Pre-Installation Guide Performer

Similar documents
A-dec 311 Dental Chair and Related Systems

A-dec 200 P RE-INSTALLATION GUIDE

Instructions for Use. Cascade 2615 Cart

Assistant s Instrumentation T

Instructions for Use. A-dec 4631 Duo Delivery System and A-dec 4635 Assistant s

A-dec 300 LED Dental Light

A-dec 311, 411, and 511 Dental Chairs Service Reference

The A-dec Difference.

A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE

Instructions for Use. A-dec EA-30. Electric Motor System

INSTRUCTIONS FOR USE. A-dec 311 Dental Chair

A-dec 300 Delivery Systems

Cascade 3072 Delivery System INSTALLATION GUIDE

A-dec Stools. A-dec 1601 Doctor's Stool A-dec 1621, 1622, and 1626 Assistant's Stools

Regulatory Information and

A-dec 336 Delivery System on an A-dec 411 or 511 Dental Chair INSTALLATION GUIDE

A-dec LED Dental Light Head on a Demonstration Stand INSTALLATION GUIDE

A-dec 541 Delivery System and 545 Assistant s Instrumentation

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

A-dec O Clock Delivery System

The A-dec Difference Built for Life

The A-dec Difference Built for Life

The A-dec Difference Built for Life

A-dec 500 Delivery Systems

Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs)

A-dec 570L Dental Light on a Non-DCS System INSTALLATION GUIDE

A-dec Dental Lights on an A-dec 300 Base Mount Post INSTALLATION GUIDE

The A-dec Difference. You can count on A-dec products to work consistently so you can stay focused on what matters most: the patient.

A-dec 371L or 571L Dental Light on an A-dec 361, 362, or 363 Support Center INSTALLATION GUIDE

The A-dec Difference 5 YEAR WARRANTY. You can count on A-dec products to work consistently so you can stay focused on what matters most: the patient.

A-dec 200 Service Guide Contents

Asepsis 21 Delivery Unit

A-dec 2122/2132 Radius System on A-dec 511 Dental Chair I NSTALLATION GUIDE

A-dec 542 Side Delivery System I NSTALLATION GUIDE

Legendary A-dec Reliability

INSTALLATION MANUAL. Contour & Contour LX Pedicure Chairs. Contour. Contour LX Rev B 5/11/18

Owner s Guide PERFORMER III

Service Guide A-DEC SIMULATORS. Mobile (4810) and Stationary (4820)

DECADE 1021 SOLO CHAIR

Cascade Master Series

Instructions for Use. A-dec EA-53 Electric Motor

Owner s Manual Pelican Whole House Iron and Manganese Filtration System

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

INSTRUCTIONS FOR USE CASCADE 2615 CART AND 3175 WALL MOUNT

Owner's Guide CASCADE 2671 DUO CART AND CASCADE 3171 DUO WALL-MOUNT

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

MityFlex Peristaltic Pump

Model C230 Pump Controller

Instructions for Use. Performer. Dental Chair, Delivery System, Assistant s Instrumentation, Support Center with Cuspidor, and Light

Legendary A-dec reliability

INSTALLATION INSTRUCTIONS CASCADE 3181 DUO DELIVERY SYSTEM TO PREFERENCECOLLECTION 5580

Owner s Manual Nitrate Series Salt Based Filter System

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Dynojet Research, Inc. All Rights Reserved. Air Fuel Ratio Module Installation and User Guide.

