Gas-actuated thermometer Model 73, stainless steel version

Similar documents
Gas Actuated Thermometers Stainless Steel Series, Model 73

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Bimetal Thermometers Process Industry Series, Model 55

Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Bimetal thermometer Model 52, industrial series

Bimetal thermometer Model 52, industrial series

Bimetal Thermometers Model 54, Heavy Duty Series

Bourdon tube pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21PB, NS 60, 80 and 100

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Duplex pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21DPB, NS 60, 80, 100 and 130

Resistance thermometer with digital indicator Model TR75, battery operation

Resistance thermometer with digital display Model TR75, battery operation

Machine glass thermometers Model 32, V-Form

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Bourdon tube pressure gauge with switch contacts Models PGS21.1x0, industrial series

Bourdon tube pressure gauges with switch contacts Models PGS23.1x0, stainless steel version

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Resistance thermometer Model TR10-E, for additional thermowell

Pressure gauge per EN with mounted diaphragm seal With threaded connection, threaded design Model DSS10M

Mini temperature switch Stainless steel switch enclosure Model TXS

Bourdon Tube Pressure Gauges with Switch Contacts Models /160, Stainless Steel Version Models /160, Stainless Steel Safety Version

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Resistance thermometer Model TR10-B, for additional thermowell

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

Bourdon tube pressure gauge, copper alloy Panel mounting series Models and

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

Compact temperature switch Model TCS

Accessories for diaphragm seals Block flange and saddle flange Models , ,

Thermocouples Model TC10-B, for Additional Thermowell

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Differential pressure gauge Model , copper alloy Model , stainless steel version

Differential pressure switch Model DPS40

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Mechatronic pressure measurement. Applications. Special features. Description

Diaphragm seal with threaded connection Plastic version Model

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Cable resistance thermometer Model TR40

Thermocouples Model TC10-E, for Additional Thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Connection parts with nominal width DN 6 Valves, coupling valves, protection caps, fittings, adapters and connections for analytic instruments

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Compact differential pressure switch Models DC, DCC

Thermocouple Model TC10-E, for additional thermowell

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Diaphragm seal with flange connection For the pulp and paper industry Model

Dial thermometers. Gas filled system and Bi-metal. dial thermometers

Reed sensor For bypass level indicators Model BLR

Connecting parts with nominal width DN 20 Valves, coupling valves, protection caps, fittings, adapters and connections for analytic instruments

Surface thermocouple Model TC50

Pressure gauge in stainless steel version. Suitable for aggressive media and environments. Aluminium, white with black lettering

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

Pressure gauge per EN with mounted diaphragm seal With clamp connection Model DSS22F

Cable thermocouple Model TC40

Thermocouple Model TC10-H without thermowell

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Float switch For horizontal installation, miniature design Model HLS-M

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Cable resistance thermometer Model TR40

NEUMO BioControl Model

Cable thermocouple Model TC40

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Mini pressure switch Stainless steel switch enclosure Model PXS

Compact pressure switch Model PCS

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Differential pressure gauge with electrical output signal Model A2G-15

Pressure gauge in hygienic design with mounted diaphragm seal With clamp connection Model DSS22P

Remote reading dial thermometers, version for industry

For the plastics machinery industry Manifold thermocouple Model TC47-MT

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Valve manifold for differential pressure measuring instruments 3-, 5-valve manifold Models IV30, IV31, IV50 and IV51

High-quality pressure sensor with mounted diaphragm seal With threaded connection, welded design Model DSS34T

Diaphragm seal with sterile connection For homogeniser machines Model

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Thermowell For sanitary applications Model TW61, for orbital welding

Measuring probe For ventilation and air-conditioning Model A2G-FM

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

High-quality pressure sensor with mounted diaphragm seal With flange connection, flush diaphragm Model DSS27T

Duct thermometer Model TF40

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Tubeskin thermocouple assembly Model TC59-V

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

Pressure switch, high adjustability of switch differential

Thermocouple with spring-loaded tip Model TC55

Cable resistance thermometer Model TR40

Tubeskin thermocouple assembly Model TC59-W

Transcription:

