (n+1) capable on-line double conversion up to 342kW/m² from 224kg up to 490kg Internal or external matching cabinets standard Yes (horizontal + vertical)

Conceptpower DPA Modularity Design 100% continuous duty static switch Control Logic Redundant Power supplies Power Board Integration power components High Frequency IGBT/PWM Inverter April 2014 Slide 35

Conceptpower DPA Power Range 30 1500 kva Safe-Swap DPA Models CLASSIC FRAME 50kVA TRIPLE FRAME 150kVA UPGRADE FRAME 250kVA Wide DPA-Module 24kW/30kVA 32kW/40kVA 40kW/50kVA 663x225x720 730x800x1650 7x40 x 7/9Ah Total 280 Blocks 730x800x1975 3x2x40x7/9Ah Total 240 blocks 730x800x1975 External battery Only 44 up to 56 kg April 2014 Slide 36

DPA UPScale ST Technical Specifications April 2014 Slide 37 Cabinet Type Safe-Swap modular (rack) Working mode on-line double conversion Output power factory 1.0 Individual power range per module 10/20kW Maximum power per frame 40/60/80/120/200kW System Power Range 10-200kVA Parallelable up to 10 Modules in the same frame Maximum power (n+1 Redundancy) 180kW Efficiency up to 95.5% Parallelable up to 10 Modules Maximal weight w/out batteries from 115kg up to 263kg Module weight 21.5kg (20kW) Rated output voltages 380/220;400/230,415/240V three phase Input current distortion THDI <3% Input power factor (PF) 0.99 Classification acc. IEC/EN 62040-3 VFI-SS-111 Power density per m² up to 472kW/m² Battery compartment internal or external matching cabinets Maintenance bypass standard in each modules

DPA UPScaleTM Power Range 10-120 kw UPScale ST 60 UPScale ST200 19 UPScale Modules : UPScale M10 UPScale M20 10kW / 10kVA UPScale ST 40 UPScale ST 80 20kW / 20kVA HU = 3 WxHxD 488x132x488 18.3 kg and 21.5 kg WxHxD 550x1135x767 WxHxD 550x1975x757 WxHxD 550x1135x767 WxHxD 550x1975x767 2 x 40 x 7.2/9Ah Total 80 blocks April 2014 Slide 38 3 x (2x40) x 7.2/9Ah Total 240 blocks External Batt. ONLY External Batt. ONLY

DPA UPScale RI Technical Specifications April 2014 Slide 39 Enclosure Type 19 rack-mountable Working mode on-line double conversion Output power factory 1.0 Individual power range per module 10/20kW Maximum power per frame 20/40/80kW System Power Range 10kW 80kW Maximum power (n+1 Redundancy) 60kW Efficiency up to 95.5% Parallelable up to 4 Modules (single frame) Maximal weight w/out batteries from 59kg up to 136kg Module weight 21.5kg (20kW) Rated output voltages 380/220;400/230,415/240V three phase Input current distortion THDI <3% Input power factor (PF) 0.99 Classification acc. IEC/EN 62040-3 VFI-SS-111 Power density per m² up to 122kW/m² Battery compartment Internal or external Maintenance bypass standard

DPA UPScale RI 10-80 kw Rack-Independent Models UPScale RI 12 19 UPScale Modules : UPScale M10 UPScale M20 UPScale RI 11 10kW / 10kVA 20kW / 20kVA UPScale RI 10 WxHxD 488x132x488 18.3 kg and 21.5 kg WxHxD 488x487x732 (11Hu) No internal Batteries WxHxD 488x487x732 (11Hu) 1 x 40 x 7.2/9Ah Total 40 blocks WxHxD 488x665x732 (15HU) 2x40 x 7.2/9Ah Total 80 blocks April 2014 Slide 40

DPA UPScale RI 10-80 kw Rack-Independent Models UPScale RI 24 UPScale RI 22 UPScale RI 40 UPScale RI 20 10kW / 10kVA 20kW / 20kVA HU = 3 WxHxD 488x132x488 18.3 kg and 21.5 kg WxHxD 488x665x732 (15HU) No internal Battery April 2014 Slide 41 WxHxD 488x798x732 (18HU) 2x40 x 7.2/9Ah Total 80 blocks WxHxD 488x1153x732 (26HU) 4x40 x 7.2/9Ah Total 160 blocks WxHxD 488x798x732 (18HU) No internal Battery

