International approvals.

Similar documents
Unused flameproof threads for cable glands have to be closed with certified plugs.

A good connection. International approvals.

A good connection. International approvals.

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

EX-REPAIR AND MAINTENANCE RECEPTACLES

I Ex-safety switches I

Main current switches >180 A are realized in metal enclosures. Internationally approved.

I Ex-Safety switches I

Internationally approved.

I Ex-safety switches I

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

I Ex-control stations I

EX-D ENCLOSURES AND DISTRIBUTIONS

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

ELECTRICAL CONNECTIVITY

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

10 Load and Motor Switchgear

Installation Accessories

I Ex-e/Ex-i terminal box I

EX-RECESSED CEILING LIGHT FITTINGS

Dust - an Explosive Risk

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Leading the way in hazardous areas Features EATON

Safety Switches Series 8537

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

LED Linear Luminaire Series EXLUX 6402

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Sicherheit, auf die Sie sich verlassen können

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Plug and Socket Devices SolConeX 16 A Series 8570

The Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.

7 Lighting Technology

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Emergency Light Fitting for Fluorescent Lamps Series 6009

New products Ex Equipment 2015

ellk/m 92 LED 400/800

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

7 Lighting Technology

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Linear fluorescent luminaire LED V-CG-S

11 Control Panels, Distribution Panels and Components

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Linear Luminaire with LED Series EXLUX 6402/2

Load disconnect switch Series 8146/5-V11

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Operating Instructions

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Terminal Boxes Series 8125

Explosion protected terminal boxes type, GHG 72.

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Control Device System NEC Series ConSig 8040

Emergency Luminaire with LED Series EXLUX 6409/1

EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS

Linear luminaire with LED Series EXLUX 6002

7 Lighting Technology

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Sheet-Steel Light Fittings Series 6014 / 6414

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

ellk 92 LED Light Fittings

Linear Luminaire with LED Series EXLUX 6002

Load and Motor Switches, Load-Break Switches Series 8549

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Junction box for EKL light

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

9 Control Equipment. Control Unit System Series ConSig 8040

YFC. Limit switch. Ex d. 24 operating head types

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

EX-FLUORESCENT LIGHT FITTINGS

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Ex UPS standard Series 8265

SynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

HTSB system System overview

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544

EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

SynergEX Panelboards for Hazardous Locations

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

Data sheet... Klippon Klippon POK 10 Ex

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Transcription:

E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for Zone 2. Non-stationary electrical apparatus have generally high requirements on the energy/power supply. Robust plugs and receptacles as well as a high chemical resistance are at the first glance very important. Electrical reliability is a must not only for all connectivity products. A high safety standard, a steady hold and faultless contacting even under vibration or the effects of an aggressive atmospheric environment are the basis for a secure and reliable utilisation CEAG plugs and receptacles offer more, apart from the proven technology, this product series is defined by its innovative details. For example, the very efficient cable strain relief or the new coding system of the various versions offers different solutions for a secure and problem free utilization in all areas. Just to round the product off, the user in the normal industrial sector becomes exactly the same product advantages. Robust industrial versions fulfil all requirements appertaining to mechanical and chemical durability. For the stationary repair power supplying in hazardous explosive areas, there is a specially conceived version available that fulfils all the necessary safety requirements. Used in a module sense, individual solutions are no problem at all. The CEAG wall socket for instance can be mounted on to the pre-installed mounting frame without having to use tools installation without a hot work permit. Apart from the plugs and receptacles for the European market, we also have plugs and sockets extra for the US market, which are in accordance to all of the necessary standards UL and safety protection systems used there. The available standard range used here, are the 20 A, 30 A, 0 A and 00 A. International approvals. Safety standard IP applies also in the plugged-in state Full AC-3 switching ability Self-cleaning lamellar contacts, low transition resistance All-pole on/off switching Easy plugging 2..5 EATON S CROUSE-HINDS BUSINESS