SUPER PUMP OUT SYSTEM

Coleman Air ITS-240 Inverter Transfer Switch

( Versions Available)

Updated: October 2012

Toro Sprayer Calibration Tool

Solar-Powered Battery Bank

SUBMERSIBLE MINI-PUMP

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Surface Mounted Bottle Fillers

ELECTRICAL POWER GUIDE INTERNATIONAL EDITION

Coleman Air ITS-240 Inverter Transfer Switch

Patient Care Facility

Dynojet Research, Inc. All Rights Reserved. Tire Temperature Sensor Installation Guide

CASCADE CHAIR-MOUNTED HANDPIECE CONTROL WITH CASCADE MASTER SERIES TOUCH PAD

PRE-INSTALLATION GUIDE

Patient Care Facility

Addendum. Remote Air-Cooled Condenser

WT6000. Wearable Terminal Quick Start Guide MN

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Owner s Manual. Calcite ph Neutralizer

Installation, Operation, Repair and Parts Manual

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC)

Installation Operation Maintenance Troubleshooting Version 1, Oct/09. Palm Beach

Installation, Operating & Maintenance Instructions. Hot surfaces; do not touch!

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Power Distribution Units

Mini UHV gate valve with manual actuator with pneumatic actuator

UHV Angle valve (Series 284) with pneumatic actuator, single acting with closing spring (NC)

FENIEX ROCKER PANEL Series MODEL # D-11971

1416 Cabinet Unit. Installation Operation Maintenance Troubleshooting Version Dec/17

Rectangular Door L-VAT with pneumatic actuator double acting

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Torque Cell Installation Guide for Model 250i/250iP DynoWare RT Dynamometers.

Installation Instructions: Over-The-Patient Units (& Cuspidors) BDS-2500 BDS-2505 BDS-2510 BDS-2515 BDS-2520

Thermo Fisher Scientific (U.S. and Canada only) 11 (847) (Outside U.S.) (847) (Local)

DECADE 1021 VAC BACK CHAIR

NearBright Illuminated Near Vision Kit. User s Guide

Conductivity Sensors. Applications. 140 Series Conductivity Sensors Product Data Sheet LIQ_PDS_140_141_142_Conductivity_Sensors January 2014

DART Charger Product Description, Information and Specification

GRADE 3 TUBULAR LOCKSETS INDEX:

5-Slot and 2-Slot Panels Installation Guide

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Agilent N2763A Rack Mount Kit for 4000 X-Series Oscilloscopes

Transcription:

Pre-Installation Guide Performer Contents Structural Requirements... 1 Dental Patient Chair Interface Requirement... 1 Utility Requirements... 1 Utility Specifications... 2 Electrical Ratings... 3 Shipping Weights... 3 Documentation References... 4... 5 Plumbing Elevations... 5 Utility Placement... 5 Contoured Floor Box Utility Connections... 6 Remote Floor Box Utility Connections... 6 Performer Dental Chair... 7 Performer Front-Mount Delivery System... 8 Performer Back-Mount Delivery System... 9 Performer with A-dec 332/333 Delivery System...10 Performer Cuspidor and Support Center... 11 Performer Assistant s Instrumentation...12 Performer with Front-Mount Dental Light...13 Performer with Back-Mount Dental Light...14 Performer with Support Center Mount Dental Light...15 Performer/A-dec 381 Monitor Mount...16 A-dec 482 Monitor Mount... 17

Copyright 2018 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. A-dec Inc. shall not be held liable for any errors contained herein or any consequential or other damages concerning the furnishing, performance or use of this material. The information in this document is subject to change without notice. If you find any problems in the documentation, please report them to us in writing. A-dec Inc. does not warrant that this document is error-free. No part of this document may be copied, reproduced, altered, or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system, without prior written permission from A-dec Inc. Trademarks and Additional Intellectual Property Rights A-dec, the A-dec logo, A-dec Inspire, Cascade, Century Plus, Continental, Decade, ICX, ICV, Performer, Preference, Preference Collection, Preference ICC, Radius, and reliablecreativesolutions are trademarks of A-dec Inc. and are registered in the United States and other countries. A-dec 500, A-dec 400, A-dec 300, A-dec 200, and EasyFlex are also trademarks of A-dec Inc. None of the trademarks or trade names in this document may be reproduced, copied, or manipulated in any manner without the express, written approval of the trademark owner. Certain touchpad symbols are proprietary to A-dec Inc. Any use of these symbols, in whole or in part, without the express written consent of A-dec Inc., is strictly prohibited. Warranty and Regulatory Information The A-dec warranty and regulatory information mandated by agency requirements are provided in the Regulatory Information, Specifications, and Warranty document (p/n 86.0221.00), which is available in the Document Library at www.a-dec.com. Product Service For product questions and support, contact the authorized A-dec dealer that will be installing the equipment, or call A-dec at 1.800.547.1883 (USA/Canada) or 1.503.538.7478 (worldwide). Product Models and Versions Covered in This Document Model Versions Description Performer 8000 B Dental Chair Performer 8100 B Delivery System 332, 333 A Delivery System Performer 8200 B Support Center and Cuspidor Performer 8500 B Assistant s Instrumentation 571, 572, 371L, 372L, 571L, 572L A Dental Light Performer 8800 B Monitor Mount 381, 482 A Monitor Mount

