SEC. SEC America, LLC. Model 680 CE, DC-DC Converter Owner's Manual

Similar documents
SEC. SEC America, LLC. Model 7048 DC-DC Converter Rev 1 Owner's Manual

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

VTC610 Series Voltage Converter. Installation & Operation Manual

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

VTC1000 Series Voltage Converter. Installation & Operation Manual

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

DC to DC Step Up Converter Model: VTC305

DC REGULATED POWER SUPPLY

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

WF-5110R True Sine Wave Inverter

SUREFIRE 512 STOVE SENTRY INSTRUCTION MANUAL

RU BMS Power Supply and Battery Management System Owners Guide

3-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

Airpax Dimensions, Inc.

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

Integrated Back-up Battery System

Boston Gear Ratiotrol DC Motor Speed Control

5-Channel Power Amplifier. User s Manual. Version 1 MODERN SOUND FOR YOUR CLASSIC.

DC to AC Power Inverters

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

A Member of the. Integrated Metering Technologies

Safety-TrimTM. Dual axis servo controller. with 2 speed presets

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

RESISTIVITY MONITOR/CONTROLLERS

3V SERIES SOLENOID VALVE

American Power Design, Inc.

Patient Care Facility

American Power Design, Inc.

Intelligent Flap Controller

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Patient Care Facility

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

DC to AC Power Inverters

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

MSD Kawasaki Jet Ski 750 Enhancer CD Ignition PN 4251

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

BL7000 SYSTEM OPERATING MANUAL

ADI-125/750 ADI-125/1500 ADI-125/2500

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

COMPRESSED AIR LOADER MODEL: AL-1

WF-5110R True Sine Wave Inverter

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Infinitybox Express Road Race Car Kit Installation Guide

BROMAN MODEL 123XL PORTABLE LOAD BOX. Series 2

ESD5500E Series Speed Control Unit

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company


Rapid Shrink 100. Owner s Manual

Diagram D Parts of the Fuel Level Sender Unit to be Adjusted

24V Supply Operation & Specifications Manual. Field Tools. General Description

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

ZoneZ Lite Quick Start Guide

Installation & Operation Manual PWS1000R Rack Mount Power Supply

High Frequency SineWave Guardian TM

Installation Instructions Central Battery Units

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

OWNERS MANUAL JANUARY 2007 ISO

DYNAMOMETER CONTROLLER MODEL 5220 INSTRUCTION AND REFERENCE MANUAL

ESC2301. Universal Electronic Governor Controller Operation Manual

4V130P-430P SERIES AIR PILOT VALVE

Boston Gear Ratiotrol DC Motor Speed Control

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

MODEL 422 Submersible Pump Controller

Item no Smart AC 200 USB. User s Manual

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

EE30181A DC Electronic Load 300 Watt

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

A5000GEC-24VDC ZERO SPEED SWITCH

Model Number Structure

Deluxe ASA Halogen Spot/Flood Light

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Installation of TPS-28D Universal Lighting Power Supply

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

& r"1aintef~ance. Your KENBAK-l computer is a quality instrument which is. should expect months or years of operation without significant

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

Installation Instructions for the Lingenfelter TBRC-001 Temperature Based Relay Controller

Using Your SMT Micro Anodizer 0-120VDC/0-1A

Transceiver Voltage Conditioner

Activator 282 Aircraft Battery Maintenance Charger Operator Manual

INSTALLATION AND OPERATIONS MANUAL POWER OPERATED TUBING STORAGE REEL MODEL TSR-P PRODUCTS, INC.

Transcription:

SEC SEC America, LLC Model 680 CE, DC-DC Converter Owner's Manual April 15, 2010

TABLE OF CONTENTS page I Introduction 1 II Installation 1 2.1 Mounting 1 2.2 Connections 1 2.3 Methods of Converter Activation 2 III Internal Adjustments 3 3.1 Voltage Adjustment 3 3.2 Low Voltage Cutout 4 IV Warranty 5,6 V Mechanical Drawing of Base Plate 7 VI Electrical Specifications 8

I Introduction Model 680CE is shipped in fully assembled form. After removing the unit from its packaging and ensuring that it has suffered no damage in shipment, it is important to read this manual and follow its instructions to ensure proper connection and mounting. Model 680CE is a high power 12 Volt to 24 Volt DC-DC converter capable of delivering 40A to its load. It is designed for mounting in vehicles of all types and is capable of enduring harsh vibration and shock conditions II Installation 2.1 Mounting Model 680CE has an overall length of 13.8 inches with mounting flanges included in this dimension. Hole mounting centers are 13.3 x 3.93 (inches) 2.2 Connections Tools Required - 1 flat blade screw driver (1/4 in. wide) Figure 1 shows the connection panel view of the 680CE. The 680 CE, DC-DC Converter can be activated by: 1) Connecting Terminals 1 & 2 on TBA (as factory supplied) OR 2) By disconnecting Terminal 1 from Terminal 2 on TBA and connecting terminal 1 to 12 VDC through an ignition switch Activity Light TBA, 1 - enable / ignition TBA, 2-12 VDC aux. TBA Circuit breakers 50 50 1 2 TBB Input 12 VDC Common Ground Output 24 VDC 1 2 3 1 2 Figure 1 Page 1

