Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

Similar documents
H Battery Distribution Fuse/ Circuit Breaker Bay (BDFB/BDCBB)

Installing Power Components

5067 Mini-BDFB Battery Distribution Fuse Bay

Installing and Removing Power Supplies

TPM/GMT Panel Installation Guide

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

GMT Fuse Panel Installation Guide

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

MX28B200/ VDC POWER SYSTEMS User s Manual (Document # )

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

PowerWorx DSX Series GMT Fuse Panel User Manual

ANZI Transfer Switch and Generator Wiring Installation Addendum

High Frequency SineWave Guardian TM

Unity Low Voltage Disconnect & Monitor

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

Cisco ASR 1002 Router Overview and Installation

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified

NTK599BAE5 and NTK599BGE5 Breaker Interface Panel (BIP) Installation Manual

Fuse / Circuit Breaker Panels

Switching DC Power Supply

8300 Series Installation Guidelines

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

MODEL ELC-12/60-D BATTERY CHARGER

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

CM52 Network Protector with Arc Flash Reduction Module

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Quik-Spec Coordination Panelboard

NetSure SERIES -48 VDC Power Distribution System. Installation and User Manual (UM ), Revision A

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Sunwize Power Ready Express Quick Start

Install the Shelf and Common Control Cards

SM50F48PM (-48V) Rectifier Module. Critical Power Product Manual. Part Number: SM50F48PMPD.

Cabinet and Rack Installation

Secondary DC Distribution

Cabinet and Rack Installation

Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit

Power and Cooling. Chassis Power System

Installing the Switch Chassis

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

Installing the Switch

Power Distribution System User s Manual. Model: PDS-100

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

U N I T Y / Three-Phase Uninterruptible Power Systems UT310, UT315, UT320, UT Hz

Freedom egen System End-of- Line Functional Checklist

Galaxy VX Battery Breaker Trip Board (GVXBBTB) and Battery Breaker Capacitor Board (GVXBBCB)

Lucent Technologies Whippany Physical Design

Wiring the 2015 FRC Control System

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

153M -48V POWER PLANT 5000 AMP

CARAVAN. Tow Vehicle Requirements Instructions. Various Models with 12-pin Plug. Fitting Time: 30 minutes

Battery Control Center - Diesel

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

User s Manual. Automatic Switch-Mode Battery Charger

Illuminator System Series CM

Connecting to DC Power

Installation Instructions for Key Switch SNOWRATOR

Wiring the 2016 FRC Control System

U N I T Y / Three-Phase Uninterruptible Power Systems UT3120, UT3160, UT Hz

Florham Park, NJ USA Call (ASCO) for sales or service

MDS2 Series. Modular Distribution Systems. Introduction 8-Position Configuration Decision Tables

Electrical Installation

Switch Installation. Preparing for Installation. Warnings CHAPTER

Wiring the FRC Control System

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

E.S.P. Embedded Sensing Probes for Motor Brushes

Elegance Electrician s Installation Guide

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

Illuminator System Series CIII

Sunwize Water Pumping Kit Quick Start

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

5300 Series Installation Guidelines

Technical Manual. DLM Module. This manual should remain with the unit.

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

STANDBY BATTERY LI TEL48-170C INSTALLATION AND OPERATING MANUAL

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Installation Instructions For Motor Control Center (MCC) Units

BR62 Battery Rack Installation, Operation, & Maintenance Manual

CSI-400 Installation Instructions

I n s t a l l a t i o n M a n u a l. f o r T E D

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

ACE Variable Frequency Drive System

Safety Working with LV Drives

Product Manual Select Code Comcode Issue 9 September Secondary DC Power Distribution Bay H

Transcription:

