Troubleshooting Guide: 355 Lights (12V)

Similar documents
Troubleshooting Guide: 355 Lights (24V)

Troubleshooting Guide: 255 LED Light

Operation Manual. 355 Lighting System. Safety 2. Features 4. Component Overview 5. Controls & Indicators 6. Operation 7.

Operation Manual. 354 / 355 Combination Lighting System MA475900

Installation Manual. 355 Lighting System MA326100

354 Mobile Lighting System

Installation Manual. 355 Lighting System

Installation Manual. 354 / 355 Combination Lighting System MA475900

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18)

Installation Manual 354 / 355 Combination Lighting System

1 2 3a 3b THREADING CARD 9 10 ABC Office

Midmark Cabinet / Wall Light Installation

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

Maintenance Information

Maintenance Information

Operating Instructions & Parts Manual

AMCON AUTOMATIC CHART PROJECTOR USER S MANUAL EQ-6002

Introduction Easy operations Advanced owners Filling the Tank Filler cap Refueling

Service and Parts Manual

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.

OPERATION AND MAINTENANCE MANUAL

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

USER S MANUAL TUBE SEALER. Model SE250. No. CAT.SE25010Ce

ALU-29CF Portable Light NSN:

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

Q-04: Replace Brake Shoes/Adjust Brakes

Section 7 - Troubleshooting Guide

FD Conveyor for FD 260 Tabber

Sofa Slideout Assembly OWNER'S MANUAL. Rev: Page 1 Sofa Slideout Owners Manual

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

HLS Watt Halogen Illuminator Service Manual

FlexJet - Flex Cable Replacement

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

LAMPS 8L - 1 LAMPS CONTENTS

ASSEMBLY INSTRUCTIONS



Midmark Light Install: L/R mounted on Ultra Chair

MICRO WELD MODEL DP1 & DP2 HEAVY DUTY NON-FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

Loose Components. VetPro 5000 Wall / Cabinet Mount Installation. Applies to Models:

LA11 Tail, Parking, And Back-Up

M-1115S Series Fuel Pump

Embedded Rack Slide-out System

Some service parts may not be available for this product!

TB-690 Conveyor/Stacker

USER S MANUAL TUBE SEALER. Model SE450. No. CAT.SE45010Ce

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

IBT Series Square Drive Torque Wrenches

Cylinder and Valve: AirHawk II Air Mask

2010 F-650, 750 Super Duty Workshop Manual

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

OCTA FLUORESCENT 7 SOCKET FIXTURE

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures

USER S MANUAL & WARRANTY INFORMATION

920 Remote Control Switches

Stryker Visum 300 Ceiling-Mounted Exam Light Assembly, Operations, and Maintenance Manual

M-3025CB-AV Fuel Pump

INSTRUCTION MANUAL. Series PROCUNIER SAFETY CHUCK CO. (Serial Nos. B4870 and higher. (Serial Nos. B9230 and higher

Maintenance Information

TABLE OF CONTENTS. Ram Assembly

HLC CEILING MOUNTED DENTAL LIGHT. INSTALLATION and OPERATING INSTRUCTIONS. Rev.3

1989 Jeep Cherokee. STEERING COLUMN' '1989 STEERING Jeep Steering Columns STEERING COLUMN STEERING Jeep Steering Columns

OPERATING MANUAL AND INSTRUCTIONS

TABLE OF CONTENTS. Understanding the Troubleshooting Instructions...2 Signal Light...2 Harness Connections...2 Inspection...2

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

MAINTENANCE AND PARTS

Heavy Duty Miniature Quick-Change Applicator (Side-Feed Type) with Mechanical or Air Feed Systems

HexPro Series Low Profile Wrenches

Owner s Manual Currency Counter

Midmark Track Light Installation

INSTALLATION INSTRUCTIONS

Spotlight 1,000,000 Power Series Cordless Rechargeable

Trouble Shooting Guide EWA, 3-phase (D2422)