Conceptpower DPA 500 Best-in-class modular UPS

Conceptpower DPA 500 True modularity with fault tolerant DPA architecture 100 kw rated power module Each module can operate fully independently, thanks to ABB s Decentralized Paralleling Architecture (DPA) 5 modules in a single DPA 500 frame Amazing 500kW secured power in only 1.5 m² All modules are fully redundant with each other DPA 500 frame completes the system: Bypass input breaker, battery fuse and output isolation switch for each module, dedicated. System maintenance bypass switch included System cabling supports both, single and dual input feed Battery can be managed as separate for each module or as common to system April 2014

Conceptpower DPA 500 Ultimate scalability 6 frames can be further connected in parallel to achieve amazing 3 MW system total power Multiple benefits follow from the advanced scalability: Adding capacity to system is easy Adding redundancy to increase availability and reliability becomes easy Standardizing UPS system to serve load segments of different sizes is reality April 2014

Conceptpower DPA 500 Highest availability lowest cost of ownership Highest availability Zero down time True redundancy with fault tolerant DPA architecture Fast and easy maintenance without downtime with On-line swappable modules True scalability; flexible power upgrades and downgrades Modular architecture: Minimized initial investment Pay as you grow Compact size and small footprint Reduced electricity consumption with high double conversion efficiency, 96% (Eco-Mode >99%) Concurrent, easy and fast maintenance Lowest total cost of ownership (TCO) April 2014

Conceptpower DPA 500 Highlights Serviceability: Online Swap Modularity (OSM) Online serviceability Top or bottom cable entry (standard) Human Machine Interface Graphical display on system level DPA displays in each module April 2014

Conceptpower DPA 500 Scalability example 3000kW + 3000kW system April 2014

Conceptpower DPA 500 Standardization of power protection Modular scalability enables the users with various types and sizes of data centers to: Optimize the solution according to the needs of each data center or each load segment Gain savings due to simple and standardized power protection concept - And service concept All this at the same time!! April 2014

The Product Line Contents Newave product strategy Rack-mountable Modular UPS Standalone UPS Connectivity & Management Systems Common Features & Benefits April 2014 Slide 49

Standalone UPS PowerScale Powerwave 33 10kVA 1MVA (up to 20 units in parallel) 10/15/20/25/30/40/50kVA 60kW 5MW (up to 10 units in parallel) 60/80/100kW 120/160/200kW 250/300kW 400/500kW April 2014 Slide 50

PowerScale Technical Specifications Cabinet Type Stand Alone Working mode on-line double conversion Power Range 10/15/20/25/30/49/50 kva Output power factor (PF) 0.9 Efficiency up to 95.5% Parallelable up to 20 Systems Maximum power (n+1 Redundancy) 1.0 MVA Scalable (n+1) capable Yes (horizontal) Rated output voltages 380/220;400/230,415/240V three phase Input current distortion THDI <3,0% Input power factor (PF) 0.99 Classification acc.iec/en 62040-3 VFI-SS-111 Power density per m² 33 up to 112 kw/m² Maximal weight w/out batteries from 60kg up to 155kg Battery compartment Internal or external Maintenance bypass standard April 2014 Slide 51

PowerScale Internal Batteries Type A Type B Type C 10kVA/9kW 15kVA/13.5kW max. 15 min max. 10 min. 10kVA/9kW 15kVA/13.5kW max. 35 min max. 20 min. Battery configuration Max. 3 x48 x 9Ah Or 20kVA/18kW max. 6 min. 20kVA/18kW max. 15 min. Max. 1x48 x 28Ah 25kVA/22.5kW max. 8 min. 25kVA/22.5kW max. 18 min Battery configuration Max. 1 x48 x 9Ah Battery configuration Max. 2 x48 x 9Ah 30kVA/27kW 40kVA/36kW max. 13 min. max. 10 min. 50kVA/45kW max. 8 min. 345 x 720 x 710 345 x 1045 x 710 440 x 1400 x 910 60-62-64kg 88-90-92-94kg 135-145-150-155kg April 2014 Slide 52

