AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

Similar documents
SINGLE DUCT TERMINAL UNITS

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Climas y Proyectos Leyco, S.A. de C.V.

forward curved inline duct blowers

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

DESIGN GUIDELINES FANS PAGE 1 of 7

Filtered Kitchen Supply Packaged Ventilator


FAN POWERED TERMINAL UNITS

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

University of Delaware

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

TSS Single-Duct VAV Terminals

Square Inline Fans with Multi-Directional Discharge

VANEAXIAL & TUBEAXIAL FANS

FAN POWERED TERMINAL UNITS

SDL Single-Duct, Low-Height, VAV Terminals

Complete HVAC Capability

SECTION AXIAL HVAC FANS

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Dual Duct Variable Air Volume Terminal (Model TDS)

Fixed Pitch Vane Axial Fan

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

Centrifugal Filtered Supply Roof Blowers

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

Model ND-2 Specification

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

SECTION CENTRIFUGAL HVAC FANS

SINGLE DUCT AIR TERMINAL UNITS

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

SECTION HVAC AIR CLEANING DEVICES

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

SECTION HVAC POWER VENTILATORS

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Direct Gas-Fired Heating

SINGLE DUCT AIR TERMINAL UNITS

2 Saudi Fan Industries

Tube Axial Fan Page Specifications & Dimension Data Performance Data

ARROW INDUSTRIAL PRODUCTS

Quiet-Duct Conic-Flow Silencers Section Specifications

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

VAHU Vertical Air Handling Unit

Application Guide TABLE OF CONTENTS: I. Introduction II. LHK Description III. Applications IV. Suggested Specification

KVL-P with Plate Shelf

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

Laboratory Room Single Duct Supply Air Terminal

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Twin City Fan & Blower

FILTERED SUPPLY CENTRIFUGAL Belt Drive

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

DIrect drive exhaust & supply panel fans

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

KVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood

Variable Air Volume (VAV) Pressure Independent Control

Horizontal and Vertical BELT DRIVE AIR HANDLING UNITS

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

AXIFAN VANEAXIAL FANS

Industry best 5 year fan housing warranty, 1 year motor warranty

Propeller Hooded Roof Fans

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

SECTION AIR TERMINAL UNITS

C2-2. Table of Contents DUAL DUCT TERMINAL UNITS

Catalog Air Terminal Units. Models MQTH, MQFCI and MQFVI. Model MQTH. Model MQFCI. Model MQFVI

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

READ AND SAVE THESE INSTRUCTIONS

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

FRP Fans: CLUB Series Performance and Technical Information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Industry best 5 year fan housing warranty, 1 year motor warranty

Inline Fans [ 14 ] * UL is optional and must be specified.

catalog SDL Single-Duct, Low-Height, VAV Terminals

catalog SDL Single-Duct, Low-Height, VAV Terminals

NON PRESSURIZED, GALVANIZED PREP ROOM Model #ENCG C-PREP

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

to obtain the specified voids due

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

Transcription:

ZONE INTERNATIONAL MIXED- COLUMN UNIT 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM

ZONE INTERNATIONAL MIXED- COLUMN UNIT T DUCT COLLAR INLET (A x B) PRIMARY RETURN RETURN 1" DOUBLE WALL MIXED FILTER RACK FOR 2" OR 4" FILTER FILTER ACCESS DOOR SWINGS DOWN DISCONNECT MINIMUM SPACE FOR CONTROLS BY OTHERS 2" DOUBLE WALL FAN ASSEMBLY ROLLER DEVICE ACCESS DOOR VF DRIVE SUPPLY FAN H Note 1 ACOUSTICAL BAFFLES TYP. SECURE SIDE OF DOOR MOTOR EASY ACCESS SIDE OF DOOR 12" Note 1 DISCHARGE SECTION (for 2, 3 OR 4-WAY DISCHARGE) W FRONT ELEVATION 1" DIMENSIONS IN INCHES MODEL Rated CFM A* B* X x Y T1 x T2 W1 x W2 VDT-03CU 1,500 10 12 14 x 21 32 x 32 36 x 36 VDT-06CU 3,000 12 20 16 x 26 40 x 40 44 x 44 VDT-10CU 5000 14 28 18 x 27 40 x 40 44 x 44 VDT-17CU 7,000 16 36 20 x 32 48 x 48 52 x 52 VDT-21CU 10,000 20 40 24 x 40 60 x 60 64 x 64 VDT-25CU 12,500 22 46 26 x 41 60 x 60 64 x 64 VDT-30CU 15,000 24 50 28 x 48 72 x 72 76 x 76 VDT-36CU 18,000 28 52 32 x 50 72 x 72 76 x 76 * SUGGESTED SIZE; VERIFY EXACT SIZE FROM PROJECT PLANS Note 1: Unit height will increase or decrease based on raised floor height. The height shown is for a 12" high raised floor. The unit lower chamber is built to accept the design floor height. 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM

ZONE INTERNATIONAL MIXED- COLUMN UNIT ARRANGEMENT Y ARR. 101 2-WAY LH X PRIMARY SUPPLY DUCT DAMPER & SENSOR PRIMARY ACCESS SIDE SENSOR ARR. 102 2-WAY RH W1 T1 (TOP OF UNIT) A ACCESS SIDE ARR. 103 3-WAY W2 T2 PRIMARY SUPPLY B ALT. INTAKE ACCESS SIDE ARR. 104 ACCESS SIDE 4-WAY W x W (BASE OF UNIT) CONTROLS BY OTHERS VF DRIVE PLAN VIEW DISCONNECT ACCESS SIDE Note: Purchaser must mark proper the discharge arrangement for each unit. DIMENSIONS IN INCHES MODEL Rated CFM A* B* X x Y T1 x T2 W1 x W2 VDT-03CU 1,500 10 12 14 x 21 32 x 32 36 x 36 VDT-06CU 3,000 12 20 16 x 26 40 x 40 44 x 44 VDT-10CU 5000 14 28 18 x 27 40 x 40 44 x 44 VDT-17CU 7,000 16 36 20 x 32 48 x 48 52 x 52 VDT-21CU 10,000 20 40 24 x 40 60 x 60 64 x 64 VDT-25CU 12,500 22 46 26 x 41 60 x 60 64 x 64 VDT-30CU 15,000 24 50 28 x 48 72 x 72 76 x 76 VDT-36CU 18,000 28 52 32 x 50 72 x 72 76 x 76 * SUGGESTED SIZE; VERIFY EXACT SIZE FROM PROJECT PLANS 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM

ZONE INTERNATIONAL SPECIFCATIONS VDT-CU Unit Floor is constructed of a welded tubular base frame and galvanized steel panels. The exterior panel is (min) 18-gauge solid galvanized G-90 steel and the interior is perforated with dual-density insulation. The floor is reinforced, braced and welded for rigidity to form a unitized assembly. The unit floor is complete with an aerodynamically shaped acoustical discharge assembly to control sound and properly direct the airflow to the individual openings. This unit is shipped in one piece unless otherwise specified at time of release. Unit Casing is constructed of double wall panels fabricated of (min) 18-gauge solid galvanized G-90 steel and the perforated interior sound panels with dual-density insulation, reinforced and supported with galvanized steel angles and channels to form a rugged assembly. A Foil Scrim Kraft (FSK) covering over the insulation in all perforated sound panels protects the air stream from loose insulation fibers. The casing panels are lined with 2# density dual density encapsulated between the inner and outer skin, in full accordance with NFPA 90A and UL 181. The internal liner is secured in place with a suitable UL listed adhesive. Full service access panels are provided on the access side of the unit for easy service. The filter access door and all panels are sealed with close-cell gaskets to prevent casing leakage. Access Doors are provided on the front of the unit with Ventlock latches and EPDM bulb type gaskets. Each access door is provided with (4) roller-ball handles for complete removal and easy access. Viewing windows with double-glazing and internal lighting are optional features. Fans are direct drive plenum type, selected for ultra-quiet performance and are rated according to AMCA. All fans are statically and dynamically balanced and operate below the fan first critical speed. The fan and motor assembly are mounted on a welded common tubular steel frame with open spring isolators and a quick release flexible connection at the fan inlet. The fan, motor and frame assembly is designed to roll out of the fan chamber on a unique suspension roller assembly for service or quick replacement. Motors are direct drive high efficient type, specifically tested for VFD operation; open drip proof or TE motors are factory mounted. Fan motor are mounted on an adjustable NEMA type base and factory wired. Filter Sections are provided in a flat arrangement designed to accept either 2 or 4 deep filters. Each filter is provided with gaskets to prevent unfiltered air and pull trays for easy removal and service. The unit is provided complete with one-set of factory installed 2-30% pleated filters. After commissioning the owner or installer may install the field provided 4 filters. Wiring Components include a VF Drive and disconnect switch factory installed and wired in accordance with NEC; the entire assembly is ETL Certified. The field connection is (min) 5-amp single point 480/3/60. Optional NEMA 12 design is available when required by local codes. Control Components are not included; all controls are the responsibility of others. Factory options include inlet flow sensors, VF drive interface and the installation of DDC controls furnished by others Exterior Finish is standard mill galvanized. All galvanized steel is G 90 with a minimum 1.25 ounces of zink per square foot on both sides and conform to ASTM A525, coating class, lock-forming quality. All welds are cleaned and protected with a minimum 4 mils zinc rich paint. Optional exterior painting with Air Zone pure white or pearl gray is available. Performance: Certified Independent Laboratory test provide NC 40 performance six-feet from the operating unit under mixed-flow and full flow conditions. Certified Test Results are available upon request. 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM

PHYSICAL DATA Model Rated CFM HP Fan NC Weight VDT-03CU 1,500 3/4 15" 40 1,250# VDT-06CU 3,000 1 22" 40 1,250# VDT-10CU 5,000 2 27" 40 1,505# VDT-17CU 7,000 2 36" 40 1,775# VDT-21CU 10,000 3 36" 40 2,150# VDT-25CU 12,500 5 44" 40 2,620# VDT-30CU 15,000 5 44" 40 2,620# VDT-36CU 18,000 7.5 49" 40 2,990# FILTER DATA Model Rated CFM (Qty) Size Area* Max. Vel. VDT-03CU 1,500 (4) 16" x 16" 7.11 211 VDT-06CU 3,000 (4) 20" x 20" 11.11 270 VDT-10CU 5000 (4) 20" x 20" 11.11 450 VDT-17CU 7,000 (4) 24" x 24" 16.00 438 VDT-21CU 10,000 (9) 20" x 20" 25.00 400 VDT-25CU 12,500 (9) 20" x 20" 25.00 500 VDT-30CU 15,000 (9) 24" x 24" 36.00 417 VDT-36CU 18,000 (9) 24" x 24" 36.00 500 * Gross Area Run testing of each unit is conducted at Air Zone International prior to shipment. The VF Drive is factory set to the required CFM. A two year warranty is provided on the VFD. 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM

5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM

ZONE INTERNATIONAL Certified Sound Performance Air Column Units OCTAVE BANDS VOLUME 1 2 3 4 5 6 7 8 NC CFM 63 125 250 500 1K 2K 4K 8K LEVEL 1,500 51 48 46 37 34 33 26 22 40 3,000 51 50 49 44 40 36 30 26 36 5,000 55 53 51 45 42 37 31 28 40 7,500 57 50 47 43 39 35 26 22 39 10,000 63 49 46 42 37 30 25 21 39 12,500 64 49 46 42 38 30 23 19 40 15,000 63 48 45 41 36 28 21 17 39 18,000 63 50 49 43 38 30 22 18 39 Certified Sound Data based on independent laboratory testing in a mock-up facility as shown below. TYPICAL TEST SET-UP 5220 TED STREET HOUSTON, TEXAS 77040 (713) 460-4040 (713) 460-4050 www.airzoneinc.com

5220 TED STREET HOUSTON, TEXAS 77040 (713) 460-4040 (713) 460-4050 www.airzoneinc.com

ZONE INTERNATIONAL 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM

ZONE INTERNATIONAL STANDARD NEMA 1 ENCLOSURE OPTIONAL NEMA 12 ENCLOSURE 460/3/60 BY OTHERS Supply Fan VF Drive DISCONNECT OR CIRCUIT BREAKER STANDARD NEMA 1 GREENFIELD OPTIONAL LIQUID TIGHT FLEXIBLE METALLIC CONDUIT FROM VFD TO DISCONNECT STANDARD NEMA 1 ENCLOSURE OPTIONAL NEMA 12 ENCLOSURE METAL RACEWAY WITHIN UNIT PANEL STANDARD NEMA 1 GREENFIELD OPTIONAL LIQUID TIGHT FLEXIBLE METALLIC CONDUIT FROM VFD TO DISCONNECT FAN MOTOR STANDARD OPEN DRIP PROOF MOTOR OPTIONAL TOTALLY ENCLOSED MOTOR Note: 1. All wiring in accordance with NEC. 2. Optional NEMA 12 construction complies with Chicago Building Code. 3. All units are ETL Certified 5220 TED ST. HOUSTON, TEXAS 77040 (713) 460-4040 FAX (713) 460-4050 WWW.ZONEINC.COM