I Zone 2: A 3-pole, 4-pole and 5-pole up to 90 V I Coupler Flange socket Technical data Ex-plugs and receptacles acc. to IEC 0309-/2 A Marking accd. to 94/9/EC II 3 G Ex nc IIC T5/T EC-Type Examination Certificate PTB 99 ATEX 5 Permissible ambient temperature -20 C up to +40 C ) Rated voltage up to 400 V (3-pole) / 750 V (4-pole) / 500 V (5-pole) AC Rated current up to A Frequency up to 400 Hz Rated making / Rated breaking capacity AC-3 accd. EN 0947-3 400 V / A External back-up fuse, max. without therm. protection: A with therm. protection: 35 A gl (rated current A set to) Protection class I Degree of protection accd. to EN 0529 IP Cable entry x M25 Ø 8-7 mm, x M25 plastic Ex-screw plug or 2 x metal thread M20 with plastic Ex-screw plug Connecting terminals 2 x.5-4 mm 2 glass-fibre reinforced polyester Cable entry Ø 8-9 mm (3-pole) / Ø 8-2 mm (4-pole) / 2-2 mm (5-pole) Connecting terminals x.0-2.5 mm 2 Coupler Cable entry Ø 8-9 mm (3-pole) / Ø 8-2 mm (4-pole) / 2-2 mm (5-pole) Connecting terminals 2 x.5-4 mm 2 Flange socket Connecting terminals 2 x - 4 mm 2 ) extended temperature range on request EATON S CROUSE-HINDS BUSINESS 2..57

I Zone 2: A 3-pole, 4-pole and 5-pole up to 90 V I Flange socket Coupler Ordering details Voltage h Type Cable entry Weight approx. Order No. Type A 3-pole 0-30 V KU.2 kg GHG 5 4304 R000 ME.3 kg GHG 5 4304 R300 Flange socket 0.4 kg GHG 5 8304 R000 Coupler 0.7 kg GHG 5 3304 R000 4 0.35 kg GHG 5 7304 R000 200-250 V KU.2 kg GHG 5 430 R000 ME.3 kg GHG 5 430 R300 Flange socket 0.4 kg GHG 5 830 R000 Coupler 0.7 kg GHG 5 330 R000 0.35 kg GHG 5 730 R000 Type A 4-pole 200-250 V KU.8 kg GHG 5 4409 R000 ME.9 kg GHG 5 4409 R300 Flange socket.0 kg GHG 5 8409 R000 Coupler.7 kg GHG 5 3409 R000 9 0.7 kg GHG 5 7409 R000 380-45 V KU.8 kg GHG 5 440 R000 ME.9 kg GHG 5 440 R300 Flange socket.0 kg GHG 5 840 R000 Coupler.7 kg GHG 5 340 R000 0.7 kg GHG 5 740 R000 480-500 V KU.8 kg GHG 5 4407 R000 ME.9 kg GHG 5 4407 R300 Flange socket.0 kg GHG 5 8407 R000 Coupler.7 kg GHG 5 3407 R000 7 0.7 kg GHG 5 7407 R000 00-90 V KU.8 kg GHG 5 4405 R000 ME.9 kg GHG 5 4405 R300 Flange socket.0 kg GHG 5 8405 R000 Coupler.7 kg GHG 5 3405 R000 5 0.7 kg GHG 5 7405 R000 Type A 5-pole 200-250 V KU.8 kg GHG 5 450 R000 380-45 V ME.9 kg GHG 5 450 R300 Flange socket.0 kg GHG 5 850 R000 Coupler.7 kg GHG 5 350 R000 0.7 kg GHG 5 750 R000 other voltage ranges and versions, e.g. with aux. contact, on request KU = x plastic cable glands M25 Ø 8-7 mm, x M25 plastic Ex-screw plug ME = 2 x metal thread M20 with plastic Ex-screw plug 2..58 EATON S CROUSE-HINDS BUSINESS

I Zone 2: A 3-pole, 4-pole and 5-pole up to 90 V I Coupler Flange socket Dimension drawing I Wiring diagram 90 X80 2 0 X00 47 7 7 3-pole 7.5 ~92 3-pole 4 pole 7.5 5 pole 84 4/5-pole ~92 Flange socket 3-pole X = fixing dimensions Dimensions in mm 9.5 7.5 (4-pole) 9.5 4-pole 7.5 5-pole 84 223 55 X5 4/5-pole 7.5 72 90 7.5 (4-pole) 84 (5-pole 23 75 X35 9 23 90 ~284 Coupler 3-pole Coupler 4/5-pole 0 9.5 X53 83 75 0 9.5 Flange socket 4/5-pole X9,5 83 75 Ø3.5 Ø5 X53 Ø83 Ø74 X9,5 8.5 0 25 5 M4 30 Assembly dimensions flange socket M5 Ø0 Assembly dimensions flange socket L N PE L L2 L3 PE L L2 L3 N PE P + N + PE 3P + PE 3P + N + PE EATON S CROUSE-HINDS BUSINESS 2..59