OFF TRUCK COMPONENTS PERSONAL PLOW

Low Profile Wrenches Operation and Maintenance Manual

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

Body Electrical System

BL7000 SYSTEM OPERATING MANUAL

Maintenance Information

OWNER S MANUAL & WARRANTY INFORMATION

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

OPERATOR MANUAL POLARIS TM Surgical Lighting Fixture. (1/18/99) P Rev. 3

MODEL SCA Installation and Operation Manual Important:

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

INSTALLATION INSTRUCTIONS

Alternator Removal and Installation Instructions

Scion xb Interior Light Upgrade Part Number: Accessory Code: YI1

XR Conveyor Maintenance Guide

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

3875 Cypress Drive Petaluma, CA Fax

NOTE: DISCONNECT MAIN POWER LOCK OUT AND TAG BEFORE PERFORMING ANY PROCEDURES IN THIS SECTION.

LED Downlight Ceiling Fixtures

OPERATION AND PARTS MANUAL

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

MODEL MA4210 Installation and Operation Manual Important:

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

OLYMPIAN MODEL 740 Operation and Service Manual

Transcription:

Troubleshooting Guide: 355 Lights (12V) Contents Description Refer To: Troubleshooting - Troubleshooting Chart Adjustments / Repair Procedures Bulb Replacing the Bulb Fuse(s) Replacing the Fuse (Ceiling) Replacing the Fuse (Mobile 120V) Replacing the Fuses (Mobile 230V) Lamp Tube Lamp Tube Brake Adjustment Lamp Tube Pivot Stop Replacement Cross Tube Cross Tube Counterbalance Adjustment Cross Tube Removal / Installation Down Tube Down Tube Removal / Installation Lighthead Lighthead Brake Adjustment Lighthead Removal / Pivot Bearing Replacement Ball Pivot Bearing Ball Pivot Adjustment Ball Pivot Repair Ball Pivot Stop Replacement Main Pivot Stop Main Pivot Stop Replacement Faceplate / IR Filter Cleaning the Faceplate / IR Filter English-1 004-1016-00 [Revised: 06/20/18

Troubleshooting Chart Problem Symptom Probable Cause Check Solution Light will not illuminate. Arm assemblies or lighthead does not rotate freely, or drifts when released. Light does not illuminate. ON / STANDBY switch is ON. Lighthead will not illuminate, or flashed intermittently when lighthead or arm assemblies are moved. Cross tube rotates (at ball pivot joint) too stifly, or drifts when released. Bulb is burned out. Inspect bulb. Replace bulb. Facility circuit breaker is tripped. Check facility circuit breaker. Reset circuit breaker. Line fues(s) blown. Inspect fuses. Replace fuse(s). Ceiling Mtd Lights Mobile Lights: (120V) (230V) Fuse holder malfunctioning. Perform continuity check on fuse holder. Replace fuse holder. Bulb socket is corroded resulting in bad connection. Inspect / clean bulb socket. Replace bulb socket. ON / STANDBY switch malfunctioning. Perform continuity check on switch. Replace ON / STANDBY switch. Transformer malfunctioning. Damaged / disconected wiring in the arm assemblies. 220V Mobile Lights only: AC inlet is malfunctioning. Damaged / disconected wiring in the arm assemblies. With the ON / STANDBY switch ON, check for 12.27 (+0.37) VAC across output leads of transformer. Perform continuity check on wiring from transformer to lighthead. Perform continuity check on AC inlet. Perform continuity check on wiring from transformer to lighthead. If 12.27 (+0.37) VAC is not present, Replace transformer. Repair / replace any damaged or disconnected wiring. (355 models: Wiring Diagrams) (354 / 355 Combo models: Wiring Diagrams) Replace AC inlet. Repair / replace any damaged or disconnected wiring. (355 models: Wiring Diagrams) (354 / 355 Combo models: Wiring Diagrams) Sterilizable handle not installed. Check if handle is installed. Install handle and adjust arm if necessary. Cross tube counterbalance out of adjustment. Ball pivot joint tension out of adjustment. Release tension from ball pivot joint and observe to see if the cross tube counterbalances corrrectly. Check for looseness / stiffness in joint. Cross tube counterbalance adjustment. then perform, Ball pivot joint tension adjustment. Lamp tube does not rotate freely (at cross tube), or drifts when released. Lamp tube brake tension out of adjustment. Check for looseness / stiffness in joint. Lamp tube brake adjustment. Lighthead does not rotate freely (at lamp tube), or drifts when released. Lighthead brake tension out of adjustment. Check for looseness / stiffness in joint. Lighthead brake adjustment. Ceiling Mtd Lights only: Down tube does not rotate, or drifts when released. Improper installation of ceiling plate. (Plate deflecting too much, or not level) Inspect ceiling plate. Check for level & excessive flexing. If ceiling plate is not level, readjust as necessary. If there is excessive flexing, support ceiling structure as necessary. (Refer to installation guide) English-2 004-1016-00 [Revised: 06/20/18]