www.materm.si tel: 02 608 90 10 Mechanical temperature measurement Gas-actuated thermometer Model 73, stainless steel version WIKA data sheet TM 73.01 Applications For aggressive media in the chemical, petrochemical and process engineering industries Universally suitable for machine building, plant, vessel, apparatus construction and food industry Temperature measurement without any contact to the medium Mounting in instrument boards, control cabinets, control panels Special features Instruments meet the highest standards of measurement technology Case and stem from stainless steel For external mounting on pipes and tanks Various connection and case mounting designs Versions also available with adjustable stem and dial, with capillary, with contact bulb or edgewise panel design (square) Gas-actuated thermometer Fig. left: lower mount (LM), model R73.100 Fig. centre: with capillary and surface mounting bracket, model F73.100 Fig. right: adjustable stem and dial version, model S73.100 Description This series of thermometers is universally suitable for machine building, plant and apparatus construction. Gas-actuated thermometers with capillary are used in locations which are not easily accessible and where long distances have to be bridged. The stem, the process connection and the case of the instrument 1) are made from stainless steel. To allow fitting to the process, different installation lengths and process connections are available. The thermometers have a high ingress protection of IP 65 and can be used in outdoor applications even at negative temperatures. With liquid damping operation under high vibration conditions is possible. Due to the wide variety of possible designs, the model 73 gas-actuated thermometers can be perfectly adapted to any process connection or location. The adjustable stem and dial version can be adjusted to any angle to allow easy reading. With the contact bulb version, temperature measurements are possible without any contact with the medium, even when the pipe diameter is extremely small. The contact bulb is intended for external mounting on pipes and tanks. When mounting this thermometer version, it must be ensured that the contact bulb is in contact with the measuring point over its complete length. 1) Not for model Q73.144, edgewise panel case galvanised steel Page 1 of 11

Standard version Measuring principle Gas-pressure inert gas filling, physiologically safe Nominal size in mm 100, 160, 144 x 144 Connection design S Standard (male thread connection) 1) 1 Plain stem (without thread) 2 Male nut 3 Union nut (female) 4 Compression fitting (sliding on stem) 5 Union nut with fitting 6 Compression fitting (sliding on capillary and/or spiral protection hose) 7 Compression fitting at the case 1) Not for version with capillary and edgewise panel design Models Model NS Version A73.100 100 Back mount (axial) A73.160 160 R73.100 100 Lower mount (radial) R73.160 160 S73.100 100 Back mount, adjustable stem and dial S73.160 160 F73.100 100 Version with capillary F73.160 160 Q73.144 144 x 144 Edgewise panel design Accuracy class Class 1 per EN 13190 Working range Normal (1 year): Measuring range (EN 13190) Short time (24 h max.): Scale range (EN 13190) Rated operating ranges and conditions EN 13190 Case, bezel ring, stem, process connection Stainless steel Adjustable stem and dial version Stainless steel, swivelling 90 and rotatable 360 Length to user specifications Dial Aluminium white, black lettering Window Laminated safety glass (at edgewise panel design: shatterproof plastic) Pointer Aluminium, black, micro adjustment Temperature limits for storage and transport -50 +70 C without liquid damping -20 +60 C (EN 13190) with liquid damping Permissible ambient temperature at case 0 40 C max. (others on request) Permissible pressure rating of stem max. 25 bar, static Ingress protection IP 65 per EN 60529 Exception with model Q73.144: IP 65 at the front IP 40 at the back Mounting types for F73.xxx Surface mounting flange, stainless steel Surface mounting bracket, die cast aluminium Panel mounting flange, stainless steel Triangular bezel with clamp, polished stainless steel Options Scale range F, C/ F (dual scale) Case with liquid damping Case with food-compatible liquid damping Armoured or coated capillary: armoured capillary Ø 7 mm, flexible or capillary with PVC coating 6, 10, 12 mm (others on request) Ingress protection IP 66 Thermometer with switch contacts (data sheet TV 27.01) Special measuring ranges or dial printing to customer specifications (on request) Version per ATEX Ex II 2 GD c TX Edgewise panel case and panel frame Steel, galvanised Contact bulb 120 x 22 x 12 mm, stainless steel 1.4571 Capillary Ø 2 mm, stainless steel 1.4571, bending radius no less than 6 mm Page 2 of 11