Powerwave 33 Technical Specifications Cabinet Type Working mode Power Range Output power factor (PF) 1.0 Stand-alone Efficiency up to 96% Parallelable up to Maximum power (n+1 Redundancy) Scalable (n+1) capable Rated output voltages on-line double conversion 60/80/100/120/160/200/250/300/400/500 kw 10 Systems 5,0MVA Input current distortion THDI <3,5% Input power factor (PF) 0.99 Classification acc.iec/en 62040-3 Power density per m² Maximal weight w/out batteries Battery compartment Maintenance bypass Yes (horizontal) 380/220;400/230,415/240V three phase VFI-SS-111 up to 363kW/m² from 230kg up to 1000kg Battery enclosures (60-100kW) and matching external battery cabinets standard April 2014 Slide 53

The full range Technology: On-Line, transformer less Power range: 60 500 kva/kw (3/3) Rated at PF = 1.0 60-80-100kW 120-160-200kW 250-300kW 400-500 kw April 2014 Slide 54

The compactness of PowerWave 33 60-80-100 kw 550 x 1820 x 750 mm From 230 to 245kg FEATURES Compact size Low weight Front access only 60-80-100 kva with BAT-ENC A 970 x 1820 x 750 mm From 250 to 285 kg (w/o batt.) BENEFITS Space costs savings 60-80-100 kva with BAT-ENC B 1180 x 1820 x 750 mm From 270 to 305 kg (w/o batt.) Less transportation costs and no need to reinforce the floor basement April 2014 Slide 55

The compactness of Powerwave 33 120-160-200 kw 850 x 1820 x 750 mm From 280 to 310 kg FEATURES Compact size Low weight Front access only 250-300 kw 1100 x 1920 x 750 mm From 390 to 410 kg No rear access needed 400-500kVA can be placed against the wall BENEFITS Space costs savings 400-500 kw 1650 x 1994 x 850 mm From 950 to 1000 kg Less transportation costs and no need to reinforce the floor basement April 2014 Slide 56

Options - Powerwave 33 Top Cable Entry Back feed protection Parallel-Kit (adapter + cable with various lengths) Synchronization-Kit (when using STS) Connectivity (SNMP, Multidrop, environ. sensors etc.) Elevation-Kit Manual Bypass (only for 400-500kW, on all others it is standard) April 2014 Slide 57

Powerwave 33 - Parallelability Up to 10 units / up to 5MW G G To the Load April 2014 Slide 58

The Product Line Contents Newave product strategy Rack-mountable Modular UPS Standalone UPS Connectivity & Management Systems Common Features & Benefits April 2014 Slide 59

Management and Connectivity Monitoring UPS systems Extensive alarm/events management Continuous information for service activities Support functionalities for Building Management Systems Safe shutdown of critical loads Remotely shutdown units when strictly necessary April 2014 Slide 60

Management and Connectivity For monitoring and executing safe shutdowns, the UPS and the control system communicate through : Interface that is built into the UPS; Newave s optional products Communication HW Software November 20, 2012 Slide 61

Products In-built interfaces Eg. Powerwave 33 USB RS232 Same functionalities X1 Inputs X2 Outputs / Dry contacts Multidrop cable Parallel cable SNMP Card Modem Card Interchangeable April 2014 Slide 62

Monitoring Products Communication HW Network Interface cards Environmental sensors HW that integrates data from the UPS into the management system Data logging Alarming (email, sms, traps) Aux I/O management Web server UPS shutdown Highly programmable and stable Software SW for the cards above (Wavemon) Enables shutdown of the servers and remote scripting April 2014 Slide 63

The Product Line Contents Newave product strategy Rack-mountable Modular UPS Standalone UPS Connectivity & Management Systems Common Features & Benefits April 2014 Slide 64

Industrial Products

Key Market Segments Key Industrial Market Applications Oil & Gas (platform or refinery) Petro-chemical & Chemical Power Generation Utility Power plants Sub-station etc Pulp & Paper Metal & Mining Food & Beverages Transportation

