THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

Similar documents
THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH

Thermal Dispersion & Paddle Type Flow Switch.

Thermal Dispersion & Paddle Type Flow Switch.

Thermal Dispersion & Paddle Type Flow Switch. visit our website

Thermal Dispersion & Paddle Type Flow Switch

SP/SF Series Flow Switches

Thermal Dispersion Flow Switch.

CAPACITANCE LEVEL SWITCH

TUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

ROTARY PADDLE LEVEL SWITCH

MAGNET FLOAT LEVEL TRANSMITTER

FINE AUTOMATION SIDE MOUNTING FLOAT SWITCH PRINCIPLE FEATURES WIRING

ROTARY PADDLE LEVEL SWITCH

INTRODUCTION FEATURES WORKING PRINCIPLE

Rotary paddle level switches

CABLE FLOAT LEVEL SWITCH

Magnetic Float Level Indicator

MINI BY-PASS LEVEL INDICATOR

FINE AUTOMATION ROTARY PADDLE LEVEL

FF Series Side Mount Float Level Switch

: 660 N. For material handling and clamping of small workpieces. CKZT25 -X2797 (Base Type) Power Clamp Cylinder INFORMATION. ø

Solid / Liquid Level Measurement for Field Application Pneumatic Vibrator/Air Shocker Solution Temperature Controller/ Counter /Digital Panel Meter

DOR Insertion Paddle Wheel Flowmeter

Rotary Paddle Level Switch

For material handling and clamping of small workpieces

MAIN FUNCTION FEATURES. . D = v t /2

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Pressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction

ISO-9001:2000 certified Aplus Finetek Sensor, Inc.

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

PRODUCTS GUIDE. Total solutions for monitoring liquid levels in the Marine Industry

Level Sensors and Switches Guided Radar (TDR) Radar Wave Level Sensors Ultrasonic Level Sensors Rotating Paddle Level Switches Vibrating Fork Level

DOR. Insertion Paddle Wheel Flow Meter / Monitor. for Low Viscosity Liquids

Flow switches Series AD/VH

PSF50 Paddle flow switch

ROTARY PADDLE LEVEL SWITCH

Plastic tube variable area flowmeter for liquids and gases

INTRODUCTION FEATURES

Rotary Paddle Level Switch

Inductive Proximity Sensor

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

SITRANS F M flow sensors 711/A and 711/911E

Pressure Level Transmitter.

INSTRUCTION MANUAL. Read before installing the recommendations and warnings on the last page of this manual. Vibra Switch S LEVEL SWITCH

FLOWX3 F3.60M.S Insertion Magmeter

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

ACTUATORS GENERAL CATALOG

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

GRB. long life Compact Angular gripper SHIPS IN 1-2 days. Major Benefits. Industry Uses

Series CRB2. Rotary Actuator Vane Style. Size: 10, 15, 20, 30, 40 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D- 20- Series Variations.

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

DPT TARGET TYPE FLOWMETERS

PHOTOELECTRIC S300 PA MAXI SENSORS APPLICATIONS.

M/S. BOMBAY INSTRUMENT MFG.CO.

Paddle-wheel flow controller with optical principle for On/Off control

DTK. OEM Pelton Wheel Flow Sensor

MAIN FUNCTION FEATURES. . D = v t /2

Installation and Operating Manual

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

DOR. Insertion Paddle Wheel Flow Meter/Monitor. for Low Viscous Liquids. Flow range: l/s to l/s. Flow velocity range: 0.

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Series ISA. Air Catch Sensor. For Detection of Work Presence

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

Inductive Proximity Sensor

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

Guide Table. MGF Series

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

SERIES PA SWING ARM CLAMPS for the Automotive Industry

RPFS. ROTA PULSE FLOW SENSOR (Slip Insertion Paddlewheel) DATASHEET FEATURES

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Capacitive level sensors CLS 23

Electronic Flow Monitor for liquids

ELECTRONIC CONTROL ACTUATOR

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

Series MSU. Rotary Table Vane Style. High Precision. Size: 1, 3, 7, 20 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D mm or less.