Scale ranges, measuring ranges 1), error limits (EN 13190) Scale graduation per WIKA standard Scale range in C Measuring range in C Scale spacing in C Error limit ± C -80... +60-60... +40 2 2-60... +40-50... +30 1 1-40... +60-30... +50 1 1-30... +50-20... +40 1 1-20... +60-10... +50 1 1-20... +80-10... +70 1 1 0... 60 10... 50 1 1 0... 80 10... 70 1 1 0... 100 10... 90 1 1 0... 120 10... 110 2 2 0... 160 20... 140 2 2 0... 200 20... 180 2 2 0... 250 30... 220 5 2.5 0... 300 30... 270 5 5 0... 400 50... 350 5 5 0... 500 50... 450 5 5 0... 600 100... 500 10 10 0... 700 100... 600 10 10 1) The measuring range is indicated on the dial by two triangular marks. Only within this range is the stated error limit valid per EN 13190. Connection design Design standard (male thread connection) 1) Standard insertion length l1 = 63, 100, 160, 200, 250 mm NS G i d 4 3073050.05 100, 160 G ½ B 14 27 26 8 1) Not for version with capillary (F73.xxx) and edgewise panel design (Q73.144) 4 Diameter of the sealing collar Design 1, plain stem (without thread) Standard insertion length I 1 = 100, 140, 200, 240, 290 mm Basis for design 4, compression fitting Nominal size Dimensions in mm NS d 1 2) Ød a for a for axial adjustable stem and dial 100, 160, 144 x 144 18 8 15 25 2) Not applicable to version with capillary a Distance to case/ articulated joint 1 Plain diameter 3073050.05 Design 2, male nut Standard insertion length l 1 = 80, 140, 180, 230 mm NS G i Ød 3073050.05 100, 160, 144 x 144 G ½ B 20 27 8 M20 x 1.5 15 22 8 incl. collar Page 3 of 11

Design 3, union nut Standard insertion length l 1 = 89, 126, 186, 226, 276 mm NS G 1 i Ød 3073050.05 100, 160, 144 x 144 G ½ 8.5 27 8 G ¾ 10.5 32 8 M24 x 1.5 13.5 32 8 G 1 Female thread Design 4, compression fitting (sliding on stem) Insertion length l 1 = variable Length L = l 1 + 40 mm NS G i d 4 Ød 3073050.05 100, 160, 144 x 144 G ½ B 14 27 26 8 M18 x 1.5 12 24 23 8 Sealing ring 4 Diameter of the sealing collar Design 5, union nut with fitting Standard insertion lengths l 1 = 100, 160, 200, 250 mm NS G i d 4 100, 160, 144 x 144 G ½ B 14 27 26 8 M18 x 1.5 12 24 23 8 Option: Connection with union nut M24 x 1.5 with fitting M18 x 1.5 NS G i d 4 100, 160 M18 x 1.5 12 32 23 8 Design 6.1, compression fitting sliding on capillary (compression fitting is leak-proof) Insertion length l 1 = variable : standard 200 mm at = 6 mm standard 170 mm at = 8 mm standard 100 mm at = 10 mm NS G i d 4 100, 160, 144 x 144 G ½ B 14 27 26 8 4 Diameter of the sealing collar Sealing ring I F Capillary length 4 Diameter of the sealing collar 3073300.10 3073050.05 Page 4 of 11

Design 6.2, compression fitting sliding on capillary with spiral protection hose (compression fitting is leak-proof) Insertion length l 1 : 300 mm at = 6.8 mm 200 mm at = 10 mm : standard 200 mm at = 6 mm standard 170 mm at = 8 mm standard 100 mm at = 10 mm NS G i d 4 100, 160, 144 x 144 G ½ B 14 27 26 8 Design 6.3, compression fitting sliding on spiral protection hose (compression fitting is not leak-proof) Insertion length l 1 = variable : standard 200 mm at = 6 mm standard 170 mm at = 8 mm standard 100 mm at = 10 mm NS G i d 4 100, 160, 144 x 144 G ½ B 14 27 26 8 Sealing ring I F Capillary length 4 Diameter of the sealing collar Clamping ring I F Capillary length 4 Diameter of the sealing collar 3073300.09 3073300.10 Design 7, compression fitting at the case Insertion length l 1 = 400 mm : standard 200 mm at = 6 mm standard 170 mm at = 8 mm standard 100 mm at = 10 mm l B = standard 100 mm (others on request) NS G i d 4 Sealing ring 14042662.01 100, 160 G ½ B 14 27 26 8 I F Capillary length I B Mounting shaft 4 Diameter of the sealing collar Page 5 of 11

Dimensions in mm Model A73, back mount Model R73, lower mount Model S73, back mount, adjustable stem and dial 3073254.01 3073068.01 3073076.01 Table of dimensions for models A73 and R73 Nominal size Dimensions in mm Weight in kg NS b b 1 1) d d4 D 1 D 2 F 1) G 100 50 83 8 2) 26 101 99 83 G ½ B 27 1.1 160 50 83 8 2) 26 161 159 113 G ½ B 27 1.4 1) With scale ranges 0... 300 C the dimensions increase by 40 mm 2) Option: 6, 10, 12 mm Table of dimensions for model S73 Nominal size Dimensions in mm Weight in kg NS b b 1 d D 1 D 2 F 100 50 93 8 2) 101 99 68 1.3 160 50 93 8 2) 161 159 68 1.6 2) Option: 6, 10, 12 mm Page 6 of 11

