Fully Automatic Bilge Pump INSTRUCTION MANUAL

Similar documents
ICOMIA Global Conformity Guideline for ISO and ABYC Standards. Guideline Number 8 Ventilation of fuel systems

National Marine Manufacturers Association

1) Only gasoline exhaust systems shall be gas-tight to the hull interior

Model &

Ventilation Blowers 09. Introduction Heavy Duty Radial Blowers Radial Blowers In-Line Blowers

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

IMPORTANT INFORMATION

50830 Series Low Pressure Centrifugal Pump

Installation Instructions

ELECTRIC FUEL PUMPS P/N , , & FUEL PRESSURE REGULATOR P/N

Not required for most applications. Not required for most applications. High pressure ( provided) High pressure ( provided)

Whale - Electric Bilge Pump Range From the Experts in Bilge Pumps experience in electronics

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

08 general Purpose Pumps

Operating and Installation Instructions

Sinking of Nordhavn 75 hull #2

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6

STEP-BY-STEP INSTALLATION GUIDE

FUEL KITS P/N & 526-2

BSS Examination Record Form for Privately Owned and Managed Vessels

User s Manual. Automatic Switch-Mode Battery Charger

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

OPERATION MANUAL, POWER MODULE-CHARGER SYSTEM. Man Occup. Machine Occup. Cycle Time Setup Time Batch Qty. Equipment Manufacturer Qty

Fuel Systems GASOLINE FUEL SYSTEMS

DOMINATOR FUEL PUMPS P/N & Installation Instructions 199R10573

Installation Manual. English. French

Installation instruction

Rev: Flow Max 115V AC Fluid Pump

Sniper EFI Fuel Kits P/N 526-5/526-8 (20 ft. hose) & (40 ft. hose)

Flojet Rewrites the Book on Small Pump Control

FUEL KITS P/N & 526-4

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

Toilet Systems - Introduction. Option 1 Option 2. Option 3 Option 4

UltraSystem Series II INSTALLATION MANUAL PARTNERED WITH

Voltmaster Centrifugal Trash Pumps

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

BEAMER MODEL VDC Spotlight with joystick control panel MODEL VDC Spot/flood light with joystick control panel

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

IMPORTANT INFORMATION

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

PI1500X Power Inverter User s Manual

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

ICOMIA Global Conformity Guideline for ISO and ABYC Standards. Guideline Number 1 Installed Fuel Systems and Fixed Fuel Tanks

Opening and Closing TABLE OF CONTENTS

Todd Gas Caddy Assembly Instructions

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Installation Operation Parts

ISO INTERNATIONAL STANDARD. Small craft Permanently installed fuel systems. Petits navires Systèmes à carburant installés à demeure

Toilet Systems - Introduction

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

Installation Instructions and Owner s Manual

PARTS & SERVICE Manual for PANORAMA ROTISSERIE Model SP-7

HP FUEL PUMPS P/N & Installation Instructions 199R10569

IS7.6 INSTALLATION MANUAL

Instruction Manual. Johnson Ultra Ballast Pump. Johnson Pumps

Electric Trolling Motor

OWNER S GUIDE & INSTALLATION INSTRUCTIONS

Todd Evacuation Caddy

KIT CONTENTS. Multimeter or test light Wire crimpers or soldering equipment. Wire terminals & connectors 10A inline fuse

INSTALLATION MANUAL. Power-Pole Blade Edition Shallow Water Anchor. Installation Instructions

Self-Leveling Rotary Laser Level with GreenBrite Technology Model No Instruction Manual

Model 3051 Sensor Module Replacement

T1-Titanium Non-HVLP Spray Gun

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

part three electrical installations

255 Liter/Hr, In Tank Fuel Pump For Chrysler Front Wheel Drive Vehicles Catalog # INSTALLATION INSTRUCTIONS

MODEL CJ-95 CoilJet Portable HVAC Coil Cleaning System

Installation Instructions for Load Management Kit A051C329

Brake master cylinder with 25.4 mm (0.999 in.) diameter piston and brake servo, component summary

OWNER S GUIDE & INSTALLATION INSTRUCTIONS

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

PB18 SERIES PORTABLE PUMPS

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

SIGNETMARINE. Livewell Bait Pump Alarm. No Dead Bait.

