P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

Similar documents
P5510. Users Manual. Pneumatic Comparison Test Pump

P5515, P5515-V, & P5515-EP Hydraulic Comparison Test Pump

P5510. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Tachometer. English. Users Manual

i400s Calibration Information Introduction

Calibration Manual. Detachable Jaw True-rms Clamp Meter

80PK-2A Type K Immersion Probe

Infrared Thermocouple Probe

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

PK-8270-X/PK-8370-X. Lines and Fittings Kit. Instructions. Introduction. How to Contact Fluke Calibration

P3000 Series. Users Manual. Pneumatic Deadweight Tester

Temperature Calibrator

302+/303 Clamp Meter. Users Manual

Users Manual. Phase Rotation Indicator

365 Detachable Jaw True-rms Clamp Meter

373 Clamp Meter. Users Manual

323/324/325 Clamp Meter

PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M

362 Clamp Meter. Users Manual

Users Manual. MegOhmMeter

362 Clamp Meter. Users Manual

233 True-rms Remote Display Digital Multimeter Safety Information

80PK-8 Type K Thermocouple Pipe Clamp Temperature Probe

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

716 Pressure Calibrator

Visit us at

1551A Ex/1552A Ex. Calibration Manual. Stik Thermometer


1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Go to to register your product and find more information.

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

MegOhmMeter. Users Manual

i3000s/i2000 Flex AC Current Probe

Users Manual. Airflow Meter

712 RTD Calibrator. Instruction Sheet. Introduction

5618B Platinum Resistance Thermometer User s Guide

HR-20P Pneumatically Controlled Pressure Regulator

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

1000FLT. Users Manual. Fluorescent Light Tester

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

11812 NE 116th Street TEL: Kirkland, WA USA FAX: INSTALLATION & SERVICE MANUAL AMFLOW PR7B Back Pressure Regulator

700G Series. Users Manual. Pressure Gauge

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

PY-11 Voltage & Continuity Tester

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

5616 Platinum Resistance Thermometer User s Guide

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

TIME-10 Process Control Stopwatch

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

MODEL G300 BRAKE BLEEDER

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Dual Flow Manifold Systems Instruction Manual

CRD610 Automatic Fitting Inserter

Old Proportioning Pumps

SOIL RESISTIVITY TESTER

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

718 30G/100G. Users Manual. Pressure Calibrator. 99 Washington Street Melrose, MA Phone Toll Free

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

CRD600 Automatic Fitting Inserter

Mini Jacks Instruction Manual

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

MODEL 7400 STRUT SPRING COMPRESSOR

AEROMOTIVE Part # L 4V Fuel Rails INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # /2 4.6L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

Hydraulic Bead Breaker Kit

Spray Nozzle Adapters

TACH-10 Contact / Non-Contact Tachometer

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications

ANALOG INSULATION RESISTANCE TESTER

2 Speed Hydraulic Hand Pump

ECONOMAIR SERIES CYLINDERS

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

MODEL 7600 STRUT SPRING COMPRESSOR

4-20mA DC PROCESS CLAMP METER

COMPRESSED AIR LOADER MODEL: AL-1

MEX (55) QRO (442) Web Controls

718 Series. Users Manual. Pressure Calibrator

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

Pressure Washer Hose Reel

AEROMOTIVE Part # / L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

Techcon Systems TS5620 Series Diaphragm Valve. User Guide

Pressurized oil drain for collection of used lubricants and anti-freeze.

25 GALLON PORTABLE OIL LIFT

MODEL G300 Brake Bleeder

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Color Change Valve. Instructions Parts List K

Operating and Installation Instructions

Installation, Operation and Maintenance of Airflex Quick Release Valve

Large Hydraulic Bead Breaker

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Transcription:

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump Users Manual PN 3952337 November 2010 2010 Fluke Corporation. All rights reserved. Printed in USA. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 11/99 To register your product online, visit register.fluke.com

Table of Contents Title Page Preparation... 1 How to Contact Fluke... 1 Operating Fluid Compatibility... 2 Safety Information... 2 Compressed Liquid... 2 Personal Protective Equipment... 2 Symbols Used in this Manual... 2 Connections... 3 Connect the Gauge... 4 Connect the Test Port Insert... 4 Operation... 5 Priming... 5 Operation... 6 Maintenance and Servicing... 6 Screw Press Seals... 6 Complete Disassembly... 7 Ancillary Equipment... 11 Angle Adapter, P5543... 11 Pointer Remover/Punch, P5551... 11 i