Troubleshooting Chart - continued Problem Symptom Probable Cause Check Solution Arm assemblies can be rotated farther than specified. Lighthead will not operate properly. Mobile Lights only: Brake caster(s) will not lock. Cross tube can be rotated more than 580 in one direction. Lamp tube can be rotated more than 540 in one direction. Lighthead can be rotated more than 180 in one direction. Ceiling Mtd Lights only: Down tube can be rotated more than 580 in one direction. Lighthead assembly illuminates, but not at the proper intensity. Base moves when caster brakes are set. Ball pivot stop is broken. Inspect ball pivot stop. Replace ball pivot stop. Lamp tube pivot stop is broken. Inspect lamp tube pivot stop. Replace lamp tube pivot stop. Lighthead pivot bearing stop is broken. Inspect lighthead pivot bearing. Replace lighthead pivot bearing. Main pivot stop is broken. Inspect pivot stop. Replace main pivot stop. Bulb malfunctioning. - Replace bulb. Wrong input tap is being used on transformer, or facility voltage has changed since installation. Transformer malfunctioning Bulb socket corroded resulting in bad connection, or high resistance. Check facility input voltage & transformer input tap being used. With the ON / STANDBY switch ON, check for 12.27 (+0.37) VAC across output leads of transformer. Inspect / clean bulb socket. Select proper transformer input tap based on facility voltage. If 12.27 (+0.37) VAC is not present, Replace transformer. Replace bulb socket. IR filter is clouded or dirty. Inspect IR filter. Clean IR filter. Faceplate is clouded or dirty. Inspect faceplate. Clean faceplate. Caster brakes are worn or malfunctioning Inspect caster brakes. Replace brake caster(s) as necessary. Base not moving freely Broken caster Check condition of caster. Replace defective caster. Dirt not allowing caster to rotate. Check condition of caster. Remove dirt and/or replace caster. English-3 004-1016-00 [Revised: 06/20/18

Replacing the Bulb warning The maximum bulb wattage for this light is 100 Watts. There is a risk of fire if this limit is exceeded. Use Midmark part number: 002-0640-00. Caution To prevent electrical shock, the light must be in STANDBY mode ( O I ). Allow the light to cool before removing bulb. Move the lighthead away from the exam site to prevent contaminants from falling into the area. Equipment Alert Halogen bulbs are sensitive to body oils. Do not touch the glass portion of the bulb. If the glass portion of the bulb is handled, wipe with a clean soft lint-free cloth. Wipe with alcohol, then pat dry. Bulb To replace bulb.. A) Turn light switch to STANDBY ( O I ). B) Loosen three screws on top of lighthead. (Do not attempt to remove these screws). C) Separate top cap from lighthead housing. D) Pull bulb out of bulb socket, then discard. E) Grasp new bulb with a clean cloth, then insert into bulb socket. F) Align three top cap screws with holes, then tighten screws. Top Cap English-4 004-1016-00 [Revised: mo/dd/yr]