PART 8 MACHINERY INSTALLATIONS

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine

BP3000 / BP3010 / BP3020

HP FUEL PUMPS P/N ERL & ERL Installation Instructions 199R11108

D Instructions/Parts. Siphon Feed Detail Spray Gun D

A/C-D/C Battery Backup Sump Pump System

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

MODEL H INSTALLATION INSTRUCTIONS

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

1100W PORTABLE GENERATOR

6.4L EGR Delete With Intake Elbow

5. FUEL SYSTEM 5-0 FUEL SYSTEM UXV 500

MODELS: SPL-12W, SPL-12B, SPL-12C IMPORTANT! READ THESE INSTRUCTIONS BEFORE INSTALLING AND USING THIS PRODUCT.

INSTALLATION MANUAL IM1000

SERVICE & OWNER S MANUAL

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Installation Manual. TRACKERmarine Genset Series 4000 KY. Printed in U. S. A. 8-95

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Transcription:

Fully Automatic Bilge Pump INSTRUCTION MANUAL

Purpose of this manual The purpose of this manual is to provide necessary information for product installation, operation and maintenance. CAUTION: Read this manual carefully before installing, using or servicing this product. Failure to follow the instructions within this manual could result in explosion, property damage, severe personal injury and/or death. User safety General safety rules. These are safety rules that apply: Always keep work area clean Pay attention to the risks presented by gas and vapors in the work area. Avoid all electrical dangers. Pay attention to the risks of electric shock or arc flash hazards Always bear in mind the risk of drowning, electrical accidents and burn injuries DANGER: This product is not intended for damage control or to deal with flooding resulting from hull damage. This product is intended to be used in Bilge Pumping Systems for small craft with a hull length up to 24 meters, as described within the introduction and scope of ISO 15083. Bilge Pumping Systems, as specified in ISO 15083, are limited to normal amounts of water in an intact boat due to spray, rain, seepage, spillage, and occasional small amounts of water shipped from boat movements in heavy weather. Use of product in any other way could result in flooding, catastrophic damage to craft, serious personal injury, or death. WARNING: This pump is designed for use with fresh water and salt water ONLY. Use with any other hazardous, caustic, or corrosive material could result in damage to the pump and the surrounding environment, possible exposure to hazardous substances and injury. 2

Bilge pumps shall be mounted in accordance with the pump manufacturer instructions, and in an accessible location to permit servicing and cleaning of the intake and/or screening. On boats with an enclosed accommodation compartment, an audible alarm shall be installed indicting that the bilge water is approaching the maximum bilge water level. Bulkhead penetrations shall be in accordance with the requirements of ABYC H-2, Ventilation of Boats Using Gasoline, to minimize the potential for migration of carbon monoxide from machinery compartments containing gasoline engines to adjacent accommodation compartments. Potential electrical sources of ignition located in spaces containing gasoline powered machinery, or gasoline fuel tank(s), or joint fitting(s), or other connection(s) between components of a gasoline system, shall be ignition protected, unless the component is isolated from a gasoline fuel source as described in ABYC E-11.5.3.3 Exception: 1. Boats using diesel fuel as the only fuel source. 2. Outboard engines mounted externally or in compartments open to the atmosphere in accordance with the requirements of ABYC H-2, Ventilation of Boats Using Gasoline. The bilge pump inlet shall be located so that excess bilge water can be removed from the bilge at static floating position, and at maximum conditions created by the boat s motion, heel, and trim. Electrical Disconnect power before installing or servicing the pump. Our pump is equipped with silicone blocked, tin coated 16 gauge wire. Please follow the table below when extending the wires. Wire Size Table Total Wire Length (positive to pump) - feet (meters) 0-15 ft 15-20 ft 20-30 ft 30-60 ft 60-90 ft 0-4.5 m (4.5-6 m) (6-9 m) (9-18 m) (18-27 m) 16 AWG 14 AWG 12 AWG 10 AWG 8 AWG (1.5 mm 2 ) (2.5 mm 2 ) (4 mm 2 ) (6 mm 2 ) (10 mm 2 ) This pump must be fused with a 7.5 amp fuse (not included). All potential sources of ignition located in spaces containing gasoline powered machinery or gasoline fuel tank(s), or joint fitting(s), or other connection(s), between components of a gasoline system, shall be ignition protected in accordance with the requirements of ABYC E-11, AC and DC Electrical Systems On Boats. The electrical wiring, connections, and installation shall be in accordance with the requirements of ABYC E-11, AC and DC Electrical Systems On Boats. The following is a summary of typical wiring installations: Hold finger over black dot for five seconds to test pump Brown wire Brown/white wire Black wire Automatic Manual override Ground Brown-Automatic 7.5 Amp Fuse Three position switch Brown/white-Manual ON-OFF -Auto Switch + Black-Ground 3