I Zone 2: A 3-pole, 4-pole and 5-pole up to 90 V I Mounting plate cap Protective canopy Accessories Mounting plates for wall sockets A Type Application Fixing method Order No. Size 4 for wall mounting snap on GHG 0 953 R02 Size 4 for trellis mounting snap on GHG 0 953 R02 Size 4 for pipe clamp snap on GHG 0 953 R030 cap for plugs A Type A 3-pole A 4-pole A 5-pole Order No. GHG 50 90 R000 GHG 50 90 R0002 GHG 50 90 R0003 Accessories for mounting plates Type OU Order No. Mounting set for pipes (Ø 27-30 mm) for mounting plates with pipe fixing 0 GHG 0 953 R0020 Please pay attention that only order units (OU) according to the ordering details can be delivered. Protective canopy for mounting plate Type Application Order No. Size 4 for mounting plate size 4, snap on GHG 0 955 R007 Dimension drawing 34.5 27 34.5 8 29 4 95 Mounting plate size 4 for wall/trellis mounting Mounting plate size 4 for pipe mounting Protective canopy size 4 Dimensions in mm 237 237 277 2..0 EATON S CROUSE-HINDS BUSINESS

I Zone 2: 32A 4-pole and 5-pole up to 90 V I Coupler Flange socket Technical data Ex-plugs and receptacles acc. to IEC 0309-/2 Marking accd. to 94/9/EC II 3 G Ex nc IIC T EC-Type Examination Certificate PTB 99 ATEX 5 Permissible ambient temperature 20 C to +40 C ) Rated voltage 90 V (AC) Rated current up to 32 A Frequency up to 400 Hz Rated making / Rated breaking capacity AC-3 accd. EN 0947-3 U e 90 V / I e 32 A External back up fuse without therm. protection: 35 A with therm. protection: 50 A gl (rated current 32 A set to) Protection class I Degree of protection accd. to EN 0529 IP Enclosure colour black Cable entry/enclosure drilling x M40 Ø 7-28 mm, x M40 plastic Ex-screw plug or 2 x M32 metal thread with 2 plastic Ex-screw plug Connecting terminals 2 x 4-0 mm 2 glass-fibre reinforced polyester Cable entry Ø 7-28 mm Connecting terminals x.0 - mm 2 Coupler Cable entry Ø 7-28 mm Connecting terminals 2 x 4-0 mm 2 Flange socket Connecting terminals 2 x 4-0 mm 2 ) extended temperature range on request EATON S CROUSE-HINDS BUSINESS 2..

I Zone 2: 32A 4-pole and 5-pole up to 90 V I Flange socket Coupler Ordering details Voltage h Type Cable entry Weight approx. Order No. Type 32 A 4-pole 200-250 V KU.8 kg GHG 57 4409 R000 ME.9 kg GHG 57 4409 R300 Flange socket.0 kg GHG 57 8409 R000 Coupler.7 kg GHG 57 3409 R000 9 0.7 kg GHG 57 7409 R000 380-45 V KU.8 kg GHG 57 440 R000 ME.9 kg GHG 57 440 R300 Flange socket.0 kg GHG 57 840 R000 Coupler.7 kg GHG 57 340 R000 0.7 kg GHG 57 740 R000 480-500 V KU.8 kg GHG 57 4407 R000 ME.9 kg GHG 57 4407 R300 Flange socket.0 kg GHG 57 8407 R000 Coupler.7 kg GHG 57 3407 R000 7 0.7 kg GHG 57 7407 R000 00-90 V KU.8 kg GHG 57 4405 R000 ME.9 kg GHG 57 4405 R300 Flange socket.0 kg GHG 57 8405 R000 Coupler.7 kg GHG 57 3405 R000 5 0.7 kg GHG 57 7405 R000 Type 32 A 5-pole 200-250 V KU.8 kg GHG 57 450 R000 380-45 V ME.9 kg GHG 57 450 R300 Flange socket.0 kg GHG 57 850 R000 Coupler.7 kg GHG 57 350 R000 0.7 kg GHG 57 750 R000 other voltage ranges and versions, e.g. with aux. contact, on request KU = x plastic cable glands M40 Ø 7-28 mm, x M40 plastic Ex-screw plug ME = 2 x metal thread M32 with plastic Ex-screw plug 2..2 EATON S CROUSE-HINDS BUSINESS