Replacing the Fuses: Ceiling Mounted Lights To replace fuses... A) Turn light switch to STANDBY ( O I ). B) Remove four screws, then lower ceiling cover. C) Using a flat-bladed screwdriver, rotate fuse cap counter-clockwise 1/4 turn, while pushing upward. D) Pull fuse out of fuse cap to inspect. E) Insert fuse into fuse cap. F) Using a flat-bladed screwdriver, rotate fuse cap clockwise 1/4 turn, while pushing into fuse socket. G) Install ceiling cover. Replacing the Fuses: Mobile Lights (120V models) To replace fuses... A) Turn light switch to STANDBY ( O I ). B) Disconnect power cord from light. C) Using a flat-bladed screwdriver, push in on fuse cap and rotate 1/4 turn. D) Remove fuse to inspect. E) Insert new fuse into fuse cap. F) Push fuse / cap into fuse holder and rotate 1/4 turn. NOTE: There are two fuses on this light. After removing the fuse, inspect it to determine whether it is faulty. Fuse Cap CRAFTSMAN MA8474i English-5 004-1016-00 [Revised: mo/dd/yr]

240230220 240230220 Replacing the Fuses: Mobile Lights (230V models) Equipment Alert The voltage setting that appears in the window of the fuse drawer, must match the facility voltage. To adjust the voltage setting, refer to Electrical Input Setting procedure. To replace fuses... A) Turn light switch to STANDBY ( O I ). B) Disconnect power cord from light. C) Using a flat-bladed screwdriver, push in on two locking tabs, then pull fuse drawer out. D) Pull fuses out of fuse drawer to inspect. E) Insert fuses into fuse drawer. F) Insert fuse drawer into AC inlet. (Push in until you hear a clicking sound). G) Connnect power cord. Voltage Window Locking Tabs 230 Voltage Selector Equipment Alert Locking tabs are fragile. Pull gently to prevent damage. Selector Lock Tabs MA8476i To adjust Electrical Input Setting... A) Pull out on two selector lock tabs, then pull voltage selector out of fuse drawer. B) Rotate voltage selector until the correct setting aligns with the voltage window. C) Insert voltage selector into fuse drawer. English-6 004-1016-00 [Revised: mo/dd/yr]

CRAFTSMAN Ball Pivot / Cross Tube Counterbalance Adjustments To release ball pivot tension... A) Slide sleeve up to expose opening. B) Insert screwdriver into adjustment hole. C) Move the screwdriver LEFT until tension is fully released. To adjust cross tube counterbalance... A) Remove cap from counterbalance. B) Loosen / tighten the adjustment screw until the cross tube balances in horizontal position. C) Install cap onto counterbalance. Sleeve Note: Turning the adjustment screw clockwise will raise the lighthead. Turning the adjustment screw counterclockwise will lower the lighthead. Cap Adjustment Hole Adjustment Screw To adjust ball pivot tension... A) Insert screwdriver into adjustment hole. B) Move the screwdriver LEFT / RIGHT to adjust tension setting (LEFT: decreases tension / RIGHT: increases tension) C) Remove screwdriver, and check for desired tension. Repeat until desired tension is achieved. D) Slide sleeve down, then install screw. English-7 004-1016-00 [Revised: mo/dd/yr]

Lamp Tube Brake Adjustment Lighthead Brake Adjustment To adjust lamp tube brake tension... A) Slide pivot sleeve up, then remove two screws. B) Separate lamp tube from cross tube. C) Loosen jam nut. D) Loosen / tighten adjustment nut as necessary. E) Hold adjustment nut in place, then tighten jam nut to 20-30 ft-lbs (27-40.7 N m). F) Reattach lamp tube / cross tube, secure with two screws. G) Check for proper operation. Repeat if necessary. Jam Nut Adjustment Nut Screws securing lamp tube / lighthead must installed properly. Failure to do so may allow lighthead to fall, resulting in injury. To adjust lighthead brake tension... A) Slide pivot sleeve back, then remove two screws. B) Separate lamp tube from lighthead. C) Loosen jam nut. D) Loosen / tighten adjustment nut as necessary. E) Hold adjustment nut in place, then tighten jam nut to 20-30 ft-lbs (27-40.7 N m). F) Reattach lamp tube / lighthead, secure with two screws. G) Check for proper operation. Repeat if necessary. Adjustment Nut Pivot Sleeve Jam Nut Pivot Sleeve English-8 004-1016-00 [Revised: mo/dd/yr]