Brown-Automatic 7.5 Amp Fuse Two position switch ON-OFF Switch + Brown/white-Manual Black-Ground 7.5 Amp Fuse No switch Brown-Automatic Brown/white-Manual Seal closed + Black-Ground Pumps with automatic controls shall be provided with a visual indication that power is being supplied to the pump. Pump will cycle every 2.5 minutes to sense for water. Water will reach approx 1.3 (3.3 cm). Good for shallow bilges and small compartments. To change from Low to High sensor setting, unlock the motor cartridge by turning counter-clockwise. Turn the cartridge 180º until the H is on top and reinsert the motor cartridge. Turn the motor clockwise to lock. Water will reach approx 2 (5 cm). Good for shower boxes, very wet areas, narrow bilges. 4

Installation: We recommend using #8 Stainless Steel screws of an adequate length as to secure the pump but not penetrate the entire thickness of the hull. Use a flexible sealant in the screw holes to prevent water from penetrating the screw holes. Screws Disassembly and reassembly Best practice: Periodically clean the sensor housing with a mild detergent to remove any build-up that may interfere with the proper operation of the bilge pump. If the sensor accumulates excessive build-up, the pump will enter the timer mode to protect the pump and the vessels batteries. Once the debris is removed, the pump will return to level sense mode. 5

Plumbing: This bilge pump has been designed to be used with flexible hose. Rigid piping or tubing may damage the pump or the pump s discharge. Factors that reduce the flow of a bilge pump may include but are not limited to the following: The length of discharge piping (longer runs reduce flow) The number or radius of bends The roughness of the interior surfaces of piping and fittings (smooth bore hose is best) The reduction (hose restriction) in cross-sectional area of discharge system components such as check valves and thru-hulls Attach the discharge hose to the hose barb using stainless steel hose clamps. The thru-hull discharge fitting should be mounted at least 8 (20.3 cm) above the heeled water line to prevent water siphoning in from outside the vessel or the discharge may be located below the maximum heeled waterline if the discharge line is provided with both of the following: A seacock installed in accordance with the requirements of ABYC H-27, Seacocks, Thru-Hull Connections, and Drain Plugs, and A vented loop or other means to prevent siphoning into the boat. A check valve shall not be used for this purpose. If the discharges of several pumps are manifolded to discharge through a single thru-hull fitting, the system shall be designed so that the operation of one pump will not back feed another pump, and the simultaneous operation of each pump will not diminish the pumping capacity of the system. A check valve shall not be used in the discharge manifold system. A check valve may be used only when necessary to prevent an automatic bilge pump from cycling on and off due to back flow from the discharge line. Hose connections shall be secured with a non-corrosive type of clamp, or be mechanically fastened with permanentlyattached end fittings, such as swaged sleeve. Threaded inserts shall be attached with corrosion resistant metallic clamps. Best practice: Use two stainless steel hose clamps to attach hose to hose barb. During the winterization of a vessel, it s recommended that you remove the check valve (if equipped) and drain any residual water from the plumbing. Please note that the check valve should NOT be used with the elbow fitting. The check valve and elbow combination greatly restrict the flow. 6

Dimensional Drawing 5.9"/15.0cm 8.9"/22.6cm 3"/7.6cm 2.4"/6.1cm 3"/7.6cm Mounting Holes 2.35"/5.9cm 4.86"/12.3cm 2.4"/6.1cm 1.8"/4.5cm Mounting Holes Flow Curves 14 12 Performance at 12.0 Volts 1-1/8" Adapter 1" Adapter 3/4" Adapter 10 Head (Ft H20) 8 6 4 2 0 0 100 200 300 400 500 600 700 800 900 Flow (GPH) 7