Pressure Switch. visit our website

Pressure Switch. visit our website

Valve Position Monitors

Level switches Series LC40 Float level switch for liquids

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

ROTARY PADDLE LEVEL SWITCHES

Miniature Liquid Level Sensors

Series MSU. Rotary Table. High Precision. Vane Type/Sizes 1, 3, 7, 20. High precision series MSUA introduced to vane type rotary tables CAT.

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

SRT1000 Series THERMAL FLOWMETER

Compact Proportional Solenoid Valve

INSERTION flow sensor for continuous flow measurement

Metal tube variable area flowmeter for gases, liquids and steam

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

ITS Series Position Monitoring Switch

Transcription:

THERMAL DISPERSION / PADDLE TYPE LEVEL SWITCH http: //www.fine-tek.com e-mail: info@fine-tek.com Tel: 886-2-22696789 Fax: 886-2-22686682 OPERATING PRINCIPLE Thermal dispersion flow switch is a precise flow sensing device, which uses heat diffusion principle. The probe consists of two temperature sensors. One sensor measures the temperature of the fluid where the probe is immersed. The other sensor is heated at a constant power. This creates a temperature difference between the two sensors. Temperature difference is inversely proportional to the flow velocity. The probe and housing are made by stainless steel or engineering plastic. Since the device has no moving parts, therefore there is no wear and tear problem. FEATURE Comparing to the traditional paddle type flow switch, thermal dispersion flow switch offers high sensitivity, no limitation of installing location, and no moving parts wear and tear. Different materials can be adopted to suit liquid with impurities, acidity, and alkaline. Probe length is made to fit requested application specification. There are three different output signals for users to choose. APPLICATION Water Power Plant, HVAC Systems, Steel Making, Petrochemical, Shipyard, Food Process, Pharmaceutical, Optical, Semiconductor, and any transporting pipes and cooling pipes flow control. 1

PRODUCT SPECIFICATION HEX38 HEX38 HEX38 40.5 Drawing 40.5 M12 M12 59.5 72.5 M12 G 1/2" 31 G 1/2" f16 L (Max.200 1/2"PF L=31 Model SP200-9-99-9-9 SP201-9-99-9-9 SP202-9-99-9-9 Measuring Range Ambient Temperature -20 ~ 120BC Operating Temperature -20 ~ 120BC Alarm Output Open Collector : NPN / PNP(<400mA Operating Pressure 100 bar (max. 100 bar (max. 100 bar (max. LED Indication Flow velocity below set point- Red LED on, Open Flow velocity equals set point- Yellow LED on, Close Flow velocity above set point- 4 Green LED to indicate flow speed, Close Housing SUS304 / 316L SUS304 / 316L Protection Level IP67 SUS304/ 316/ 316L Warm-up Time Approx.10 Sec Connection Thread G1/2, G1/4, NPT1/2 G1/2, NPT1/2 G1/2, G1/4, NPT1/2 Operating Voltage 19 ~ 30Vdc Power consumption 50mA (max. Wiring 3-wire NPN/PNP Power-brown Grounding-blue Output-black Accessory Gasket, 2m Cable 2

PRODUCT SPECIFICATION 40 M12 HEX38 Drawing M12 40.5 106 G 1/2" 31 1/2"PF 30 19.8 L=31 Model Measuring Range Ambient Temperature Operating Temperature SP203-9-99-9-9 Water: 1~70 cm/s Oil: 2~100 cm/s SP220-9-99-9-9 Alarm Output Open Collector : NPN / PNP(<400mA Operating Pressure 100 bar (max. 100 bar (max. LED Indication Flow velocity below set point- Red LED on, Open Flow velocity equals set point- Yellow LED on, Close Flow velocity above set point- 4 Green LED to indicate flow speed, Close Housing Protection Level Warm-up Time Connection Thread PVDF IP67 G1/2, NPT1/2 PC IP65 G1/2, NPT1/2 Operating Voltage Power consumption 19 ~ 30Vdc 50mA (max. Wiring 3-wire NPN/PNP Power-brown Grounding-blue Output-black Accessory Gasket, 2m Cable 3