Industrial Definition external components DPA Module Dust Filter IP54 Ventilation Fan 1. Upgradable for rack mount cubicles protection (IP protection with IP54 and IP42 (RITTAL) 2. High compact and rigid cubicle with dust filter 3. Good ventilation circulation 4. Suitable for couple with input isolation transformer, bypass transformer or output transformer, depend on load application 5. Integration timer control or tripping breaker with distribution board 6. Interface with various type of DCS alarm signaling board, MODBUS, remote communication 67 IP54 / IP42 Cubicle Robust Design

Industrial Definition internal components Integration Power Pack ESIS DPA Module Urethane conformal PCB Coating High Quality Components Swiss QTY Flammable retardant cables 1. High quality semi conductor, compact, robust and rigid integration board. 2. Urethane/Silicone conformal PCB Coating A durable protection coating for printed circuit boards. Provides protection against offshore fungus, moisture, sandy, corrosion, thermal shock and chemical environments 3. Flammable retardant cables or halogen free wiring 4. Integration power pack for power components and control 68

Industrial Design Architecture of DPA Module DPA 3 x 40kVA Module Two (2) Empty Slots For Power Upgrade Demands Charger 15A per Module Inner charger 3x15A = 45A max Two level charging (Float/Fast) Two charging BAT & INV current Sealed Lead 450AH Load 80kVA DPA 80kVA + 40kVA N (80KVA) + 1 (40kVA) Paralleling with up to 4 cabinets 20 Modules Power Upgrade Demands NiCad 450AH 69

Industrial Design Architecture of DPA Module DPA 5 x 40kVA Module Charger Module Cabine Batt Charger 35A Module Charger 15A per Module Inner charger 5x15A = 75A max Two level charging (Float/Fast) Two charging BAT & INV current Ext charger 3x35A = 105A max NiCad 1, 500AH` Sealed Lead 750AH Load 160kVA DPA 160kVA + 40kVA N (160KVA)+ 1 (40kVA) NiCad 750AH NiCad 10%CH= 150A 70

Commercial bespoke UPS for use in Industrial & Semi Industrial Environments DPA Module Dust Filter IP54 Ventilation Fan IP54 / IP42 Cubicle Robust Design 1. Upgradable for rack mount cubicles protection (IP protection with IP54 and IP42 (RITTAL) 2. Highly compact and strong cubicle with dust filter 3. Enhanced Ventilation 4. Package with with Input isolation transformer, Bypass transformer or Output transformer, depend on load applications in Matching Cubicles

Overview of Power Solutions Business Power Protection solutions provider to datacenter and industrial markets sold under Cyberex brand name. In business since 1968, acquired by ABB in 2012 Moved to Power Protection product group in 2014 Headquarters: Richmond, Virginia 100,000sqft of Manufacturing and Offices 410 Employees, all in US 2013 Global Revenue of $100M Design / Manufacture / Service : Datacenter - Static Transfer Switches (STS) - Power Distribution Modules (PDM) - Remote Power Panels (RPP) - Branch Circuit Monitoring (BCM) Generators, Battery Maintenance For more information go to: www.tnbpowersolutions.com Industrial - Dual Conversion UPS - DC Chargers and Inverter with Static Switch (ISS) ABB Month DD, YYYY Slide 72

Industrial UPS 20 Year Design Life Fully rated STS Technology Full Isolation Transformers Input and output High fault clearing capability Interactive Monitoring, Diagnostics & Controls Color Touch-Screen LCD Interface Microprocessor Supervisor DSP Feedback Controls (digital signal processor) Fiber Optic Data Path Available Range: 10 80 kva, 1-Ph output Configurable Input & Output Voltage Remote monitoring SNMP or Modbus

Industrial Portfolio UL / IEC Series 10-80kVA Single Phase Output for Industrial Installations C2400 9-24kVA Split Phase Output for Retail & Commercial Installations 100 A Single Ph / 1000A Three Ph Battery Chargers UL 10-80kVA Inverter Static Switch IEC/UL IEC/UL

Industrial UPS MAJOR COMPONENTS Output Transformer Input Transformer Rectifier /Charger Inverter Fully Rated Static Switch Mains Input Battery Bypass Input Maintenance Bypass Switch