P5514, P5514-V & P5514-EP Users Manual ii

List of Tables Table Title Page 1. Operating Fluid Compatibility... 2 2. Symbols... 3 3. Test Port Insert - Parts List... 5 4. Seal Kit - Part Numbers... 6 5. Screw Press Assembly - Parts List... 10 iii

P5514, P5514-V & P5514-EP Users Manual iv

List of Figures Figure Title Page 1. Connecting the Gauge... 4 2. Test Port Insert... 5 3. Reservoir and Test Port Assemblies... 9 4. Screw Press Assembly... 9 5. Angle Adapter... 11 6. Pointer Remover/Punch... 11 v

P5514, P5514-V & P5514-EP Users Manual vi

Preparation The Hydraulic Comparison Test Pump User s Manual covers the following instruments: the P5514, P5514-V, and the P5514-EP. The Comparison Test Pump is used for checking pressure-measuring instruments against Master Test Gauges. Note The terms Master Test Gauge and Gauge in this document refer to any pressure-measuring instrument such as Transfer Standards, Digital Calibrators, and Transducers. This system is only as accurate as the Master Test Gauge used. The Master Test Gauge must be regularly calibrated on a Primary Reference Standard (such as a Deadweight Tester) to ensure accuracy is maintained. The comparison test pump should be mounted securely to a stable workbench or similar surface. Four mounting holes are provided in the pump stand for this purpose. How to Contact Fluke To order accessories, receive operating assistance, or get the location of the nearest Fluke distributor or Service Center, call: Technical Support USA: 1-800-99-FLUKE (1-800-993-5853) Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31-402-675-200 China: +86-400-810-3435 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 1

P5514, P5514-V & P5514-EP Users Manual Operating Fluid Compatibility The standard system is designed for use with a wide range of fluids; however, the O-ring seals are Nitrile; use of solvents, fuel oils, brake fluids or other, similar aggressive fluids can damage the seals. The table below details the two alternative versions of this instrument, which offer increased compatibility with other fluids. Table 1. Operating Fluid Compatibility Model P5514 P5514-V P5514-EP O Rings Nitrile Viton Ethylene Propylene Rotate reservoir dust cover through ½ turn and fill reservoir approximately 3/4 full with the appropriate fluid. Rotate dust cover back to cover reservoir. W Caution To avoid damage to the instrument, the operator should check the quality of the operating fluid during use. If the fluid becomes discolored, cloudy or particles appear in the reservoir, the system should be drained and flushed with clean fluid. Safety Information The following are general safety precautions that are not related to any specific procedures and do not appear elsewhere in this publication. These are recommended precautions that personnel must understand and apply during equipment operation and maintenance to ensure safety and health and protection of property. Compressed Liquid Use of compressed liquids can create an environment of propelled foreign matter. Pressure system safety precautions apply to all ranges of pressure. Care must be taken during testing to ensure that all hydraulic connections are properly and tightly made prior to applying pressure. Personnel must wear eye protection to prevent injury. W Warning If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Personal Protective Equipment Wear eye protection approved for the materials and tools being used. Symbols Used in this Manual In this manual, a Warning identifies conditions and actions that pose a hazard to the user. A Caution identifies conditions and actions that may damage the Hydraulic Comparison Test Pump. Symbols used on the Hydraulic Comparison Test Pump and in this manual are explained in Table 2. 2

Hydraulic Comparison Test Pump Connections Table 2. Symbols Symbol B J W ~ Description AC (Alternating Current) Earth Ground Important Information: refer to manual Do not dispose of this product as unsorted municipal waste. Go to Fluke s website for recycling information. Connections Fit the device under test (DUT) to the test port using the method described below: W Caution Ensure that all devices are internally clean and free from contamination before connecting to the tester. Particle contamination can damage the sensitive piston assemblies, valve seats, and screw pump. To avoid cross-contamination from other fluids and protect the system from particulates, we recommend the use of a Liquid-to-Liquid Separator (see Section 5, Ancillary Equipment). W Warning DO NOT use Teflon/PTFE tape on these connections as this will prevent correct sealing. The Gauge Adapter sealing system is designed for hand-tight sealing up to 20,000 psi / 1,400 bar-wrenches or similar tools are not required over tightening can cause damage to threads or sealing faces. Before connection, ensure that there is an O-ring fitted to the test port. Check that the sealing face of the device to be fitted is clean and undamaged, as scratches or dents can form leak-paths. Note The thread on the test port, and the lower part of the gauge adapters is LEFT-HANDED. The following procedure details the correct method for mounting devices using these adapters. 3