Prior to Main Input Power Connections: Prior to hook up to the vehicular power source, the buttons on the two circuit breakers shown in Figure 1 should be pulled out into the disconnect position. This position is indicated by the exposure of the white portion of the breaker button shaft. This ensures that there is no sparking from the source of power and also allows a reprieve in case there is a hook up error. (User should carefully review connections as such an error would have to be detected prior to energizing the unit). Once the breaker buttons are pulled, proceed to make connections as follows: A) Connect input +12V line to position #1 of TBB. B) Connect input 12V ground to position #2 of TBB. C) Connect output +24 V line to position #3 of TBB. D) Connect output 24 V ground to position #2 either at the Terminal block or other convenient junction. Prior to depressing the circuit breaker buttons, installer should: 1) Ensure that hook up in steps A through D is correct. 2) Select the suitable method of converter activation. 2.3 Methods of Converter Activation A) Connect terminal #1 to terminal #2 on terminal block TBA. The 680CE is so configured when shipped from the factory. This configuration allows for converter activation by either turning the source power ON and OFF or by using the circuit breakers 1 and 2 of the 680CE for achieving this. Once the converter has been installed correctly, it is sufficient to use only circuit breaker in position #1 to energize and deactivate the converter 680CE. B) The converter can be switched from the vehicle s ignition system. For this method, remove the shorting jumper between terminals #1 and #2 on TBA and connect terminal 1 to the ignition switch or other switch that can enable terminal 1 to access 12 VDC. C) Terminal #1 can be connected to terminal #2 through a remote ON/OFF switch and thereby activating the converter. Page 2

III Internal Adjustments Varying the adjustments of the Model 680CE require the technician to have a stable DC power supply variable from at least 10 VDC to 15 VDC. To access adjustments turn the unit upside down and remove the base plate by unscrewing the 4 securing screws in its corners. (See drawing 63-1448, p 6). Orient the converter upside down and horizontally with the connection panel to the left as shown in figure #2. Main Terminal Block Cutout Adj. (A) Potted Module Vadj. (B) Bottom View Two potentiometers (A) and (B) can be noticed. Potentiometer (A) is used to adjust the converter s low voltage cutout point. This point corresponds to the minimum input voltage necessary to keep the converter ON (maintaining approximately 26V at the output). When the converter is in the OFF state, the output voltage approximately equals the input voltage. Potentiometer (B) is used to adjust output voltage. 3.1) Voltage Adjustment a) Hook up the unit to be adjusted as shown in Figure #3 under no load conditions: Activity Light TBA, 1 - enable / ignition TBA, 2-12 VDC aux. TBA 50 Circuit breakers 50 1 2 TBB Input Common 12 VDC Ground 1 2 3 Output 24 VDC 1 2 Figure #3 Power Supply +12V +24 V DVM b) Make sure terminals 1 & 2 on TBA are shorted and that the Power supply is turned off. Set the Digital Volt Meter to the appropriate scale to read 24 VDC to two decimals. c) Energize power supply and adjust its output voltage to +12 VDC. Adjust Potentiometer (B) to the desired setting (between 24 VDC and 28 VDC) and observe converter voltage output reading on DVM d) Turn off power supply. Page 3

3.2) Low Input Voltage Cutout Adjustment The Model 680CE is provided with a circuit to protect against destructively deep battery discharges, or discharges beyond the point where the vehicle battery can no longer support ignition. 680CE s are adjusted at the factory to the minimum low input voltage cutout (LIVC) of 10.8 V below which the converter remains inactive. The low input voltage cutout (LIVC) may be readjusted to another level using the test circuit in Figure #4. The LIVC functions such that when the vehicle voltage is drawn below the LIVC, the converter shuts off and becomes dormant as the activity light extinguishes. In this state the converter will feed its input voltage to its output. When in this state, in the event that a voltage equal to or higher than the converter input should be superimposed on the output (e.g. a 24V battery bank) the output configuration of the converter will prevent current from back feeding by presenting an extremely high output impedance. An audible click can be heard and the activity light extinguishes as the LIVC circuit turns off the converter. Its output voltage can be measured to drop from its normal output voltage setting to approximately the source input voltage. The range of LIVC adjustment is 10.8 to 13.0 VDC. The LVC adjustment set up is as shown in Figure #4. Unit Under Adjustment 50 50 Activity Light Circuit breakers 1 2 TBB Input 12 VDC TBA, 1 - enable / ignition TBA, 2-12 VDC aux. TBA Common urn Output 24 VDC 1 2 3 1 2 Read Input Cutout DVM 1 Power Supply +12V R1 R1 = 100 ohm, 10W Load Resistor Read Output +24 V DVM 2 Figure #4 a) Turn pot (A) completely clock wise b) Activate converter by turning on the power supply and setting it to the desired cutout voltage c) Very gradually turn pot (A) counter clockwise until simultaneously a click can be heard and the activity light extinguishes accompanied by a drop in the reading on the DVM 2. d) Adjustment is over. There is approximately 0.8 Volt of Hysteresis between the cutout and turn on voltages of Model 680CE. e.g. if 11 VDC is selected for cutout, that unit will turn back on when an input of at least 11.8 Volts is reapplied. This design serves to prevent rapid fluttering as battery voltage recovers with load removal. Page 4