GE Critical Power Quick Start Guide Infinity 1U 19 Converter Shelf Models: J5964803 L224-48V to +24V, L225 +24V to -48V Edge Controller example Outputs RTNs Inputs RTNs Refer to Infinity Converter Brochure for details and accessories. Tools required: Wire cutters and strippers Cable crimpers Torque wrench - 0-65 in-lb (0-10Nm) Sockets - 5/16, 7/16, etc. Screwdrivers - Philips #1 and #2, Flat #1 Step 1 - Mount Shelf 1. Reposition mounting ears as required for desired set back - 4 screws each. Torque to 25 in-lb (2.8Nm) - Phillips screwdriver. 2. For 23 frames - Install optional mounting brackets (separately ordered) 3. Attach shelf to the frame using a minimum of four screws (two on each side) - 12-24 (provided). Torque to 35 in-lb (4Nm) - 5/16 socket. No vertical spacing is required. Provide 2 inch minimum clearance at back of shelf for converter airflow. Step 2 - Plan DC Feeds Inputs: Two Individual converter feeds Outputs: Six fused outputs (15A max fuses), total output load must not exceed output rating. Recommended breakers and cable sizes are in the tables below. Cable recommendation based on 45 C, raceway with up to 24 conductors. Note: Some installations do not require protectors on the inputs. Note: Input returns must be externally connected to DC Reference (CO) Ground. # Of Conv. L225: +24V in, -48V out (NE030DC48A) Input Output (rated) Amps Recommended Cable Breaker Amps 1 80A (1) 2 AWG 100A 30A 2 (2) 80A (2) 2 AWG (2) 100A 30A # Of Conv. L224: -48V in, +24V out (NE075DC24A) Input Output (rated) Amps Recommended Cable Breaker Amps 1 55A (1) 4 AWG 70A 30A 2 (2) 55A (2) 4 AWG (2) 70A 30A 1

Step 3 - Connect Chassis Ground Lug landing #10 double-hole lug on 5/8-inch center (not provided) Minimum 10 AWG recommended. Torque 10-32 screws to 30 in-lb - 5/16 socket. Some applications may rely on frame mounting screws for chassis ground omitting the chassis ground cable. Step 4 - Connect DC Input Connections for DC input are on the right front under a cover. CAUTION: Verify DC Input voltage and polarity with a voltmeter before proceeding. Note: Input returns must be externally connected to DC Reference (CO) Ground. 1. Remove Cover (1 screw) 2. Connect cables with suitable lugs to CONV 1 and CONV 2 input landings. -48V inputs are labeled -48Vdc and POS RTN +24V inputs are labeled +24Vdc and NEG RTN Note: Input Feed Returns must be externally connected to DC Reference (CO) ground. 3. Torque to 65 in-lb (7.3 Nm) - 7/16 socket 4. Replace cover Chassis Ground Lug Landing Left Rear #10 on 5/8 center DC Inputs Lug Landings - 1/4 on 5/8 center Tongue width - 0.7 (18mm) max. CONV 1 (Left) CONV 2 (Right) DC Input Returns Step 5 - Connect Loads (Outputs) Load terminal blocks are on the right front. Fuses - 15A max. Total Load Current - 30A max. Wire Size: 24-12AWG Strip Length: 0.35 (9mm) Loads Returns 1. Verify that fuse is not installed 2. Strip wires 3. Insert wires into terminal block to LOAD and associated RTNS positions 4. Tighten screw - 4 in-lb (0.45 Nm). 5. Pull wire to verify 6. Insert fuse J3/J4 not used SW2 Shelf ID J1 Alarm Outputs USB Craft Port J2 Alarm Inputs J5 LAN Signal Connections and Shelf Switches 2