P5514, P5514-V & P5514-EP Users Manual 1 2 3 4 Figure 1. Connecting the Gauge gjq001.eps Connect the Gauge Refer to Figure 1 for steps 1 to 4. 1. Screw the appropriate gauge adapter fully on to the instrument to be tested. 2. Screw assembly down COUNTER-CLOCKWISE on to test port. Note Hand-tight is sufficient; ensure that the bottom face contacts the O-ring on the test port. 3. To adjust the position to face forward, hold the gauge adapter and turn the instrument COUNTER-CLOCKWISE, so that it faces forward. 4. Hold the instrument steady, while turning the gauge adapter COUNTER-CLOCKWISE until it pulls down onto the O-ring. Connect the Test Port Insert For devices with 1/8 BSP or NPT mounting threads, the diameter of the thread is very close to the effective sealing diameter of the O-ring fitted to the test port. This can make it difficult to achieve a good seal. When mounting these devices, use the test port insert (stored in the spare seals container) as shown Figure 2. 4

Hydraulic Comparison Test Pump Operation 2 1 3 4 Figure 2. Test Port Insert gjq002.eps Table 3. Test Port Insert - Parts List Item Description P5515 P5515-V P5515-EP 1 O Ring 3865142 3865163 3867888 2 Test Port Insert 3919892 3 O Ring 3883397 3883521 3867895 4 Test Port 3918298 To calibrate panel-mounted gauges with pressure connections in the rear, use an Angle Adapter (see Ancillary Equipment section). Operation Priming 1. Open reservoir valve (13) one turn counter-clockwise and turn screw press fully in. 2. Close valve (13) and turn screw press fully out. 3. Open valve and turn screw press fully in. Note During this operation, bubbles may appear in the reservoir, as trapped air is expelled. For large volumes, repeat steps 2 and 3 until no further bubbles appear. 4. With valve open, turn screw press fully out and close valve. The test pump is now ready for use. W Warning Turning the capstan out with the reservoir valve closed will generate approximately 15 inhg / 0.5 bar vacuum. If the DUT is vacuum sensitive, leave valve (13) open during priming operation. 5

P5514, P5514-V & P5514-EP Users Manual Operation W Warning Do not exceed the maximum working pressure of the instrument (stated on the instrument label). 1. Turn the screw press in to generate pressure. 2. Allow a few moments for the system to stabilize before taking any readings, especially after large changes in system pressure. Note Large, sudden changes in pressure will cause the system temperature to rise or fall, which can cause instrument readings to change as the fluid in the system expands or contracts, thus increasing or decreasing the pressure. 3. Compare the reading of the gauge under test with that of the master gauge. 4. For the next higher calibration point, repeat from Priming, Step 1. 5. To measure reducing pressures, turn the screw press out (counter-clockwise). 6. Depressurize the system by turning the screw press FULLY OUT, then open the reservoir valve W Caution Never release the system pressure by using the reservoir valve alone, as sudden depressurization will shock the system, which may cause damage to sensitive instruments attached to it. Maintenance and Servicing The Figures on the following pages detail the components of each assembly, together with the relevant part numbers. Where ASSY appears as a part number, this indicates that this particular component is associated with other components in an assembly for replacement purposes. Before beginning any maintenance, remove any instruments that may be mounted to the test pump, and drain the fluid from the system. Table 4. Seal Kit - Part Numbers Model Seal Kit P/N P5514 3891113 P5514-V 3891124 P5514-EP 3891136 Screw Press Seals 1. Turn the screw press out so that there is a distance of at least 1 / 2.5cm between the large union nut at the end of the barrel and the capstan hub. 2. Unscrew the union nut and withdraw the lead screw assembly (24) from the barrel, taking care not to drop the rambler (22). 3. Inspect the seals for signs of wear or damage, replace as necessary. 6