IV Warranty and Repair Should your investigations indicate that your new Model 680CE is defective or damaged and your unit is still under warranty then contact SEC America, LLC at 802-865-8388 and obtain return merchandise authorization for credit or exchange. If the warranty period has expired or if the warranty has been violated due to operator error or misuse, then call : SEC America, LLC, Repair Department, at 802-865-8388 or fax SEC America, LLC at 802-865-8389 to receive authorization for shipment back to factory for a survey and possible repair. Warranty The Model 680CE has a 1 year warranty covering parts and labor. The warranty is found below: LIMITED WARRANTY We warrant each instrument, sold by us, or our authorized agents, to be free from defects in material and workmanship and that it will perform within applicable specifications for a period of one year after original shipment. Our obligation under this guarantee is limited to repairing or replacing any instrument or any part thereof,except fuses and pilot lights, which shall within one year after delivery to the original purchaser, be returned to us with transportation charges prepaid, prove after our examination to be thus defective. The above limited warranties take the place of all other warranties, expressed or implied, and correction of such defects by replacement or repair shall constitute a fulfillment of all obligations under the terms of the warranties. The warranties do not cover any unit that has been damaged either in transit or by misuse, accident or negligence. No warranty or representation by anyone other than this Company shall be binding on us. To return a unit send only to the following address: SEC America, LLC 81 Ethan Allen Drive S. Burlington, VT 05403 PLEASE RETAIN YOUR ORIGINAL BILL OF SALE. IT MUST BE SUBMITTED WHEN MAKING ANY WARRANTY CLAIM Page 5

V Base Plate Mechanical Drawing 6.430 3.930 1.250 0.400 45 deg. @ 0.400 from edges (4 places) 0.468 1.650 0.080 0.625 0.869 0.125 0.580 0.215 dia. 4 places 0.250 5.430 C L 13.800 10.500 side view is symetric about the center line 0.200 dia. 4 places 0.562 0.625 4 places 0.125 radius 0.375 0.250 0.250 SEC America, LLC S. Burlington, VT 05407 DWG. NO. 63-1448 C REV Page 6

VI Electrical Specifications: Output Voltage: Output Voltage Adjust Range Continuous Max Load Amps: Maximum Power Dissipation: Maximum Input Current: Overload Protection: Cooling: 26.4 Nominal (Internally adjustable +,- 0.5V) 24.5 VDC to 28.0 VDC (internally adjustable) 40 ADC @ 40C ambient (Input 12.5 Vdc) 40 ADC @ 60C ambient 60 Watts @ Full Load (40A, 26.4 VDC out) 90 A (12 VDC in) Electronically current limited (primary protection) Circuit Breakers at the Input (secondary protection) Convection or Forced Air Thermostat Controlled Fan Output Ripple Voltage: 10 mv RMS (20C to 75C) 50 mv RMS (-30C) Input Voltage Range: 11 VDC to 15 VDC Input Output Isolation: Input and Output returns (Ground) are Common Low Voltage Cutout Circuit: Low Voltage cutout point: Low Voltage cutout Hysteresis: Adjustable from 10.5 VDC to 13 VDC (internally adjustable) 1.2 VDC @ 13.0 V/ 0.9 VDC @ 10.5 VDC Activation Circuits: 1) The unit may be activated through the command terminal #1 of terminal block TBA which when connected to +12 VDC of the vehicle will turn on the converter. 2) The converter may be turned on in sections by using the circuit breakers on the front panel. e.g. if only a 20 Amp load is required, section one only may be selected. Ambient Operating Temperature: Maximum Humidity: Maximum Elevation: Mechanical Specifications: Dimensions: Shipping Weight: Construction: Mounting Method: Mounting Centers: Hook Up: -30C to + 60C 100% non condensing 15000 ft. above sea level 13.7 L x 7.0W x 3.5 H (inches overall maximum) 10 lb. Steel base with Aluminum wrap around (painted) #12 Hardware via front and rear mounting flanges 13.3 x 3.87 (inches) 3 Position Splicer Terminal Blocks Page 7