Battery Chargers Battery Chargers (single and three phase AC input) Input: 120V-600V, 50-60Hz Configurable Output: Voltage: 12, 24, 48 or 130 VDC Current: to 100A (1-Ph); to 1000A (3-ph) Wall, rack or floor mounted Battery Temperature Compensation Voltage ripple filter Fuse or breaker protection AC surge suppression integrated Parallel (load-sharing) option Cyberex Rectifier/Battery Eliminator is ideal where AC to DC conversion is required. Such applications include: Battery Charging Power DC Switchgear Opening Breakers Closing Relays Initiating Emergency Power Transfers

PCS100 Power Conversion

DMPC Power Protection LV PCS Product and Channel Positioning PCS100 AVC & UPS-I PCS100 RPC PCS100 SFC Highly Critical Load Application Industrial load applications Grid interconnection Applications Semiconductor Factories Electronic Manufacturing Chemical & Pharmaceuticals Laser and CNC machines Plastic extrusion processes Automotive Space & Aviation manufacturing Oil & Gas industry Food & Beverage Textile Cranes Welders Unbalanced loads Saws & Presses Heavy motor loads Machine manufacturing Oil & Gas industry Mining industry Ports Shipyards Navy & Marine vessels Oil & Gas industry

DMPC Power Protection LV PCS Product positioning Product Type PCS100 AVC PCS100 UPS-I PCS100 RPC Load Applications Highly critical load applications Semiconductor Fabs, Electronic Manufacturing, Chemical & Pharmaceuticals, Laser and CNC machines, Plastic extrusion processes, Automotive, Space & Aviation manufacturing, Oil & Gas industry, Food & Beverage, Textile, Data center & IT Applications Industrial load applications Cranes, Welders, Unbalanced loads, Saws, Presses, Heavy motor loads, Automotive, Oil & Gas industry, Mining PCS100 SFC Grid interconnection segment Ports - Shipyards - Oil & Gas Industry - Navy & Marine vessels April ABB 2014 Group

New Product Coming Soon! MV UPS-I

PCS100 MV UPS Introduction Development project Kereru is currently underway to develop a range of 6.6kV MV UPS products up to 6 MVA After this development we will increase the voltage range to 11 kv and 13.2 kv. Dates TBD. 6.6kV Currently in design and prototyping stage where technical specifications are being finalized. The information in this presentation is still preliminary but can be used for discussion with customers.

PCS100 MV UPS Introduction Voltage 15kV 6.6kV PCS100 MV UPS 480V 400V PCS100 UPS-I Newave 220V 1MVA 3MVA 6MVA Power

PCS100 MV UPS Product Overview Why Medium Voltage? Complete plant protection for large critical manufacturing processes Retrofit possibilities Large Datacenters with power protection at MV and MV distribution Why build upon the UPS-I Single conversion topology is a natural choice for MV. Power electronics and energy storage can remain at LV, with transformer coupling to MV. MV LV May 27, 2014 Slide 83

PCS100 MV UPS Product Details Ratings 2MVA 4MVA 6MVA Nominal Voltage (kv) Application range 4.16kV to 6.6kV 6.6 6.6 6.6 UD current rating (A) 600 600 600 Efficiency > 99.5 % > 99.5 % > 99.5 % Dimensions H,W,D (m) Autonomy (ultracapacitors) Autonomy (batteries) Coupling transformer qty 2.2 x 6.0 x 2.0 Not including storage 2.2 x 9.6 x 2.0 Not including storage 2.2 x 13.2 x 2.0 Not including storage 2-3 sec 2-3 sec 2-3 sec Up to 15min Up to 15min Up to 15min 1 2 3

PCS100 MV UPS SLD 6MVA

PCS100 MV UPS Energy Storage Options Technology Features Ultracapacitors Exceptional cycle life (>500,000) 15 yr life Very compact, 600 kw per 0.64m 2 High Discharge Sealed Pb Acid Cost effective 30-60 sec solution 10 yr design life Lithium Ion Higher cycle life than PB (>3000 typ) 20 yr design life at 35 o C Higher energy density than Pb Flywheel Very high cycle life Long life with maintenance A no lead / no chemical solution

Quality & Recognitions April 2014 Slide 87