PRODUCT SPECIFICATION Sight Window f70 f70 46 46 Drawing PG 78 78 32 32 Model Measuring Range Ambient Temperature Operating Temperature Alarm Output Operating Pressure 31 f38 SP210-1 Stainless Steel Type Relay: 5A/250Vac 100 bar (max. G1/2" 31 f38 SP170-(1/2 Explosion Proof Type G1/2" Cert. Number GYJ071446 Relay: 3A/250Vac 100 bar (max. LED Indication Flow velocity below set point- Red LED on, Open Flow velocity equals set point- Yellow LED on, Close Flow velocity above set point- 4 Green LED to indicate flow speed, Close Housing Protection Level Warm-up Time Connection Thread Operating Voltage Power consumption SUS304 IP67 G1/2, NPT1/2 19 ~ 30Vdc 60mA (max. SUS304 IP67 G1/2, NPT1/2 19 ~ 30Vdc 60mA (max. Wiring 5-wire Relay Output Power- red Grounding- black COM- white NC- yellow NO- blue F G NC C NO Accessory Gasket, 2m Cable 4

INSTALLATION INSTALLATION Please use given water-proof gasket for installing. 1. "a"above and below the SP in diagram 1 has to be 4 times greater than its internal diameter of pipe.(fig. 1 2. Make sure that the pipe is bubble free for proper alarming.(fig. 2 3. For not-fully-filled pipes, SP is requested to be installed underneath. Liquid level needs to be higher than the probe height. (Fig. 3 4. SP must be tightly screwed to avoid liquid from leaking out. It can be installed in any angle. For best sensitivity and response speed, please refer to the installation in (Fig. 4 5. It is suggested to install filtering component in upstream to filter impurities. This is to protect the wear and tear to the device. a a a³4xd d Fig. 1 Fig. 2 Fig. 3 Fig. 4 5

CONNECTOR DIAGRAM 2 3 1 SENSITIVITY ALARM 4 Fig. 5 Wire terminal diagram (NPN, PNP and 1A relay output type Fig. 6 WIRING 3-wire NPN 3 1 4 Blue Brown Black Fig. 7, NPN output type wiring 4-wire NO 1 Brown 2 Blue 3 Green 4 Black Fig. 10, Relay output type wiring (NO 1 PNP 3 4 Brown Blue Black Fig. 8, PNP output type wiring NC 1 Brown 2 Blue 3 Green 4 Black Fig. 11, Relay output type wiring (NC 5-wire Red Relay Black White Yellow Blue Fig. 9, Relay output type wiring COM NC NO 6

CODE NAME INFORMATION SP29 9-9 - 99-9- 9 - ( 9999 Model Description 0: Compact Type 1 : Stainless Steel Type(f70X78 2: Plastic Housing Economy Type Probe Type 0: Standard Type 1: Probe Extension Type (PVDF probe not available 2: 120BC High Temperature Type (plastic housing economy type not available 3: PVDF Anti-Corrosion Type Material 0: SUS304 6: SUS316 Connection L: SUS316L F: PVDF (for SP203 S: Other Size A: 3/8" (10A B: 1/2" (15A C: 3/4" (20A D: 1" (25A 2: 1/4" S: Other Specification Q: PT T: BSP R: PF U: NPT V: GAS S: Other Output *Standard thread connection: 1/2"PF, 1/2"NPT, 1/2"PT N: NPN (current limit: 400mA P: PNP (current limit: 400mA A: Relay 1A/30Vdc (NO B: Relay 1A/30Vdc (NC R: Relay 5A/250Vac (NC (for SP210/ SP211/ SP212 Cable Wire Length(unit: m 0: None 2: 2m 5: 5m Length L (Unit: mm * Tolerance of the total product length is 65mm * Characteristics, specifications and dimensions are subject to change without notice. * Please contact your nearest distributing office for further informations. * Max.200mm * PVDF and PTFE are available for standard models. 7