Structural Requirements Structural Requirements NOTE Job site construction should be completed before the dental equipment installation (including finished floors, ceiling, plumbing, lighting, paint, etc.). Dental Patient Chair Interface Requirement The dental chair requires a solid, level mounting surface that meets these minimum specifications: Weight of 1000 lb (4448 N) for the chair, dental light, delivery system, and patient. Capability to anchor the chair to the floor, with a minimum pullout load of 100 lb (445 N) for one anchor-bolt. Utility Requirements CAUTION Local regulation may require licensed plumbers and electricians to install the utilities. All plumbing and utilities must conform to prevailing local codes. CAUTION The manner and method for accessing the utilities within the wall is the responsibility of the design team working on the project (dental dealer, architectural services, and contractors). Utilities must be accessible without the use of tools. 1

Structural Requirements Utility Specifications NOTE Use only full-scale templates for locating the plumbing and electrical. Utility Finish Requirements Air Water* Central vacuum Gravity drain** Electrical Protrude 2" (51 mm) for 1/2" (13 mm) compression Protrude 2" (51 mm) for 1/2" (13 mm) compression Protrude 1" (25 mm) for 5/8" (16 mm) O.D. tubing and other specified by the central vacuum supplier Protrude 1" (25 mm) for 1-1/2" (38 mm) nominal pipe 1/2" (13 mm) conduit and box with a hospital-grade power receptacle Right-angle manual shutoff valve supplied and installed by the contractor. 80-125 psi (550 to 860 kpa), 2.5 scfm (71 SL/min) minimum, during normal use (7.5 scfm [210 SL/min] peak intermittent flow). Flush lines prior to making connections to dental equipment. Right-angle manual shutoff valve supplied and installed by the contractor. 60 ± 20 psi (410 ± 140 kpa), 1.5 gpm (5.7 L/min) minimum, not to exceed 40 C (104 F). Flush lines prior to making connections to dental equipment. Wet systems: 10 ± 2 inches of Hg (34 ± 7 kpa) and 9 scfm (255 SL/min) minimum. Dry/semi-dry systems: 4.5 ± 1 inches of Hg (16 ± 3.5 kpa), 12 scfm (340 SL/min) minimum. Place trap in line, conforming to local codes, contractor-supplied. Waste water drain must have a minimum slope of 1/4" per foot (21 mm per meter), and sized to prevent full-bore flow with a discharge rate of 5.1 fl oz/sec (150 ml/sec). Floor mount only. Not recommended for wall mount utilities. Wire box per code. Top of the receptacle should not be higher than 5" (127 mm) above finished floor for fit within floor box. See the Electrical Ratings table for voltage and amperage ratings. * The delivery system comes with a self-contained water bottle. Municipal water is only required if the equipment configuration includes a cuspidor or if the facility has special requirements. ** Gravity drains are needed only on systems with a cuspidor. 2