I Zone 2: 32A 4-pole and 5-pole up to 90 V I Coupler Flange socket Dimension drawing I Wiring diagram 20 X0 20 8 X0 285 205 X70 7 293 205 X70 7 4-pole 5-pole Dimensions in mm 9.5 0 00 9.5 00 95 00 4-pole ~249 5-pole ~249 90 90 90 95 90 00 Coupler 4-pole ~339 Coupler 5-pole ~345 9.5 Flange socket 4-pole 42 9 0 9.5 Flange socket 5-pole 42 9 X9,5 R3 X9,5 R3 Ø83 Ø78 72,4 X9,5 5 34 Ø83 Ø78 72,4 X9,5 34 5 32 32 0 M5 Ø Ø8.5 Assembly dimensions flange socket 0 M5 Ø Ø8.5 Assembly dimensions flange socket X = fixing dimensions L L2 L3 PE L L2 L3 N PE 3P + PE 3P + N + PE EATON S CROUSE-HINDS BUSINESS 2..3

I Zone 2: 32A 4-pole and 5-pole up to 90 V I Mounting plate cap Protective canopy Accessories Mounting plates for wall sockets 32 A Type Application Fixing method Order No. Size 5 for wall mounting snap on GHG 0 953 R028 Size 5 for trellis mounting snap on GHG 0 953 R028 Size 5 for pipe clamp snap on GHG 0 953 R032 cap for plugs 32 A Type 32 A 3-pole/4-pole 32 A 5-pole Order No. GHG 50 90 R0004 GHG 50 90 R0005 Accessories for mounting plates Type OU Order No. Mounting set for pipes (Ø 27-30 mm) for mounting plates with pipe fixing 0 GHG 0 953 R0020 Please pay attention that only order units (OU) according to the ordering details can be delivered. Protective canopy for mounting plate Type Application Order No. Size 5 for mounting plate size 5, snap on GHG 0 955 R008 Dimension drawing 80 27 80 8 74 7 95 Mounting plate size 5 for wall/trellis mounting Mounting plate size 5 for pipe mounting Protective canopy size 5 Dimensions in mm 25 25 305 2..4 EATON S CROUSE-HINDS BUSINESS

I Zone 2: 3 A 4- and 5-pole up to 90 V I Technical data Ex-plugs and receptacles acc. to IEC 0309-/2 up to 90 V Marking accd. to 94/9/EC II 3 G Ex nc IIC T EC-Type Examination Certificate PTB 99 ATEX 5 Permissible ambient temperature -20 C to + 40 C ) Rated voltage 90 V Rated current 3 A Frequency up to 400 Hz Rated making / Rated breaking capacity AC-3 accd. EN 0947-3 U e 90 V / I e 3 A External back up fuse without therm. protection: 3 A with therm. protection: 80 A gl (rated current 3 A set to) Protection class I Degree of protection accd. to EN 0529 IP Enclosure colour black Cable entry/enclosure drilling x M50 Ø 22-35 mm, x M50 plastic Ex-screw plug or 2 x M40 metal thread with plastic Ex-screw plug Connecting terminals 2 x 4-25 mm 2 / with cable lug 2) x 35 mm 2 glass-fibre reinforced polyester Cable gland Connecting terminals ) extended temperature range on request Ø 9-34 mm x 4 - mm 2 / x 25 mm 2 with pin cable lug 2) use supplied cable lugs 3) see accessories EATON S CROUSE-HINDS BUSINESS 2..5

I Zone 2: 3 A 4- and 5-pole up to 90 V I cap Ordering details Voltage h Type Cable entry Weight approx. Order No. Type 3 A 4-pole 200-250 V KU 8. kg GHG 58 4409 R000 ME 8.2 kg GHG 58 4409 R300 0.75 kg GHG 58 7409 R000 9 380-45 V KU 8. kg GHG 58 440 R000 ME 8.2 kg GHG 58 440 R300 0.75 kg GHG 58 740 R000 480-500 V KU 8. kg GHG 58 4407 R000 ME 8.2 kg GHG 58 4407 R300 0.75 kg GHG 58 7407 R000 7 00-90 V KU 8. kg GHG 58 4405 R000 ME 8.2 kg GHG 58 4405 R300 0.75 kg GHG 58 7405 R000 5 Type 3 A 5-pole 200-250 V KU 8.5 kg GHG 58 450 R000 380-45 V ME 8.25 kg GHG 58 450 R300 0.75 kg GHG 58 750 R000 Accessories cap for plugs Type OU Order No. Set of ring cable lug 35/70 mm 2 for wall socket ( + 2 pcs.) GHG 50 9 R000 cap 4-pole/5-pole GHG 50 90 R000 Set of cable lugs 35 mm² (5 pcs., for plug) 5 GHG 50 9 R000 other voltage ranges and versions, e.g. with aux. contact, on request KU = x plastic cable glands M40 Ø 7-28 mm, x M40 plastic Ex-screw plug ME = 2 x metal thread M32 with plastic Ex-screw plug 2.. EATON S CROUSE-HINDS BUSINESS

