Inductive voltage transformers

Similar documents
Inductive voltage transformers

Inductive voltage transformers

Inductive voltage transformers

Combined instrument transformers

Inductive voltage transformers

Inductive voltage transformers

Inductive voltage transformers

Combined instrument transformers

Current transformers. Outdoor operation SF 6 -gas insulated. JGF ( ) kv

Cable current transformers

High-current Transformers

DM Condenser bushings, kV DURESCA

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

Transformer bushings, type GOH. Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

B kv Gas-insulated Substations

Power Voltage Transformers for Air Insulated Substations

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Volt Instrument Transformers

Transformer Bushings Type COT COT kv to 245 kv up to 3150 A IEC 137

CP Automatic capacitor bank

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

EMPAC Metal enclosed capacitor bank for wind applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Step 1: Collection of required data

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

3 TM Cold Applied Barrier Boot System

Transformer bushings, type GOA 250. Installation and maintenance guide

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

GAS INSULATED VOLTAGE TRANSFORMERS.

Bushings for High Voltage AC Applications

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

2. INDUCTIVE VOLTAGE TRANSFORMERS Dry and oil-paper insulation

Distribution transformers Efficiency over life-cycle

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Product brochure. Gas-insulated switchgear ELK-4, 800 kv Pioneering technology for extra-high voltage applications

kv А

Transformer bushings, type GSA-OA Technical guide

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Kuhlman Electric Corporation Volt Instrument Transformers

BUSHINGS: GENERAL INFORMATION

PABS. AIR-TO-SF 6 - Gas-insulated bushing IEC STANDARDS ANSI STANDARDS AN ALSTOM COMPANY

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS

PHOENIX CONTACT

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Combined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications

Completing the picture

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

OTAA Oil Impregnated Paper (OIP) Bushing for IEEE/ANSI Market

Current accuracy class. Sensor principles

power cable accessories

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Medium Voltage Capacitors

Compact Integrated Distribution Substation (CIDS)

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide

K50H004UP cam changeover switch - 4-pole A - screw mounting

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

CBGS-0. Medium voltage distribution

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

CPG.0 Single busbar gas-insulated cubicles

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

K30H001YP cam star-delta switch - 3-pole A - screw mounting

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Single-phase CT current transformers Cat. Nos :

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

Key features. DESIGNS: - Conservator type - Hermetically sealed

ZX2 Gas-insulated medium voltage switchgear

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

B kv T&D GAS INSULATED SWITCHGEAR

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

MEDIUM VOLTAGE SWITCHGEAR

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3. 2 Technical Perticular for Capacitor Unit 4. 3 MV Surge Capacitor Unit Drawings 6

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

NXPLUS C Single busbar. Maintenance-free for lifetime

Electronic overload relays EF205 and EF370

Transcription:

Inductive voltage transformers Outdoor operation Oil-paper insulated EOF (24 245) kv

General description Voltage transformers type EOF are used in high voltage networks within the 24 245 kv range. They transform high voltage into standardised values for meters, measuring and protection devices. The active part of the voltage transformer is located in the foot housing. The high voltage insulation is implemented in oil-paper technology. To achieve this, a high quality PCB-free mineral oil is used. The fine graded bushing is inside the insulator. The expansion system is located in the head of the voltage transformer. This unit acts as volume compensation for the oil in case of temperature variations. For voltage transformers of 24 72 kv, a highly flexible, temperature-resistant membrane made from fluoroelastomers (VITON ) is used. Voltage transformers > 72 kv have an expansion cell made of stainless steel. The oil level is indicated by a mechanical system in the window of the bellows cover. All metal housings and flanges are made from a special aluminium alloy. These parts can be colour coated on request. All voltage transformers have either a high-quality porcelain or a high-grade silicone composite insulator. Different creepage distances are available according to the different pollution classes, as specified in the standards. The hermetic sealed housing protects the oil-paper insulation against atmospheric influences. The generously sized terminal box has a cover which can be opened sidewards. This allows easy connection of the secondary cables. The terminal box has a flange without holes by default. Cable glands, circuit diagram and individual safety instructions can be preinstalled on request. Advantages of inductive voltage transformers Protection of the secondary winding from transient overvoltages in the high-voltage network through capacitively coupled shielding Protection against occurring ferroresonance through low operating inductance in the iron core High operating safety as there are no active parts in the insulator Minimum oil volume through optimised design Ambient temperature 40... + 40 C

Highlights Fine graded bushing Excellent protection against moisture Installation-friendly terminal box The fine graded bushing is designed to ensure an optimum distribution of the electric field. The bushing is fixed in a way, that it is short-circuit-safe and secondary arcs are prevented. The inner side of the instrument transformer is protected against moisture by means of special sealing rings. All housings are designed with a drain-age area to protect the sealing surfaces of the housings against rain. This significantly reduces crevice corrosion. The housing elements are connected with special stainless steel screws. They are designed in such a way that no humidity can enter the screw hole. The generously sized terminal box with a cover that can be opened sidewards, is secured with captive screws. It can accommodate terminal blocks, fuses, additional auxiliary contacts, and sealable covers. By default, all terminal boxes have a flange without holes. Cable glands can be preinstalled on request. An additional terminal box can be supplied on request.