Shipping Weights Electrical Ratings Chair Type Required Electrical Supply Amperage Rating Amperage Breakdown 240 Volt Chair 220 240 VAC, 50 60 Hz, 10 Amps minimum 120 Volt Chair 110 120 VAC, 50 60 Hz, 15 Amps minimum (20 Amps recommended) 10 Amps maximum 240 VAC @ 50 60 Hz: 2 Amps chair pump motor 1.4 Amps 300-watt power supply 2 Amps ancillary products 10 Amps maximum 120 VAC @ 50 60 Hz: 3.5 Amps chair pump motor 2.5 Amps 300-watt power supply 2 Amps ancillary products Shipping Weights Product/Box Performer Dental Chair Performer Delivery System A-dec 332/333 Delivery System Performer Cuspidor and Support Center Performer Assistant s Instrumentation A-dec 371L/571/571L Dental Light A-dec 372L/572/572L Dental Light Performer Monitor Mount A-dec 381 Monitor Mount A-dec 482 Monitor Mount Estimated Shipping Weight 302 lb (137.0 kg) 57 lb (25.9 kg) 88 lb (40.0 kg) 64 lb (29.0 kg) 19 lb (8.6 kg) 35 lb (15.9 kg) 47 lb (21.3 kg) 7 lb (3.2 kg) 9 lb (4.1 kg) 11 lb (5.0 kg) 3

Documentation References Documentation References Document Title Part Number Installation Guides A-dec Performer Dental Chair with Delivery System, Dental Light, and Support Center Installation Guide 86.0556.00 A dec Performer Monitor Mount on an A dec Performer, 571, 572, 571L, or 572L Dental Light Installation Guide 86.0628.00 Service Guide and Reference A-dec Performer Service Guide 86.0606.00 A-dec Performer Service Reference 86.0610.00 Instructions for Use Performer Instructions for Use 86.0593.00 Regulatory Information, Specifications, and Warranty 86.0221.00 Templates A-dec Performer (Version B) Dental Chair Template 86.0640.00 A-dec Performer (Version B) Dental Chair Mini Template 86.0641.00 A-dec Performer (Version B) Dental Chair Related Modules Template 86.0642.00 4

NOTE The dimensional drawings in this section are not to scale and are for reference only. For complete accuracy, use the appropriate full-sized templates. Utility Placement CAUTION Due to specific plumbing elevation restrictions, the height and placement of utilities in the floor box can affect the ability to use the floor box cover. Failure to provide adequate space will prevent installation and removal of the cover. See Plumbing Elevations. Please reference the appropriate full-size template which includes all of the necessary space constraints. Plumbing Elevations 5/8" (16 mm) O.D. tubing for Wet systems. 40 mm O.D. tubing for Dry/Semi-Dry systems. Central Vacuum Only (see general notes). 1-1/2" (38 mm) nominal pipe for Gravity Drain (when required) 2" (51 mm) 1" (25 mm) 1" (25 mm) finish stub height 5" (127 mm) max. height FLOOR SURFACE FLOOR SURFACE 1/2" (13 mm) nominal pipe compression fitting with right angle manual shut-off valves for Air & Water. 1/2" (13 mm) conduit for electrical. Supplied by contractor. (check amperage requirements) 5

NOTE Use only full-scale templates for locating the plumbing and electrical. Contoured Floor Box Utility Connections Remote Floor Box Utility Connections 432 mm (17 ) 248 mm (9.75 ) 178 mm (7 ) 384 mm (15 ) Width of Floor Box Cover Frame UMBILICAL ENTRANCE 189 mm (7.5") Optional 2" DATA CONDUIT (Locate as Needed) 38 mm (1.5 ) Nominal Pipe for Gravity Drain (when required) LC Hospital-Grade Quad Electric Box Supplied by Contractor 44 mm (1.75 ) 13 mm (0.5 ) Electrical 51 mm (2") 485 mm (19") 65 mm (2.5 ) Water Vacuum Air 57 mm (2.25 ) 32 mm (1.25 ) 76 mm (3 ) 54 mm (2.25 ) 54 mm (2.25 ) 133 mm (5.25 ) Optional 2" Dia. Umbilical Entrance Optional 51 mm (2 ) DATA CONDUIT (locate as needed) Umbilical Entrance Optional 2" Dia. Umbilical Entrance AIR VACUUM 5/8" O.D. (16 mm) Tubing For Central Vacuum Only (see General Utility Notes) 38 mm (1.5 ) Nominal Pipe for Gravity Drain (when required) DRAIN WATER Hospital- Grade Quad Electrical Box Supplied by Contractor ELECTRICAL LC 3/4" (19 mm) 368 mm (14.5 ) 6