Step 6 - Set Shelf Switches SW1 Set converter output voltage: 48V for L217; 24V for L218. V Sense alarm if not set correctly. SW2 Set shelf number: 1 for first shelf; 2 for second shelf, etc. Converter ID conflict alarm if two shelves are set to the same number. Step 7 - Set Jumpers - LAN Port and Relay per Galaxy Pulsar Edge Controller Quick Start Guide 1. Set Jumpers - LAN Port and Relay Relay Jumpers Step 8 - Install Controller 1. Install Controller Bracket in shelf. Torque to 5 in-lb (0.5 Nm) (Controller with display only). 2. Slide controller into slot in shelf. 3. Secure controller with thumb screw. Controller Bracket Step 9 - Install Alarm and LAN Cables Connectors are on rear. See Information: Connections for Details J1-2 Alarms and Inputs - Connect to office alarms and signals. J5 LAN - Connect to Ethernet network. Step 10 - Install Converters Slide the converter into the converter slot approximately 3/4 of the way. Open the faceplate by sliding the faceplate latch to the left until the faceplate releases and swings outward. Slide the unit into the slot until it engages with the back of the shelf. Swing the faceplate closed to fully seat the converter. Verify the faceplate is latched. Step 11 - Initial Start Up Verify that all DC and Alarm connections are complete and secure. Turn on DC input breakers. If there are no alarms, make required adjustments to the default settings on the controller for this installation. Step 12 - Configure Controller per Galaxy Pulsar Edge Controller Quick Start Guide Verify and edit controller basic configuration parameters per site engineering instructions. 13

Information: Controller Define Alarm Inputs and Outputs Converter Alarm Outputs: Select the Settings tab > Converters to set alarm thresholds, severity and relays on J1 connector. Select the drop down arrow next to the LED field and select ALM to activate the ALM LED for that alarm condition. Factory defaults are shown in the web page to the right. Auxiliary Alarm Inputs: Select the Settings tab > Auxiliary Inputs to define up to four external alarms through connector J2. Converter Alarm Outputs: Settings tab > Converters Auxiliary Alarm Inputs: Settings tab > Auxiliary Inputs Information: Controller Default Voltage Settings and Ranges Parameter Converter Internal Selective High Output Voltage Shutdown Range Default 24V 48V 48V 24V 25.0 to 30.0V 50.0 to 60.0V 58.0 29.0 High Output Voltage Major Alarm 25.0 to 30.0V 50.0 to 60.0V 56.0 28.5 High Output Voltage Minor Alarm 24.0 to 30.0V 48.0 to 60.0V 54.0 27.0 Output Voltage Set-Point 23.0 to 27.2V 46.0 to 54.5V 52.0 26.0 Low Voltage Alarm 20.0 to 27.0V 40.0 to 54.0V 46.0 23.0 24

Information: Connections - Alarm - J1 and J2 See the Infinity Converter Ordering Guide for details. Alarm connectors are on the rear of the shelf - J1 and J2. Change alarm descriptions via LAN port (Web pages) or Craft port (EasyView2) when required. J2 Alarm Input Cable 24AWG solid Ordering code Cable length CC848890203 5 ft CC848853614 15 ft CC848890211 50 ft CC848890228 150 ft Pin Color Description 1 Y Input: SPD Fail 2 S -- 3 O Input: AUX MAJ 4 V Input: Air Cond. Fail 5 W Input: Door Open 6 BL -48V 7 BR -48V 8 BK -48V J1 Alarm Output Cable 24GA solid Ordering Codes Cable Length CC848890153 5 ft CC848865980 15 ft CC848817651 50 ft CC848817668 150 ft Pin Color Description 1 BK Output: R3 = Rtn 2 BR Output: R2 = Rtn 3 R Output: R1 = Rtn 4 O Output: PMN Rtn 5 Y Output: PMJ Rtn 6 G Output: R3 = Converter Distribution Fuse 7 BL Output: R2 = Converter Fail 8 V Output: R1 = Very Low System Voltage 9 S Output: PMN 10 W Output: PMJ Specifications and Application Specifications and ordering information are in the Infinity S Power System Brochure available at www.gecriticalpower.com Equipment and subassembly ports: 1. are suitable for connection to intra-building or unexposed wiring or cabling; 2. can be connected to shielded intra-building cabling grounded at both ends. Grounding / Bonding Network Connect to an Isolated Ground Plane (Isolated Bonding Network) or an Integrated Ground Plane (Mesh- Bonding Network or Common Bonding Network). Installation Environment - Install in Network Telecommunication Facilities, OSP, or where NEC applies. DC Returns - Isolated DC return (DC-I) or Common DC return (DC-C). Reference Documents These documents are available at www.gecriticalpower.com. Document Title 850035894 Galaxy Pulsar Edge Controller Quick Start Guide CC848815341 Pulsar Edge Controller Family Product Manual Infinity S Power System Brochure 1 5