Design Primary connection Expansion bellows Bellows cover with oil level indicator Porcelain or silicone composite insulator Bushing Possible options Colour coated housings and flanges Primary coil with high voltage insulation Lifting lugs Housing with drainage area Secondary coil Main earth connection Oil drain valve Iron core Fuses or miniature circuit breakers (MCBs) with or without auxiliary contacts in the terminal box Pressure monitoring with auxiliary contacts Heater in the terminal box Sealable cover on terminals for billing purposes Additional terminal box Tan δ terminal for capacitance and di-electric dissipation factor measurement Sealable oil drain valve Oil drain valve (24 72 kv) Oil level indicator (123 245 kv)

Technical data 123 170 kv 24 72 kv 245 kv B A F E D C Type EOF 24 36 52 72 123 145 170 245 Standard IEC / IEEE Highest voltage for equipment kv 24 36 52 72.5 123 145 170 245 Rated power-frequency withstand voltage kv 50 70 95 140 230 275 325 460 Rated lightning impulse withstand voltage kv 125 170 250 325 550 650 750 1050 Frequency Hz 16.7 / 50 / 60 Accuracy class 0.1 3; 3P; 6P Rated thermal limiting output VA 1500 3000 Max. simultaneous burden (cl. 0.2) VA 200 300 Max. number windings 5 Type EOF 24 36 52 72 123 145 170 245 Height of unit* A inch 43.6 43.6 56.3 56.3 83.3 94.2 101.6 138.1 Height to primary terminal* B inch 40.4 40.4 53.1 53.1 77.8 88.7 96.1 126.2 Depth of unit including terminal box C inch 20.7 20.7 20.7 20.7 28.0 28.0 28.7 36.9 Depth of unit base D inch 14.2 14.2 14.2 14.2 19.7 19.7 19.7 26.0 Width of unit base E inch 14.2 14.2 14.2 14.2 20.5 20.5 20.5 26.0 Distance between screw holes at base F inch 12.2 12.2 12.2 12.2 17.7 17.7 17.7 23.6 Min. creepage distance* inch 37.4 37.4 73.2 73.2 121.3 153.5 173.0 242.5 Approximate weight* lb 253.0 253.0 275.0 275.0 671.0 726.0 737.0 770.0 * with standard composite silicone insulator, creepage distance 0.98 inch/kv

Global presence PFIFFNER Instrument Transformers Ltd 5042 Hirschthal Switzerland Phone +41 (0)62 7392828 Fax +41 (0)62 7392810 E-Mail sales@pmw.ch Internet www.pfiffner-group.com PFIFFNER Transformatör A.S. 06750 Akyurt /Ankara Turkey Phone +90 (0)31 28475521 Fax +90 (0)31 28475421 E-Mail info@pfiffner.com.tr Internet www.pfiffner.com.tr PFIFFNER do Brasil Ltda 88307-740 Itajaí Brazil Phone +55 (0)47 33481700 Fax +55 (0)47 33481700 E-Mail pfiffner@pfiffner.com.br Internet www.pfiffner.com.br PFIFFNER Deutschland GmbH 25524 Itzehoe Germany Phone +49 (0)48 21408270 Fax +49 (0)48 214082729 E-Mail sales@pfiffner-messwandler.de Internet www.pfiffner-messwandler.de MGC Moser-Glaser AG 4303 Kaiseraugst Switzerland Phone +41 (0)61 4676111 Fax +41 (0)61 4676110 E-Mail info@mgc.ch Internet www.mgc.ch ALPHA Elektrotechnik AG 2560 Nidau Switzerland Phone +41 (0)32 3328700 Fax +41 (0)32 3312679 E-Mail mail@alpha-et.ch Internet www.alpha-et.ch This document has been drawn up with the utmost care. We cannot, however, guarantee that it is entirely complete, correct or up-to-date. Copyright PFIFFNER 2015.12 Subject to change without notice. HIGH VOLTAGE Manufacturer of INSTRUMENT transformers since 1927 MEDIUM VOLTAGE LOW VOLTAGE