Performer Dental Chair Plan View with Elevation 1956 mm (77") 165 mm (6.5") Range of Headrest 630 mm (24.75") 165 mm (6.5") Range of Headrest 199 mm (7.75 ) 2156 mm (84.75") 165 mm (6.5") Range of Headrest 856 mm (33.75") 1791 mm (70.5") 1486 mm (58.5") 47 mm (1.75") 6" Forward Chair Travel (base down to base up) 152 mm (6") Forward Chair Travel (base down to base up) 679 mm (26.75") 856 mm (33.75") 7

Performer Front-Mount Delivery System Plan View with Elevation 423 mm (16.75") 628 mm (24.75") 753 mm (29.5") 165 mm (6.5") Range of Headrest 2002 mm (78.75") 152 mm (6") Forward Chair Travel Full Base Down to Full Base Up 8

Performer Back-Mount Delivery System Plan View with Elevation 423 mm (16.75") 753 mm (29.5") 628 mm (24.75") 757 mm (29.75") 1233 mm (48.5") 9

Performer with A-dec 332/333 Delivery System Plan View with Elevation NOTE This configuration is not available in all countries. (A-dec 332 Shown) 423 mm (16.625") 973 mm (38.25") 781 mm 30.75" 2032 mm (80") 152 mm (6") Forward Chair Travel Full Base Down to Full Base Up 10

Performer Cuspidor and Support Center Plan View with Elevation 45 866 mm (34") 603 mm (23.75") 683 mm (26.75") 1372 mm (54") 11

Performer Assistant s Instrumentation Plan View with Elevation 541 mm (21.3") 204 mm (8") 655 mm (25.75") 1341 mm (52.75") 12

Performer with Front-Mount Dental Light Plan View with Elevation (A-dec 572L Dental Light Shown) 700 mm (27.5") 911 mm (35.75") 27" (686 mm) A-dec 572L Dental Light 1956 mm - 2286 mm (77" - 90") 743 mm (29.25") A-dec 572 Dental Light 1988 mm (78.25") 152 mm (6") Forward Chair Travel Full Base Down to Full Base Up A-dec 372L Dental Light 13

Performer with Back-Mount Dental Light Plan View with Elevation (A-dec 572L Dental Light Shown) 700 mm (27.5") 911 mm (35.75") A-dec 572L Dental Light 27" (686 mm) 1956 mm - 2286 mm (77" - 90") 743 mm (29.25") A-dec 572 Dental Light 641 mm (25.25") 1233 mm (48.5") A-dec 372L Dental Light 14

Performer with Support Center Mount Dental Light Plan View with Elevation (A-dec 571L Dental Light Shown) 718 mm (28.25") 27" (686 mm) A-dec 571L Dental Light 911 mm (35.75") 1956 mm - 2286 mm (77" - 90") A-dec 571 Dental Light A-dec 371L Dental Light 15

Performer/A-dec 381 Monitor Mount Plan View 260 mm (10.25") 743 mm (29.25") 260 mm (10.25") 16

A-dec 482 Monitor Mount Plan View 465 mm (18.25") 260 mm (10.25") 743 mm (29.25") 465 mm (18.25") 260 mm (10.25") 17

A-dec Headquarters, 2601 Crestview Drive, Newberg, Oregon 97132, USA Tel: 1.800.547.1883 Within USA/Canada, Tel: +1.503.538.7478 Outside USA/Canada www.a-dec.com A-dec Inc. makes no warranty of any kind with regard to the content in this document including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Copyright 2018 A-dec Inc. All rights reserved.