Safety Statements Do not install this equipment over combustible surfaces. Rules and Regulations - Follow all national and local rules and regulations when making field connections. Compression Connectors U. S. or Canada installations - use Listed/Certified compression connectors to terminate Listed/Certified field-wire conductors. All installations - apply the appropriate connector to the correct size conductor as specified by the connector manufacturer, using only the connector manufacturer s recommended or approved tooling for that connector. Electrical Connection Securing: Torque to the values specified on labels or in the product documentation. Cable Dress - dress to avoid damage to the conductors and undue stress on the connectors. Circuit Breakers and Fuses Use only those specified in the equipment ordering guide. Size as required by the National Electric Code (NEC) and/or local codes. Safety Tested Limits - Refer to the equipment ratings to assure current does not exceed: Continuous Load (List 1) - 60% of protector rating Maximum Load (List 2 - typically end of discharge) - 80% of protector rating. GMT Style Fuses - Use only fuses provided with safety caps. Field-wired Conductors - Follow all National Electric Code (NEC) and local rules and regulations. Insulation rating: 90 C minimum; 105 C (minimum) if internal to enclosed equipment cabinets. Size AC field-wired conductors with 75 C ampacity (NEC) equal to or greater than their panel board circuit breaker rating. AC and DC input disconnect/protection - Provide accessible devices to remove input power in an emergency. Alarm Signals - Provide external current limiting protection. Rating 60V, 0.5A unless otherwise noted. Grounding - Connect the equipment chassis directly to ground. In enclosed equipment cabinets connect to the cabinet AC service ground bus. In huts, vaults, and central offices connect to the system bonding network. Precautions Install, service, and operate equipment only by professional, skilled and qualified personnel who have the necessary knowledge and practical experience with electrical equipment and who understand the hazards that can arise when working on this type of equipment. Disconnect batteries from outputs and/or follow safety procedures while working on equipment. Batteries may be connected in parallel with the output of the rectifiers. Turning off the rectifiers will not necessarily remove power from the bus. Do not disconnect permanent bonding connections unless all power inputs are disconnected. Verify that equipment is properly safety earth grounded before connecting power. High leakage currents may be possible. Exercise care and follow all safety warnings and practices when servicing this equipment. Hazardous energy and voltages are present in the unit and on the interface cables that can shock or cause serious injury. When equipped with ringer modules, hazardous voltages will be present on the ringer output connectors. Use the following precautions in addition to proper job training and safety procedures: Use only properly insulated tools. Remove all metallic objects (key chains, glasses, rings, watches, or other jewelry). Follow Lock Out Tag Out (LOTO) procedures: customer specified, site specific, or general as appropriate. Disconnect all power input before servicing the equipment. Check for multiple power inputs. Wear safety glasses. Follow Personal Protective Equipment requirements: customer specified, site specific, or general as appropriate. Test circuits before touching. Be aware of potential hazards before servicing equipment. Identify exposed hazardous electrical potentials on connectors, wiring, etc. Avoid contacting circuits when removing or replacing covers;. Use a personal ESD strap when accessing or removing electronic components. Personnel with electronic medical devices need to be aware that proximity to DC power and distribution systems, including batteries and cables, typically found in telecommunications utility rooms, can affect medical electronic devices, such as pacemakers. Effects decrease with distance. 26

Notes 1 7

Notes GE 601 Shiloh Rd. Plano, TX 75074 1-888-546-3243 82 Document www.gecriticalpower.com 850035793 r02 2015 April Document 850033855 r01 2013 August