Model F73, with capillary and surface mounting flange Model F73, with capillary and surface mounting bracket Model F73, with capillary and panel mounting flange Model F73, with capillary and triangular bezel with clamp 3073289.02 3073297.02 3073165.02 3073270.01 Table of dimensions for model F73 (with capillary) Nominal size Dimensions in mm Weight in kg NS b b 1 d d 1 d 2 d 3 D 1 D 2 D 3 h 100 50 53 8 1) 116 132 4.8 101 99 107 107 1.4 160 50 53 8 1) 178 196 4.8 161 159 166 172 1.8 1) Option: 6, 10, 12 mm Page 7 of 11

Model A73, with contact bulb Back mount (BM) 3107884.01 Model R73, with contact bulb Lower mount (LM) 3107892.01 Case rotatable approx. 350 Model S73, with contact bulb Back mount, adjustable stem and dial Case rotatable approx. 350, swivelling 90 3107906.01 Table of dimensions for models A73, R73 and S73 (with contact bulb) Model Nominal size Dimensions in mm Weight in kg NS b b 1 D 1 D 2 A73.100 100 50-101 99 0.8 A73.160 160 50-161 159 0.9 R73.100 100 50-101 99 0.8 R73.160 160 50-161 159 0.9 S73.100 100 50 93 101 99 0.9 S73.160 160 50 93 161 159 1.0 Page 8 of 11

Model F73, with contact bulb Capillary and surface mounting flange Model F73, with contact bulb Capillary and surface mounting bracket 3107949.01 3107957.01 Model F73, with contact bulb Capillary and panel mounting flange 3107965.01 Model F73, with contact bulb Capillary and triangular bezel with clamp 3107973.01 Table of dimensions for model F73 (with contact bulb and capillary) Nominal size Dimensions in mm Weight in kg NS b b 1 d 1 d 2 d 3 D 1 D 2 D 3 h 100 50 53 116 132 4.8 101 99 107 107 1.4 160 50 53 178 196 5.8 161 159 166 172 1.8 Page 9 of 11

Model Q73.144, edgewise panel design Edgewise panel case, 144 x 144 mm, lower back capillary entry 3147355G Panel cutout in mm max. 20 3147355G.01 Mounting instructions for contact bulb General The contact bulb has been designed for mounting on pipes or tanks. When mounting this thermometer version, it must be ensured that the contact bulb is in contact with the measuring point over its complete length. The basic requirements to ensure a perfect measurement result is to retain good thermal contact between the skin mounted contact bulb and the outside wall of the pipe or tank with minimal heat loss to ambient from the skin mounted contact bulb and measuring point. Bend protector Capillary 3107876.01 Mounting on pipes The geometry of the contact bulb has been designed for pipes with external diameters between 20 and 160 mm. The skin mounted contact bulb should have direct metallic contact with the measuring point and have firm contact with the surface of the pipe. Where temperatures under 200 C are to be expected, a heat conducting paste can be used to optimise the heat transmission between skin mounted contact bulb and pipe. Lagging must be applied where the skin mounted contact bulb has been mounted, in order to avoid error due to heat loss. This lagging must have sufficient temperature resistance and is not provided with the instrument. Mounting on tanks The geometry of the contact bulb has been designed for tanks with an external radius up to 80 mm. If the mounting point of the skin mounting contact bulb on the tank has an external radius greater than 80 mm, we recommend the use of an intermediate piece designed for the respective tank diameter, made of a material with good thermal conductivity. The contact bulb should be fastened to the tank by means of an angle bracket with clamping screws, or any similar method. The skin mounted contact bulb should have direct metallic contact with the measuring point and have firm contact with the surface of the tank. Tube clip mounting Lagging 3107922.01 A heat conductive paste can be used to optimise the heat transmission between skin mounted contact bulb and tank if temperatures under 200 C are to be expected. Lagging must be applied where the skin mounted contact bulb has been mounted, in order to avoid error due to heat loss. This lagging must have sufficient temperature resistance and is not provided with the instrument. Angle bracket mounting Lagging 3107930.01 Page 10 of 11

Ordering information Model / Nominal size / Scale range / Design of connection / Process connection / Length I 1 / Capillary length IF / Options 2006 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 12/2012 GB Page 11 of 11 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. (+49) 9372/132-0 Fax (+49) 9372/132-406 E-mail info@wika.de www.wika.de