Hydraulic Comparison Test Pump Maintenance and Servicing 4. The white, anti-extrusion ring (21) is a PTFE spiral, and can be removed by unwinding it from the rambler. 5. When removing the rambler seal (20), take care not to use any tool that may have a sharp edge that will scratch the surfaces of the rambler, otherwise it may leak when reassembled. 6. The replacement rambler seal can be eased over the front of the rambler, and into the groove. 7. Similarly, the new anti-extrusion ring can be wound into the groove in the rambler, behind the rambler seal. 8. If the rambler has been separated from the lead screw, ensure that the ball (23) is correctly fitted before reassembly. 9. Ensure that the rambler assembly is correctly located on the end of the lead screw assembly. Carefully introduce the rambler into the open end of the barrel; making sure that it does not tilt when entering the barrel. 10. Push the lead screw assembly fully in to the barrel, ensuring that the key in the nut locates correctly in the slot in the barrel. 11. Re-tighten the barrel union nut. W Caution If the lead screw assembly (24) shows signs of excessive wear, then it is very likely that the associated components have worn also; therefore, the screw press assembly is available as a spare part. Complete Disassembly 1. Remove the screw press assembly as described above. 2. Unscrew and remove valve stem (13), taking care not to lose spring (12) and nylon washer (11). 3. Remove reservoir cover (10). 4. Unscrew locknut (9), and remove reservoir (8). 5. Unscrew valve body (6), taking care not to lose bonded seal (7) or O-ring (5). 6. Remove banjo bolts (1), together with banjo test ports (3), taking care not to lose O-rings (2). 7. Disconnect the stand (15) from the bench. Remove screws (14), and tilt manifold/barrel assembly downward and pass it out of the bottom of the stand. 8. To remove the barrel (19), the locknut (18) must be loosened approximately 1/2 turn. The barrel can then be unscrewed from the manifold (16). 9. Before re-fitting the barrel, ensure that the barrel seal (17) is correctly located in the counter-bore in the front of the barrel. Screw the barrel fully in to the test station, and secure with the locknut. 10. Inspect all seals for wear or damage replace as necessary. 7

P5514, P5514-V & P5514-EP Users Manual W Caution If the rambler shows signs of wear, then it is very likely that the main bore in the barrel is worn also. If the bore is worn or scratched, it will not seal correctly, and may leak under pressure. 11. Re-assembly is the reverse of the above. Ensure that all seals and sealing surfaces are clean and undamaged. 13 12 11 10 8 9 7 14 6 14 4 4 5 3 3 1 1 2 2 15 Figure 3. Reservoir and Test Port Assemblies gjq003.eps 8

Hydraulic Comparison Test Pump Maintenance and Servicing 17 18 19 26 16 25 21 20 22 23 24 25 26 Figure 4. Screw Press Assembly gjq004.eps 9

P5514, P5514-V & P5514-EP Users Manual Table 5. Screw Press Assembly - Parts List Item Description Part P5514 P5514-V P5514-EP 1 Banjo Bolt 3918323 2 O Ring 3905652 3919393 3926936 3 Banjo Test Port 3918298 4 O Ring 3883397 3883521 3867895 5 O Ring 3864857 3865277 3921986 6 Valve Body 3923785 7 Bonded Seal 3862349 3922096 3922043 8 Reservoir 3919463 9 Locknut 3918244 10 Reservoir Cover 3918350 11 Washer 3916458 12 Spring 3922786 13 Valve Stem Assembly 3885982 14 Screw 3909422 15 Pump Stand 3918271 16 Manifold 3918280 17 O Ring 3864711 3865359 3865576 18 Locknut 3917862 19 Barrel 3919630 20 O Ring 3864782 3865214 3865541 21 Back-Up Ring 3920516 22 Rambler 3919611 23 Ball 3917855 24 Lead Screw Assembly 3885982 25 Spoke 3921672 26 Knob 3917843 10

Hydraulic Comparison Test Pump Ancillary Equipment Ancillary Equipment Angle Adapter, P5543 To calibrate gauges with the pressure connection on the rear (e.g. panel-mount gauges) in their correct position, an angle adapter should be used. The angle adapter fits directly onto the test station, converting it through 90 degrees, allowing the standard adapters to be used. Figure 5. Angle Adapter gjn022.bmp Pointer Remover/Punch, P5551 To remove and refit the pointer of a pressure gauge, use the pointer remover/punch instrument. This tool has a spring-loaded plunger to quickly and consistently refit the pointer. Figure 6. Pointer Remover/Punch gjn023.bmp 11

P5514, P5514-V & P5514-EP Users Manual 12