I Zone 2: 3 A 4- and 5-pole up to 90 V I Dimension drawing I Wiring diagram 200 X84 0 22 9 4/5-pole 4/5-pole X = fixing dimensions without aux. contact L L2 L3 PE L L2 L3 N PE 3P + PE 3P + N + PE 4-pole 5-pole Dimensions in mm Ø 0 475 370 X27 ca. 272 EATON S CROUSE-HINDS BUSINESS 2..7

I Zone 2: 25A 4- and 5-pole up to 90 V I Technical data Ex-plugs and receptacles acc. to IEC 0309-/2 to 90 V Marking accd. to 94/9/EC II 3 G Ex de IIC T EC-Type Examination Certificate PTB 99 ATEX 5 Permissible ambient temperature -20 C to + 40 C ) Rated voltage 90 V Rated current 25 A Frequency up to 400 Hz Rated making / Rated breaking capacity AC-3 accd. EN 0947-3 U e 90 V / I e 25 A External back up fuse without therm. protection: 25 A with therm. protection: 0 A gl (rated current 25 A set to) Protection class I Degree of protection accd. to EN 0529 IP Enclosure colour black Cable entry/enclosure drilling x M3 Ø 27-48 mm, x M3 plastic Ex-screw plug or x M50 Ø 2-35 mm, x M50 plastic Ex-screw plug Connecting terminals 2 x 4-50 mm 2 / with cable lug 2) x 20 mm 2 glass-fibre reinforced polyester Cable entry Ø 3-58 mm Connecting terminals x 4-35 mm 2 / with pin cable lug 3) x 50 mm 2 ) extended temperature range on request 2) use supplied cable lugs 3) see accessories 2..8 EATON S CROUSE-HINDS BUSINESS

I Zone 2: 25A 4- and 5-pole up to 90 V I Ordering details Voltage h Type Cable entry Weight approx. Order No. Type 25 A 4-pole 200-250 V KU 2.3 kg GHG 59 4409 R000 ME 2.5 kg GHG 59 4409 R300 0.9 kg GHG 59 7409 R000 9 380-45 V KU 2.3 kg GHG 59 440 R000 ME 2.5 kg GHG 59 440 R300 0.9 kg GHG 59 740 R000 480-500 V KU 2.3 kg GHG 59 4407 R000 ME 2.5 kg GHG 59 4407 R300 0.9 kg GHG 59 7407 R000 7 00-90 V KU 2.3 kg GHG 59 4405 R000 ME 2.5 kg GHG 59 4405 R300 0.9 kg GHG 59 7405 R000 5 Type 25 A 5-pole 200-250 V KU 3 kg GHG 59 450 R000 380-45 V ME 3.2 kg GHG 59 450 R300.2 kg GHG 59 750 R000 Accessories Type OU Order No. cap 4-pole/5-pole GHG 50 90 R0007 Set of ring cable lugs 70/20 mm 2 for wall socket (4 + pcs.) 5 GHG 20 9 R0004 Set of cable lugs 50 mm² (5 pcs., for plug) 5 GHG 50 9 R0002 other voltage ranges and versions, e.g. with aux. contact, on request KU = x plastic cable glands M40 Ø 7-28 mm, x M40 plastic Ex-screw plug ME = 2 x metal thread M32 with plastic Ex-screw plug EATON S CROUSE-HINDS BUSINESS 2..9

I Zone 2: 25A 4- and 5-pole up to 90 V I Dimension drawing I Wiring diagram 234 X28 258 9 4/5-pole 4/5-pole X = fixing dimensions L L2 L3 PE without aux. contact L L2 L3 N PE 3P + PE 3P + N + PE 4-pole 5-pole Dimensions in mm 537 430 X303 Ø 20 ~30 2..70 EATON S CROUSE-HINDS BUSINESS