Lighthead Removal / Pivot Bearing Replacement Disconnect power to the light before performing the following procedure. Failure to comply may result in electric shock. Step 1: Remove lighthead pivot bearing. A) Disconnect power to light. B) Slide pivot sleeve back, then remove two screws. C) Separate lamp tube from lighthead, disconnect two wires. D) Remove two nuts, washers, and pivot bearing. Washers Wave Washer Wave Washers Adjustment Nut Washers Jam Nut Pivot Sleeve Screws securing lamp tube / lighthead must installed properly. Failure to do so may allow lighthead to fall, resulting in injury. Step 2: Install lighthead pivot bearing. A) Install pivot bearing and washers as shown in illustration. B) Install two nuts, but do not tighten at this time. C) Loosen / tighten adjustment nut as necessary. D) Hold adjustment nut in place, then tighten jam nut to 20-30 ft-lbs (27-40.7 N m). E) Connect two wires. F) Reattach lamp tube / lighthead, secure with two screws. G) Check for proper operation. If necessary, separate lighthead, and loosen / tighten adjustment nut. English-9 004-1016-00 [Revised: mo/dd/yr]

Lamp Tube Pivot Stop Replacement Disconnect power to the light before performing the following procedure. Failure to comply may result in electric shock. Step 1: Remove lamp tube pivot stop. A) Disconnect power to light. B) Slide (lamp tube) pivot sleeve back, then remove two screws. C) Separate lamp tube from lighthead, disconnect two wires. D) Slide (cross tube) pivot sleeve back, then remove two screws. E) Separate lamp tube from cross tube. F) Cut two connectors off of wires coming out of the lamp tube. G) Pull two wires out of lamp tube. H) Remove two nuts, washers, pivot bearing, and pivot stop. Lamp Tube Pivot Sleeve Screws securing lamp tube / lighthead must installed properly. Failure to do so may allow lighthead to fall, resulting in injury. Wave Washers Step 2: Install lamp tube pivot stop. A) Install pivot stop, pivot bearing, & washers as shown in illustration. B) Install two nuts, but do not tighten at this time. C) Feed two wires thru lamp tube, then install two connectors. D) Connect two wires from lamp tube to lighthead. E) Reattach lamp tube / lighthead, secure with two screws. F) Loosen / tighten adjustment nut as necessary. G) Hold adjustment nut in place, then tighten jam nut to 20-30 ft-lbs (27-40.7 N m). H) Reattach lamp tube / cross tube, secure with two screws. I) Check for proper operation. If necessary, separate cross tube, and loosen / tighten adjustment nut. Adjustment Nut Jam Nut Lamp Tube Washers Pivot Sleeve English-10 004-1016-00 [Revised: mo/dd/yr]

Cross Tube Removal / Installation Disconnect power to the light before performing the following procedure. Failure to comply may result in electric shock. The cross tube / lighthead is very heavy. To prevent injury, use an assistant for the following procedure. Pivot Sleeve To remove cross tube... A) Disconnect power to light. B) Remove screw, then slide pivot sleeve up. C) While supporting cross tube / lighthead, remove two screws, then separate cross tube from down tube. D) Disconnect two wires and remove cross tube. Screws securing cross tube must be installed properly. Failure to do so may allow lighthead to fall, resulting in injury. To install cross tube... A) Connect wires as shown. (Install new wire connectors if necessary) B) Insert cross tube into down tube. (Do not pinch wires). C) Secure cross tube with two screws. (See NOTE) D) Refer to Ball Pivot Tension Adjustment if necessary. E) Slide pivot sleeve down, secure with screw. NOTE: There are three holes in ball pivot bearing. Two holes are larger with coarser threads. Use these two holes to secure cross tube. The other hole is pivot sleeve screw. English-11 004-1016-00 [Revised: mo/dd/yr]