CODE NAME INFORMATION SP170-9 - 99-9 - ( 9999 Model Description 70 ---Explosion Proof Type Material 1: SUS304 2: SUS316L Size B: 1/2" (15A D: 1" (25A S: Other Specification Q: PT T: BSP R: PF V: GAS U: NPT S: Other Output R: SPDT 3A/250Vac Length L (Unit: mm * Tolerance of the total product length is 65mm * Characteristics, specifications and dimensions are subject to change without notice. * Please contact your nearest distributing office for further informations. * Max.200mm 8

PADDLE TYPE FLOW SWITCH Flow Switch utilizes the force of liquid flow to propel its paddle in order to detect the incoming flow or moving of the existing liquid in pipe. In condition of static liquid or no liquid, the spring is in expanding and press the magnet downward vertically. Reed switch contact is N.O. As flow occurs and the paddle is thrusted and raised at an upward angle of 20L~30L (or more, the eccentric of paddle will push the magnet upward to actuate the reed switch which is thus in a close circuit. The length of paddle can be adjusted with the diameter of a pipe. spring magnet reed switch CONFIGURATION CUTTING DRAWINGS 1. O-Ring 2. Paddle 3. Eccentric 4. Reed switch 5. Spring 6. Magnet 7. Housing 8. Screw 9. Center rod 1 9 3 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 2 5 6 4 8 7 eccentric paddle NEPSI MODEL: SF1710 80 MODEL: SF1800 Switch on in case of liquid flowing in pipes 80 *1/2"NPT spring magnet reed switch eccentric paddle Switch off in case of no moving liquid in pipes *Optional part 1/2"NPT used for SF1710 9

Model Spec. Housing Material Operation Temp. Paddle Material Operation Pressure Pressure Drop Allowance Set Point Tolerance Repeatability Tolerance Contact Capacity SF1710 Aluminum Alloy, Ex d IIC T6-30BC~100BC SUS304 Max. 355 PSIG 3 PSIG K25% K5% 60W 220Vac/200Vdc, SPDT SF1800 Aluminum Alloy, IP 65-30BC~150BC SUS304 Max. 355 PSIG 3 PSIG K25% K5% 60W 220Vac/200Vdc, SPDT FLOW CONTROL RANGE TABLE 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" Flow Volume Gallon Act. De-Act. Act. De-Act. Act. De-Act. Act. De-Act. Act. De-Act. Act. De-Act. Paddle Length Min. 1" 5 4 8.5 6.5 12 9 17 15 1-1/4" 1-1/2" 6.5 4.5 9 14 7 10 15 23 12 16 23 32 20 25 2" 2-1/2" 3" 18 12 24 20 17 13 33 27 22 27 22 16 1 Gallon=3.872 Litter INSTALLATION 1. Paddle length established approximate actuation setting of a Flow Switch unit. Paddle length is decided according to the lowest point of paddle while actuating the reed switch and the diameter of the pipe. Cut off the paddle at proper pipe size mark or wherever desired but not less than 1" left. 2. The paddle must be parallel to the cutting face of a pipe and the mounting screw is 1" NPT. 3. The FLOW mark on the screw hexagon must be parallel to the pipe and the ground. 4. Before installing the unit to a tee pipe, be sure to apply tape seal to the screw then tighten up. 1 It is not recommended to the 1" NPT plastic pipe. CAUTION 1. The pressure and temperature ranges as shown in the catalog, must not be exceeded and also take the abrupt pressure and temperature into considerations. 2. Operating temperature changes do affect switch set points. In case of the liquid temperature would vary with the specific gravity changes during processing, please contact us for assistance. 3. The flow switch is designed for shock and vibration resistance. However, shock and vibration should be as minimized as possible. 4. Excessive contamination in fluid might inhibit Paddle operation, occasional wipe-down would be necessary. 5. Electrical entry and mounting require sealing from moisture. (32Max 10