Down Tube Removal / Installation (Ceiling Lights) Step 1: Remove cross tube / lighthead. Refer to: Cross Tube Removal / Installation. Step 2: Remove down tube. A) Remove four screws and ceiling cover. B) Remove two screws, then separate down tube. C) Pull two wires up thru down tube. Apply removable threadlocking adhesive. (Torque: 40 to 50 in-lbs (4.5 to 5.6 N m) Screws securing down tube must installed properly. Failure to do so may allow lighthead to fall, resulting in injury. To install down tube / ceiling cover... A) Install down tube, then secure with two screws*. Tighten screws to 40 to 50 in-lbs (4.5 to 5.6 N m) (* apply removable threadlocking adhesive to screws) B) Position ceiling cover, then secure with four screws. MA8549i English-12 004-1016-00 [Revised: mo/dd/yr]

Main Pivot Stop Replacement (Ceiling Lights) Step 1: Remove cross tube. Refer to: Cross Tube Removal / Installation. Step 2: Remove down tube. Refer to: Down Tube Removal / Installation. Equipment Alert Strain relief knot must be above the groove pin. Be sure that groove pin is between two wires, and that wires do not get pinched when pin is installed. Step 3: Replace main pivot stop. A) Using a punch, remove groove pin. B) Remove washer, pivot housing, and pivot stop. C) Inspect two stop pins. Replace pin(s) if damaged. D) Install main pivot stop, pivot housing, and washer onto shaft. E) Install groove pin. Stop Pins Step 4: Install down tube. Refer to: Down Tube Removal / Installation. Step 5: Install cross tube / lighthead. Refer to: Cross Tube Removal / Installation. Strain Relief Knot Groove Pin English-13 004-1016-00 [Revised: mo/dd/yr]

Ball Pivot Repair Retaining Ring Step 1: Remove cross tube. Refer to: Cross Tube Removal / Installation. Wave Washers Washer (large) Cam Step 2: Remove ball pivot assembly. A) Insert screwdriver into adjustment hole. B) Move the screwdriver LEFT until tension is fully released. C) Cut wire connectors from two wires. (Preserve as much wire length as possible) D) Using a punch, remove groove pin. Washer (small) Thrust Washer Washer (large) Adjustment Hole Pivot Bearing (install teflon side UP) CRAFTSMAN Step 3: Disassemble the ball pivot. A) Remove retaining ring and washer from ball pivot shaft. B) Using a punch, remove groove pin. (see NOTE) C) Disassemble ball pivot components from shaft / housing. D) Inspect pivot bearing for excessive wear. Replace if necessary. NOTE: Groove pin has serrations on one end. Do not drive serrations thru ball pivot shaft. Step 4: Assemble the ball pivot. A) Install pivot bearing, washers, and cam as shown. B) Install groove pin. C) Install washer, then secure with retaining ring. English-14 004-1016-00 [Revised: mo/dd/yr]

Ball Pivot Stop Replacement Step 1: Disassemble the ball pivot. Refer to: Ball Pivot Repair. Step 2: Replace ball pivot stop. A) Remove two flange bearings. B) Disassemble shaft / housing components. C) Inspect stop pin. Replace if necessary. D) Install pivot stop (with raised portion facing UP), housing, and brake onto shaft. E) Install two flange bearings into shaft. Pivot Stop (raised portion UP) NOTE: Groove pin has serrations on one end. Do not drive serrations thru ball pivot shaft. Step 3: Assemble the ball pivot. Refer to: Ball Pivot Repair. Stop Pin (replace if damaged) English-15 004-1016-00 [Revised: mo/dd/yr]

Cleaning the Faceplate / IR Filter Disconnect power to the light before performing the following procedure. Failure to comply may result in electric shock. To clean the faceplate / IR filter... A) Remove eight screw and the faceplate assembly. B) Do NOT touch the IR filter, the clear faceplate, or the interior surface of the reflector with bare fingers. C) Use a can of compressed air to clean the inside of the lighthead. English-16 004-1016-00 [Revised: mo/dd/yr]